Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹2.4 L+₹5,760 (2.49%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest | |
| 3 | L3₹2.4 L+₹8,597 (3.72%)Accepted-Finance | L3 | Accepted-Finance 3rd Lowest | |
| 4 | L4₹2.4 L+₹9,026 (3.91%)Accepted-Finance | L4 | Accepted-Finance 4th Lowest | |
| 5 | L5₹2.4 L+₹10,850 (4.70%)Accepted-Finance | L5 | Accepted-Finance 5th Lowest |
Tender Value
₹2.4 L
EMD Value
₹4,798
Closing Date
20 May 2022, 10:00 amClosed
EE WSD APWD
EE WSD APWD Port Blair
Renovation of IEI and EEI to 01 Nos. Type III Qtr. No. DT 5 near Dilthaman Tank , Port Blair
2022_APWD_5933_1
30/NIT/WSD/2022-23
Open Tender
Electrical Works
Works
7 days
Port Blair
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹4,798
22 Jun 2022
12 May 2022
20 May 2022
12 May 2022
20 May 2022
13 May 2022
12 May 2022 - 20 May 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, suitable size plastic switch board and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
Group B
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, suitable size plastic switch board and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing the following way plastic switch board (ISI marked) on surface:
1 way ( Make: Press Fit, Code : 563051 or equivalent)
2 way ( Make: Press Fit, Code : 563051 or equivalent)
2 way, 16A ( Make: Press Fit, Code : 563121 or equivalent)
4 way ( Make: Press Fit, Code : 563101 or equivalent)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing 100 W, Deluxe Fan Regulator Rotary Step (Socket Type ) (Make: Anchor, Code : 14502 or equivalent) on the existing switch board including connections etc. as required.
Supplying and fixing of 12W LED recessed downlight CDL/NW/WW with die cast aluminium housing with minimum efficacy of 100 lm/w ( Make: Crompton, Model: Pearl Ultima-S, Cat No.: LSCRM-12W-CDL/LSCRM-12W-NW/LSCRM-12W-WW or equivalent) including connection etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying of Wall Light suitable for 1x B22 LED lamp (Make: Havells, Model : Sana or equivalent ).
Supplying and fixing the following LED lamp on the existing batten/angle holder/Wall Light:
9W, B22 LED lamp, CDL/WW ( Make : Havells or equivalent )
5W, B22 LED lamp, CDL/WW ( Make : Havells or equivalent )
Supplying and fixing Door Bell suitable for single phase, 230 V (Make: Anchor, Model: Penta Door Bell, Model No.: 38921 or equivalent ).
Supplying of LED Bulk Head of wattage between 9 W/ 10 W with PDC housing and IP65/ IP66 Protection, CW/NW/WW (Make:-Philips, Model : Endura or equivalent ) including connection etc. as required.
Installation ,Testing, Commissioning of all LED wall bracket /ceiling fittings of all sizes and shapes , complete with all accessories including connections etc. as required.
Supplying of energy saving BLDC A.C. Ceiling fan of 1200 mm sweep of approved colour suitable for operation on 230 volts, single phase, 50 Hz, AC supply with all accessories as required (Make: Orient, Model: Hector-500 or equivalent).
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying of exhaust fan of 230 mm sweep (Metallic ) (Make: Usha, Model: Aeroclean LD GBD or equivalent).
Supplying of exhaust fan of 150 mm sweep (Non Metallic ) (Make: Usha, Model : Crisp Air or equivalent).
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way , Double door
Supplying and fixing 4 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar (Make: Havells, Cat. No.: DHDNSHODAW04 or equivalent), interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying of 6 sq.mm., 2- core XLPE insulated armoured LT power cable of 1.1kV grade with aluminium conductor (Make: Havells or equivalent).
Supplying and laying of DWC HDPE pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complets with fitting and cutting, jointing etc. direct in ground (50 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.
Supplying and laying of DWC HDPE pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complets with fitting and cutting, jointing etc. direct in ground (50 cm below ground level including hard surface) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.
40 Supplying and laying of DWC HDPE pipe of size 40/32, ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 16205 ( Part 24 ), 2018 ( Old IS 14930, Part 2,2001 ) complete with fitting and cutting, jointing etc. directly on surface as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing DWC pipe as required. a) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface as required. a) Upto 35 sq. mm
Supplying of fabricated metallic pole of length of 5.0 meters made out of 80 mm. dia. G.I pipe of length 2.00 mtrs and 65 mm. pipe dia. G.I. pipe of length 3.00 mtrs. having single arm made out of 40 mm. dia. G.I. pipe of length 0.8 mtrs. for fixing Street Light and provision for fixing Cable Junction Box , painting with water proof paint of approved colour over a coat of metal primer etc. including cost of materials, labour etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
a) Above 4.5 metre and upto 6.5 metre
Supplying and fixing of SMC Junction Box, IP 44 (Make : Sintex,, Cat No. : GSJB-1414 or equivalent ) with a two pole connector and 6 A MCB, on the existing street light pole including connection etc. as required.
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
NAVJEEVAN ENTERPRISES
JAY ENGINEERING
M K ENGINEERING
DAYAL HALDER
M/s Island Sales Enterprises
S SAMATHANAM
pss Electrical works
JOY GURU ENTERPRISES
ICONAGENCIES
M/s G K Construction
POWER ENGINEERING CO
M/s Sameer Decorative Corner
DILIP RAJ
MILESTONE ENGINEERING
RAVI RAJ ELECTRICALS
C. KUMAR
BLUE CHIP CONSULTANCY SERVICE
M/s Sai Electrical Works
Yuvika Enterprises
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .