EXECUTIVE ENGINEER
O/o the EE, POWER DEPTT, K.E.E.D. KURSEONG, GTA.
INTERNAL ELECTRIFICATION WORKS OF COMMUNITY HALL AT CHOUKIDARA, KURSEONG, GTA.
2025_GTA_978119_1
9/NIET/EE/PD/KEED/GTA of 2025-26 (3rd Call)
Open Tender
Electrical Work/ Equipment
Percentage
30 days
CHOUKIDARA KURSEONG
AS PER NIET
5 documents required · 5 mandatory
₹750
₹5,622
Yes
22 Dec 2025
22 Dec 2025
27 Jan 2026
22 Dec 2025
23 Jan 2026
22 Dec 2025
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing capping and Switch board both on surface]
b) Average run 6 mtr
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]
(a) On Board
(d) Average Run 3 mtr.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.
(c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
(d) 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm)
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works
25x10mm Size
i) 2.5 sqmm
i) 4 sqmm
Legrand Make 2+8 way
S & F 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.
Legrand Make 6-32A SP
Legrand Make 40A DP
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
Supply & fixing sheet steel main switches on angle frame on wall 32A 240V (Havells Make)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode.
Supplying & fixing 50mm dia x 5.24 metre long (incl. bends) GI pipe vertical type service bracket on wall for carrying 2 wires and an earth wire complete with Galv. MS clamps for stay, insulators and earth wire, 7/14 SWG stranded GI (Hot Dip) Stay wire with 230x31 mm dia straining screws, 75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips, bolts, bush etc. incl. painting
Fixing exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing 2 * 1/1. 40 P.V.C. insulated and sheathed wire and making connection for exhaust fan of dia:-
Supply only 12W LED Bulb
Supply only 20W LED Tube Light
Supply only 50W LED flood light of Havells or similar make
Supply only Exhaust fan (Havells Ventil Air - DX white 200mm)
Supply only 2 core 10 sqmm aluminium unarmoured cable
Supply only decorative wall lamp of Havells or similar make
Supply only bulkhead light of havells or similar make
Supply only 400mm wall fan of Havells or similar make
Add District Charges @ 15%
Add GST @ 18%
Add Labour Cess @ 1%
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.13 MB
Tendernotice_2.pdf
PDF • 0.78 MB
BOQ_2383766.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .