| 1 | L-1₹43.7 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹48.7 L+₹3.8 L (8.46%)Rejected-Finance 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹49.1 L+₹4.2 L (9.35%)Rejected-Finance AVAS VIKAS NANDANPURA JHANSI UP 284003 | JHANSI | UTTAR PRADESH | 284003 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L-4₹49.6 L+₹4.7 L (10.4%)Rejected-Finance | L-4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L-5₹50.0 L+₹5.1 L (11.3%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | L-5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹87 L
EMD Value
₹94,000
Closing Date
26 Jun 2024, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR TO INTERNAL WIRING, LIGHT FITTINGS, MCB/ DB, FANS, STREET LIGHTS AND OTHER ALLIED WORKS
2024_MES_659681_1
8807/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Rangia and Changsari
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹94,000
Yes
31 Aug 2024
13 Jun 2024
28 Jun 2024
13 Jun 2024
26 Jun 2024
21 Jun 2024
13 Jun 2024 - 17 Jun 2024
Amount
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl consealed (on wall only) PVC conduit (medium grade) with fittings of adequate dia and length with all accessories and fittings like bends, elbow, crosses, etc. with modular terminal boxes for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred), complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 01 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 01 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 01 here-in-above, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred), complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 05 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 05 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 05 here-in-above, but for One 3/5 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Switch, One Module, 1-Way, 6 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of Modular Switch, One Module, 1-Way, 16 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of Modular Socket, 3 Pin, combined, Three Module, 6 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of Modular Socket, 2/3 Pin, combined, Three Module, 16 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of modular cover plate (white) with frame, 3-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 4-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 6-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 8-module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular cover plate (white) with frame, 12-module, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Modular Switch, One Module, 1-Way, 6 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular Switch, One Module, 1-Way, 16 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular Socket, 3 Pin, combined, Three Module, 6 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F in-repair of Modular Socket, 2/3 Pin, combined, Three Module, 16 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Socket outlet 3/5 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Bell push, flush type, 5/6 amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Switch socket combination 2 in 1, 3/5 pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Bell push, flush type, 5/6 amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of pop-up power point socket suitable for 220-240V, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of fan capacitor of 2.5 mfd, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured as length of PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 4.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 4.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured as length of PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F in-repair of Vertical TPN DB with MCCB Incomer, 12 way outgoing with 100Amp rated bus-bar, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, IK 09, With provision for 3 pole and 4 Pole MCCB as incomer and SP/TP MCBs as outgoings complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Single pole (SP) enclosure with a three pin earth plug and socket complete with one 20Amps single pole (SP) MCB suitable for 240V, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of modular type DB box for AC connection including 20A MCB SP protected three way with socket and cover plate, suitable for 240V, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 2 way 240 volt, with rated Bus-bar, Single door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 40-63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Driver unit suitable for 36watt LED recessed light (600x600mm), including making necessary connection as per existing, complete all as specified and as directed by engineer-in-charge.
S&F in-repair of LED strip light (warm white), AC, IP-65 rated, 6W/ mtr, 220-240V, 50Hz, alongwith connector, power plug, bridge rectifier and all connected items, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative regal type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of destello recessed LED light fitting 36W with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type (1133x67x40mm) with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 12W Elegantly designed sleek surface mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver, Ac 220-240V, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of decorative wall light (indoor) with brushed nickel/ bronze finish with opal glass diffuser suitable for 9Watt LED lamp, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 10 watt capacity, B-22 base LED Bulb/ lamp (Warm white/ Cool White), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge. (NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately)
S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant (IK-08) including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge. (NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately)
All as per Item No. 60 here-in-above, but for 60 Watt LED street light, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 Flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 70 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant (IK-08) including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge. (NOTE- the cost of G.I. pipe bracket, bracket mounting clamp, bolts and nuts shall be paid separately)
All as per Item No. 62 here-in-above, but for 120 Watt LED flood light, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete with fixing accessories, complete as all specified and as directed by Engineer-in-charge.
S&F in-repair of IP-65 rated robust designed 8Watt LED bollard garden Light Fitting with black ABS Plastic Spigot, Spun Aluminium Canopy with Diffuser duly pre-wired, including embedding on 150x150x200mm PCC Block 1:3:6 (20mm Graded Aggregate), complete as all specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire.
M&L for disconnecting and taking down exhaust fan/ table fan/ wall fan/ pedestal fan of any sweep, sealing cable end, dismantling blades and removing fan and blades to store for Opening Stator, Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, re-winding the coil and Re-assembling the fan after proper repair and applying two coats of synthetic enamel paint over a coat of red oxide primer by spraying including filling cavities with filler, after cleaning all dust and necessary surface preparation including fixing the fan in original position and connecting up including provision of cable from ceiling rose or connector to fan (as/if required), complete all as specified and as directed by Engineer-in-charge. NOTE:- Spare-parts and cost of re-winding shall be measured and paid separately under relevent item.
M&L for re-winding the coil of exhaust fan/ table fan/ wall fan/ pedestal fan of any sweep with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, complete all as specified and as directed by Engineer-in-charge.
Supply only Ball Bearing (as approved) suitable for Exhaust Fans of upto 450 mm swipe, complete all as specified and as directed by Engineer-in-charge. MAKE- SKF/ NBC/ TATA
Supply only Capacitor 4.0 mfd (as approved) 230 Volts, AC, 50 Hz, suitable for Exhaust Fan of any Sweep and Make, complete all as specified and as directed by Engineer-in-charge.
M&L for disconnecting and taking down ceiling fan of 1200/1400 mm sweep, sealing cable end, dismantling blades and removing fan and blades to store for Opening Stator, Cleaning of Parts, replacement of Unserviceable Parts as ordered, Greasing of Moveable Parts, re-winding the coil and Re-assembling the ceiling fan after proper repair and applying two coats of synthetic enamel paint over a coat of red oxide primer by spraying including filling cavities with filler, after cleaning all dust and necessary surface preparation including hanging the ceiling fan in original position and connecting up including provision of cable from ceiling rose or connector to fan (as/if required), complete all as specified and as directed by Engineer-in-charge. NOTE:- Spare-parts and cost of re-winding shall be measured and paid separately under relevent item.
M&L for re-winding the coil of ceiling fan 1200/1400 mm sweep with Supper Enameled Copper Wire of same Gauge and same Weight with Insulation Paper, Varnishing and Heating, complete all as specified and as directed by Engineer-in-charge.
Supply only Ball Bearing No. 6201/6202 as approved suitable for Ceiling Fan of 1200mm Sweep, complete all as specified and as directed by Engineer-in-charge. MAKE- SKF/ NBC/ TATA
Supply only Ball Bearing No. 6203/6204 as approved suitable for Ceiling Fan of 1400 mm Sweep, complete all as specified and as directed by Engineer-in-charge. MAKE- SKF/ NBC/ TATA
Supply only Capacitor 2.5 mfd (as approved) 230 Volts, AC, 50Hz, suitable for Ceiling Fan of any Sweep and Make, complete all as specified and as directed by Engineer-in-charge.
Supply only Capacitor 3.15 mfd (as approved) 230 Volts, AC, 50Hz, suitable for Ceiling Fan of any Sweep and Make, complete all as specified and as directed by Engineer-in-charge.
S&f in-repair of split pin for ceiling fan of any sweep, complete all as specified and as directed by Engineer-in-charge.
S&f in-repair of rubber reel for ceiling fan of any sweep, complete all as specified and as directed by Engineer-in-charge.
Labour only for lowering down unserviceable Geyser of 25-50Ltr capacity of any type by disconnecting all Electrical and Water Supply Connections, cleaning internally and externally thoroughly, repairing and brazing Inner Tank for Leak Proof where ever required, testing of leakages with Pressure Test, replacing the unserviceable Parts, re-assembling and installing the Geyser in Original Position and providing all neccesary Connections and Testing, complete all as specified and as directed. NOTE :- (i) Replacement of defective Parts shall be measured and paid under appropiate Items.
S&F in-repair of Thermostat/Thermal cutoff suitable for Water Storage Geyser of range 0-90ºC as required, conforming to IS (Make as approved) complete all as specified and as directed.
S&F in-repair of Electro-plated Heating Element of any shape (as per site requirement & as approved), suitable for Electric Geyser of 1.5/2.0 KW capacity, 240 Volts, complete all as specified and as directed. MAKE : BAJAJ/RECOLD/HAVELLS/USHA
S&F in-repair of Stainless steel braided flexible connection pipe of 450mm long (02 Nos) with brass connector series for both inlet and outlet of Geyser, complete all as specified ans as directed. MAKE:- PRAYAG/POLYTUF/ AS EXISTING
S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6 Sqmm section, complete all as specified and as directed by engineer-in-charge.
All as per Item No. 83 here-in-above, but for cross-sectional area 10 Sqmm, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 83 here-in-above, but for cross-sectional area 16 Sqmm, complete all as specified and as directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 10 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing and taking down the existing old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) light grade GI pipe of 0.6m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 25x4mm) for fixing of building security/ street light fitting as per existing, complete all as specified and as directed by Engineer-in- Charge.
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Fly ash Bricks, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for taking down existing defective Street Light/Gate light/Post top/ Bollard light Fitting of any Watt/Make from pole, repairing the same by opening Cover, re-wiring the Light Fitting with 3.0 core 1.5 Sq mm Copper Conductor Cable, multi-stranded, cleaning and checking unserviceability, refixing Light Fitting in Original Position after repaired, testing and connecting up, complete all as specified and as directed. NOTE:– (i) Cast of nut-bolt-washer/ screws shall deemed to be included in unit quoted rate. (ii) Spare parts like Driver, 3.0 core 1.5 Sq mm Copper Conductor Cable, multi-stranded, etc. wherever required will be measured and paid under appropriate Item(s) as fixed in-repair.
S&F in-repair of Driver unit suitable for 45-60 watt LED street light, including making necessary connection as per existing, complete all as specified and as directed by engineer-in-charge.
S&F in-repair of Driver unit suitable for 25-40 watt LED street light, including making necessary connection as per existing, complete all as specified and as directed by engineer-in-charge.
S&F in-repair of Driver unit suitable for 70-120 watt LED street light/ Flood light, including making necessary connection as per existing, complete all as specified and as directed by engineer-in-charge.
S&F in-repair of Multistandarded Copper Conductor cable of 3 Core 1.5 Sq mm size drawn through steel tubular poles for interconnection of cable looping box to street light Fitting, Post Top Lantern & etc including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Pole Box/Junction Box of size 155 X 210 X 92mm (LxBxH) made out of Polycarbonate material totally enclosed, dust and vermin proof, door pasted with rubber gasket, water tight IP 66/67 protection single leaf shutter in front having proper locking arrangements, mounted on security light pole with suitable clamps (GI Flat iron of 25x3mm), nuts, bolts, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of On load Changeover Switch with sheet metal enclosure and advanced neutral switch, Four Pole (FP), 63 Amps, 415 Volts, conforming to IS/IEC 60947-3 with and including all accessories, connecting up and re-fixing of cables with proper lugs, complete all as specified and as directed by Engineer-in-charge.
ADITI CONSTRUCTION CO.
M/S Hema construction
Purbanchal Construction Co
HEMONTA DAS
SONI ENTERPRISE
M/s Sohini Construction
M/S UTTAM SAHA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .