| 1 | L1₹25.2 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.9 L+₹2.7 L (10.8%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹29.7 L+₹4.6 L (18.1%)Rejected-Finance MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹31 L+₹5.8 L (23.3%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹33.4 L+₹8.2 L (32.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | Bharat Enterprises L5 | PAUL TRADERS L12 | VARDHMAN INTERNATIONAL L11 | slathia construction works L1 | M/s SS Engineering Enterprises L9 | M/s Trade Linker Associates L2 | M/S KIRAN CONSTRUCTIONS L3 | MOHAN LAL AND SONS L7 | PROACH ASSOCIATES BUILDERS & ENGINEERS L10 | FANGALIA TRADERS L8 | vijay kumar gupta and co L4 | jaima electricals L6 | ATUL TRADING CO L13 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply Installation testing and commissioning Of retrofit emission control device for diesel generator of any make/ vintage /Category, complete all as specified and directed by Engr-in-Charge :- Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine of DG sets up to 320 KVA as per CPCB-II Norms. Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets. Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. b) Construction of suitable earthing station and necessary connections shall be done by the seller. c) Warranty/Service :- 12 months d) Number of preventive maintenance visits offered in a year during warranty period :- 2 visits Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set). | ||||||||||||||||
| 1.01TEST REPORTS Certification :- The device must be 'Type Approved' in accordance with the Central Pollution Control Board's System and Procedure for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines, dated 01/02/2022, as well as provide a type testing certificate for all KVA families of required generators. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): | ||||||||||||||||
| 1.02General Technical Requirments(GTR)/Commissioning:- a) Emission control retrofit device shall be complete with safety precution to ensure no damage should be done to the DG set operations under anycircumstance.The Emission control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through theEmission control retrofit device. b) Anti vibration mountings shall be provided for complete Emission control retrofit device in case of flaxible coupling with the DG exhaust c) Emission control retrofit device should have protection against under voltage,over voltage,under frequency ,over frequency,lowbattery voltage,over current,earth fault,short circuit ,phase sequence change etc d) The Emission control retrofit device shall be with cirrosion resistive and HR paint. e) Unloading and placement of the Emission control retrofit device at the time of delivery is in the scope of work. | ||||||||||||||||
| 1.03(f) The contractor shall provde detailed Pollution test report for DG sets for pre and post installation of Restrofit Emission control Device (RECD) from NABL approved lab. g) All exhaust piping ,any extra work, distribution board shall be provided by the contractor in the scope of work (h) RECD manufacturer/OEM shall becertified from one of five currently CPCB reconginzed/Approved labsl applicable to Phase-I & phase-II DG sets and the contractor shall submit mandatorty "Type approval' certificate as received by RECD manufacturer/OEM from CPCB reconginzed/ approved labs before installation of RECD over the DG sets. | ||||||||||||||||
| 2.00 | Description all as per item No. 1.00 above here-in-before but of 320 KVA, complete all as specified and directed by Engr-in-Charge | 1 | Each Job | 5,91,600 ₹5,91,600 | 7,90,000 ₹7,90,000 | 8,80,000 ₹8,80,000 | 5,12,000 ₹5,12,000 Lowest | 8,35,000 ₹8,35,000 | 5,45,000 ₹5,45,000 | 5,30,000 ₹5,30,000 | 6,88,000 ₹6,88,000 | 7,22,000 ₹7,22,000 | 6,50,000 ₹6,50,000 | 5,90,000 ₹5,90,000 | 7,00,000 ₹7,00,000 | 9,50,000 ₹9,50,000 |
| 3.00 | Description all as per item No. 1.00 above here-in-before but of 250 KVA, complete all as specified and directed by Engr-in-Charge | 3 | Each Job | 4,87,800 ₹14,63,400 | 6,50,000 ₹19,50,000 | 7,25,000 ₹21,75,000 | 4,00,000 ₹12,00,000 Lowest | 5,50,000 ₹16,50,000 | 4,22,000 ₹12,66,000 | 4,65,000 ₹13,95,000 | 5,40,000 ₹16,20,000 | 5,98,000 ₹17,94,000 | 5,30,000 ₹15,90,000 | 4,90,000 ₹14,70,000 | 4,70,000 ₹14,10,000 | 7,50,000 ₹22,50,000 |
| 4.00 | Description all as per item No. 1.00 above here-in-before but of 125 KVA, complete all as specified and directed by Engr-in-Charge | 2 | Each Job | 2,52,000 ₹5,04,000 | 4,50,000 ₹9,00,000 | 3,55,000 ₹7,10,000 | 2,00,000 ₹4,00,000 Lowest | 3,25,000 ₹6,50,000 | 2,12,000 ₹4,24,000 | 2,29,000 ₹4,58,000 | 2,65,000 ₹5,30,000 | 4,48,000 ₹8,96,000 | 2,90,000 ₹5,80,000 | 2,40,000 ₹4,80,000 | 2,50,000 ₹5,00,000 | 4,50,000 ₹9,00,000 |
| 5.00 | Description all as per item No. 1.00 above here-in-before but of 63 KVA, complete all as specified and directed by Engr-in-Charge | 4 | Each Job | 1,94,600 ₹7,78,400 | 3,10,000 ₹12,40,000 | 2,00,000 ₹8,00,000 | 1,00,800 ₹4,03,200 Lowest | 1,80,000 ₹7,20,000 | 1,38,000 ₹5,52,000 | 1,47,000 ₹5,88,000 | 1,39,000 ₹5,56,000 | 2,18,000 ₹8,72,000 | 2,20,000 ₹8,80,000 | 1,40,000 ₹5,60,000 | 1,90,000 ₹7,60,000 | 1,97,000 ₹7,88,000 |
Tender Value
₹50.0 L
EMD Value
₹99,960
Closing Date
10 Jan 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur Po-Garhi Pin-182121
Repair Fitment of Retro Fit Emission Control Devices for DG sets in Northern Part of Garrison under GE Utilities Udhampur
2025_MES_745483_1
GE/U-80/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹99,960
27 Jan 2026
20 Dec 2025
12 Jan 2026
20 Dec 2025
10 Jan 2026
3 Jan 2026
Amount
Supply Installation testing and commissioning Of retrofit emission control device for diesel generator of any make/ vintage /Category, complete all as specified and directed by Engr-in-Charge :- Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine of DG sets up to 320 KVA as per CPCB-II Norms. Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets. Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. b) Construction of suitable earthing station and necessary connections shall be done by the seller. c) Warranty/Service :- 12 months d) Number of preventive maintenance visits offered in a year during warranty period :- 2 visits Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set).
TEST REPORTS Certification :- The device must be 'Type Approved' in accordance with the Central Pollution Control Board's System and Procedure for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) for Diesel Power Generating Set Engines, dated 01/02/2022, as well as provide a type testing certificate for all KVA families of required generators. Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar):
General Technical Requirments(GTR)/Commissioning:- a) Emission control retrofit device shall be complete with safety precution to ensure no damage should be done to the DG set operations under anycircumstance.The Emission control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through theEmission control retrofit device. b) Anti vibration mountings shall be provided for complete Emission control retrofit device in case of flaxible coupling with the DG exhaust c) Emission control retrofit device should have protection against under voltage,over voltage,under frequency ,over frequency,lowbattery voltage,over current,earth fault,short circuit ,phase sequence change etc d) The Emission control retrofit device shall be with cirrosion resistive and HR paint. e) Unloading and placement of the Emission control retrofit device at the time of delivery is in the scope of work.
(f) The contractor shall provde detailed Pollution test report for DG sets for pre and post installation of Restrofit Emission control Device (RECD) from NABL approved lab. g) All exhaust piping ,any extra work, distribution board shall be provided by the contractor in the scope of work (h) RECD manufacturer/OEM shall becertified from one of five currently CPCB reconginzed/Approved labsl applicable to Phase-I & phase-II DG sets and the contractor shall submit mandatorty "Type approval' certificate as received by RECD manufacturer/OEM from CPCB reconginzed/ approved labs before installation of RECD over the DG sets.
Description all as per item No. 1.00 above here-in-before but of 320 KVA, complete all as specified and directed by Engr-in-Charge
Description all as per item No. 1.00 above here-in-before but of 250 KVA, complete all as specified and directed by Engr-in-Charge
Description all as per item No. 1.00 above here-in-before but of 125 KVA, complete all as specified and directed by Engr-in-Charge
Description all as per item No. 1.00 above here-in-before but of 63 KVA, complete all as specified and directed by Engr-in-Charge
M/s Trade Linker Associates (BID ID -3521080)
M/S KIRAN CONSTRUCTIONS (BID ID -3521276)
vijay kumar gupta and co (BID ID -3520656)
Bharat Enterprises (BID ID -3520396)
jaima electricals (BID ID -3521374)
MOHAN LAL AND SONS (BID ID -3521334)
FANGALIA TRADERS (BID ID -3520784)
M/s SS Engineering Enterprises (BID ID -3521043)
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3519430)
VARDHMAN INTERNATIONAL (BID ID -3520686)
PAUL TRADERS (BID ID -3520491)
ATUL TRADING CO (BID ID -3520214)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TENDER80.pdf
Tender Documents • 1.29 MB
BOQ_834749.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .