Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.7 L+₹2.7 L (6.21%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹46.9 L+₹3.9 L (9.05%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹47.1 L+₹4.1 L (9.48%)Rejected-Finance 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹47.4 L+₹4.4 L (10.2%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹44.5 L
EMD Value
₹89,065
Closing Date
28 Aug 2023, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
PROVN OF FALSE CEILING IN NEW FLY CATCHER ROOM OF 509 VBW AND PROVN OF 01 X SECURITY LIGHT WITH 4 X FLOOD LIGHT OF 100 WATT, 12.5 MTR HEIGHT WITH CABLE AT VEH PARKING AREA OF 622 PARA COY ASC (CAMP) INCLUDING CERTAIN MINOR WORKS UNDER GE (EAST) AGRA
2023_MES_612433_1
9563/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹89,065
Yes
21 Sept 2023
7 Aug 2023
4 Sept 2023
7 Aug 2023
28 Aug 2023
21 Aug 2023
Amount
Surface excavation, n.exc 30 CM deep and avg 15 cm, getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth as in foundation etc as in soft/loose of soil complete all as specified and directed.
M&L PCC Type D2 (1:4:8) using 40mm graded stone agg as in foundation filling mass concrete complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm as in soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point with soil complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in foundation, raft, footing, plinth beam, base for column etc complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in column complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in roof beams, chajja, lintle etc complete all as specified and directed.
M&L RCC M-25 (20 mm graded stone aggregate) as in slabs supported on walls, beams and column in floors, roof, landings, balconies, canopies, deck slab and in shevels/chajja the like complete all as specified and directed.
M&L Formwork to side of concrete foundation footing base of column raft beam and plinth beam with required gap filler etc complete all as specified and directed.
M & L form work to side/bottom of pillars , post , column, beam, slab square, rectangular or polygonal required gap filler etc complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M& L form work to sofits of suspended slabs such as roof slabs, floors slabs, landings/chajja and similar work not exceeding 200mm thick (horizontal or sloping) for fair finished surfaces of concrete required gap filler complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work for fair and smooth surface exc 10cm but n.exc 20cm wide complete all as specified and directed.
S&F mild steel bars 10 mm dia and over (TMT) cut to length bent to shape required including cracking, bending spirally for hooping ends and binding with and including mild steel wire not less than 0.90 mm dia quality of steel conforming to Fe-410-0 or Fe-410-S complete all as specified and directed.
S&F mild steel bars 5 mm dia and over up to 10 mm dia in stirrups space and binders. (TMT) cut to length bent to shape required including cracking, bending spirally for hooping ends and binding with and including mild steel wire not less than 0.90 mm dia quality of steel complete all as specified and directed.
M&L hardcore of gauge exc.63 mm but not exc 100 mm deposited, spread and levelled in layers n exc. 15 CM thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed.
M&L12 mm Rendering with CM (1:6) over brick/concrete surface other than surface fair & even surface complete all as specified and directed.
M&L15mm Rendering incl WPC with CM (1:4) over brick/concrete surface finished even & fair complete all specified and directed. ( Note :- WPC shall be measured Sparely).
All as per item 21.00 above but 10 mm thickness (1:3) on ceiling complete all as specified and directed.
All as per item No 21.00 above but other than fair face of brick work complete all as specified and directed.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffener and fixed with 100 x 8 sheet metal CSK screws complete all as specified and directed and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
M&L for Factory made soild PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40 x 20 x19 of MS pipe as stiffener & supplying & fixing in frame at site as per specifications & drawing complete all as specified and directed.
S & F steel ventilators with top hung shutter & glazing bars hinges, steel peg stay etc dovetailed or welded, size and thickness of members confirming to IS 1038 complete all as specified and directed.
M&L 3mm thick ordinary quality sheet glass and glazing with oil putty and clip pin in square not exc 0.5 Sqm in each pane complete all as specified and directed.
Supply & fix stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture1.40 fixed in aluminium windows or along with 'F' section complete all as directed by EIC complete all as specified and directed.
M&L two coat of synthetic enamel paint on new prepared steel surface over a coat of red oxide primer complete all as specified and directed.
S&F Aluminium butt hinges of 100mm size type C-22 complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt of 200 mm of extruded section complete all as specified and directed.
S&F 250mm long aluminium alloy anodised, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F aluminium, anodised handle cast type of size125 mm complete all as specified and directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles 450X 300X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C1 using 20mm graded stone agg as in plinth protection/Path/paving surface even and smooth and exposed edges fair or rounding or chamfering laid in panels with and including all necessary form work and filling the joints with mastic filling of one part of hot bitumen 85/25 grade and three part of fine sand (all by weight) complete all as specified and directed.
M&L Two coats of cement base paint over a coat of primer on new prepared wall surfaces complete all as specified and directed.
M&L preparation and three coat of white wash on newly plastered surfaces of ceiling complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
S&F galvanised steel water tubes medium grade with all fittings and fixed to walls and ceilings or laid in floors of 15 mm dia of bore complete all as specified and directed.
S&F galvanised iron water tubes medium grade with all fittings and fixed to walls and ceilings or laid in floors of 20 mm dia of bore complete all as specified and directed.
S&F PVC valveless syphonic action type flushing cistern low level white with inlet ball valve, float end handle handle including bracket complete of capacity 10 litres complete all as specified and directed.
S&F15mm,CP angle cock fancy type chromium plated, cast copper alloy, with capston heads, screwed down high pressure, with or without lettered 'hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F15mm ,bib tap , fancy type chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'hot' or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F pillar taps long body cast copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for 15 mm dia iron pipe complete all as specified and directed.
S&F Soap dish of PVC fixed with PVC rawal plugs and screw complete all as specified and directed.
S &F Tublar towel rail 20mm dia D type 60 cm long between flange Brass CP complete all as specified and directed.
S & F 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with threaded closed top) hoisted and fixed in position complete all as specified and directed.
S&F ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of loose 20 mm (minimum weight 210 grams) complete all as specified and directed.
S&F gate valve cast copper alloy 20 mm bore, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions complete all as specified and directed.
S&F vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap including connection to trap and cistern and flush pipe (excl flushing cistern ) and making good to disturbed surface of floor complete all as specified and directed.
S&F Vitreous China wash hand basin Counter type (Make- Cera Cat No - S2030119, Snow White), CP waste coupling and 32 mm PVC flexible waste pipe 800mm long etc complete all as specified and directed.
M&L for 20mm thick granite stone slab (of any type) as in floor or skirting for counter & pillar over 20 mm thick screed bed in CM 1:4,machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
S&F 15mm dia PVC connection with PTMT nuts of length 450 mm complete all as specified and directed.
S&F 5 to 6 mm thick bevelled edge looking mirror of required size & shape of best quality with 50 X 20 mm teak wood polished beading with 6 mm thick ply/AC/PVC board beading fixed with C.P screw etc complete all as specified and directed.
S&F PVC (SWR) Pipe of 110mm dia any length and joint fixed on wall, floor or trenches complete all as specified and directed.
S&F PVC (SWR) Pipe of 75mm dia any length and joint fixed on wall, floor or trenches complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes bends any radius with acces door complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes bends any radius with acces door complete all as specified and directed.
S&F 110mm dia PVC (SWR)pipes junction, single (single T/Y ) equal or unequal any radius with acces door complete all as specified and directed.
S&F 110mm dia PVC(SWR) vent cowl complete all as specified and directed.
M & L 75 mm dia of out let PVC (SWR) floor trap plain with grating incl. jointing with solvent cement complete all as specified and directed.
M & L PVC (SWR) gully trap 125 /100 plain with grating incl. jointing with solvent cement with grating complete all as specified and directed.
M&L 10mm thick rendering with CM (1:4) over roof surface even and smooth mixed with WPC complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M & L for Provn of polymeric water proofing roof treatment to non assessable RCC roof described as under and all as specified :- (a) Preparing RCC roof surface and applying one coat of bitumen primer @ Rs. 0.30 Kg /Sqm (b) Applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm. (c) Laying of water proofing teratment with APP modified polymeric of weight not less than 3 kg / sqm water proofing membrane with non woven polyster mat of weight 160gms/sqm as centre core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s all as specified. (d) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane (e) Applying aluminium paint in two coat @ 100 gm/sqm in each coat on finished membrane surfaces complete all as specified and directed at site .
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) and incl CP 32 dia waste coupling complete all as specified and directed.
S&F Urinal spreader of CP brass for fixing with 15 mm dia of pipe complete all as specified and directed.
S&F low density polyethylene (LDPE) pipes 32 mm of pressure rating 6kgf/sq cm complete all as specified and directed.
Excavation in trenches exc 1.5m wide and exc 1.5m up to 3 mtr in depth as in foundation etc as in soft/loose of soil complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 including flush pointing external faces with the same mortar as the work proceeds complete all as specified and directed.
M&L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in 1:4 Cement and sand mortar complete all as specified and directed.
Supply only broken brick bats sub class B bricks and filled in soak pits complete all as specified and directed.
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings, kerbs, benching and the like, including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in PCC (1:3:6) type C-2 for 150 mm dia of pipe complete all as specified and directed.
M&L 150 mm SGSW drain pipe laid in trenches and jointed complete all as specified and directed.
M&L precast RCC as in cover slab including all form work mould etc using Type B1 (1:2:4) with 20mm graded stone agg and set in CM (1:6) complete all as specified and directed.
M&L MS/TMT Bar 6mm to 8mm dia cut to length bent to shape including cranking cutting bending and binding with 0.9mm dia MS annealed wire complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering and rolled/rammed to a true surface complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment , gusset plates, riveting etc, n.exc 10 kg each brackets, conforming to Fe 290 Gd 165 complete all as specified and directed.
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops shape complete all as specified and directed.
M&L Cement concrete 40 mm thick type B-1, 1:2:4 (20mm graded aggregate) Stone Aggregate as in floor finish using extra cement etc complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass-concrete etc complete all as specified and directed.
M&L Cement concrete 75 mm thick type B-1, 1:2:4 (20mm graded aggregate) Stone Aggregate as in floor finished even and smooth without using extra cement, etc but laying in alternet panel and joints filled with 1:3 ratio (bitumen and sand) complete all as specified & directed.
M & L for preparation of newly iron/ steel surfaces of any description with two coats of bituminous Paint etc complete all as specified & directed.
Demolition of Textile covering including frames (if any) and cover fillets (measured flat not girthed) etc complete all as specified & directed.
S&F 605x605mm snap grid of powder coated galvanized iron of angle of size 23mm x 23mm of 30 gauge (Perimeter), T section of size 23mm x35mm main and 23mm x 27 mm (intermediate) of 30 gauge suitable for false ceiling including GI wire 2 mm thick @ 1200 mm centre to centre both ways for hanging arrangement complete all as specified and directed.
M&L for 4mm thick non asbestos fiber cement building board as in ceiling of size 600 x 600mm fixed to GI snap grid frame work complete all as specified & directed.
M&L for two coats of OBD over a coat of primer on new non asbestos fiber cement building boards including preparation complete all as specified and directed.
M & L for Excavation in post holes (or similar holes) in soft/loose soil each not exc. 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc. 25cm in soft/loose soil and getting out complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface of broken bricks aggregates, complete all as specified and directed.
Rolling of soling of broken boulders or quarried stone not exc 15 cm thickness with power roller exc 8 tonne n. exc 12 tonne complete all as specified and directed.
M&L PCC 75 mm thick 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in floor with mixing of Ironite or other wear proof topping, laid in alternate bay incl necessary form work, finishing surface even and smooth without using extra cement complete all as specified and directed.
M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for steel work as in tubular truss incl special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 gde st-240, including gusset plate pole etc complete all as specified and directed.
Supply & Fix of purpose made screw bolts with hexagonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut 16-20 mm dia and exc. 15 cm and n.exc 20 cm long complete all as specified and as directed.
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed.
M & L 15mm thick cement plaster on fair faces of brick work or concrete surface on wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for three coats of white wash on newly plastered surfaces of wall including preparation of surface complete all as specified and directed.
M & L for sand Cushion for filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for PCC type B-1, 1:2:4 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, in filling of angle post ,parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillar/wall etc complete all as specified and directed.
S&F Framed work as in ornamental steel gate revolving on bearing plate incl pintel hinges fixed on pillar with PCC block of size required at site as per sample approved by Engr-in charge. Note:-Weight of gate decided by BOO which will be conveyed by GE before fixing and necessary arrangements for weighing of steel gate by the contractor on his own expense complete all as specified and directed.
M&L for providing, PCC 1:3:6 type C-1 (using 20mm graded aggregate) for embedding angle/sheet including necessary form work etc complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
S&F aluminium partition of specified aluminium section of wt not less than 0.55 Kg/RM including aluminium beads rubber gasket and 5mm thick plain glass in complete portion complete all as specified and directed.
S&F aluminium partition of specified aluminium section of wt not less than 0.55 Kg/RM including aluminium beads rubber gasket and 12mm thick plain toughened glass in complete all as specified and directed.
S&F aluminium door including aluminum beading and rubber gasket for smooth functioning of door (incl sheet glass 5 mm thick, hydrolic door closer,200 mm tower bolt, 200 mm handle both side ) complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of average 2mm thick Birla putty on new plastered surfaces after preparation complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of average 2mm thick Birla putty on Old plastered surfaces after preparation complete all as specified and directed.
M&L for Point wiring complete for One light point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, MS sunken boxes incl modular duly painted with one coat of red oxide and one coat of black paint not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
All as per item No 116.00 here in before but for one 3 Pin 5 Amp switch Socket outlet point on Same board with other switches complete all as specified and directed.
All as per item No 116.00 here in before but for one 3 Pin 5 Amp switch Socket outlet point on an independent board complete all as specified and directed.
All as per item No 116.00 here in before but with cable size FRLSH cable 4 Sq mm for one AC socket out let/ 15 Amps and multistrand insulated copper earth continuity conductor of size FRLSH cable 4 sqmm complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed.
Supply and fix ceiling rose , 3 phase/PVC/polycarbonate, isolated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Supply and fixing Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed.
Supply and fixing socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply and fixing lamp holder/angle holder insulated body with black/white plate for batten fittings incl 7 watt LED Bulb complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix heavy duty exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep (Copper winding) with, four blades, and frame and louvers, complete all as specified and directed.
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 4 way ISI marked, complete all as specified and directed.
Supply and fixing MCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all en-closed in standard steel sheet flush mounting type factory fabricated, powder coated complete without MCB and with enclosure blank plates for unused way suitable for 8 way ISI marked, including taking down old unsv MCB DB and MCBs complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB SPN 40-63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level, connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering, GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 16 sq mm 2 core in trench/floor/on pole/wall, complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable complete all as specified and directed.
Supply and lay GI tube medium grade 25mm size as in cable protection pipe including all fittings complete all as specified and directed.
Supply and fix Air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and directed.
Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and directed.
Supply & fix aluminium strip 25 x 3.15 mm buried in ground complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
M&L for Cross arms, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and directed.
M&L for Pre-cast cement concrete block masonary with solid blocks exc 10 cm in width and setting in mortor complete type B-1, 1:2:4 (20 mm graded aggregated) for fixing GI pipe for air termination rods) complete all as specified and directed
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanised iron strip 32x6mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 40 mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering, GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply, errection, installation, testing and commissioning of raising and lowering type High mast system, 16 Metre height erected in true vertical position. Mast shaft shall be in two/three sections, hot dip galvanised and suitable for wind velocity at site Agra Cantt as per IS 875 Part - III, including accessories for high mast such as head frame, SS wire rope (Grade A1S1 316), double drum winch, Electric Motor, 3 phase to lower & raise the carriage, galvanised lantern carriage arrangement suitable for 8 lumanaries including 08 Nos of Flood light of 100 watt of IP 65, integral flood light with symmetric beam reflector complete, outdoor type electrical control panel with Manual auto on/off timer arrangements suitable for the high mast system. Hot dip galvanised flange mounted type polygonal tapered type high mast of 16 Metre nominal mounting height in two/three piece construction without and circumferential weld complete with 3 - point suspension system, Manual operating handle, Compensating disc, L-stopper - 03 Nos, Mounting plates head frame canopy, Lighting arrestor, stainless steel wire rope to carry six numbers luminaries and control gear boxes, mounting bracket and accessories. The mast shall have an integral power tool installed inside the base compartment for its operation, Design and casting of suitable foundation with M-15 concrete for the high mast considering the safe soil bearing capacity at site, Twin dome aviation obstruction light complete with lamp, providing PVC insulated trailing round cable of 1100 Volt grade multi stranded copper conductor of size 5 core x 4 sqmm of standard required length etc complete all as specified and directed. Note: (i) The technical specification and drawing of High mast pole/foundation submitted to Engr-In-Charge for approval before placing order. (ii) Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour.
Supply and fixing LED Solar Street light fitting 36 Watt smart integrated Smart Bright, All in one Solar Street Light with Infra Red Remote 24 Watt with built in mono crystalline panel, Lithium ferro phospate (Lite PO 4) Battery , MPPT charge controller and PIR sensor with colour teperature 6000-6500 K complete all as specified and directed.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including GI bracket of size 32mm with clamps not less than 1 mtr complete all as specified and directed.
Supply and fix street light timer switch with voltage mounting device enclcosed in SMC Enclosure for automatic and manual switching of street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shell be housed in enclosure complete made out of anti rust/ shock proof/ termite proof/ confirming to IP 54 suitable for 5-8 KW (40 Amp) load compete all as specified and directed Make of switch: Timer Nature switch model No Swadeep-02EC-k5w1P-VMS/ or equivalent of Legrand.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 25 sq mm 4 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply and lay HDPE pipe medium class, ISI Marked double wall corrugated as in cable protection pipe of outer dia 40mm including all fittings complete all as specified and directed.
Supply and lay of GI tube medium grade 50mm size for solar street light including all fittings, including PCC work 1:3:6 complete all as specified and directed.
Supply and fix, New generation, IP 65 LED post-top lantern 40 W, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. 230 watt volts, AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, Clear Cover offers bright illumination for different applications including grouting of 40 mm GI pipe light grade in pillars and lights should be covered with GI net for protection of gate light complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor ISI marked confirming to IS 7098 Part-I of size 6 sq mm 2 core in trench/floor/on pole/wall, complete all as specified and directed.
Supply and lay HDPE pipe double wall medium class, ISI Marked corrugated as in cable protection pipe of outer dia 50 mm including all fittings complete all as specified and directed.
Submain wiring with two single core FRLSH 10 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including FRLSH 10 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connec-tion to earth dolly complete all as specified and directed. Note:- Two single core FRLSH 10 sqmm copper conductor, one run PVC conduit and one run of FRLSH 10 sqmm earth wire shall be considered & measured as one unit.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor 4 Sqmm 2 Core, served with inner sheathing of PVC tape and overall PVC sheathed for connection of flood lights, one twin core cable flat or circular, complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity. Complete all as specified and directed.
S&F of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volts complete all as directed and directed.
M&L for sub main wiring with three runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4 Sqmm drawn in and including PVC rigid conduit medium grade not less than 20mm dia with its accessories, concealed type and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Note :- (i) Finished sub main wiring with three runs of 4 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles complete all as directed and directed.
VISHESH BUILDERS
Balaji Associates
R K SINGH AND CO
m/s Agra Builder
GIRENDRA SINGH AND CO
3Krishna Enterprises
SahaDevSingh Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .