| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.5 L+₹1.9 L (14.1%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹17.0 L+₹3.4 L (25.1%)Rejected-Finance NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹17.5 L+₹3.9 L (28.9%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹17.9 L+₹4.3 L (31.6%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
5 Dec 2022, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/REPLACEMENT OF INTERNAL ELECTRIFICATION WITH FITTINGS AND FIXTURES AND ELECTRIC GEYSER SOLAR WATER HEATER IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2022_MES_563265_1
GE/EM/LKO/HOSP/T-54 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹60,000
Yes
22 Dec 2022
15 Nov 2022
7 Dec 2022
15 Nov 2022
5 Dec 2022
29 Nov 2022
Amount
Taking down carefully aluminium/Copper conductor point wiring (light, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing materials from site and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing complete all as specified and directed.
M&L point wiring for one light/fan point controlled by one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surfce as made existing same colour complete all as specified and directed. (Note :- Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tenderer).
All as per item No 2 above but one socket outlet point 5 amps on independent board
All as per item No 2 above but one socket outlet point on same board
M&L point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly complete all as specified and directed.
S&F Polycarbonate switch piano flush type, SP,5/6 Amps, one way complete all as specified and directed.
S&F Polycarbonate switch piano flush type, SP, 16/20 Amps, one way complete all as specified and directed.
S&F Polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch, complete all as specified and directed.
S&F Polycarbonate socket out let 6 pin, 20 Amps complete all as specified and directed.
S & F ceiling rose, Pilot 3 Plate ceiling rose 6A, complete all as specified and directed.
S&F in repair Moduler switch 10 Amp, SP, one way , 220 Volts AC, square white mechanisms & ISI marking complete all as specified and directed.
S&F in repair Moduler switch Modular switch 1 way 16A, 1 modules square white mechanisms ISI marking complete all as specified and directed.
S&F in repair Moduler socket shuttered 6 Amps, 3 Pin Universal India -2 module, ISI marking complete all as specified and directed.
S&F in repair Moduler socket shuttered 6/16 Amps, 3 Pin Universal India -2 module, ISI marking complete all as specified and directed.
S&F in repair Ceiling fan regulator electronic type deluxe 240, 5 step, Volts ISI Marked specified make complete all as specified and directed.
S&F in repair White cover plate with frame, 2 module, complete all as specified and directed.
S&F in repair White cover plate with frame, 3 module, complete all as specified and directed.
S&F in repair White cover plate with frame, 4 module, complete all as specified and directed.
S&F in repair White cover plate with frame, 6 module, complete all as specified and directed.
S&F in repair White cover plate with frame, 8 module, complete all as specified and directed.
S&F in repair Switch socket combination 2 in 1 , 3 pin , 5 & 15 amp flush type universal, complete all as specified and directed.
S&F in repair socket outlet multipurpose 3 pin , 20/10 Amps ISI marking, controlled by one switch complete all as specified and directed.
S&F in repair socket outlet multipurpose 3 pin , 6 Amps and one pin, controlled by one switch ISI marking complete all as specified and directed.
S&F in repair Polycarbonate switch piano flush type, SP,5/6 Amps, one way complete all as specified and directed.
S&F in repair Polycarbonate switch piano flush type, SP, 16/20 Amps, one way complete all as specified and directed.
S&F in repair epoxy powder coated distribution box Double door type SPN 4 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door complete all as specified and directed.
S&F in repair epoxy powder coated distribution box Double door type SPN 8 way,with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door complete all as specified and directed.
S&F in repair epoxy powder coated distribution box Double door type SPN 12 way, with 200 amps rated bus bar,240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal door complete all as specified and directed.
S&F in repair MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F in repair MCB, single pole & neutral 32/40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F in replacement of sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
M&L in repair for concealed sub main wiring comprising two single core, 4 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS Grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 2.5 Sq mm nominal cross sectional area n green coloure on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note :- (i) Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tendered. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
M&L in repair for concealed sub main wiring comprising two single core, 10 Sq mm nominal cross sectional area multi on same copper conductor cable, PVC insulated FRLS grade unsheathed 1100 Volts grade drawing in and over PVC conduits and conduit fittings complete (concealed type) including S&F 6 Sq mm nominal cross sectional area on same copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. (Note :- (i) Cutting chases and making good of disturbed surfaces shall deem to be including in the unit rate quoted by tendered. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
M&L in replacement earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate not less than 1.50 m below ground level, connected to GI lead wire of 4 mm dia. (7.50 m long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 1.5 mm nominal bore (7.50 m Long) for earth plead wire, watering pipe light grade of 20 mm nominal bore, 0.63 mm thick CI funnel, wire mesh etc complete including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 50 mm thick dully reinforced with 6 mm dia, MS round bars @ 100 mm C/C both ways, earth testing point as per electric plate No 3 of SSR Part-I, making good to floor complete all as specified and directed.
M&L in repair distribution Board TPN with and including of DPX MCCB 35 KA 250 Amps MCCB FP, as incomer and SP/TPN MCBs as outgoing protection class IP 54, 8 way (DPX 250+24) with metal double door as in replacement, complete all as specified and directed. Note :- FP MCCBs 35 KA 250 Amps 1 No and 24 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this this item .
M&L in repair Distribution Board TPN with and including of DPX MCCB 35 KA 160 Amps MCCB FP, as incomer and SP MCBs as outgoing , 4 way with metal double door as in replacement, complete all as specified and directed. Note :- FP MCCBs 35 KA 160 Amps 1 No and 24 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this this item
M&L in repair Distribution Board TPN with and including of 100 amp FP Isolator, as incomer and SP MCBs as outgoing , 4 way with metal double doorwith metal double door as in replacement, complete all as specified and directed. Note :- FP Isolator 100 Amps 1 No and 12 Nos MCB SP 32 Amps 230 Volts and Blanking plate shall be measured and paid under this this item
Supply and fixing in repair flexible copper cable three core 0.75 sqmm white coloure flat type suitable for connection for electric fititing and fixture complete all as specified and directed.
Supply and fixing in repair flexible copper cable three core 1.5 sqm suitable for connection for electric fititing and fixture complete all as specified and directed.
Supply and fixing flexible copper cable three core 2.5 sqm suitable for connectionfor electric fititing and fixture complete all as specified and directed.
Supply and fixing in repairs 15 amp plug top complete all as specified and directed.
Supply and fixing in repairs 5 amp plug top complete all as specified and directed.
Supply and fixing in repair suitable for 5 amp gang box with switch and socket complete all as specified and directed.
Supply and fixing in repair suitable for 15 amp gang box with switch and socket complete all as specified and directed.
S&F LED 4 pin 18 watts 4 Pin , suitable for light fittings witn electric connection complete all as specified and directed.
Supply and fixing in repairs of Recess LED llight fittings of size 2X2 36 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/material proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept complete all as specified and directed.
Supply and fixing in repairs of Recess LED llight fittings of size 2X2 20 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept complete all as specified and directed.
S & F in repair Recess LED llight fittings of size 2X2 20 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept all as specified and directed. 2X2 22 watt warm cool type complete all as specified and directed.
S&F in repairs of recess type square LED 12W downlighter 6500/4000K complete all as specified and directed.
Supply and fixing in repairairs of Recess LED llight fittings of 4X1 of 30 watt LED made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture including cutting and making false ceiling of any pattern/mtrl proper fixing of light in falce ceiling , electrical connection up to 15 feet height of various ward and dept complete all as specified and directed.
S&F in repair Lamp holderbattern/anguler type, PVC/polycarbonate type with cord grip cap suitable for pendant fittings, complete all as specified and directed.
S&F in repair LED tube light Rod 18/20 watt 4 feet retro type complete all as specified and directed.
M & L for Taking down , Overhauling, repairing, reassembling, incl welding/brazing work of leakage body , Refixing, of water heaters / Geysers to their original position after repair, making all necessary water & electric connections and testing complete all as specified and directed. (Note :- Defective parts shall be measured and paid separaetly under respective item)
Supply only heating element 1.5 KW (ISI marked) suitable for geyser of 25 litres capacity, horizontal or vertical type any make complete all as specified and directed.
Supply only heating element 2 KW (ISI marked) suitable for geyser of 50 litres capacity, horizontal or vertical type any make complete all as specified and directed.
Supply only Thermostat, minimum 300 mm long, suitable for any make & type of geyser 25 / 50 litres capacity horizontal or vertical type complete all as specified and directed.
Supply only indicating lamp for geysers of any type make & capacity complete all as specified and directed.
M&L for spray Painting of old surfaces of geysers of 25 litres capacity of any make with one coat of paint of approved shade or tint after necessary preparation to surfaces and writing of MES Nos as approved size of letter complete all as specified and directed.
S&F in repair of PVC connection 15 mm dia with 2 Nos brass coupling, nuts from geyser inlet / outlet, 40 cm length suitable for 15 mm bore GI pipe complete all as specified and directed.
S&F in repair of chromium plated stop cock with brass spindle & with crutch or butterfly handle screwed down high pressure suitable for 15 mm bore GI tubing complete all as specified and directed.
S&F in repair Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia. Iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair non-return valve, gun metal, suitable for 15 mm bore GI tubing complete all as specified and directed.
S&F in repair pressure releasing valve ISI marked as per sample (15mm) complete all as specified and directed.
Supply only copper tank verticle type suitable for 25 ltr Geyser complete all as specified and directed.
Supply only copper tank verticle type suitable for 50 ltr Geyser complete all as specified and directed.
S&F condenser/capacitor suitable for 230 volts single phase ceiling fan 1200mm /1400 sweep of any make and quality of capacity 2.5 MFD complete all as specified and directed.
All as per item No 66 above but but 3.15 MFD
M/S S.B. Singh and Sons
NEXT POWER ENTERPRISES
NAVJYOTI ENTERPRISES
M/s A.K Construction
ARTI ENTERPRISES
Ajanta Associates
Eco Creations
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .