Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.9 LAdmitted-Finance | -13.00% | ₹4.9 L | L1 | Admitted-Finance |
| 2 | L2₹5.0 LAdmitted-Finance | -11.92% | ₹5.0 L | L2 | Admitted-Finance |
| 3 | L3₹5.2 LAdmitted-Finance 0 73 JONSTONGANJ ALLAHABAD ALLAHABAD UTTAR PRADESH 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | -7.66% | ₹5.2 L | L3 | Admitted-Finance |
Tender Value
₹5.7 L
EMD Value
₹11,400
Closing Date
27 Feb 2026, 5:00 pmClosed
AGM (EM) FCI RO Mumbai
FCI REGIONAL OFFICE MUMBAI
Rewiring and Renovation of Internal and External Electrification Works of Depot Office at FCI FSD Ajni New
2026_FCI_899021_1
01/13/EE/2025-26
Open Tender
Electrical Works
60 days
FCI FSD AJNI NEW
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹11,400
10 Mar 2026
17 Feb 2026
2 Mar 2026
17 Feb 2026
27 Feb 2026
17 Feb 2026
Supply, installation, testing and commissioning of wall mounted sheet steel enclosure type main distribution board comprising with 1 No. 63A, 16kA, 415V, Four Pole MCCB with thermomagnetic release and terminal spreaders as incomer and 6-way 63A copper busbar on outgoing side for distribution complete with internal wiring, earthing, cable terminations, and all accessories etc.as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4+12), Double Door
Supplying and fixing following size/ modules PVC box etc. as required
12 module
8 module
6 module
4 module
Supplying and fixing following Modular base & cover plate on existing modular PVC boxes etc. as required
12 module
8 module
6 module
4 module
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
Bell Push
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on existing modular plate switch box including connections but excluding modular plate etc. as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, standard ceiling fan , class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 3.50, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing and Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Supplying and fixing call bell/buzzer suitable for single phase 230 volts complete as required.
Supplying of 450 mm (18") 4 blade exhaust fan suitable for bathroom complete with all acessories etc. as required. (Recommended uses for Exhausting, Mounting type Window Mount) High Quality metallic body with corrosion protecton and rust proof body Sweep size: 450mm Motor Speed: 900 RPM, Warranty: 2years
Supplying of 380 mm (15") 4 blade exhaust fan suitable for bathroom complete with all acessories etc. as required. (Recommended uses for Exhausting, Mounting type Window Mount) High Quality metallic body with corrosion protecton and rust proof body Sweep size: 380mm Motor Speed: 900/1400 RPM, Warranty: 2years
Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
Upto 450 mm sweep
Supplying and fixing of 5A to 32 A rating 240/415V, 10 kA, "C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc as required.
Single Pole
Supplying and fixing following rating double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double Pole 25 A
Supplying and fixing following rating, four pole, 415 V, 10kA, "C" curve MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Four Pole 63 A
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 6 sqmm + 1 X 6 sqmm earth wire
2 X 4 sqmm + 1 X 4 sqmm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 2.5 sqmm + 1 X 2.5 sqmm earth wire
Supplying of XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
2x10 sqmm
2 x 6 sqmm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.
Up to 35 sq mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Up to 35 sq mm (clamped with 1mm thick saddle)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
20 mm dia nominal bore
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing of out door type loop in loop out cable junction box (20cmx15cmX10cm)fabricated from 1.6 mm MS sheet enclosed wheather proof, dust proof, water proof and locking arrangement internally embedded gasket with bottom cable entry plate through cable glands fixed with clamps on steel structure and wall. Seperate for incoming and out going cables and wires duly fitted with following in it. HD Connector for 10 to 16 sqmm - 4 Nos. 6 amp SP 'C' curve 10 KA MCB - 1 No. fixing Clamps - 2 Nos.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2x10 sqmm
2x 6 sqmm
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, Installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70,under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supplying of 40 W LED post-top light fitting with IP 65 protection having energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source with opal cover diffuser. (Input voltage range 140-310 V AC, Cool Daylight (6500-7500K), Light Color: White, Lumen Output>=100 Lumens/Watt) with 2 years manufacturing warranty etc. as required.
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Downlighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc.as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim
Installation, testing and commissioning of all types lighting fixtures, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing 32 mm dia X 2.00 metres long GI pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required.
The items are to be dismantled where the work has to be executed and take away by the giving the credit to the work estimate
Old Aluminium Cables and wires
Old light fittings
Old Switchboard, switchgears,PVC conduits
Old fan
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
MTF.pdf
Tender Documents • 1.28 MB
BOQ_944978.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid