Chief Engineer (ESG)
DCSEM, 3rd Floor, V.S. Bhavan, Anushaktinagar, Mumbai - 400094.
Replacement of old air conditioners in BARC CHSS dispensaries at various locations in city area of Mumbai.
2023_DCSEM_750629_1
DCSEM/CQD/QSC/ Disp-AC-Replace/NIT/08 dt 26.04.23
Open Tender
Job Works
Works
180 days
City Area
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹83,000
7 Jul 2023
27 Apr 2023
19 May 2023
27 Apr 2023
17 May 2023
27 Apr 2023
27 Apr 2023 - 10 May 2023
Amount
Inverter split type Air conditioners: Supply, installation, testing & commissioning of Inverter wall mounted all- weather split type air conditioners of following capacities confirming to IS: 1391 (PART-2) or it`s latest amendments, suitable for 230V, 50 Hz, single phase A/C supply having auto humidity control, on/off timer with advance start up, auto climate technology, high capacity compressor, highest BEE star rating (i.e 5 star), pressure testing & flushing with nitrogen, leak testing for entire system, vaccumising using vacuum pump, R410a/R32 gas charging as per installation manual, for smooth operation of AC`s etc complete all as per the instructions & to the entire satisfaction of EIC.
1.5 TR Inverter hi-wall split type air conditioner along with following specifications: 1. Cooling capacity - minimum 5.1kW , 2. Energy efficient rating- minimum 3.52
1.8 TR Inverter hi-wall split type air conditioners along with following specifications: 1. Cooling capacity - minimum 6.2kW , 2. Energy Efficient Rating- minimum 3.61.
Refrigerant piping with insulation: Supply, installation, testing & commissioning of Refrigerant copper piping with 10 mm rubber nitrile insulation as per site situation with necessary structural clamps/ supports/ bends/ elbows/ reducers/U-bends/ flare nuts/ adapters/any other brass fittings as required etc. wrapped with monsoon tape all as per AC`s manufacturer's standards.
Drain piping: Supply, installation & commissioning of PVC drain piping(flexible/hard) of suitable size upto 25 mm diameter duly insulated with heatlone sheet, etc. complete all as per the site condition & instructed by EIC.
Control cabling: Supply, installation & commissioning of Control cabling with adequate size of copper conductor wire/ power cable to connect outdoor units with respective indoor units & power cable to connect power outlet to ODU/IDU complete with lug connections etc. complete all as per site situation as required & instructed by the Engineer –in – charge.
4 core x 2.5 sq.mm cable
3 core x 2.5 sq.mm cable
M.S. Stands: Fabrication, supply & installation of M.S stand for the ODU of split A/C unit as required & fabricated with suitable opening mechanism for maintenance purpose of ODU unit, painting with one coat of red oxide primer & two coats of enamel paints of approved make & shade to all M.S parts at all levels & elevations as required and desired by EIC.
Casing & capping: Supply & laying of casing/capping (PVC trunking 100 mm x 50 mm) for enclosing refrigerant tubing with insulation, drain line and electrical cable as per site condition, specifications and as instructed by E.I.C.
Window type Air conditioners: Supply, installation, testing & commissioning of 1.5 Ton window mounted all- weather A/C units similar to Model no AXGB18BAWA of M/s OGeneral confirming to IS: 1391 (PART-2) or it`s latest amendments, suitable for 230V, 50 Hz, single phase A/C supply having auto humidity control, on/off timer with advance start up, auto climate technology, high capacity compressor, highest BEE star rating (i.e 5 star), pressure testing, leak testing for entire system, vaccumising using vacuum pump, R410a/R32 gas charging as per installation manual, for smooth operation of AC`s etc complete all as per the instructions & to the entire satisfaction of EIC. Scope of work include required modification in existing window frame for installation of Window AC.
Dismantling and safe removal of Air conditioners: Dismantling and safe removing the old existing wall/Window mounted air conditioner including pumpdown of refrigerant in the system,safely removal its copper piping & M.S. stand and packing of existing piping holes etc. depositing the dismantled AC unit at DCSEM store Anushaktinagar, Mumbai complete with all as per requirement and instructed by EIC.
M/s Associated Engineers
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .