| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | ₹21.0 L Quoted ₹21.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹23.0 LRejected-AOC | ₹23.0 L | L2 | Rejected-AOC Rejected being non L1 |
| Sl No | Description | Qty | Unit | SRI LAKSHMI GANESH ENGINEERING WORKS L2 | M/S Mist Hills Enterprices L1 |
|---|---|---|---|---|---|
| 1.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc. | 71 | Point | 45 ₹3,195 | 11 ₹781 |
| 2.00Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :- | |||||
| 3.00 | All as per item No. 2 here-in-before but for One light point controlled by one switch complete all as specified and as directed. | 18 | Point | 750 ₹13,500 | 410 ₹7,380 |
| 4.00 | All as per item No. 2 here-in-before but for One fan point controlled by one regulator / switch complete all as specified and as directed. | 15 | Point | 750 ₹11,250 | 390 ₹5,850 |
| 5.00 | All as per item No. 2 here-in-before but for One 3 pin socket outlet 5 amps socket on independent board complete all as specified and as directed. | 12 | Point | 800 ₹9,600 | 420 ₹5,040 |
| 6.00 | All as per item No. 2 here-in-before but for One 3 pin socket outlet 5 amps socket on Same Board complete all as specified and as directed. | 12 | Point | 200 ₹2,400 | 249 ₹2,988 |
| 7.00 | All as per item No. 2 here-in-before but for One light point controlled by two Nos of two way switches complete all as specified and as directed. | 1 | Point | 900 ₹900 | 300 ₹300 |
| 8.00 | All as per item No. 2 here-in-before but for One bell/buzzer point controlled by one push button complete all as specified and as directed. | 1 | Point | 900 ₹900 | 320 ₹320 |
| 9.00 | All description as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and as directed. | 12 | Point | 900 ₹10,800 | 540 ₹6,480 |
| 10.00 | Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed. | 40 | Each | 38 ₹1,520 | 180 ₹7,200 |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
6 Oct 2025, 6:00 pmClosed
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
REPAIR/MAINTENANCE OF SUMMER COOLING APPLIANCES AT PARUNDU AND 7N DET AND INTERNAL ELECTRIIFCATION AT 7N DET UNDER GE TIRUNELVELI
2025_MES_728988_1
GE/TVL/8487/E8 of 2025-26
Open Tender
Electrical and Maintenance Works
270 days
Ramnad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹52,000
Yes
16 Dec 2025
2 Sept 2025
8 Oct 2025
2 Sept 2025
6 Oct 2025
16 Sept 2025
3 Sept 2025 - 11 Sept 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors etc.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :-
All as per item No. 2 here-in-before but for One light point controlled by one switch complete all as specified and as directed.
All as per item No. 2 here-in-before but for One fan point controlled by one regulator / switch complete all as specified and as directed.
All as per item No. 2 here-in-before but for One 3 pin socket outlet 5 amps socket on independent board complete all as specified and as directed.
All as per item No. 2 here-in-before but for One 3 pin socket outlet 5 amps socket on Same Board complete all as specified and as directed.
All as per item No. 2 here-in-before but for One light point controlled by two Nos of two way switches complete all as specified and as directed.
All as per item No. 2 here-in-before but for One bell/buzzer point controlled by one push button complete all as specified and as directed.
All description as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and as directed.
Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed.
S&F in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed.
Supply and fix in replacement switch Socket combination 2 in 1, 5 Amps Flush type 240 Volts complete all as specified and as directed.
Supply and fix in replacement switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 240 Volts complete all as specified and as directed.
Supply and fix in replacement ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
Supply and fix in replacement Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed.
Supply and fix in replacement Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
Supply and fix in replacement Bell push flush type 5 A 240 Volts complete all as specified and as directed.
Supply and fix in replacement Modular switch 1 way 5A, 1 Module complete all as specified and as directed.
Supply and fix in replacement Modular switch 1 way 16A, 1 Module complete all as specified and as directed.
Supply and fix in replacement Modular bell push ,5 A, 1 Module complete all as specified and as directed.
Supply and fix in replacement Modular Socket 5A-2/3 pin combined 2 Module complete all as specified and as directed.
Supply and fix in replacement Modular Socket 5A / 15A - 2 / 3 pin combined 2 Module complete all as specified and directed
Supply and fix in replacement Modular fan regulator step type , 2 Module complete all as specified and as directed.
Supply and fix in replacement 3mm thick laminated sheet top cover on switch boards including cutting, fixing and screwing and making good the disturbed surface of wall complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring with aluminum /copper conductor cable 4/6 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
Material and labour for sub main wiring with two run single core 4 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia/PVC casing capping 20 mm including conduit accessories all as specified and directed. Note: Three runs of 4 Sqmm cable and one run of 20mmconduit / casing capping will be measured as one unit length.
Material and labour for sub main wiring with two run single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length.
Supply and fix in replacement Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) complete all as specified and directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, SPN 4 way DB ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, TPN 4 way DB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB SP 5 A to 32 A , B curve, 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB SPN 32 Amps , C curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB SPN 40 A- 63Amps , C curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB TP 25A - 63 A , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB TPN 16 A- 32 Amps , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCB TPN 40A- 100 A , B curve 10 kA including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in replacement MCCB 4 pole 415 volts , 100 Amps, with rupturing capacity 16 KA complete all as specified and as directed
Supply and fix in replacement LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed Make : Philips
S & F LED light fitting in replacement 1x9W/1X10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fix in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Supply and fix in replacement LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
Supply and fix in replacement round shape/Square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fix in replacement LED light fitting 2x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including all accessories complete all as specified and as directed.
Supply and fix in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
Supply and fix in replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Taking down geyser of any make/ type and any capacity after disconnecting the water and electric line connections from any height, bringing down to floor, dismantling the Geyser and overhauling by means of repair/replacement of the defective spares, cleaning externally and internally re-assembling the geyser, fixing in same position and testing for satisfactory working etc complete. Note: Replacement of defective spares shall be measured and paid under relevant item separately.
Supply only Neon lamp indicator (Green and Red)
Supply only Bottom flange with inlet and outlet pipe (Apparatus plate)
Supply only Thermostat conforming to IS 3017
Supply only Flexible connection pipe set of two for cold and hot water
Supply only Heating element 2.0 KW
Supply Syphon assembly
All as per item No.54 but for exhaust fan 300 mm including replacing of rusted nut and bolts complete all as specified and directed.
All as per item No.54 but for exhaust fan 450 mm including replacing of rusted nut and bolts complete all as specified and directed.
Supply and fix ball bearing suitable for any sweep ceiling fan complete all as specified and directed.
M & L for rewinding with super enameled copper wire including varnishing, drying and connection complete all as specified and directed.
Supply and fix in replacement louvers for exhaust fan of any size including taking down old unserviceable louvers and removing the material for taking credit complete all as specified and directed.
Supply and fix in replacement Condensor 2.5 to 4 mfd for Ceiling / exhaust fan, including taking down old unserviceable material for taking credit complete all as specified and directed.
Providing comprehensive annual maintenance periodical/preventive maintenance including annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specification by providing one AC/Refrigeration mechanic including replacement of components as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil. (b) Cleaning of air filters, indoor unit grills & filters through air blower. (c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period. (d) Check and replace the refrigerant pipe once in a contract period or as and when required. (e) Check and repair the minor electrical fault in incoming supply. (f) Check and replace the water PVC pipe. (g) Replacement of faulty spares/components (h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional (Each Job contains 3 Complaints)
Supply only the following new items for 1.5 / 2.00 Ton Capacity Split type AC including testing and commissioning etc complete all as directed.
Capacitor 36/45/50 MFD.
Air filters.
Outdoor fan motor
Indoor fan motor
Indoor blower
Copper condenser coil unit (for A/C)
Copper cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD.
Outdoor fan motor capacitor 3 to 6 MFD
Non return valve (For gas top up charging)
Remote control suitable for Non inverter model Split AC.
Remote control suitable for inverter model Split AC.
Electronic components for repairs to PCB
PCB board suitable for Non inverter model split AC 1.5/2.0 TR
PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR .
PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR .
Copper pipe of size 1/2" for suction line with foam insulation
Copper pipe of size 1/4" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Supply and fix High pressure and low pressure valves 1/4'' X 1/2'' complete all as specified and as directed.
Supply and fix PVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for AC complete all as specified and as directed.
Supply and fix Metal plug top for AC
Supply only the new following items for 3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed.
Air filters.
Condenser fan motor with blade set .
Blower fan motor with blade set.
Blower with circular leaf.
Condenser coil unit (for A/C)
Cooling coil unit (for A/C)
Indoor motor capacitor 2.5 MFD.
Non return valve (For gas top up charging)
Remote control suitable for Non inverter Tower AC.
PCB board suitable for outdoor unit.
PCB board suitable for indoor unit.
Copper pipe of size 5/8" for suction line with foam insulation
Copper pipe of size 3/8" for discharge line with foam insulation
Swing Motor for indoor unit
Outdoor unit stand
Condenser fan motor blade
Indoor Motor blower
Supply and fix High pressure and low pressure valves 3/8'' X 5/8'' complete all as specified and as directed.
Supply and fix PVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for AC complete all as specified and as directed.
Three phase metal plug top
Supply only the new following items for water cooler 40/80 Litres capacity including testing and commissioning etc complete all as directed.
Relay unit with OLP
PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm.
Thermostat assembly
Water tap suitable for water cooler.
Starting Capacitor 80-100 MFD
Running capacitor 20 MFD
Condenser fan motor 1.6HP with blade set
Supply and fixing compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
Split type AC 1.5 Ton capacity.
Split type AC 2.0 Ton capacity.
Water cooler 40/80 Litres capacity .
Floor standing/Tower AC 3 Ton Capacity.
Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed.
Repair /servicing of stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity
M & L Painting complete with super enamel paint of approved colour for water cooler all as specified and directed.
Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed.
Supply only R22 /R32 /R410 Gas complete all as specified and directed.
Supply only R134a Gas complete all as specified and directed.
Dismantling and disconnecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :- NOTE : The wt of refrigerant used for filling/top up shall be measured and paid under respective item.
Supply only 2 nos of 1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner
Material and labour for making good surface with sealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete.
Material only for following items for refrigerators/Deep Freezers 320 Litres capacity including testing and commissioning etc complete all as directed.
(a) Relay unit.
(b) Thermostat assembly.
(c) Condenser coil
(d) Freezer for double door refrigerator
Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
(a) Refrigerators 310/320 litres capacity.
(b) Deep Freezers 320 litres capacity.
M & L Painting complete with super enamel paint of approved colour for Refrigerator/ water cooler all as specified and directed.
M&L for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SP MCB, complete all as specified and directed by Engr-in charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed by Engineer-in-Charge.
M&L sub main wiring with two single core 1100 V grade conforming to IS 694 PVC insulated unsheathed cables 4 Sq mm FRLSH multi stranded copper conductor drawn through and incl 25 mm dia non metallic PVC rigid conduit and conduit accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sqmm FRLSH copper wire earth continuity conductor etc complete all as specified and directed by Engr-in-Charge. Note : Three runs of 4 sqmm cable with one run of PVC conduit shall be measured as one run.
Supply and Fix in repairs MCB SP 240 V, 6A to 32 Amps 10KA, 50Hz 'C' curve 10KA, 50Hz 'C' curve complete all as specified and directed.