Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC VILLAGE BADITTER P O JOURE AMB TEHSIL BADSAR DISTT HAMIRPUR H P | HAMIRPUR | HIMACHAL PRADESH | 174304 | L1 | Accepted-AOC Accpeted as per rank and found L1 and work awarded | |
| 2 | L2₹33.6 L+₹2.1 L (6.76%)Accepted-AOC | L2 | Accepted-AOC Accpeted as per rank partciapted in the tender | |
| 3 | L3₹34.0 L+₹2.5 L (7.91%)Accepted-AOC | L3 | Accepted-AOC Accpeted as per rank partciapted in the tender | |
| 4 | L4₹34.8 L+₹3.4 L (10.7%)Accepted-AOC | L4 | Accepted-AOC Accpeted as per rank partciapted in the tender | |
| 5 | L5₹35.9 L+₹4.4 L (14.1%)Accepted-AOC HPSEBL THALOUT | L5 | Accepted-AOC Accpeted as per rank partciapted in the tender |
Tender Value
Refer Docs
EMD Value
₹74,945
Closing Date
15 Dec 2020, 11:00 amClosed
EE JSV Division Barsar
EE JSV Division Barsar
SH C-O Infiltration gallery 15 meters long Pump house raw water tank 70000 liters capacity Sedimentation tank 20000 liters filter beds 2 units clear water tank sump well 70000 liters
2020_HPIPH_42852_1
. EE-JSV-BSR-TA 20-21- 14648-748
Open Tender
Civil Works
Item Rate
90 days
JSV Sub Division Barsar
Please refer Tender documents.
7 documents required · 7 mandatory
₹800
Yes
EE JSV Division Barsar
₹74,945
Yes
9 Jun 2021
2 Dec 2020
15 Dec 2020
2 Dec 2020
15 Dec 2020
2 Dec 2020
2 Dec 2020 - 15 Dec 2020
Amount
Excavation in foundation , trenches etc., in all kinds of soil such as pickwork, jumper work blasting work, in soft / hard rock, including chiseling wedging out of rocks clearance of bushes etc.including shoring, dewatering etc. in all leads and lifts stacking the excavated soil upto any lead and lift clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth , sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus earth within all leads and lifts complete to the entire satisfaction as directed by the Engineer-in-charge of the site of work.
Eearth work without dewatering
Eearth work without dewatering
Providing and Laying cement concrete1:6:12 (1Cement :6Sand:12 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Squared rubble stone masonry coursed with hard stone of approved quality in foundation & plinth including racking out of joints in cement mortar 1:6 ( 1 cement :6 sand ) in all leads & lifts
Brick work using common burnt clay building bricks (IInd class) in in super structure above plinth level upto floor two level in cement mortar 1:6 (1cement:6 sand) in all leads and lifts..
Half brick masonery in common burnt clay building bricks in cement mortar 1:4( 1cement :4sand) 2nd class birck complete in all leads and lifts.
Providing wood work in frames of doors, windows and other frames wrought framed and fixed in position with second class deodar wood in all leads and lifts.
Providing and fixing wood paneled glazed or paneled and glazed shutters for doors, windows and clear story 40mm thick windows including bright finished black enameled iron with necessary screws with second class deodar wood 40mm thick in all leads and lifts.
Providng and fixing wire gauge shutters using GMS wire guage of IS gauge designation 85 G with wire of dia 0.56 mm for doors, windows & clerestory windows including bright finished black enamelled iron hinges with necessary screws.2nd class deodar wood.40mm thick including 6 mm thick PVC solid sheet with required adhesive in all leads and lifts.
Providing and Laying cement concrete1:3:6 (1Cement :3Sand:6 graded stone aggregate 40 mm nominal size) including curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing and Laying cement concrete M25 ( Design Mix) not leaner than ) 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
Foundations,footings bases of columns and the like and mass concrete in all leads and lifts. in all leads and lifts.
Walls (any thickness but not less than 0.10 metre thickness) including attached pilasters buttersses ,plinth and string courses etc. from top of foundation upto floor two level in all leads and lifts.
Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts.
Arches beyond 6 metres span.
Providing and Laying cement concrete 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
Foundations,footings bases of columns and the like and mass concrete in all leads and lifts. in all leads and lifts.
Suspended floors,roofs,landing shelves and their supports balconies beams,girders bressumers and cantilever upto floor two level including carriage of material in all leads & lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4meters and removal of the same for insitu reinforced concrete and plain.
Foundations,footings bases of columns and the like and mass concrete complete in all respects in all leads and lifts.
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Flat surfaces such as soffits of suspended floors, roofs, landings and the like floors etc. above 200mm. In thickness with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge
Sides and soffits of beams, beams hunching, cantilevers, bressumers and lintles not exceeding 1 meter in depth in all heights from floor complete in all respects in all leads and lifts
Providing and Laying cement concrete M30 ( Design Mix) not leaner than ) 1:1.5:3 nominal size (1Cement :1.5 Sand:3graded stone aggregate 20 mm nominal size) & curing complete excluding the cost of form work and reinforcement for reinforced concrete work in :-
Foundations,footings bases of columns and the like and mass concrete complete in all respects in all leads and lifts.
Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level including carriage of material in all leads & lifts.
6 mm cement plaster to ceiling in cement mortar 1:3 (1Cement :3 Sand) in all leads and lifts.
15 mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) in all leads and lifts.
20 mm cement plaster in single coat of rough sides of bricks/concrete stone walls for interior plastering upto floor two level including arrises internal rounded angles chamber and rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortar 1:6(1cement:6sand) in all leads and lifts.
Providing from work of ordinary timber plankings so as to give a rough finish including centring,shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceililng not exceeding 4 metres and removal of the same for insitu reinforced concrete.
Arches beyond 6 metres span.
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) with in all leads and lifts & to the entire satisfaction of the Engineer-in-charge.
Steel work welded in built up sections,trusses & framed work, including cutting ,hoisting & fixing in position & applying a priming coat of red lead paint :- In grating, framed ,guards,bars, ladders, railing, brackets & similar works in all leads and lifts..
Laying jointing and testting of GMS pipe following dia (medium/ light class) for scour pipe, inlet pipe , over flow pipe & distribution system including carriage of material in all leads & lifts.( Labour rates.)
100 mm dia .
80 mm dia .
Providing and fixing double flanged C.I sluice valve of following dia (with hand wheel) as per IS: 780 (including brass spindleand as per IS: 2906 Class-II complete with bolts., nuts, rubber insertion etc. ( along with tail pieces if required) following dia including all leads and lifts complete. ( Bir make) with M.S. flanges of table 5.
100 mm dia .
80 mm dia .
Constructing chamber for sluice valves with C.I surface box 100mm top diameter, 160mmbottom diameter and 180mm deep (inside with chained lid and RCC top slab1:2:4(1cement:2sand: 4 graded stone aggregate 20mm nominal size ) 100mm thick foundation concrete 1:5:10 (1cement :5sand:10 graded stone aggregate 40mm nominal size ) and insideplastering with cement mortar 1:3(1cement:3sand) finished with a floating coat of neat cementincluding curing complete with 600x600x750mm inside size with 150mm thick wall of RCC 1:2:4 ( 1cement :2sand :4 graded stone aggregate 20mm nominal size ) complete with formand reinforcment with 6mm bars at not exceeding 150mm centres both ways in all leads andlifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and fixing SFRC Man hole cover with frame having frame size of 560mm internal dia (Medium duty) The Weight of cover & frame should not less than 100kg including carriage ofmaterial in all leads & lifts.
Providing and fixing CI Man hole cover with frame having frame size of 500mm internal dia (Medium duty) The Weight of cover & frame should not less than 116kg including carriage ofmaterial in all leads & lifts.
Boulder filling behind the long wall facing toward upstream side of infilteration gallery complete in all leads and lifts
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts.
Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dial meters bolts and nuts and wooden plug and embeding in cement mortar block 30x10x15cm 1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size in all leads and lifts..
Providing and fixing M.S.fan clamp(Type-I of 16mm dial M.S. Bar bent to shape with hooked ends in RCC. Slab during laying including painting the exposed portion of loop all as per standard design complete in all leads and lifts.
White washing with lime on undecorated walls surface (two coats) to give an even shade including thoroughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts.
Distempering(two coat) with oil bound washable distemper of approved brand and manufature and of required shade,on decorated wall surfaces to give an even shade,after thoroughly brushing the surface clean of all grease,dirt,loose pieces of scales and also including preparing the surface even and sand papered smooth. in all leads and lifts.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces(twocoats)to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered material complete in all leads and lifts.
Painting two coat (excluding priming coat) on new steel and other metal surfaces with enamel paint brushing to give an even shade including cleaning the surface of all dirt,dust and other foreign matter with Enamel paint other than white in all leads and lifts.
Precast terrazzo tiles hydraulic compressed 20 mm thick with marble chips of specified sizes laid in floors, treads of steps and landings on a bed of 25 mm average thickness of cement mortar 1:6 (1 cement :6 sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles (wherever required) incliding rubbing and polishing complete with tiles of following shades:- complete in all leads and lifts.
Providing and fixing M.S. grill of required pattern in wooden frames of windows etc. with M.S. flat square or rounded with round head nuts and bolts or by screwed complete in all leads and lifts.
Providing and fixing following anodized aluminium fittings of anodized transparent and shade with necessary screw etc.complete
(a) Sliding door bolts 250x16mm.
(b-i) M.S. tower bolts (Barrel type) leads and lifts. 200x10mm.
(c-ii) M.S. handles 100mm dia
Precast concrete block masonry in partition walls 10 cm. thick with solid block of approved size including quion blocks, jamb blocks, closer etc. made of cement concrete 1:3:6 (1 cement:3 sand:6 graded stone aggregate 40mm and down gauge I cement mortar 1:3( 1cement:3sand ) in all leads and lifts.
Providing and placing the filter media in horisontal layer duly graded, screended and cleaned as per specification complete in all respecrts and in all leads and lifts and to the entire satisfaction of the Engineer-in-Charge.
Top layer :- Fine sand effective size : 0.20 to 0.40 mm and uniformity co-efficient (2-3) .
2nd layer:- Coursed sand 3 mm to 6mm .
3rd Layer :- 6 mm to 20mm
4th Layer Bajri :- 20mm to 25mm
Bottom Layer :- Broken stone 50mm to 75mm
Rama Shankaer
VINAY KUMAR SHARDA
RANDEEP SINGH GOVT CONT
Naresh Kumar
M/s.Pawan Kumar Sharma
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .