Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹31.8 L+₹4,792 (0.15%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹34.9 L+₹3.2 L (10.1%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹35.2 L+₹3.5 L (10.9%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance not being lowest | |
| 5 | L5₹36.7 L+₹4.9 L (15.5%)Rejected-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L5 | Rejected-Finance not being lowest |
Tender Value
₹40.4 L
EMD Value
₹80,700
Closing Date
10 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Pune - 411 012
PROVISION OF CERTAIN LBW, REVENUE AND MINOR WORKS UNDER AGE E/M AT CME
2021_MES_416310_3
8171/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class E a(ii), b(i) and c(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹80,700
Yes
19 Apr 2021
24 Feb 2021
12 Mar 2021
24 Feb 2021
10 Mar 2021
25 Feb 2021
24 Feb 2021 - 24 Feb 2021
60 days
Amount
Material & Labour for Trial bore by mechanical drilling of size 200mm dia at location where as directed and suitable for insertion of 200mm bore MS ERW casing pipe in perfect vertical position in all types of soil/strata including hard stone/boulder/hard rock till meet with adequate water yeilding ground water table at depth n.exc 60m below ground level (02 bore well x 60 mtr each) Note: ground data/ strata for each 5-10 mtr will be recovered.
All as per serial item No 1above, but for depth exceeding 60 mtr (02 bore well x 40 mtr)
Note: For serial item no 1 & 2 (i) Actual bore well depth will be measured & paid (ii) The unit rate quotedshall be deemed to be included cost of all allied T&P, rig machines, vehicles, Gen Set and labours required for drilling bore. (iii) Casing MS ERW pipe 200mm bore shall be measured and paid separately under respective items.
(iv) The location of the borewells should be approved/confirmed by water department of Geological survey of India or other equivalent Govt Institute. Detailed Report of the same should be submitted to GE (CME) before digging of the borewells. (v) The cost of the same is deemed to be included in quoted rate. No extra claim on this account would be admissible beyond quoted rate.
Flushing drilled bore well by using air rig compressor for minimum 16 hours period complete all as directed (02 bore well x 16 hour per bore for developing and increasing discharge of bore) Note: The log book indicating time commencing and closing at end of air flushing shall be maintained and shall be signed by contractor and Enginner-in-charge for the purpose of measurement of unit and payment
T&P including labour for conducting yield test for 16 hours by using suitable capacity pump set including preparation of yeild test report and subsequent evaluation/ recommendation report for capacity of submersible pump set required to be installed complete all as directed. Note: The unit rate quoted shall be deemed to be included for rent charges for T&P used for testing pumps viz pump and allied T&P incl water sample testing for chemical and biological analysis for potability.
Material & Labour for 200mm bore MS ERW pipe with shell 5.40mm thick and lowering into bore holes in perfectly vertical position upto required depth below ground level and welding the same at least 500 mm in rock incl cutting, threading, coupling,welding complete all as specified and as directed.( 02 bore well x 100 mtr)
Material and labour for pea gravel of size 5mm to 7mm bore of approved quality free dust and other foreign matter all around casing pipe complete all as specified and directed
M & L for well cap made out of 6 mm thick MS plate suitable for 200mm bore casing pipe made to shape including preparation and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Supply and fixing nylon rope of 25mm dia for bore well pump complete all as specified and directed.
M & L for holding clamp fabricated by mild steel plate of 20 mm thick of size 125 cmx 25 cm in two halves, having four numbers (two at each end) 24 mm x 150 mm bolts, nuts, and washers suitable for clamping and holding of casing pipe all as specified and directed.
Material and labour GI bends (any type radius and angle) taper any type (straight, bend, increasing, decreasing or double flanged etc) tee pieces, single branch "Y" Junction double branches cross up to 80 mm bore complete all as specified and directed.
Supply and fix 80mm dia HDPE hose pipe ISI marked 6 kgf/ sqcm for bore well pump sets complete all as specified and directed.
Supply,install,testing & commissioning of submersible pump set of approved make suitable for tube well working at 415 volts AC 3 phase, 50 Hz for discharge at head not less than 75 mtr with bronze impeller water filled motor outlet suitable for 80mm bore column pipe of capacity 5 HP complete all as specified and directed.
Supply and Fix Submersible Pump Starter For 5 HP capacity Motor complete all as specified and directed.
Supply, install, testing & commissioning of self supporting outdoor type LT panel board totally enclosed compartmentalised double door design, dust and vermin proof of size not less than 90 × 90 × 25cm suitable for 440 volt 3 phase 4 wire made out of 3.15mm CRCA sheet and built upon rigid frame work having front doors with neoprene rubber gasket including danger plate,earthing strip point at side, ventilation louvers at the side,bottom detachable gland plate complete with suitable size of zinc plated nuts bolts and washers etc. The panel shall be painted with two coats of zinc chromate primer and final finish of grey paint and the power and control circuit diagram shall be accompany the eqpt and circiut wiring with colour code solid conductor copper cable for easy identification including incoming/outgoing cable holes at the bottoms. The panel shall be embedded with 40x40x5mm thick MS channel and 30 cm above the ground level complete with PCC foundations (1:2:4) type B2 incl all connections with lugs complete with following:
Copper bus bar 200amps -04 Nos supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bus bar shall be colour coded (red,yellow and blue) for three phase and black for neutral.
Housing for motor starter - 1 No.
MCCB TPN 63 amps 16 KA, 415 volts-1 No.
MCB SPN 20 amps,240 volts -04 Nos.
LED indicating lamps-3 Nos (RYB)
Panel mounting stand made out from MC 100 upto 0.6mtr height - 01 Job.
Panel wiring with copper multistranded cable of suitable size - 01 Job
Supply and Fix copper cable 6 Sqmm 3 core for submersible pump set all as specified and directed.
Supply and laying in trenches Galvanised steel (Gl) tubing 'Medium grade' with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) with cutting, screwing, making forged bends on piping as required. insertion of Connectors where required or directed. including cutting through walls, floors, etc. and making good all as specified and as directed for following size of pipes: (Note : Earthwork shall be measured and paid separately under relevant Item)
15mm bore
25mm bore
40mm bore
Supply and fixing including testing of 15 mm dia gun metal gate valve with iron wheel head screwed both ends for GI pipe complete all as specified and directed.
Supply and fixing including testing of 25 mm dia gun metal gate valve with iron wheel head screwed both ends for GI pipe complete all as specified and directed.
Supply and fixing including testing of 40 mm dia gun metal gate valve with iron wheel head screwed both ends for GI pipe complete all as specified and directed.
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of GI/ CI/DI pipe line and making bottom surfaces of excavation levelled complete all as specified and directed.
Excavation in trenches in Hard/ dense soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of GI /CI/DI pipe line and making bottom surfaces of excavation levelled complete all as specified and directed.
Returning filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose/hard/dense soil complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Supply and fix lawn water sprayer gun metal body with double brass nozzle rotating type with 10m diameter coverage including MS stand with round base and of height 15" all as specified and directed.
Supply of light weight heavy duty compact, durable construction, easy to store flat hose set 50 feet along with both side quick connectors complete all as specified and directed.
Supply, installation, testing and commissioning of Walk - in cold room of three chambers comprises with the following:-,
Walk In Chiller room of size 10'x10'x8' (external dimension) consisting of wall and ceiling panel made out of PUF filled panel with external Precoated GI sheet of 0.4mm and internal SS 304 (stainless steel) filled with 60 mm PUF insulation, anti skid Kota stone flooring on 60 mm PUF bare slab, having manual swing type insulated door, PUF insulated panel cladded with both side PGI sheet,complete with frame,kock plate & all accessoriess like locks & hinges with Key of dimension 900mm(w) x 2000mm(h)x 60mm thick,hydraulic door closer, digital temperature indicator,Air cooled low temperature split unit(condensing unit) for cold room of 2 HP rating Compressors (2 Nos one running and one standby) having 15000 BTU/Hr refrigeration capacity working on R404 refrigerant gas to maintain temperature of 4° C at an ambient temperature of 43° C including two set of Evaporator unit with fan motor (Evaporators of ceiling suspended type), Solenoid valves, control valve,copper pipe,condensate drain PVC pipe, oil, PVC curtain etc complete all as specified and directed.
Walk in Freezer room of size 10'x8'x8' (external dimension) consisting of wall and ceiling panel made out of PUF filled panel with external Precoated GI sheet of 0.4mm and internal SS 304 (stainless steel) filled with 100 mm PUF insulation, and Ante Room of size 6'x6'8'(H) consisting of wall and ceiling panel made out of external PGI sheet 0.4mm and internal SS304 sheet filled with 60 mm PUF insulation, anti skid Kota stone flooring on 100 mm PUF bare slab, having manual swing type insulated door, PUF insulated panel cladded with both side PGI sheet,complete with frame, kick plate & all accessoriess like locks & hinges with Key etc of dimension900mm(w) x 2000mm(h)x 60mm thick for Freezer room and 900mm(w) x 2000mm(h)x 120mm thick for Ante room,hydraulic door closer, digital temperature indicator,Air cooled low temperature split unit of 3.5 HP rating Compressors (2 Nos, one running and one standby) having 12000 BTU/Hr refrigeration capacity working on R - 404 refrigerants to maintain temperature of (-) 18° C to (-) 20° C at an ambient temperature of 43° C. including two set of Evaporator unit with fan motor (Evaporators of ceiling suspended type), Solenoid valevs, control valves,copper pipe,condensate drain PVC pipe,oil,PVC curtain etc complete all as specified and directed.
Note :(i) Kota stone floor measured and paid separately (ii) Sketch of Walk in Chiller and Freezer room enclosed.
M & L for Machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab rubbing and polishing complete all as specified and directed.
M & L for Screed bed or bedding layer of cement mortar (1:4), 20 mm thick, laying on PUF panels as in under layer of Kota stone Slab floor complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc, and removing from site incl depositing where directed not exceeding 200mtr.
M & L for rendering 15mm thick plaster on any faces of brick/stone wall or concrete surfaces with CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and directed.
Supply & fix sheet metal enclosures for DB's when MCBs to be used Single pole & neutral, Double Door, 4 way with 200 amps rated bus bar complete all as specified and directed.
Supply and fix MCB isolator Tripple pole and neutral 415Volts, 32 Amps complete all as specified and directed.
Supply, fix and connecting Moulded case circute breaker 4 Pole, 415 Volt, Breaking capacity 10kA with fixed thermal & Fixed magnetic setting, Capacity 63Amps & fixed in existing KIOSK. Make Havells Cat ref IHLGSF0063 or equivalent of L &T/ Standard complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode of size 60x60x.6cm thick burried directly in ground vertically at a depth of not less than 2.25 mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron strip 25x3mm as earthing lead by means of nuts, bolts & washers incl GI protection pipe 40mm dia light grade to earth wire 20mm dia GI watering pipe with funnel and wire mesh PCC pit 1:3:6 with pit cover of size 30x30cm made of RCC 1:3:6 with suitable handle angle iron frame of size 40x40x4mm thick adequate qty of charcoal dust and salt in alternate layers all around the earth plate including excavation in any type of soil strata, removal of surplus soil and returning filling in all as require at site all as specified in electrical plate No 3 of SSR Part-I (2009) all as directed by Engr-in-Charge.
M & L for point wiring for light/ fan/ bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed multi stranded copper conductor 1100 volts grade in and incl not less than 2 mm thick PVC casing/ caping with all accessories and 1.5 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surfaces/ flush type with PVC sheet for mounting fittings such as switches, sockets fan regulators etc complete all as specified and directed for one light/ fan/ bell point controlled by one switch & making good to disturbed surface of wall etc. all as specified and directed.
S & F switch piano button flush type single pole one way 5 amps complete all as specified and directed.
Supply & fix fan ceiling complete with accessories 230 Volts, 1200 mm sweep BEE 5 star rated complete all as specified and directed.
S & F stepped type electronic fan regulator flush type complete all as specified and directed.
S & F U type fan hook with flat iron plate and 02 Nos fastners complete all as specified and directed.
S & F down rod made out of GI pipe medium grade 15 mm dia with fan clamps incl drilling, cutting threading & with painting etc for ceiling fans 1200 mm sweep all as specified and directed by Engr-in-charge.
Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with 5 star rating and EER 3.2 of capacity 1.5 TR including additional copper piping, cabling work, insulation & from indoor to outdoor unit fixing clamp complete all as specified and directed.
Supply & fix voltage stabliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy of (+-) 5 and of capacity 5 KVA wall mounted complete all as specified and directed.
M & L for wiring for circuit/ sub main wiring of size 2 X 6.0 sqmm + X 4.0 sqmm alongwith earth wire of FR PVC insulated copper conductor single core and including rigid PVC casing caping complete all as specified and directed.
S & F incl connecting sheet metal enclosure with two pin and earth plug and socket complete with one double pole MCB 32 Amp complete all as specified and directed.
M & L for making holes by core cutting machine on stone/ RCC walls dia of hole not exc. 50mm and thickness up to wall 50cm for entry of suction and discharge pipes of AC and making good disturbed surfaces with cement mortar and finally with POP complete all as specified and directed.
Supply, installation, testing and commissioning of Roof Turbo Ventilator 24" (600mm) size with FRP base plate including cutting of existing sheet with all fittings complete of following specifications: 1. Turbine Dia - 760mm 2. Neck/ Throat - 600mm 3. Height - 460mm 4. Vanes/blades - 42 vanes, Aluminium 0.5mm thickness 5. Base ring MOC - Stainless steel SS202 6. Top plate MOC - Stainless steel SS202 7. Rotation - Frictionless Rotation Even at lowest wind velocity 8. Inner arms - MS with electro zinc plating 9. Outer arms - MS with electro zinc plating 10. FRP base plate - 2mm thick, clear, 1.020m wide & 1.65 mtr long matching our sheet profile, weight 6 kg Approx
11. Ventilator - 6.25 kg Approx 12. center width - 800mm (-+) 5mm 13. Dia of bottom ring - 600mm (-+) 5mm 14. Rivets - Aluminium alloy with washer 15. Center shaft - MS with electro zinc plating 16. Bush mounted - self lubricated teflon bush
Notes : (i) Height of the roof of gym hall is around 24-26 mtr approx (ii) Crane or Ladder alongwith vehicle will be bome by contractor and same will be included in quoting rate.
Supply & fixing of 16 M high two section pole suitable for raising lowering system comprising head frame luminaires carriage to install 6 luminaires in symmetrical arrangement, double drum winch, 5mm dia stainless steel wire rope ,trailing cable, connector, integral power tool manual handle, junction box, lighting finial wiring material, power cable between, panel and pole fittings MCB should be in base compartment of suitable capacity, Cg mounting Clamp & bolts all as specified and directed.
Supply and fixing foundation bolts manufactured from special steel along with nuts, washers, anchor plate and template all as specified and directed suitable for high mast pole.
Supply and fix LED aviation obstruction lights of cat No 110731 type BGAV 302 LED comprising of aluminium housing with carbonite enclosure with one no 23 Watts LED lamps fitted on top edge of 16 m high two section pole all as specified and directed.
Supply and fix outdoor stand mounted feeder pillar with 32 Amps TPN MCB incommer, single dial time switch, 25 A TP contactor for the automatic switching of luminaires, power tool control with 2 Nos 9 A contactor and raise lower push button incomming 35 Sqmm and out going 16 & 2.5 Sqmm terminals ( Type STD 4).
Supply and fix Accessories like Head frame, cable, Lantern, carriage, Wire rope,Compensation Disc,Winch Motor,Junction Box etc suitable for high mast pole
Supply and fix LED flood light fitting 200 watt 6000 K complete of make Bajaj cat part No 169929-BJFL 200W LED or equivalent in Havells/ Philips
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polyethylene including coupler and bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified
Excavation in trenches n.exc 1.5 mtr. in depth and not exceeding 1.5 mtr in width and getting out in soft / loose soil for laying of cables / erection of pipes/ poles, stays etc all as directed.
Excavation in trenches n. exc 1.5m wide and exc 1.5 mtrs and not exceeding 3 mtrs in deep and making good surface for plinth/ foundation of pole in hard/ dence soil all as specified and directed by Engr- in -Charge.
Returning, filling in, spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soil all as specified and directed.
Removing excavated materials/ surplus soil and depositing where directed at a distance not exceeding 50 mtr at a level not exceeding 1.5 mtr. From starting point.
M & L for PCC 1:4:8 type D2 using 40 mm graded stone agrregate as in foundation, filling and mass concrete etc complete all as specified and directed.
M & L for PCC 1:3:6, type C1 using 20 mm graded stone aggregate as in in plinth, platform for erection of two section 16 metres high pole including necessary use and waste of form work all as specified and directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core all as specified and directed.
M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron strip of 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30x30 CM made of RCC 1:3:6 with suitable handle, angle iron frame of angle iron size 40 x40x4mm, adequate qty of charcoal dust and salt in alternate layers all around the earth plate including excavation in any type of soil strata, removal of surplus soil and returning filling in all as required at site all as specified in plate No 3 of SSR Part-I and directed by Engr-in-Charge.
Supply and fix LED flood light fittings 180 watt, 6000K complete of make Bajaj Cat part No. 169928-BJFL 180W LED or equivalent Havells/ phillips all as specified and directed.
UNIQUE ENGINEERS
Pritam Electro Mechanical Services
metro electrical services
Mukund Engineers and Contractors
Sachin Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .