Directorate of Municipal Administration
SHIVAKUMAR
Repair of 360 H.P. Deepwell turbine pump & Vacuum contactor at Jackwell Pumphouse Near K.R.Nagara. AND Repair of 120 H.P. Soft starter Panel of Non Clog Sewage Pumpset at Wetwell near Kalkunike Circle, CMC, Hunsur
DMA/2025-26/WS/WORK_INDENT56410
DMA/2025-26/WS/WORK_INDENT56410
Open
Water supply/sewage lines
Electronic Documents, First(One Cover)
DMA City Municipal Council Hunasuru
7 documents required · 7 mandatory
₹500
₹37,000
30 Mar 2026
13 Mar 2026
30 Mar 2026
Repair of 360 H.P. Deepwell turbine pump & Vacuum contactor at Jackwell Pumphouse Near K.R.Nagara. AND Repair of 120 H.P. Soft starter Panel of Non Clog Sewage Pumpset at Wetwell near Kalkunike Circle, CMC, Hunsur
Removing & refixing the pump after repairing of existing horizontal mounting/ monoblock pump with following spares, etc. including aligning of pump with reference to motor & running the pump on load. ...
Supply & fixing of Bolt,Nuts for Column pipe Flange. (Data rate approved by S.E. MCC)
Providing and fixing of Leather packing sheet for column pipe Flange. (data rate approved by S.E. MCC)
Providing Ball bearing as per ISI specifiction with guarantee period of not less than 12 months- (for Pump top-phosphorus Bronz Bearing) Bearing cost for 360 HP. (P-159, It-13.50,15 of Vol-5)
Providing thrust bearing as per ISI specifiction with guarantee period of not less than 12 Months- (phosphorus Bronz) Bearing cost for 360 HP. (P-159, It-13.51.10 of Vol-5)
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump. Phosphorous bronze bearing bush for 360 HP VT Pump. (P-159, It-13.53.5 of V...
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump. Phosphorous bronze Stage bush for 360 HP VT Pump. (P-159, It-13.54.5 of Vo...
Repairs to Vertical turbine pumps as per ISI specifiction with guarantee period of not less than 12 months V- T Pump. IMPELLER AND NECK RING for 360 HP VT Pump. (P-159, It-13.55.5 of Vol-5)
ALL TYPES OF JACK WELL V-T PUMP DETAILS as per ISI specifiction with guarantee period of not less than 12 months -For Pump dismentaling and refitting after attending repairs. For Pump gear box body ...
ALL TYPES OF JACK WELL V-T PUMP DETAILS as per ISI specifiction with guarantee period of not less than 12 months -For Pump dismentaling and refitting after attending repairs. For Impeller breezing ma...
ALL TYPES OF JACK WELL V-T PUMP DETAILS as per ISI specifiction with guarantee period of not less than 12 months -For Pump dismentaling and refitting after attending repairs. For For Pump open & fit...
Re-Errection of 370 HP DWT pump set using chain pully, Stage by stage lowering the stainer, bowl assembly, Column assembly, fixing discharge head assembly, by using grees oil etc,. Complete for coupli...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, dicatorON/OFF, energycross-3 withShort circuitbreaking capacityof...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, dicatorON/OFF, energycross-3 withShort circuitbreaking capacityof...
Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessarybolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 200 A...
Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessarybolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 250 A...
Work of repair and rewinding of reactor provided to isolator of motor as specified below: A) Drain out the contaminated transit oil completely form the reactor; flush the windings of the reactor wit...
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (Page 19, Item No. 5.38 of PWD Ele SR Vol-VI)
Supply and fixing of Multifunctional three phase monitoring relays suitable to monitor three phase mains. It monitors all phase parameters such as over/undervoltage, phase unbalance, phase failure...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
kw-1 Jackwel Pump Repair.doc
Tender Document • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .