| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC BMC 1 54 GANTI NETAJI PALLY PO GANGANAGAR KOLKATA 700 132 INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700132 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹11.4 L+₹96,728 (9.25%)Rejected-Finance 21 20 BT ROAD KHARDAH PO TITAGARH PS KHARDAH DIST NORTH 24 PARGANAS KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L2 | Rejected-Finance OTHER THAN L1 BID |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
9 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CGN) KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
PROVN OF WASHROOM AT CGRA MANICKTALA UNDER GE (I) (CGN) KOLKATA
2022_MES_557105_2
8029/B/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (CGN) KOLKATA
AS PER TENDER DOCUMENT
11 documents required · 11 mandatory
₹500
GE (I) (CG N) KOLKATA
₹20,000
Yes
9 Feb 2023
14 Dec 2022
10 Jan 2023
14 Dec 2022
9 Jan 2023
21 Dec 2022
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of vertical surface complete all as specified and as directed (Area of the sub structure in contact with backfill to be measured).
M & L for treating the top surface of filled earth at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface complete all as specified and as directed.
M & L for treating the soil under plinth protection at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed.
M & L for treating the soil along with external perimeter of building at the rate of 2.25 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per metre of the perimeter wall complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, etc. complete all as specified and as directed.
S & F bottle trap of PTMT suitable for 32 mm dia of discharge pipe, having minimum water seal of 25 mm and minimum weight 260 gms complete all as specified and as directed by Engineer-in-Charge.
M & L for 40 mm thick damp proof course in cement concrete M15(Nominal mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with integral water proofing compound to horizontal or vertical surfaces including necessary formworks complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Supply only integral water proofing compound.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45⁰ angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick wood grain printed PVC sheet and edge will be printed to match with printed sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed by Engineer-in-Charge.
M & L in repairs for copper connection pipe, chromium plated, 15 mm size with brass nut at both ends of length 450 mm complete all as specified and as directed.
S & F angular stop cock with wall flange as per catalogue No. SKU: QQT-CHR-7053 of Jaquar or equivalent Make of Kohler or Marc complete all as specified and as directed.
S & F two way bib cock as per catalogue part No. G3034A1 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed.
S & F sheet glass shelf assembly as per Jaquar cat No AKP-35771P or equiveklent consisting of 5.50 mm thick glass sheet shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed.
S & F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
S & F pillar cock (long neck), quarter turn, made of brass, chrome finish as per Model No. KUB-CHR-35021F of Jaquar or equivalent Model of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F towel ring as per catalogue part No. T6402A1 equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed.
S & F soap dispenser as per Model No. T6413A1 of Parryware or equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed.
S & F chromium plated toilet paper holder as per Jaquar Model No. AQN-CHR-7753 or equivalent of hindware complete all as specified and as directed.
S&F urinal valve auto closing system with built up-in-control cock and wall Flanged in PVC cleat complete all as specified and as directed. Make; Jaquar cat part No PRS-077.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 200 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S&F powder coated aluminium window/ ventilator shutter, sliding type with style rails sash bar, 3tier sliding frame etc. all are made from powder coated aluminium section weightinh not less than .55 kg/ RM including all necessary jointing cleat glazing rubber packing aluminium snap beading screw aluminium handle locking arrangement etc complete all as specified and as directed
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S&F half stall urinal pot of size 355x340x535 mm fixed with bracket including necessary fittings complete all as specified and as directed. Make Jaquar Cat part No URS-WHT-13261
S & F CPVC special transition fittings, elbow/Tee/socket//reducing socket MBTA/ FBTA/ Unioun/ Adapter etc. with brass threading, 20 mm nominal size complete all as specified and as directed.
M & L for sand filling under floors or in foundations, under cable including watering and consolidation complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
M & L for non skid, rectified, colour ceramic floor tiles (group B II), 300 mm X 300 mm X 7 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:4) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
M & L for glazed, white ceramic wall tiles (group B III), 300 mm X 450 mm X 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed
M & L for preparation of new or previously untreated plastered/gypsum ceiling surfaces and applying two coat of oil bound distemper over a coat of suitable dry wall complete all as specified and as directed.
M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 10 mm thick cement plaster in CM (1:4) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 4 mm thick (not less than 5 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25 C, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately)
M & L cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M & L for concrete bed to drain pipes of internal diameter 160 mm, in cement concrete M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
M & L for 150 mm internal dia salt glazed stoneware pipes, class SP1 as per IS 651: 2007 laid in trenches and jointed with cement slurry and yarn complete all as specified and as directed.
Cutting into existing manholes for connecting new drains of pipe of nominal size 100 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
S&F bowl for extended wall hung WC (pedestal pattern) size 375x620x770 mm white fixed with brass screw with necessary connection with water line and sewer line with PP soft close seat cover including hinges fixing with set and cistern fittings including S trap complete all as specified and as directed. Make Jaquar cat part No CNS-353S&353N)
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
M & L for cast iron floor trap 100 mm nominal diameter with grating including jointing to waste pipe with lead joints and including necessary concreting in M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F UPVC Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F UPVC reducer, 110 mm to any dia on opposite ends conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S&F counter/table table top wash hand basin fixed at the top of granite counter incl brass chromium plated waste fittings 32mm dia with long screw shaks complete all as specified and directed (Make: Jaquar:Cat No CNS-WHT-905)
S & F grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
S & F 15 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F UPVC vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
M & L for Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone, size not exceeding 0.25 sqm & 16 to 18 mm thick, fixed with and including, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall beincluded in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall beincluded in the quoted rate.)
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall beincluded in the quoted rate.)
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and indicator and fuse complete all as specified and as directed.
S & F LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2150, lumen efficacy of minimum 105 lumens per watt, lamp base of G 13 bi pin, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, CRI greater than 80%, THD below or less than 10%, CW available CCT of 6500K, power factor of minimum 0.95, polycarbonate housing, life span of minimum 50000 working hours as per catalogue No. PHOTONULTRA+1213T8SSTL20WLED865SPC of Havells or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
Supply and fix Heavy duty Exhaust fans 300 mm sweep complete with motor & blades and all required accessories for fixing/hanging Make - Havells Cat Pt No/Model TurboFORCE SP or Equivalent in CG/ORIENT complete all as specified and as directed.
Supply, Installation, testing and commissioning of 36 W LED Street light fittings complete with all accessories with GI street light bracket, including connections with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable and earthing complete all as specified and as directed. Philips Model No. BRP409 LED CW 034 MR PC S1 PSU GR or equivalent of Crompton Graves or Bajaj.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cablfCe perpendicular to the direction of cable all as directed.
Supplying & fixing 50 mm nominal bore, light grade, galvanised coated steel tube laid in trenches, fixed to wall for cable protection complete all as specified and as directed.
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine including insertion of HDPE pipe of 150 mm dia complete all as specified and as directed. Note : HDPE pipe shall be measured and paid separately.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
M & L for construction of new valve chamber of size 1050 mm X 1050 mm X 950 mm including necessary earth work in any type of soil, PPC foundation (1:3:6) type C-2 40 mm grade stone aggregate as in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40 mm X 40 mm X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide prime on all metal works & three coats of white wash on all plastered surfaces of valve chambers complete all as specified & directed by Engineer-in-Charge.
M&L for cutting and drilling and fabrication of the existing CI/DI/GI pipe up to 100 mm dia including necessary fittings complete all as pecified and as directed.
SRI BHOOMIJ INFRAPROJECTS & SERVICES LLP
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .