Civil , Electrical and Air conditioning works
NSL/CEO/CBI/NIT/2026/901
NSL/CEO/CBI/NIT/2026/901
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹2,950
₹49,906
30 May 2026
30 May 2026
8 Jun 2026
8 Jun 2026
ESTIMATE FOR CREATION OF OS CABIN AT 7th FLOOR, CBI HQ BUILDING, NEW DELHI
Civil DSR 2023 /
GYPSUM BOARD PARTITION: Providing and fixing partition upto ceiling height consisting of G.I.
frame and required board, including providing and fixing of frame work made of special section
power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive),
consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm
thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener
of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs
and the studs 48mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm
thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610
mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of
partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at
spacing of 450mm centre to centre, and fixing of boards to both side of frame work by 25mm
long dry wall screws on studs, floor and ceiling channels at the spacing of 300mm centre to
centre. The boards are to be fixed to the frame work with joints staggered to avoid through
cracks, M.S. fixing channel of 99mm width (0.9mm thick having two flanges of 9.5mm each) to be
provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head
screws, including jointing and finishing to a flush finish with recommended jointing compound,
jointing tape, angle beads at corners (25mmx25mmx0.5mm), joint finisher and two coats of primer
suitable for board as per manufacturer's specification and direction of engineer in charge all
75mm overall thickness partition with 12.5mm thick double skin fire rated Glass Reinforced
Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)
Providing and fixing thermal unsulation with Resin Bonded rock wool confarming to IS:8183 having
density 48kg/m3050 thick wrapped in 200 G Vergin Polythene Bags fixed to wall with screw, rawel
plug & washers and held and in position by criss casssing GI wire etc. complete as per direction of
Engineer-in-charge.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile
Organic Compound) content less than 50 grams/ litre of approved
brand and manufacture, including applying additional coats wherever required to achieve even
shade and colour
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture,
4 21.18 including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and Sqm 35 5325.90 186406.5
making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
(Door handle, lock and stopper etc.to be paid separately).
Electrical Work
Supplying and fixing following modular switch/ socket on the existing modular plate &
5 1.24 switch box including connections but excluding modular plate etc. as required.
Digitally signed by AMIT
Supplying and fixing modular blanking plate on the existing modular plate & switch box
Supplying and fixing following size/module, GI box along with Modular base & cover plate on
existing modular metal boxes etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
9 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual
2.15 current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB
complete with connections, testing and commissioning etc. as required.
1.53 supply and drawing of UTP 4 pair CAT.6 LAN Cable in the existing surface/recessed steel/PVC
10 conduit as required.
INSULATED CHILLED WATER PIPING (resin bonded fiber glass glass INSULATION) 30.1 Supplying, laying/ fixing, testing and
commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and
1 30.1 fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cum
density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour
barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as
amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required.
Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589,
from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
2 30.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly
insulated to the same specifications as the connected piping and adequately supported as per specifications
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified
Digitally signed by AMIT
30.19 Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at
regular interval as per site requirement etc. complete as required as per specifications.
18.14.8 Cable/Wiring
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
4 1.14 copper conductor, single core cable in surface/ recessed
medium class PVC conduit as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on
surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,
5 2.3 powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive
6 2.1 load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles
of Size 595x595 mm o fapproved texture, design and patterns having moisture content less than 2%,
humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part
4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-
locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per
sqmincluding both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of
size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm
to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items
(galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia
fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm.
Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery
wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood
screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-
With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.
Digitally signed by AMIT
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special
sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of
27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm
dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of
required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section
0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450
mm centre to centre, hall be fixed in a direction perpendicular to G.I. intermediate channel with connecting
clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter
8 12.45 channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed
to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm
interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and
square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for
board, all as per manufacturer's specification and
also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete as
Supply, installation, testing and commissioning of Chilled Water Ceiling Suspended Hydronic Cassette type fan coil
unit, four(4) way directional flow, low noise, each complete with two(2) rows of deep chilled water cooling coil,
multi-blade centrifugal fan, test reports from National Accreditation Board for Testing and Calibration Laboratories
(NABL)/AHRI accredited lab, electronic air cleaning system, required set of ball valves with & without strainers & 2
9 MR way Motorized valve, insulated condensate drain pans with drain pump assembly & drain pump failure alarm, pipe
connections through copper pipes, Infra-red remote control, Liquid Crystal Display (LCD), four (4) speed motor , fan
four(4) direction air flow, auto swing louver, decorative panel etc., condensation drain connections, All units shall be
suitable for 220 +/- 10% Volts, 50 Hz, single phase power supply etc. complete as per specification. The wireless
Remote temperature control / thermostat shall have memory back up for set point re-store in case of power failure
and re-start. Four(4)hanger rods with required anchoring fasteners, hooks, washers etc.complete as per CPWD
specification and as directed by Engineer-in charge.
10 MR Drain Piping
Supply,installation,testing and commissioning of PVC drain water with necessary clamps, fittings such as
bends tees etc. and duly insulated.
Digitally signed by AMIT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT CBI cabin.pdf
Tender Document
BoQ.pdf
Tender Document
SCC CBI Cabin.pdf
Tender Document
GCC 2026.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
updated forms.pdf
Tender Document
Makelist.pdf
Tender Document
Technical circular upto 33 amendment.pdf
Tender Document
7th Floor Cabin Drawing.pdf
Tender Document
Download all tender documents and submit your bid