EE II CKHED
P 12 CIT Road 1st floor KOLKATA 700014
Renovation and modification of HDU ICCU Pre Operative CTVS Wards and Doctors Rooms, under the Department of CTVS at 4th floor of UNB Building within NRS campus EI Works and Airconditioning System SITC of Air Conditioning System
2021_WBPWD_330672_1
WBPWD/EE-II/CKHED/NIT-15/20-21 3rd call
Open Tender
A/C ORG
Item Rate
180 days
NRSMCH
as per NIT
4 documents required · 4 mandatory
₹70,000
P 12 CIT Road 1st floor KOLKATA 700014
24 Nov 2021
5 May 2021
23 Jun 2021
5 May 2021
21 Jun 2021
13 May 2021
11 May 2021
Amount
Supply & Delivery of 8.5 TR Capacity Single Circuit Air cooled Ductable Split Unit with Rated Cooling Capacity of 102000 BTU/Hr, single scroll compressor, refrigerant R-410A, Room Discharge CFM 3400 , and suitable for operation on For ODU: 415 Volt, 50Hz, 3 PH & For IDU: 230 Volt, 50Hz, 1 PH AC supply. (Make: Hitachi / Ogeneral / Daikin)
Supply & Delivery of 5.5 TR Capacity Single Circuit Air cooled Ductable Split Unit with Rated Cooling Capacity of 66000 BTU/Hr, single rotary compressor, refrigerant R-410A, Room discharge CFM 2000 and suitable for operation on For ODU: 415 Volt, 50Hz, 3 PH & For IDU: 230 Volt, 50Hz, 1 PH AC supply. (Make: Hitachi / Ogeneral / Daikin)
Installation testing & Commissioning Charges for 8.5 TR Ductable Split Air Conditioner (Both Indoor & Outdoor Unit) incl. nitrogen flashing , Leak testing & vaccuming, Gas Charging as per disrection E.I.C. .
Installation testing & Commissioning Charges for 5.5 TR Ductable Split Air Conditioner (Both Indoor & Outdoor Unit) incl. nitrogen flashing , Leak testing & vaccuming, Gas Charging as per direction E.I.C. .
Supply, Installation testing & Commissioning of Copper Refrigeration pipe line for Liquid Line (5/8" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 8.5 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Suction Line (1-1/8" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 8.5 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Liquid Line (1/2" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 5.5 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply, Installation & Commissioning of Copper Refrigeration pipe line for Suction Line (7/8" OD with 0.6 mm thick) with supports & brackets (make: Ryoku/Rajko/Nippon) incl. 9 mm thick Nitrile rubber insulation with Proper taping (make: Accroflex/Armacell/Suprime) for 5.5 TR Ductable Split Air Conditioner as per direction E.I.C.
Supply & Fabrication of sheet metal supply Ducting & Plenum Chamber complete with Support , Hanger etc. of the following as per Direction of E.I.C
Supply & Fixing of 19 mm thick Nitrile Rubber Aluminium Foil Face Thermal Insulation on duct complete with all accessories as required as per Direction of E.I.C . (Make: Armacell/ K-Flex / A- Flex)
Supply & Fixing of 19 mm thick open cell Nitrile Rubber Acoustic Insulation Under duct complete with all accessories as required as per Direction of E.I.C . (Make: Armacell/ K-Flex / A- Flex)
Supply & Fixing of Fire retadrant nonporus double layer Flexible Connection ( CANVAS ) between each Indoor Unit & Duct as per Direction of E.I.C .
Supply & Fixing of 22 SWG GI Aerofoil blades type Non Return Damper complete with Linkages, Levers, Fitting, Support Accessories ,any other item required to make the system complete as per Direction of E.I.C
Supply, Fixing, Testing ,Commissioning of fresh air arrangement with Volume Control Damper , Birds Screen etc complete as required
Supply, Fixing, Testing ,Commissioning of Al Powder Coated Supply Grill with VCD ,
Supply, Fixing, Testing ,Commissioning of Al Powder Coated Supply Grill without VCD
Supply, Installation & Commissioning of 25 mm PVC Drain Pipe Line (25 mm OD, HD 1 mm Thick) with Insulation , Support & Bracket, For 8.5 & 5.0 TR Ductable Split Unit as per Direction of E.I.C
4 CORE X 2.5 Sq mm Cu Armoured Cable for ODU to IDU of 8.5/5.5 Tr Ductable Split Unit as per Direction of E.I.C. (Make: Gloster / Havells/ Ploycab/ Finolex)
Supply & Fabrication of Trap Door & making arrangement for Servicing the Units, for both 8.5/5.5 TR ducable concealed split AC as per Direction of E.I.C
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 2 nos. 8.5/5.5 TR ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 6Mtr. x 1.2Mtr., as per Direction of E.I.C
Charges of Civil Works like Wall cutting , finishing, foundation for installation incl. all related civil works for completion of work in all respect as per Direction of E.I.C
Scaffolding for fixing of Outdoor Unit to a suitable height to avoid theft for both 8.5/5.5 TR ducable as per Direction of E.I.C
Suply , Fiting & Fixing in position suspended boxing for return/Supply air arrangement for ducting incl. false ceiling for boxing of AHU unit with frame work of alluminium hollow section of size 50mm X 25 mm (2.0 mm thickness) combined with aluminium corners of size 38 mm X 25 mm X , Suspended by alluminium hollow tube section of size 38 mm X 25 mm, 25mm X 25mm powder coated with alluminium composite panel of thickness 3.0 mm comprising of protective film , polyester coating primer, alluminium coil , sdhesive film , polyethelene core again with one layer adhesive film , alluminium bottom coating and finally service coating as per manufacturer's specification finished with alluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of E.I.C
Supply 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. rotary compressor, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Ogeneral/Daikin)
Supply 5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr. with 2 Nos. rotary compressor, refrigerant R-410A, 2 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Ogeneral/Diakin)
Supply 3TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2 Nos. rotary compressor, refrigerant R-410A, 2 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM. ( Make: Hitachi/Ogeneral/Diakin)
Supply 2TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 Nos. rotary compressor, refrigerant R-410A, 1 nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM. ( Make: Hitachi/Ogeneral/Diakin)
Installation, testing and Commissioning Charges incl. refrigerant R-410A for 7.5 TR concealed type Split Air Conditioner
Installation, testing and Commissioning Charges incl. refrigerant R-410A for 5 TR concealed type Split Air Conditioner
Installation, testing and Commissioning Charges incl. refrigerant R-410A for 3 TR concealed type Split Air Conditioner
Installation, testing and Commissioning Charges incl. refrigerant R-410A for 2 TR concealed type Split Air Conditioner
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku/Totaline/Jobu)
a) Liquid Line (1/4" OD with 0.6 mm thick)
b) Liquid Line (3/8" OD with 0.6 mm thick)
c) Suction Line (5/8" OD with 0.7mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
a) Liquid Line (1/4" OD with 0.6 mm thick)
b) Liquid Line (3/8" OD with 0.6 mm thick)
c) Suction Line (5/8" OD with 0.7mm thick)
Supply and laying Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex)
a) 4 core 2.5 sq.mm communication cable
Supply and fixing flexible canvass connection for concealed split air-conditioners.
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 7.5/5.0 TR Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1.2Mtr. Structural design should be approved by E.I.C.
Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mm x 6mm) for making platform for installation of outdoor unit of 3.0/2.0 TR Concealed split AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be fabaricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC Structural design should be approved by E.I.C.
Supply and fixing of Al powder coated continuous Grill (Make- Premier)
S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
a) 25 mm dia
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner incl. false ceiling for boxing of AHU unit with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated with aluminium composite panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealant including suitable arrangement for grill fixing complete in all respect as per direction of EIC.
Supply and installation of trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ACP (3mm thick) for IDU maintenance.
SITC 250V 25A Timer controller for AC machine in SS double door 2+10-way DB enclosure with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :- (Make-L&T/ABB/Schneider) i) 20A DPMCB --- 1 No ii) 24 Hr programmable Digital Timer ---- 1 No iii) 3 pole power contractor with 1 NO +1 NC additional contact block ---- 1 set iv) 2 Moduler AC motor stater ---- 1 No. v) 2 Module plate with cover -- 1 No vi) 20A Auto-Off-Bipass SPDT toggle switch ---- 1 No. vii) 10A SPST Moduler type switch - 1 No. viii)Outgoing connector (Approved/reputed make) - 1 No
Supply & laying of 1.1KV single core stranded FR PVC insulated & unsheathed copper wire (RR Kabel/Finolex/KEI/Gloster)in 19/25 mm dia polythene pipe after cutting channel of suitable size, concealed in wall, incl. mending good the damages, as directed by EIC.
a) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC.
b)2x4 sqmm+1x 2.5 sqmm ECC)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Air Cooled Condensing Unit
Supply Installation Testing and Commissioning of Air Cooled Condensing Unit With Scroll Compressor ,Low Noise Condenser fan Complete with First Charge of R407C Refrigerant Gas (1W+1S) (Make: Voltas/ BlueStar/Hitachi)
Floor Mounted Air handling Unit for OT
Supply installation testing and commissioning of 0.8mm Double Skin Floor Mountted Air Handling Unit having: 1. 48mm thick panel with CFC free PUF insulation 2. 10 micron prefilter and 5 Micron Fine filter 3. 18 Gauge SS drain tray with nitrile rubber insulation 4. DIDW Backward Curved fan with 2 Nos of IE3 Energy efficient Motor(1W+1S) 5. 6 Row deep 0.5mm thick 9.5 mm dia Dx 2 nos. (1W+1S) Cooling Coil with 3 Nos Distributor 6. Mixing Box with Supply air, Return Air and Fresh Air Aluminium Damper (Make: Zeco/Edgetech/Ethos)
8.75 TR, 3400 CFM, 125mm Static
Copper Pipe and Accessories
Supply and installation of Hard drawn inter connecting Copper pipe of thickness not less than 19 Gauge
28.6 mm Dia
15.6 mm Dia
Supply and installation of 15.6mm Filter Dryer
Supply and installation of Refrigeration Type Ball valve
28.6mm Dia
15.6mm Dia
Supply and installation of 8.75TR Expansion Valve
Upvc Drain Pipe
Supply and installation uPVC pipe for Condensate Drainage
32mm Dia
Ducting and Acessories
Supply and installation of Aluminium Sheet for Duct Work
22 Gauge
20 Gauge
Supply and installation of Return Air Grille without Collar damper
Supply and installation of Volume Control Damper
Supply and installation of Fusible link Fire Damper
Supply and installation of Duct Mounted Strip Heater bank for OT AHU
4.5KW in 3 banks
Supply and installation of Duct mounted UVC Emitter
Laminar Flow Bench With HEPA Filter
Supply and installation of Laminar Flow Bench with perforated sheet to accommodate HEPA filter along with necessary support as per standard of minimum 6ftX8ft Dimension
Supply and fixing of HEPA filter of 0.3Micron down to 99.97% Efficiency of Size 550mmX550mmX150mm
Insulation work
Supply and installation of 19mm thick Class O fire Rated nitrile rubber Tube for Copper pipe
19mm Thick, 28.6 mm Dia
Supply and installation of 9mm thick Class-O Fire rated nitrile rubber tube insulation for Drain Pipe
9mm Thick, 32mm Dia
supply and installation of 13mm Thick Aluminium foil Faced Class O fire rated Nitrile rubber Thermal insulation
supply and installation of 10mm Thick Class O fire retadrant open cellNitrile rubber Acoustic insulation
Supply & installation of ACP (2mm thick) covering with frame structure by 1"x1'' Aluminium hollow square bar for covering of return duct of laminar airconditioning system as required and approved by EIC.
Electrical Work
Supply installation testing and commissioning of Distribution Panel Comprising of 1 Nos of incoming and 2 Nos outgoing Starter for OT AHU motor(1W+1S) and 3 Nos Power feeder for 8.75 TR Condensing Unit
Supply and installation of following Cable for Power supply and Control
4C, 16 Sqmm Armoured Aluminium cable
3C, 10 Sqmm Armoured Aluminium cable
3C, 1.5Sqmm Copper Cable for Control
Supply and installation of following Earthing Material
8 Swg earthing Wire
Civil and Structural Work
Charges Toward Civil/Structural foundation Work as required for the job
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
Shinryo Suvidha Engineers India Pvt Ltd
REFRIGERATION AND AIRCONDITIONING CORPORATION
WEATHER MAKERS INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .