Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18 CrAccepted-AOC | ₹18 Cr Quoted ₹18.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹20.4 CrRejected-AOC 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹20.4 Cr | L2 | Rejected-AOC L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-EMD amount shortage as per proceeding no. 1179/6A dated 21.03.2023 |
Tender Value
₹18.7 Cr
EMD Value
₹37.4 L
Closing Date
1 Mar 2023, 6:00 pmClosed
AJAYENDER SINGH SUHAG
Jhajjar W/S Divn. Jhajjar
Estimate for providing and laying of PCC Pressurised pipe line for supplying of treated waste water from Golf Course Road (i.e. junction at Sec-50/61, 57/61) to Police Training Center Bhondsi and upto Damdama Lake
2023_HRY_257972_1
202307AAC9DB F3FC 4DE0 9DFA 067E7877AAE7151IRR
Open Tender
Civil Works
303 days
Bhondasi Damdama
3 documents required · 3 mandatory
₹20,000
₹37.4 L
Yes
Office of Executive Engineer
26 Jun 2023
11 Feb 2023
3 Mar 2023
11 Feb 2023
1 Mar 2023
11 Feb 2023
11 Feb 2023 - 20 Feb 2023
20 Feb 2023
Amount
Road crossing by adopting trenchless technology tunneling work through specialized pipe jacking method by erecting the equipment to true to the alignment and gradient, by hydraulic pipe jacking technique complete including tunneling, excavation in all types of soils including hard rock and construction of RCC chambers suitable to casing pipe pits, and conveyance charges of machinery and other required materials but excluding cost of encasing pipe, in co-ordination with the concerned authorities as per approved drawings and directed by the Engineer-in –Charge. 800 mm dia
Road crossing by adopting trenchless technology tunneling work through specialized pipe jacking method by erecting the equipment to true to the alignment and gradient, by hydraulic pipe jacking technique complete including tunneling, excavation in all types of soils including hard rock and construction of RCC chambers suitable to casing pipe pits, and conveyance charges of machinery and other required materials but excluding cost of encasing pipe, in co-ordination with the concerned authorities as per approved drawings and directed by the Engineer-in –Charge. 1000mm dia
Supplying, laying, jointing, testing and commissioning in trenches including each work in excavation, fixing and testing MS plate gap pieces of 10mm thick for PCC pipes with epoxy coating on outer surface and lining on inner surface to be jointed with steel butt rings/ welding and testing the same as per specification by filling with water as directed by the Engineer-in-charge suitable for the 500 mm dia
Supplying, laying, jointing, testing and commissioning in trenches including each work in excavation, fixing and testing MS plate gap pieces of 10mm thick for PCC pipes with epoxy coating on outer surface and lining on inner surface to be jointed with steel butt rings/ welding and testing the same as per specification by filling with water as directed by the Engineer-in-charge suitable for the 600 mm dia
Supplying, laying, jointing, testing and commissioning in trenches including each work in excavation, fixing and testing MS plate gap pieces of 12mm thick for PCC pipes with epoxy coating on outer surface and lining on inner surface to be jointed with steel butt rings/ welding and testing the same as per specification by filling with water as directed by the Engineer-in-charge suitable for the 720 mm dia
Supplying, laying, jointing, testing and commissioning in trenches including each work in excavation, fixing and testing MS plate gap pieces of 15mm thick for PCC pipes with epoxy coating on outer surface and lining on inner surface to be jointed with steel butt rings/ welding and testing the same as per specification by filling with water as directed by the Engineer-in-charge suitable for the 1000 mm dia
300 HP ATS panel
Providing, fixing, commissioning and testing of Hydraulic split casing pump set discharge 15600 lpm (936 cum/hr), 10 Mtr head. with all fitting and accessories complete in all respect
Providing, fixing, commissioning and testing of In line Hydraulic split casing pump set discharge 18000 lpm (1080 cum/hr), 50 Mtr head. with all fitting and accessories complete in all respect
Operation and maintenance cost of project/work taking 2% of total cost per year i.e 1% for 6 months (half yearly) of the cost of project = 176418377*1/100
Providing and supplying prestressed concrete cylinder pipes suitable for sliding overlap weld joint or confined rubber ring joint with necessary rubber ring and diameter including cost of transportation, inspection charges to store, transit insurance, unloading and stacking including GST, plus Lowering, Laying and Jointing in proper grade and alignment prestressed concrete cylinder pipes (PCCP) with welding and mortar coating joints, plus Hydraulic testing of prestressed concrete cylinder pipes 500 mm dia 5.5 kg/sqcm
Providing and supplying prestressed concrete cylinder pipes suitable for sliding overlap weld joint or confined rubber ring joint with necessary rubber ring and diameter including cost of transportation, inspection charges to store, transit insurance, unloading and stacking including GST, plus Lowering, Laying and Jointing in proper grade and alignment prestressed concrete cylinder pipes (PCCP) with welding and mortar coating joints, plus Hydraulic testing of prestressed concrete cylinder pipes 600 mm dia 5.5 kg/sqcm
Bidder Name
Amount
G S KUMBHAR CONSTRUCTION COMPANY(GSTN-NA)
M/S SHREE BALAJI BUILDERS(GSTN-NA)
M/S SHREE BALAJI BUILDERS
G S KUMBHAR CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid