Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.2 L+₹1.7 L (3.60%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹50.0 L+₹2.5 L (5.33%)Rejected-Finance NO 212 3RD CROSS KANAKADASA LAYOUT LINGARAJAPURAM BANGALORE 560 084 | BANGALORE | BANGALORE | KARNATAKA | 560084 | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹50.8 L+₹3.4 L (7.07%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹51.0 L+₹3.6 L (7.48%)Rejected-Finance | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
7 Sept 2021, 6:00 pmClosed
GE I R AND D East Bangalore
GE RD East Bangalore 93
REPAIRS REPLACEMENT OF FIRE ALARAM SYSTEMS PVC CABLE TRUNKING SYSTEM SUB MAIN WIRING EARTHING SYSTEMS REWINDING OF CEILING FANSEXHAUST FANS WALL MOUNTED FANS REPAIRS REPLACEMENT TO HIGH MAST LIGHTS SERVILLIANCE SECURITY LIGHT SYSTEMS FIRE SAFETY W
2021_MES_437031_1
8110
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D East Bangalore
D b (i)
9 documents required · 9 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹96,000
Yes
27 Oct 2021
19 Apr 2021
9 Sept 2021
19 Apr 2021
7 Sept 2021
24 May 2021
20 Apr 2021 - 30 Apr 2021
Amount
M & L for earthing complete with copper earth plate of size 600 x 600 x 3.15 mm buried directly and preferably vertically in ground with top edge not less than 1.25M below ground level connected with copper earth strip of 20 x 3 mm connected to the earthing test point all as specified and all as directed by Engineer incharge including testing and submission of test reports. Note : The rates quoted are inclusive of copper earth strip upto the standard length as specified in the SSR part -1. However additional length will be measured and paid seperately in respective item.
M & L for copper earth continuity main earthing Strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit of size 20 x 3 mm all as specified and directed.
Supply and fixing DLP U-PVC Cable trunking systems and acessories snap on trunking 80 x 50 mm supplied without cover, Legrand Cat no : 010412 80mmx50mm PVC Trunking
Supply and fixing of Flexible cover only, full cover size width 65 mm suitable for 80mmx50mm PVC Trunking Make : Legrand Cat no. : 010521
Supply & Fixing in repairs new generation Post top 40 watts 360 degree IP65 protection all prewired fixed on the existing GI Pipe inclduing testing complete all as specified and as directed. Make : CG, Model : MAPLE, Cat Part NO LPTO-40/CDL - M complete or equivalent of HAVELLS/WIPRO/BAJAJ
Supply & Fixing in repairs LED Step Light, 6 Watts, Make : CG, Model : BEACON, CAT REF : LSL-6-CDL
Supply & Fixing in repairs flood lighting LED 120 Watts, Pressure die cast with IP66 protection, SPD to be included Make : CG, Model : PLUTO NEO, CAT REF : LFL-120-CDL/60-M
Supply & Fixing in repairs flood lighting LED 80 Watts, Pressure die cast with IP66 protection, SPD to be included Make : CG, Model : PROFILE + NEO, CAT REF : LFL- 80 -CDL/60-M
Supply & Fixing in repairs LED Bollard light fitting, IP65, 10 Watts, Make : Crompton Greaves, Model : TWISTER, CAT REF. LBLTW- 10-WW
Supply & Fixing in repairs LED Bollard light fitting, IP65, 10 Watts, Make : Crompton Greaves, Model : LIARA, CAT REF. LBLSN- 10-CDL
Supply & Fixing in repairs Timelite Distribution Boards for controlling of timing of street lights, Timelite- 40 A 3 pole /230 volts Digital time switch , Make : INDO ASIAN, CAT REF : TL040DB0
Supply & Fixing in repairs street light Digital Time Switches type suitable for street light control. DIN Type Daily/ weekly with 1 CD programmable every 1 min, back of 6 years, 28 memory locations. Make : INDO ASIAN, CAT REF : TDA43110
M&L for painting of steel tubular 9 mtr long poles after preparing old paint surfaces with two coat of Aluminium paint and two coats of zebra marking with enamel paint from ground level & upto 1 mtr high including white washing the coping and cleaning the bushes surrounding the pole bottom upto 1 mtr width all as specified and as directed.
M&L for painting of RCC poles 5 / 6 mtr long with two coats of exterior emulsion paint including white washing the coping and painting the pole terminal box all as directed by Engr-In-Charge.
M & L for marking of pole nos on the MS /Concrete poles with wheather proof paint in serial wise complete all as directed
Removing the existing unserviceable PVC junction boxes supply and fix PVC enclosure (140 mm x 140mm x 95mm) weather, dust and, rain guarded, cable entry and exit arrangement of suitable size of housing of with 01 No MCB SP 10 Amps including nuts, bolts clamps for fixing to pole, including end termination of cables of size 25 / 35 sqmm 2 Nos in each box complete all as directed. Make : Sintex, model GSJB-1414
Removing the existing unserviceable PVC junction boxes supply and fix PVC enclosure (210 mm x 140mm x 95mm) weather, dust and, rain guarded, cable entry and exit arrangement of suitable size of housing of with 01 No MCB SP 10 Amps including nuts, bolts clamps for fixing to pole, including end termination of cables of size 25 / 35 sqmm 2 Nos in each box complete all as directed. Make : Sintex, model GSJB-2114
Dismantalling of existing RCC/steel pole by breaking/ removing, Supply and fixing of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers as specified type of 410 SP - 31 (9.00 meters long)
Material and Labour for PCC foundation for fixing of Steel tubular pole as per laid procedure including all earth work, all as specified and as directed
Supply and Fixing in repairs Street light fitting, LED street light fitting made of pressure die casting cast aluminium housing with heat resistant toughened glass and IP66 protection of 90 watts capacity including LEDs including all necessary fitting accessories and prewired complete all as specified and as directed. Make : Crompton Greaves, Model : ORION NEO, CAT REF : LST-90-CDL-M or equivalent of Havells / Wipro / Bajaj
Supply and fixing in repairs, LED Street light fittings 45 Watts AC, 230 Volts, 50 HZ supply single phase including connection with PVC copper conductor cable of suitable size to fitting all as specified and as directed of Make : CG, MODEL : FREEDOM NEO, CAT REF : LSTS -30- CDL -M or equivalent
Supply and fixing in repairs, LED Street light fittings 72 Watts AC, 230 Volts, 50 HZ supply single phase including connection with PVC copper cable of suitable size to fitting all as specified and as directed of Make : CG, MODEL : NEXUS NEO, CAT REF : LSTS -72- CDL -M or equivalent
Supply and fixing in repairs, LED Street light fittings 120 Watts AC, 230 Volts, 50 HZ supply single phase including connection with PVC copper cable of suitable size to fitting all as specified and as directed of Make : CG, MODEL : NEXUS STAR NEO, CAT REF : LSTP -120- CDL -M or equivalent
Supply and fixing in repairs, LED Street light fittings 180 Watts AC, 230 Volts, 50 HZ supply single phase including connection with PVC copper cable of suitable size to fitting all as specified and as directed of Make : CG, MODEL : HAWK NEO, CAT REF : LSTP -180- CDL -M or equivalent
M & L for two single core PVC insulated unsheathed , 1100 Volts grade, copper cable 1.50 sqmm multistranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size but not less than 25mm dia with conduit accessories etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 1.00 sqmm copper conductor fixed to poles with saddles and screws and all as specified and as directed by Engr-in-Charge. Note :- One run of PVC conduit, two runs of cable 1.50 sqmm and one run of earth wire 1.00 sqmm shall be measured and paid as one unit.
Supply & Laying in trenches, fixed on walls, passing through pipes, jpointing and testing of electric cables, XLPE insulated, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 volts grade for the following sizes 4 Core 25 Sqmm
Supply & Laying in trenches, fixed on walls, passing through pipes, jpointing and testing of electric cables, XLPE insulated, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 volts grade for the following sizes 4 Core 35 Sqmm
Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for laying cables in soft/loose soil.
Returning filling in, inluding, spreading, leveling, watering and well ramming in layers n exc. 25 cm.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point.
Supply and filling of Sand under trenches for cable protection
Supply and filling of Bricks of size 230x 113x 75 mm under trenches for cable protection
S & Replacement of GI bracket for street lights made out of light grade GI pipe 50mm dia, 3.0 mtr long bend to shape as directed, fixed on poles with MS clamp flat iron suitable for RCC rectangular/steel tubular pole with nuts, bolts and washers and all as specified and directed.
M & L for sub main wiring with four single core PVC insulated unsheathed , 1100 Volts grade, copper cable 4x10.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, 2 run of cable 6 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit, Six runs of cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with four single core PVC insulated unsheathed , 1100 Volts grade, copper cable 4x6.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, 2 run of cable 4 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit, Six runs of cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with four single core PVC insulated unsheathed , 1100 Volts grade, copper cable 4x4.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, 2 run of cable 2.50 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit, Six runs of cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with four single core PVC insulated unsheathed , 1100 Volts grade, copper cable 4x2.5 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, 2 run of cable 1.50 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit, Six runs of cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x10.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade, One run of copper cable 6.00 sqmm copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of cable and one run of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x6.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 4.00 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 6.00 sqmm cable and one run of 4.00 sqmm of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x4.0 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 4.00 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 4.00 sqmm cable and one run of 2.50 sqmm of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x2.5 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 1.50 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 2.50 sqmm cable and one run of 1.50 sqmm of earth wire shall be measured and paid as one unit.
M & L for sub main wiring with single core PVC insulated unsheathed , 1100 Volts grade, copper cable 2x1.5 sq. mm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,One run of 1.50 sqmm cable copper conductor and connected to common earth dolly complete as directed including taking down old submain wiring Note :-(i) One run of PVC conduit two runs of 2 X 2.50 sqmm cable and one run of 1.50 sqmm of earth wire shall be measured and paid as one unit.
Supply and fixing in repairs sheet metal enclosure powder coated, Distribution boards VTPN MCCB 250 A DB, double door, Provision of TPN MCCB 250 Amps, 25ka as Incomer, 6 way, 415V, Double door type IP 43 protection, shrouded Neutral Bar & Pan assembly with flexible link Cement spill protector, Door earthing, complete Make INDOASIAN, Model Optipro F2+ 18 CAT REF : 811895 or equivalent of HAVELLS/ L & T/ LEGRAND
Supply and fixing in repairs Modular Switch 6 A,230 Volts
Supply and fixing in repairs Modular Switch 16 A,230 Volts
Supply and fixing in repairs Modular Socket, 2/3 pin Combined 6 A,230 Volts
Supply and fixing in repairs Modular Socket, 2/3 pin Combined 16 A,230 Volts
Supply and fixing in repairs Switch piano, flush type single pole, one way 5 Amp
Supply and fixing in repairs Switch piano, flush type single pole, one way 15 Amp
Supply and fixing in repairs Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type universal
Supply and fixing in repairs Switch socket combination 2 in 1, 3 pin, 5 Amp, flush type universal
Taking down Ceiling fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and painting one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different location and connection complete from ceiling rose with new flexible copper cable of suitable size, testing commissioning after completion of the work. Note : The accessories such as bearing and capacitor will be measured as supply only.
Taking down exhaust fan of any make/model and sweep for ovehauling/servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and painting one coat of synthetic enamel paint of approved quality and colour (spray painted) after preparing the surface throughly and refixing at site at same/different location and connection complete from ceiling rose with new flexible copper cable of suitable size, testing commissioning after completion of the work. Note : The accessories such as bearing and capacitor will be measured as supply only.
M&L for rewinding of ceiling fan of any make/model/sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tapping the winding and applying air drying the winding throughly and all as specified and directed.
M&L for rewinding of Exhaust fan of any make/model/sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tapping the winding and applying air drying the winding throughly and all as specified and directed.
M&L for rewinding of Wall mounted fan of any make/model/sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tapping the winding and applying air drying the winding throughly and all as specified and directed.
Supply & fixing in Repair/ replacement of Capacitor 2.5mfd 440/500 Volts suitable for ceiling fan, Make : Havells or Equivalent make in CG/Bajaj/Philips
Supply & fixing in Repair/ replacement Ball bearing (6201/6202/6203) suitable for ceiling fan of 1200/1400mm sweep.
Supply in fixing in repairs LED light 15 watts, Round recess mounted, slim down light, die cast aluminium housing, Make : CG, Model : PEARL ULTIMA R, CAT REF LSCRM-15W-CDL
Supply in fixing in repairs LED light 15 watts, Round recess mounted, slim down light, die cast aluminium housing, Make : CG, Model : PEARL ULTIMA S, CAT REF LSCRM-15W-CDL
S&F in repairs LED light 20 watts, slim down light durable LED batten with decorative end caps, TRIMLINE, CAT REF : LDL-20-NW Make : CG
S&F in repairs LED light 2' X 2' watts, 36 Watts, Model : AURA I, CAT REF : CCR-127-36-57-SL-NWH ( 2 X 2 ) Make : CG
Supply and fixing in repairs Flourescent tube rod 36 watts
Perodical checking & testing, normal and routine maintenance including cleaning of all parts and carry out corrective maintenance, attending to complaints on call repair and replacement of spares for fire alarm system of make and model for the following areas at ADE and all as specified and directed and specified( Periodical will be checked by quaterly in a year)
(i) SANCHAR Building : Fire alarm panel servicing and clearing faults, checking cable continuity, troubled sensor servicibility of parts Sensor's/MCP's/Hooter's/ RI's batteries etc.
(ii) USD Building : Fire alarm panel servicing and clearing faults, checking cable continuity, troubled sensor servicibility of parts Sensor's/MCP's/Hooter's/ RI's batteries etc.
(iii) SIMULATION Building : Fire alarm panel servicing and clearing faults, checking cable continuity, troubled sensor servicibility of parts Sensor's/MCP's/Hooter's/ RI's batteries etc.
(iv) Falcon Building : Fire alarm panel servicing and clearing faults, checking cable continuity, troubled sensor servicibility of parts Sensor's/MCP's/Hooter's/ RI's batteries etc.
Note : Spares required to maintain the fire alaram system will be measured and paid seperately.
Perodical checking & testing, normal and routine maintenance including cleaning of all parts and carry out corrective maintenance, attending to complaints on call repair and replacement of spares for fire alarm system of make and model for the following areas at DEBEL and all as specified and directed and specified
(i) DEBEL Old Building : Fire alarm panel servicing and clearing faults, checking cable continuity, troubled sensor servicibility of parts Sensor's/MCP's/Hooter's/ RI's batteries etc.
(ii) DEBEL New Building : Fire alarm panel servicing and clearing faults, checking cable continuity, troubled sensor servicibility of parts Sensor's/MCP's/Hooter's/ RI's batteries etc.
Supply and fixing in repairs Conventional Smoke Detector with Baselow profile design,Low current draw, Wide opening voltage 8 to 30 V DC, Bi - colour LED detectorstatus indicator, tested and approved to EN54. Make : System Sensor, 2351E
Supply and fixing in Repairs Conventional manual call point,Break glass unit, Alaram status is indicated by Red Colour LED, 24 DC.
Supply and fixing in Repairs Conventional Hooter, Wall mount, 24 v dc, operating current 40mA, Piezo Electric Type.
Supply and fixing in Repairs Battery 12V, 7AH MAKE : EXIDE
Supply and fixing in Repairs Conventional Response Indicators 24 V DC
Supply and fixing 2 Core x 1.50 Sq. mm sheathed cable with PVC insulated with multi strand heavy duty copper conductor cable.
Supply and fixing 19mm PVC conduit wit accessories.
Supply and fixing in repairs Electric/Zone /Module unit cards
Supply, Test, Install and Commissioning of Repeater Control Panel
Repairs to the Fire Alaram system by Servicing/ Caliberation
Servicing/ Caliberation Manual Call Point : Checking the circuits, glass LED etc.
Servicing/ Caliberation Manual Call Points
Caliberation and functioning of the Smoke detectors by cleaning the Sensing chamber and LED fuses and wiring circuits Etc.
Caliberation and functioning of the Hooters by cleaning the Sensing chamber and LED fuses and wiring circuits Etc.
AishwaryaConstructions
Prashanth Associates
GURU ENTERPRISES
SAI CONSTRUCTIONS
RAHUL ENTERPRISES
R R Constructions
Siddivinayaka Constructions
Varsha Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .