| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC LINE PAR NAI BASTI OSARH ROAD FARIDPUR DISTT BAREILLY PIN 243503 | FARIDPUR | BAREILLY | BAREILLY | 243503 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.1 L+₹1.1 L (3.13%)Rejected-Finance MALANCHA ROAD KHARAGPUR 721304 DIST WEST MIDNAPORE WEST BENGAL | KHARAGPUR | WEST MIDNAPORE | WEST BENGAL | 721304 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹38.9 L+₹3.9 L (11.2%)Rejected-Finance JAIN BUILDING KHARIDA MAIN ROAD KHARAGPUR 721301 WB | MEDINIPUR WEST | WEST BENGAL | 721301 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹40.7 L+₹5.7 L (16.2%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹42.0 L+₹7.0 L (20.0%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | Guru Charan Mahata L4 | T K Construction L2 | M/S OM BUILDERS L1 | Palak Infracon L3 | SUMAN CONSTRUCTION L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings.Complate all as specified and as directed. | 200 | Sqm | 15 ₹3,000 Lowest | 35 ₹7,000 | 22 ₹4,400 | 60 ₹12,000 | 33 ₹6,600 |
| 2.00 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings of any size and any description , at height upto 18m with all scaffolding and all necessary safety measures.Complate all as specified and as directed. | 418 | Sqm | 12 ₹5,016 Lowest | 30 ₹12,540 | 22 ₹9,196 | 45 ₹18,810 | 100 ₹41,800 |
| 3.00 | Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge | 2 | Qtl | 200 ₹400 | 150 ₹300 | 45 ₹90 Lowest | 750 ₹1,500 | 900 ₹1,800 |
| 4.00 | S&F Pre-painted galvalume aluminum zinc coating GI based Corrugated steel sheet 0.50mm thick AZ150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws.Complate all as specified and as directed. | 600 | Sqm | 1,125 ₹6,75,000 | 1,145 ₹6,87,000 | 830 ₹4,98,000 Lowest | 1,050 ₹6,30,000 | 1,200 ₹7,20,000 |
| 5.00 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick AZ150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws.Complate all as specified and as directed. | 18 | Sqm | 1,125 ₹20,250 | 1,045 ₹18,810 | 830 ₹14,940 Lowest | 1,000 ₹18,000 | 1,200 ₹21,600 |
| 6.00 | S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde E-250 Quality A).Complate all as specified and as directed. | 200 | Kg | 165 ₹33,000 | 140 ₹28,000 Lowest | 160 ₹32,000 | 145 ₹29,000 | 178 ₹35,600 |
| 7.00 | M&L for preparation of new or previously untreated steel or iron surfaces of any description over 10cm in girth or width not otherwise described and applying one coat of red oxide , zinc chrome primer and two coats of synthetic enamel paint.Complate all as specified and as directed. | 55 | Sqm | 95 ₹5,225 | 95 ₹5,225 | 63 ₹3,465 Lowest | 130 ₹7,150 | 99 ₹5,445 |
| 8.00 | M&L for preparation of old surfaces including complete removal of existing treatment on steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed | 110 | Sqm | 95 ₹10,450 | 90 ₹9,900 | 58 ₹6,380 Lowest | 130 ₹14,300 | 99 ₹10,890 |
| 9.00 | Taking down eaves, gutter and rain water pipe any size or pattern including all fittings complete all as specified and as directed. | 50 | Rm | 5 ₹250 Lowest | 45 ₹2,250 | 25 ₹1,250 | 60 ₹3,000 | 22 ₹1,100 |
| 10.00 | S&F PVC (SWR) pipes 150mm bore single socketed in any length with rubber ring joints fixed to walls.Complate all as specified and as directed. | 50 | Rm | 352 ₹17,600 | 190 ₹9,500 | 380 ₹19,000 | 55 ₹2,750 Lowest | 800 ₹40,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jul 2025, 6:00 pmClosed
Major MK Yadav, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
REPAIRS TO ROOF SHEETS AND ROOF TREATMENT TO VARIOUS BUILDINGS AT TECHNICAL AREA AT AF STATION KALAIKUNDA UNDER GE(AF) KALAIKUNDA
2025_MES_715037_1
C/8160/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN KALAIKUNDA
Class D Category a(i)
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹90,000
Yes
23 Aug 2025
17 Jun 2025
17 Jul 2025
17 Jun 2025
15 Jul 2025
2 Jul 2025
Amount
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings.Complate all as specified and as directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings of any size and any description , at height upto 18m with all scaffolding and all necessary safety measures.Complate all as specified and as directed.
Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge
S&F Pre-painted galvalume aluminum zinc coating GI based Corrugated steel sheet 0.50mm thick AZ150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws.Complate all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick AZ150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws.Complate all as specified and as directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde E-250 Quality A).Complate all as specified and as directed.
M&L for preparation of new or previously untreated steel or iron surfaces of any description over 10cm in girth or width not otherwise described and applying one coat of red oxide , zinc chrome primer and two coats of synthetic enamel paint.Complate all as specified and as directed.
M&L for preparation of old surfaces including complete removal of existing treatment on steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Taking down eaves, gutter and rain water pipe any size or pattern including all fittings complete all as specified and as directed.
S&F PVC (SWR) pipes 150mm bore single socketed in any length with rubber ring joints fixed to walls.Complate all as specified and as directed.
S&F PVC (SWR) bends any radius 150mm dia.Complate all as specified and as directed.
Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets.Complate all as specified and as directed.
S&F anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm, complete all as specifed and as directed. Fixed with 16 guage wire complete all as specified and as directed
S&F 4 mm thick non asbestos fibre cement building boards (designer type) fixed or laid/inserted to timber/GI/Aluminium frame work, complete all as specifed and as directed.
Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles.Complate all as specified and as directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6).Complate all as specified and as directed.
Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc.Complate all as specified and as directed.
M & L 10mm thick rendering in cement mortor 1:6 on fair faces of brick work and finishing surface even and smooth without using extra cement as specified.
M & L for rendering 5mm thick cement plaster in cm 1:3 on ceiling including finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of newly plastered wall surfaces and applying two coats of acrylic distemper 1st quality over a coat of wall care putty (1.5 mm thick) complete all as specified and as directed.
M & L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick or concrete surfaces with cement mortar 1:4 mixed with liquid water proofing compound @ 0.25% by weight of cement or as per manufacturer instruction and finishing the surface even & smooth without using extra cement complete all as specified and as directed. Note:- Liquid water proofing comound shall be measured & paid separately
Supply only Liquid Waterproofing Compound
Material and labour for applying two coat of 100% acrylic exterior emulsion paint in camouflage pattern (Three colour as approve by GE) over and including a coat of primer to new plastered of wall (including chajja, facia & ceiling surface) including preparation of surface of any height including all necessary scaffolding complete all as specified and as directed.
M&L for applying a coat of 1.5mm thick wall care putty(premium quality) over plastered surfaces of walls to prepare the surface even and smooth, at any height including all necessary scaffolding and safety measures complete all as specified and as directed.
Material and labour for complete removal of existing treatment and applying two coat of 100% acrylic exterior emulsion paint in camouflage pattern (Three colour as approve by GE) over and including a coat of primer to old plastered or unplastered sufaces of wall (including chajja, facia) including preparation of surface of any height including all necessary scaffolding complete all as specified and as directed.
Taking down existing roof felt including plaster of any description carefully from existing roof /parapet without disturbing wall surface and removing the same at a distance exc 1.5 Km complete all as specified and as directed.
Demolition of unrefinforced cement concrete as in Concrete of any description and in any position not otherwise specifically provided. complete all as specified and as directed.
Taking down and refixing the aluminium/copper earthing strips in same position with and including all new fittings and fixtures complete all as specified and as directed.
M&L for cutting chases,pinning in stone concrete block or slab wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings,steps,cills,sunshades,sheleves,lintels,etc and cutting chases for concealed water tubing or concealed conduct wiring,etc and making good,cutting n.exc 10cm girth, complete all as specified and as directed.
M&L for cutting chases,pinning in Brick wall making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings,steps,cills,sunshades,sheleves,lintels,etc and cutting chases for concealed water tubing or concealed conduct wiring,etc and making good,cutting exc 10cm but n.exc 20cm girth, complete all as specified and as directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in coping, benching at junction of roof and parapet wall finished fair and even complete all as specified and as directed.
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in padding concrete to maintain slope complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster in cement mortar 1:4 mixed with liquid water proofing compound as per manufacturer instruction complete all as specified and as directed. Note:- WPC shall be measured and paid separately under relevant item.complete all as specified and as directed.
M&L for cleaning of plastered roof surfaces and applying one coat of Cold Bituminous primer for use in waterproofing and damp-proofing treatments @ 0.25 Lit/Sqm confirming to IS:3384-1986.complete all as specified and as directed.
Providing and laying APP based polymeric membrane with mineral top finish weighing not less than 3.5 kg/sqm and minimum 3.0 mm thick reinforced with polyester non woven febric( weight not less than 160 gms/sqm) laid by torch application method over bituminous surface & overlap shall be minimum 75mm on longitudinal direction and 100mm on transverse direction.complete all as specified and as directed.
Taking Down the turbo ventilator of any description and any size or any pattern including cutting of roof sheet with and including all necessary fitting and fixtures, at any height including all necessary scaffolding and safety measures and as directed by Eng-in-Charge.
Supplying and Fixing the SS304 turbo ventilator of stainless steel with polycarbonated ventiloator base plate of existing profile,and having 0.3mm thick vanes of 38 nos, centre shaft- stainless steel, self lubricated bearing (02 nos), aluminium Pneumatic Rivets,1mm stainless steel turbine doom thickness,686 mm Turbine Outer Dia,380mm Turbine doom Dia,655mm Turbine rotar Dia,610mm Turbine Throat Dia, height of Turbine 360mm and weight of turbine 4.6 kg with and including all necessary fitting and fixtures, and upto 18m of height of including all necessary scaffolding and safety measures and as directed by Eng-in-charge.
S& F the bird proofing with mesh made of Anti-bird net UV black colour made of materials polyolefin all weather proof co-polymer of machine knotting using CNC machines with DSLS technology for antislip knotting heat setting shall be stearn set for greater dimensional stability and knot firmness and dia meter of mesh shall be 1 mm and size of the mesh 25 X 25 mm(+/-2mm) of square including 4mm dia GI wires@1000 mm across rafters/column or ther bracings and 10mm dia nylon ropes perpendicular to GI wires to create a support grid of 1m X1m including tuing of net to the purlins or other members using 10mm dia nylon ropes, and including taking down of existing bird net of any size descrioption and any size or pattern and upto 18m of height including all necessary scaffolding and safety measure and as directd by engineer-in-charge. . All arrangements for fixing and taking down of this bird net shall be from contractor side.
Spreading and levelling soft soil in layers of 15 cm thick each in existing traverse to a desired slope as directed by the engineer-in-charge. Measured and paid in per sqm per layer 15cm thick layers each and part thereoff in fractions to 15cm thickness. Note: Soil required shall be excavated from pits earmarked by the user unit and measured separately
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth to any lead and lift and deposited in layers as mentiones in Item above, as directed by Engineer-in charge
Cutting/chipping the spalling concrete surfaces of columns, beams, cantilever etc and trimming & cleaning the surface to receive guniting/plastering all as specified and directed from ground to 4th storeys including all necessary form work & scaffolding and safety measures and lowering down the demolished material for disposal and disposing the demolition material out of MD land.complete all as specified and as directed.
M&L for applying micro concrete Rendroc RG (S) or equivalent thickness n.exc 40 mm at mouth of rain water pipes,cracks in BP of any shape or size and any description, chajja etc and for structural members all as per manufacturers' instructions complete including Nitro Bond & leak proof form work coated with reabol mould release agent all as specified and directed including all necessary scaffolding.complete all as specified and as directed.
M&L for applying polymer modified mortar 15 mm thick with Nitobond AR or equivalent at the rate of 8 Ltrs per bag of PMM for restoring concrete cover to structural members complete all as specified and required including necessary scaffolding.complete all as specified and as directed.
Dismantling steel rolling shutters complete including shutter, ball bearing, canopy, side guides, locking arrangement etc, height shall be measured from the bottom of the lintel to the finished floor cill level, width shall be measured inclusive of width of the guide rails.complete all as specified and as directed.
S&F Steel rolling shutters 1.25mm thick , with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle and with all necessary fittings and fixtures, height shall be measured from the bottom of the lintel to the finished cill level and width shall be measured inclusive of width of the guide rails.complete all as specified and as directed.
T K Construction (BID ID -3348880)
Palak Infracon (BID ID -3358824)
Guru Charan Mahata (BID ID -3347473)
SUMAN CONSTRUCTION (BID ID -3358863)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .