Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.7 L+₹14,028 (1.85%)Rejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹7.8 L+₹21,780 (2.88%)Rejected-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L3 | Rejected-Finance 3rd Lowest Bidder | |
| 4 | Rejected-Technical 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | - | Rejected-Technical Insufficient Documents. |
| Sl No | Description | Qty | Unit | ANIKET COOLING AND REFRIGERATION CO L2 | Shinryo Suvidha Engineers India Pvt. Ltd. L3 | P. M. COOLING AND ENGINEERING CO L1 |
|---|---|---|---|---|---|---|
| 1.00Day to day Comprehensive routine & Preventive Maintenance of different Air- Conditioning system installed at Tamralipta Govt.Medical college and Hospital , Tamluk , Purba Medinipur. | ||||||
| 1.01 | 1.0 Tr.split type AC Machine.- [AC m/c quantity- 06 nos. machine X 12 Month= 72 Nos ] | 72 | Nos. | 245 ₹17,640 | 250 ₹18,000 | 240 ₹17,280 Lowest |
| 1.02 | 1.5 Tr. Split type AC Machine. [AC m/c quantity- 60 nos. machine X 12 Month= 720 nos] | 720 | Nos. | 250 ₹1,80,000 Lowest | 260 ₹1,87,200 | 250 ₹1,80,000 Lowest |
| 1.03 | 2.0 Tr. Split type AC Machine. [AC m/c quantity- 53 nos. machine X 12 Month= 636 nos] | 636 | Nos. | 285 ₹1,81,260 | 290 ₹1,84,440 | 275 ₹1,74,900 Lowest |
| 1.04 | 1.5 Tr. Window type AC Machine. [AC m/c quantity- 28 nos. machine X 12 Month= 336 nos] | 336 | Nos. | 278 ₹93,408 | 275 ₹92,400 Lowest | 275 ₹92,400 Lowest |
| 1.05 | 2.0 Tr. Window type AC Machine. [ AC m/c quantity- 09 nos. machine X 12 Month=108 nos] | 108 | Nos. | 325 ₹35,100 | 320 ₹34,560 Lowest | 320 ₹34,560 Lowest |
| 1.06 | 5.5 Tr. Ductable Split type AC Machine. [ AC m/c quantity- 08 nos. machine X 12 Month= 96 nos] | 96 | Nos. | 1,550 ₹1,48,800 | 1,500 ₹1,44,000 | 1,480 ₹1,42,080 Lowest |
| 1.07 | 11 Tr. Ductable Split type AC Machine. [ AC m/c quantity- 04 nos. machine X 12 Month= 48 nos] | 48 | Nos. | 2,380 ₹1,14,240 Lowest | 2,450 ₹1,17,600 | 2,400 ₹1,15,200 |
| 2.00SCOPE OF WORK AND TERMS & CONDITION:- | ||||||
| 2.01A) Routine checking and servicing (Preventive maintenance). i) Checking & servicing of all mechanical & electrical parts of the A.C.Machine, refrigerant system, condenser & cooling system etc. three times in each month. ii) Checking of performance of each machine, Load Current (Amp) , CFM, grill temperature¸ room temperature etc. on daily basis & these shall be noted, in Log Book. All entries be countersigned by the Agency and the concerned Junior Engineer in the Log Book. iii) In every month, the Outdoor unit should be thoroughly cleaned and washed by vacuum cleaner and jet spray. iv) All machine shall be numbered according to their location, made and as per direction of E.I.C & Log book be maintained accordingly. v) Cleaning of filters twice in each month. vi) Lubricating the bearing of the motor & fan as and when required vii) Checking the electrical incomer upto incoming M.C.B incl. starter, switches etc. in each month. Any fault located should be brought to the notice of the Asstt. Engineer & Junior Engineer immediately. viii) Checking & repairing of all parts which have not been specified but necessary to keep the machine satisfactory running condition. ix) Agency must be provide a trained attender for operation of ductable type AC machine. x) If any fire hazard occurred due to poor maintenance of the Split/Window/ductable split Air Conditioning machine, the liability will goes to solely on the concerned maintenance agency. | ||||||
Tender Value
Refer Docs
EMD Value
₹15,569
Closing Date
22 Jul 2025, 2:30 pmClosed
O/O THE SENIOR SUPERINTENDING ENGINEER,SWEC,PWD
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur
Day to day comprehensive routine and Preventive Maintenance of different AirConditioning system installed at Tamralipta Govt.Medical college and Hospital, Tamluk, Purba Medinipur.
2025_WBPWD_878914_1
WBPWD/SSE/SWEC/NIQ02/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
365 days
TAMLUK, PURBA MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,569
O/O THE SENIOR SUPERINTENDING ENGINEER,SWEC,PWD
29 Sept 2026
15 Jul 2025
24 Jul 2025
15 Jul 2025
22 Jul 2025
17 Jul 2025
17 Jul 2025
Amount
Day to day Comprehensive routine & Preventive Maintenance of different Air- Conditioning system installed at Tamralipta Govt.Medical college and Hospital , Tamluk , Purba Medinipur.
1.0 Tr.split type AC Machine.- [AC m/c quantity- 06 nos. machine X 12 Month= 72 Nos ]
1.5 Tr. Split type AC Machine. [AC m/c quantity- 60 nos. machine X 12 Month= 720 nos]
2.0 Tr. Split type AC Machine. [AC m/c quantity- 53 nos. machine X 12 Month= 636 nos]
1.5 Tr. Window type AC Machine. [AC m/c quantity- 28 nos. machine X 12 Month= 336 nos]
2.0 Tr. Window type AC Machine. [ AC m/c quantity- 09 nos. machine X 12 Month=108 nos]
5.5 Tr. Ductable Split type AC Machine. [ AC m/c quantity- 08 nos. machine X 12 Month= 96 nos]
11 Tr. Ductable Split type AC Machine. [ AC m/c quantity- 04 nos. machine X 12 Month= 48 nos]
SCOPE OF WORK AND TERMS & CONDITION:-
A) Routine checking and servicing (Preventive maintenance). i) Checking & servicing of all mechanical & electrical parts of the A.C.Machine, refrigerant system, condenser & cooling system etc. three times in each month. ii) Checking of performance of each machine, Load Current (Amp) , CFM, grill temperature¸ room temperature etc. on daily basis & these shall be noted, in Log Book. All entries be countersigned by the Agency and the concerned Junior Engineer in the Log Book. iii) In every month, the Outdoor unit should be thoroughly cleaned and washed by vacuum cleaner and jet spray. iv) All machine shall be numbered according to their location, made and as per direction of E.I.C & Log book be maintained accordingly. v) Cleaning of filters twice in each month. vi) Lubricating the bearing of the motor & fan as and when required vii) Checking the electrical incomer upto incoming M.C.B incl. starter, switches etc. in each month. Any fault located should be brought to the notice of the Asstt. Engineer & Junior Engineer immediately. viii) Checking & repairing of all parts which have not been specified but necessary to keep the machine satisfactory running condition. ix) Agency must be provide a trained attender for operation of ductable type AC machine. x) If any fire hazard occurred due to poor maintenance of the Split/Window/ductable split Air Conditioning machine, the liability will goes to solely on the concerned maintenance agency.
B) Overhauling: i) Through overhauling of the machine part by part twice in a year. ii) Cleaning & painting of the machine body, base tray etc. once in a year. iii) Cleaning & discalling of condenser unit, cooling coil etc. and gas leak test once & when required in a year. iv) Overhauling shall preferably be done during winter season and must be noted in the Log Book.
C) Supply & Repairing: This comprehensive contract covers preventive & corrective maintenance of A.C. machine/ spare parts as required so as to keep the A.C. machine operative/ functioning round the clock and for ensuring uninterrupted & trouble - free performance of the equipment. i) Replenishing refrigerant required as a result of a leak in system arising out of fair wear & tear as per requirement. ii) Supply of refrigerant shall be made as & when required by the Agency in his own cost for all AC Machine.. iii) Repair of microprocessor controls & to be replaced free of cost for all AC Machine. iv) Replacement capacitor (P2 type) incl. of all spare parts, including compressors (Except Ductable Split type AC machine), shall be made by the Agency for smooth running of the machine at his cost for all AC Machine. v) Filters be changed except nylon filter once in a year & the new once shall be approved by the EIC. vi) Replace/ repair of all spare parts of ductable split type (Like- Refrigerent, blower motor, remote sensing unit, controler, ducting, damper unit, all kind of valve, communication card, contactor and other electrical accerise etc) are to be made agency own cost. vii) No major parts shall be removed without permission of concerned Asstt. Engineer. Challan shall be obtained from Junior Engineer while taking away machine or parts from site for repairing and materials shall be returned/ repaireed within three days to worksite in Co’s challan.
D) Attendance of break down: i) Break downs to be attended by experienced AC machines immediately after receiving initiation from the Junior Engineer, Asstt. Engineer and the authority concerned. ii) AC machine must be provided with cell phone with contact no. iii) Nature of break down with date shall be recorded in the Log Book.
E) TERMS & CONDITION. i) All payments shall be made as per Govt. rules. ii) Agency may raise bills for quarterly payment. He shall submit service challan and Monthly Log Sheet (Format given by department) duly filled & countersigned by the Junior Engineer,& Asstt. Engineer mentioning therein the performance of the machine with grill temperature, room temperature at the time of servicing along with the log book duly signed by the JE & AE concerned. iii) No extra payment shall be made for repairing & replacement of machine parts or refrigerant. iv) The Log Book shall be kept upto-date & ready at Junior Engineer Chamber for verification by higher authority at any time & to be produced whenever demanded by the EIC for verification. v) The Executive Engineer reserves the right to terminate the contract at any time with one month notices. vi) If the Agency fails to make a break down machine operational with in 24 Hrs. or fails to provide replacement of the machine from his own working machine (loan machine), deduction from the bill will be made @`20/- for each day for split machine @ 200/- for each day for ductable type AC machine in excess of 24 Hrs.
ANIKET COOLING AND REFRIGERATION CO (BID ID -6752047)
Shinryo Suvidha Engineers India Pvt. Ltd. (BID ID -6752104)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .