Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.0 LAccepted-AOC 03 RAJA GARDEN EXT KAPURTHALA ROAD JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹5.3 L+₹27,585.16 (5.54%)Rejected-AOC 02 L D S ROAD GARWANPATTY TEZPUR SONITPUR ASSAM 784001 UDYAM AS 25 0020610 | SONITPUR | ASSAM | 784001 | L-2 | Rejected-AOC L-2 | |
| 3 | Rejected-Technical H NO 168 KAPURTHALA ROAD RAJA GARDEN JALANDHAR PUNJAB 144002 | JALANDHAR | PUNJAB | 144002 | - | Rejected-Technical Short documents | |
| 4 | Rejected-Technical | - | Rejected-Technical Short documents |
| Sl No | Description | Qty | Unit | HARJEET SINGH CONTRACTOR L1 | ASHOK AND CO. L2 |
|---|---|---|---|---|---|
| 1.00Sub Head-1 Internal Water Supply System | |||||
| 2.00EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. | |||||
| 3.00 | CPVC SDR 11 pipe & Fittings 25mm o/d | 75 | mtr | 222.23 ₹16,667.25 Lowest | 226.4 ₹16,980 |
| 4.00CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. | |||||
| 5.00 | SDR 11 CPVC pipes & fittings 16mm o/d | 25 | mtr | 181 ₹4,525 Lowest | 192 ₹4,800 |
| 6.00 | SDR 11 CPVC pipes & fittings 20mm o/d | 100 | mtr | 230 ₹23,000 Lowest | 236.4 ₹23,640 |
| 7.00Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75mm x 75mm | |||||
| 8.00 | qty same as CPVC P 16mm +20mm | 125 | mtr | 71.02 ₹8,877.5 Lowest | 80 ₹10,000 |
| 9.00Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. | |||||
| 10.00 | Through wall 11.43 cm thick | 15 | nos | 175.4 ₹2,631 Lowest | 180 ₹2,700 |
Tender Value
₹5.1 L
EMD Value
₹10,300
Closing Date
30 Jan 2025, 12:00 pmClosed
O/O EXECUTIVE ENGINEER WSS DIV NO. 1 JALANDHAR
O/O EXECUTIVE ENGINEER WSS DIV NO. 1 JALANDHAR
PROVIDING TOILET BLOCK FOR PERSON WITH DISABILITY 1 Nos toilet for Each Floor AT JUDICIAL COURT COMPLEX JALANDHAR
2025_WSS_132391_1
01-GOVTWORKS-2025
Open Tender
Civil Works
Item Rate
60 days
JUDICIAL COURT COMPLEX JALANDHAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹10,300
22 Aug 2025
7 Jan 2025
30 Jan 2025
7 Jan 2025
30 Jan 2025
7 Jan 2025
Amount
Sub Head-1 Internal Water Supply System
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
CPVC SDR 11 pipe & Fittings 25mm o/d
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
SDR 11 CPVC pipes & fittings 16mm o/d
SDR 11 CPVC pipes & fittings 20mm o/d
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition.Size 75mm x 75mm
qty same as CPVC P 16mm +20mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Through wall 11.43 cm thick
Through wall 22.86 cm thick
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
20mm i/d Brass Ball valves
25mm i/d Brass Ball valves
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. I) All classes of soil except rocky
Earth work upto 1.5 m Depth for
Sub Head-2 Sanitary Installation
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
Size 550 mm x 400 mm x 815 mm
Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
Vitreous chinaware standard white half pedestal for wash hand basin.
Providing and fixing jet spray with 2'-6" long PVC pipe.
With C.P. Brass nut
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect..
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. (e) PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 15mm Concealed stop cock with flange.
C.P.brass 20mm concealed stop cock with flange
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. i) C.P. Brass extension piece, 25mm long to 50mm long
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)
Size 600mmx450mm
Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
C.P. brass toilet paper holder
Providing and fixing in position automatic brass Ball Cock in tanks.
Brass Ball Cock with rod and Plastic Ball
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
G.I. tank nipple 25mm i/d
Construction of Platform complete as per Specification & as desired by Engineer-in charge
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973
Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-
25mm thick
Sub Head-3 Flooring & Tiles
Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechenical mixer for mixing of material.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Supplying and filling cinder on roof including light ramming
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Sub Head-4 Internal Sewerage System
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonagepipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.
Single Socket Type B
110mm o/d SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm o/d pipes
Elbow 90 Degree (All side socketed)
Vent Cowls
Coupler
P Trap/Floor Trap 110mm x 110mm
Single Y-Junction with door
Single Tee With Door
Single Tee
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge )
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. .
M.S. Holder bats clamps for 100mm i/d H.C.I. pipes
Cement concrete 1:2:4
a With stone ballast or shingle
mixing by mechanical means using concrete mixer volumetric type
Providing and fixing in position SS Brass Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.
35mm dia 600mm (24") long
Foldable U type 762mm long
Providing & Fixing in position . P./ Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.
Aluminium khunti with 4 pegs
ASHOK AND CO. (BID ID -613384)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .