Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹45.6 L+₹5.0 L (12.4%)Rejected-Finance 240 1 A RAI COLONY CIVIL LINES JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not being a
lowest
tenderer | |
| 3 | L3₹46.7 L+₹6.1 L (15.1%)Rejected-Finance | L3 | Rejected-Finance Not being a
lowest
tenderer |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE BABINA
GE BABINA CANTT 284401
COMPREHENSIVE REPAIR AND MAINT OF WATER SUP CHEMICAL TREATING SYSTEM WATER PUMPING AND DISTRIBUTION EQUIPMENTS, OF WATER SUPPLY UNDER GE BABINA CANTT
2022_MES_531667_1
GE/BAB/TOKEN/12 OF 2022-2023
Open Tender
Civil Works - Water Works
Item Rate
184 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹86,000
Yes
27 Jul 2022
17 Jun 2022
21 Jul 2022
17 Jun 2022
19 Jul 2022
1 Jul 2022
Amount
M & L for opening up short circuited / winding burnt electric induction motors of 5 to 7.5 HP capacity 3 phase AC 440 Volts, cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of same gauge and size suitable as per the existing including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified. Note - (i) Intimation for any unserviceable motor of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 1000/- per day for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. (iv) Quantity of retrieved copper from rewinding of item shall be calculated as per standrad norms
All as per item No. 1 here in before but induction motor of 10 to 12.50 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 15 to 30 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 40 HP 50 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 60 HP to 75 HP capacity 3 phase AC 440 Volts, complete all as specified.
All as per item No. 1 here in before but induction motor of 90 HP to 100 HP capacity 3 phase AC 440 Volts, complete all as specified.
S & F terminal connector of 5 to 30 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
S & F terminal connector of 40 to 100 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
S & F of PVC fan blade for motors of 5 to 15 HP capacity complete all as specified.
S & F MS pump motor coupling of 15 HP to 30 HP as per the existing size and shape for pump sets
S & F MS pump motor coupling of 40 HP to 100 HP as per the existing size and shape for pump sets
M & L for motor end ball / roller bearing with good quality grease suitable for 5 HP to 15HP capacity pump sets
M & L for motor end ball / roller bearing with good quality grease suitable for 15 to 40 HP capacity pump sets
M & L for motor end ball / roller bearing with good quality grease suitable for 60 to 100 HP capacity pump sets
S & F rubber bush/belt coupling (set of 8) for motor 15 to 30HP complete all as specified and directed.
S & F rubber bush/belt coupling (set of 8) for motor 40 HP to 60HP complete all as specified and directed.
S & F rubber bush/belt coupling (set of 8) for motor 90 to 100 HP complete all as specified and directed.
M & L for dismantling and taking up/down u/s centrifugal pump sets of any capacity of any size from foundations/pumphouse after disconnecting electric & water connections and transportation from site to contractor's workshop for carrying out repairs to pump sets , replacement of unserviceable parts as required incl re-assembling, re-fixing in position, including connecting in original position & testing complete as directed and specified . Note - (i) Spares required to be replaced will be measured and paid separately. (ii) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor or pump will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 1000/- per day for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted.
Supply and fix coupling key any size as per sample for pumping sets of different capacities complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 5 HP to 12.50 HP capacity complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 15 to 30 HP capacity complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 40 HP to 60 HP capacity complete all as directed and specified
M&L for carrying out replacement of u/s shaft suitable for centrifugal pump 90 to 100 HP capacitycomplete all as directed and specified
M & L for carrying out replacement of pump impeller of 5 HP to 7.5 HP capacity complete all as directed and specified
M & L for carrying out replacement of pump impeller of 10 HP to 30 HP capacity complete all as directed and specified
S & F in replacement of gun metal bush complete set of two as per sample for centrifugal pump set 15 HP to 30 HP complete all as directed and specified
S & F in replacement of gun metal bush complete set of two as per sample for centrifugal pump set 40 HP of 100 HP complete all as directed and specified
S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 15 HP to 30 HP complete all as directed and specified
S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 40 HP to 60 HP complete all as directed and specified
S & F in replacement of gun metal sleeve set of two Nos suitable for pump sets 90 HP 100 HP complete all as directed and specified
S & F in replacement of pump end ball bearing suitable for 15 HP To 30 HP complete all as directed and specified
S & F in replacement of pump end ball bearing suitable for 40 HP to 60 HP complete all as directed and specified
S & F in replacement of pump end ball bearing suitable for pump sets 100 HP. complete all as directed and specified
S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 15 HP to 30 HP capacity complete all as directed and specified
S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 40 HP to 60 HP capacity complete all as directed and specified
S & F GM neck rings (set of 2) as per sample suitable for centrifugal pump set 100 HP capacity complete all as directed and specified
S & F in replacement of impeller intermediate gun metal collar valve guide same as per sample for double acting impeller 100 HP pump set complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 15 HP capacity. complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 30 HP capacity complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 40 HP capacity.complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 60 HP capacity complete all as directed and specified
S & F in replacement gun metal impeller single acting suitable for 100 HP capacity complete all as directed and specified
M&L for taking out defective submersible pumping set of discharge capacity varying from 4000 to 12000 GPH from bore wells / shallow wells including dismantling and taking out column pipes of any bore & length alongwith submersible cable, steel wire rope etc; and re-lowering the pump set after carrying out necessary repairs / replacement of defective parts all as specified and directed. Note :- i) Costs of all necessary T&P and manpower required at site and transportation is deemed to be included in the rates quoted.
M&L for carrying out repair to submersible pump of 4000 to 12000 GPH capacity after dismantling the assembly for replacement of worn out spares such as stage bowls, impellers, pump shaft, sleeves, bushes etc; incl filling, turning & polishing works to pump shaft, GM impellers as necessiated, reassembling the pump after repairs and testing complete incl applying a coat of water proof epoxy paint to the external surfaces of pump all as specified and directed. (ii) Intimation for any unserviceable pump will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable pumps will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @Rs. 1000/- per day for delay period hour will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted.
S & F GM impellers with key and bushes suitable for 4000 to 12000 GPH capacity
S & F pump shaft stainless steel suitable for 4000 to 12000 GPH capacity
S & F non return valve for pump suitable for 4000 to 12000 GPH capacity
S & F bush for pump set suitable for 4000 to 12000 GPH capacity
S & F bowl assembly complete with stage bolts suitable for 8000 to 12000 GPH capacity
S & F neck rings for pump sets of any capacity
S & F stage bowl bush GM suitable for pump sets of any capacity
S & F distance sleeve suitable for pump sets of any capacity
M&L for water proof cable jointing kit with hardner compound, copper ferrule, sleeves, cotton / insulation tape and all materials complete suitable for submersible cable PVC insulated and sheathed, 6 to 10 sqmm flat, 3 core, 1100 volt grade complete all as specified and directed.
M&L for rubber gasket packing, 4 mm thick suitable for 50/80/100 mm dia flanged column pipes complete all as specified.
M & L for rewinding of submersible motors AC, 3 phase, 440 volt 4 to 15 HP with superior quality PVC insulated copper winding wire of identical gauge & specification of the existing short circuited winding wires with all necessary insulating materials incl cleaning of stator & slots and applying one coat of water proof epoxy paint to the exteriors of motor and testing complete all as specified on load of capacity. Note :- Any spares other than specified in the item will be measured and paid separately. (ii) Intimation for any unserviceable pump of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable motor will have to be repaired , re-installed in and made functional without anyt defect within a period of 96 hrs after intimation to contractor failing which a panel recovery @ Rs. 1000/- per day for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc . Contractor have to quote his rates accordingly and no claim whatsoever shall be entertained in this regard . (iii) Costs of all necessary T&P required at site and transportation is deemed to be included in the rates quoted. (iv) Quantity of retrieved copper from rewinding of item shall be calculated as per standrad norms
M&L for repairs to rotor assembly of submersible motor of any size/make incl cutting & cleaning of defective copper strips from rotor slots, filling cavities, gas welding/bracing and finishing complete all as specified.
S & F motor bush upper and lower 4 to 15 HP for submersible motor complete all as specified.
S & F rotor bearing sleeve upper and lower suitable for submersible motor of any size/capacity complete all as specified.
S & F sand guard suitable for submersible pump set any size/capacity complete all as specified.
S & F motor thrust bearing assembly complete suitable for 4 to 15 HP complete all as specified.
S & F motor housing upper suitable for 4 to 15 HP complete all as specified.
S & F motor housing lower suitable for 5 to 15 HP complete all as specified.
S & F motor coupler sleeve with key suitable for submersible pump sets of any capacity.
S & F in eplacement of DOL starter suitable for 5 HP to 7.5 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 5-10A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified.
S & F in replacement of FASD starter in sheet metal enclosure suitable for 10 HP to 15 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 13-21 A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified.
S & F in replacement of FASD starter in sheet metal enclosure suitable for 20 HP to 30 HP induction motor, 3 phase 440 volt complete with over load protection & adjustable relay range 20-32 A, incl provision of mounting arrangement with MS flat strips 40 mm x 5 mm thick of suitable length and shape duly drilled and embedded to wall incl making good disturbed surfaces incl dismantling complete all as specified.
S & F in replacement of cast iron sluice valve of 80 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost. Note:- Contractor will be intimated to replace the deffective sluice valve on telephonically followed by in written. Contractor has to arrange new sluice valves and complete the replacement work with 96 hrs after intimation failing which a penal recovery of Rs 1000/- per day will be charged from his payment. Contractor has to keep all required size sluice valve and T&P with manpower ready for fixing on urgent requirment and quote his rates accordingly.
All as per Srl item No. 67 here-in-before but 100 mm dia bore
All as per Srl item No. 67 here-in-before but 150 mm dia bore
All as per Srl item No. 67 here-in-before but 200 mm dia bore
All as per Srl item No. 67 here-in-before but 250 mm dia bore
All as per Srl item No. 67 here-in-before but 300 mm dia bore
S & F in replacement of gun metal gate valves of size 15 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/S gate valves all as specified and directed
Discription as per item No 73 here in before but 20 mm bore
Discription as per item No 73 here in before but 25 mm bore
Discription as per item No 73 here in before but 40 mm bore
Discription as per item No 73 here in before but 50 mm bore
Supply only Nylon braided PVC flexible pipe, heavy duty 20 mm dia.all as per sample
Supply only Chlorine test kit with coloured sample complete with all testing fitments and 100 ml OT solution in rexine finish wooden box all as per sample.
Supply only Ortho tholodine solution in 500 ml bottle.
Supply only Crystal Alum (Ferric)
Supply only Copper Sulphate
S&F in replacement PVC flexible corrugated pipe of size 50mm bore for suction sweeper as per sample complete all as directed and specified.
S & F in replacement of motor starter of capacity upto 100 to 150 HP motor, 3 phase 415 volt with comprehensive motor protection, programmable over load protection, built-in RTD & Thermistor inputs with constant current adaptive accelaration & de-accelaration for smooth start and stop operation of motor incl dismantling of u/s starter & installation / programming by skilled technician of original manufacturer, incl necessary mounting arrangement on existing panel such as fastener nuts & bolts and also fixing HRC fuse of suitable capacity onpanels with copper busbars etc as required complete all as specified and directed.
Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed. Note :-The contractor must submit the COC (Certificate of Compliance) in original from manufacturer by All India Authorised MES Distributor for each batch of product delivered indicating and including Chemical Analysis Report by All India Authorised MES Distributor. Make shall be approved by the Accepting officer based on creteria mentioned in PS clause 28 on the approved list of E-in-C's Branch. Note :- 1. The contractor must submit the COC (Certificate of Compliance) in original from manufacturer for each batch of product delivered including chemical analysis report. Contractor has to get approval of Accepting officer before placing purchase order .
S & F cast iron foot valves with flanged end in replacement 80 mm bore all as per including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed. Make:-Kirloskar/leader/upadhayay/sant Note:- Contractor will be intimated to replace the deffective foot vavle on telephonically followed by in written. Contractor has to arrange new foot valves and complete the replacement work with 96 hrs after intimation failing which a penal recovery of Rs 1000/- per day will be charged from his payment. Contractor has to keep all required size foot valve and T&P with manpower ready for fixing on urgent requirment and quote his rates accordingly.
All as per item No 86 here in before but foot valves with flanged end in replacement 100 mm bore all l as directed and specified .
All as per item No 86 here in before but foot valves with flanged end in replacement 150 mm bore all l as directed and specified .
All as per item No 86 here in before but foot valves with flanged end in replacement 200 mm bore all as directed and specified .
S & F in replacement of MCCB, 4 Pole, 630Amps 415 Volt AC, 50 Hz, rupturing capacity 50 KA with adjustable thermal and fixed magnetic tripping systems against over load and short circuit conditions conforming to IS:13947 (Part-2) Ics = 100%ICU all as directed and specified .
All as per item No 90 here in before but MCCB of capacity 400 Amps 35 KA all l as directed and specified .
All as per item No 90 here in before but MCCB of capacity 250 Amps 35 KA all l as directed and specified .
All as per item No 90 here in before but MCCB of capacity 200 Amps 25 KA all l as directed and specified .
All as per item No 90 here in before but MCCB of capacity 125 Amps 25 KAall l as directed and specified .
All as per item No 90 here in before but MCCB of capacity 100 Amps 16 KA all l as directed and specified .
M & L for submersible cable, flat PVC insulated and sheathed, 3 core, 6 sqmm, multistranded copper conductor, 1100 volt grade, conforming IS-694, heavy duty complete all as specified and directed.
All as per item 96 but cable of size 3 core, 10 sqmm, multistranded copper conductor, 1100 volt grade, heavy duty.
M&L for MS Fabrication work, made out of structural steel sections as in frame work for cable & piping ducts / MS door panels etc at water supply installations, MS angles / flats / plain sheets of appropriate gauge, cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shape or sizes as required including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
M&L for repairs to FASD starter, AC 3 Phase, 440 V of 10 HP to 15HP capacity of any make incl replacement of all u/s spares, integral wiring with appropriate gauge, copper conductor cables, copper lugs, terminal block with brass bolts, nuts & washers etc all as specified. Note :- 1. Spares to be replaced will be measured and paid seperately as supply only. 2. Cost of labour and copper lugs, terminal block with brass bolts, nuts & washers included in the quoted rate.
S & F contactor repair kit without coil suitable for 10 HP to 15 HP.
S & F power contactors of upto 40 amps 415 volts suitable for 10 HP to 15 HP.
S & F over load protection relay of suitable range suitable for 10 HP to 15 HP.
S & F electronic timer device 0-20 second delay suitable for 10 HP to 15 HP.
M & L for opening of soft starter EMX 3 series of L&T make 40-100 HP capacity from the existing panel (by a skilled representative of original manufacturer) for servicing, repair, replacement, refixing of spares like control card (EMX3 Series), display, supply card, contactor, CT, fuses etc, tightening of loosen integral wiring, copper lugs, terminal blocks, nut and bolts, washers etc complete all as specified and directed by Engr-in-Charge. Note :- 1. The Manufacturers Rep or authorised service dealer representative/technician will be arrenged by contractor and necessary documents/ proof of technician will be produced to Eng-in-Charge before starting repair work. 2. spares to be replaced will be measured and paid seperately as supply only. 3. Cleaning of dust and other materials to be carried out only using of CRC 2-26. 4. Cost of skilled representative, tools, wiring, copper lugs, terminal blocks, nuts and bolts, cleaning materials, etc required at site included in the quoted rates. 5. If any damage occured in the spares during repair the same will be replaced by the contractorat at his own cost.
S & F in replacement control card of soft starter of suitable for 40 HP capacity complete all as directed and specified .
S & F control card of soft starter of suitable for 60 HP capacity. complete all as directed and specified .
S & F control card of soft starter of suitable for 100 HP capacity. complete all as directed and specified .
Supply only suitable CT for soft starter of 100 HP capacity complete all as directed and specified .
Supply only bolted type HRC fuse links of capacity 125 Amps to 250 Amps , 415 volts 80 KA Make - L&T/Havells/C&S/BCH complete all as directed and specified .
All as per item No 109 here in before but of capacity 315 amps to 600 Amps complete all as directed and specified .
Supply and laying in replacement under ground cable XLPE insulated PVC sheathed multistranded aluminium conductor cable armoured of size 16 sqmm 4 core 1100 volt grade in trenches/floors or on poles complete all as specified.
All as per item No 111 here in before but cable armoured of size 25 sqmm 4 core 1100 volt grade
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in any type of soil (soft/loose/hard/dense soil) for laying / taking up / taking down of cables or taking down/erecting poles and getting out and levelling of bottom surface to required level all as specified and directed .
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified in the any type of soils
Removal excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified.
Supplying and laying precast concrete cable cover class LV type -I flat size 250x150x40 mm laid parpendicular to the axis of cable in trenches etc complete as directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:4) as in foundation of equipment, platform, ramp, supporting pillars of pipes, protection wall of UG sump incl demolition of existing brick work built in cement mortar complete all as specified and directed.
M&L for 100mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foot path etc complete all as specified and directed
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level including removal of debris complete all as specified and directed
M&L for plastering in CM (1:4) 10 mm thick on fair faces of brick work or concrete surface/ cable duct / floor including demolition complete all as specified and directed.
S & F in replacement of galvanised steel water tubing medium grade 15 mm bore ISI marked with all fittings such as bends, elbow, socket etc laid under floors/trenches or on walls with fixing arrangments including leakage testing etc complete all as specified and directed.
Description all as per item No 122 here in before but of size 20 mm bore
Description all as per item No 122 here in before but of size 25 mm bore
Description all as per item No 122 here in before but of size 32 mm bore
Description as per item No 122 here in before but of size 50 mm bore
Description as per item No 122 here in before but of size 80 mm bore
Description as per item No 122 here in before but of size 100 mm bore
M&L for dismentling and taking out GI water pipes with fittings and connections from wall/roof/floor or trench of size 15 mm dia including cleaning for refixing /relaying or rerouting of serviceable length complete all as specified and directed. Note:- (i) Necessary excavation refilling removing of soil shall be measured & paid separatly under relevant items. (ii) Relaying/rerouting of serviceable length of pipe will be measured and paid under seperate items here under .
Discription all as per item No 129 here in before but of size 20 mm bore
Discription all as per item No 129 here in before but of size 25 mm bore
Discription all as per item No 129 here in before but of size 40 mm bore
Discription all as per item No 129 here in before but of size 50 mm bore
Discription all as per item No 129 here in before but of size 80 mm bore
Discription all as per item No 129 here in before but of size 100 mm bore
M & L for cutting and removing unwanted grass, wild growth incl bushes and shrubs from the roots below ground level at various over head tanks premises about 15 mtr radious with approaching road and removing boulders from a depth not more than 25 cms below normal ground level and depositing where directed and levelling / pruning the entire cleaned area to even finish complete all as specified and directed at site.
S&F and testing PVC insulated and unsheathed, multistranded copper conductor single core, 50 sqmm, 1100 volt grade confirming to IS-694 in replacement for connection from LT Panel board to motor starters and starters to electric motor incl necessary cable end termination with copper lugs of suitable size drawn through 32 mm dia non metallic rigid PVC conduit incl all fittings such as bends, sockets etc laid under the floors or fixed to wall with suitable mild steel clamps of FI 40x5 mm etc complete all as specified and directed.
S&F and testing PVC insulated and unsheathed, multistranded copper conductor single core, 25 sqmm, 1100 volt grade confirming to IS-694 in replacement for connection from LT Panel board to motor starters and starters to electric motor incl necessary cable end termination with copper lugs of suitable size drawn through 32 mm dia non metallic rigid PVC conduit incl all fittings such as bends, sockets etc laid under the floors or fixed to wall with suitable mild steel clamps of FI 40x5 mm etc complete all as specified and directed.
M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc) all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
S & F chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc.
S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia.
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed.
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed. Note - Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.
Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT PANEL , indoor type floor mounted , 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet , duly powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside fixed on angle iron frame work of 50x50x5mm thick duly supported with angle iron of size 50x50x6 mm thick , fixed on base of size suitable for to errect panel , casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregates total 750 mm thick 450 mm above GL and 300 mm thick below GL, , panel shall be front opening double door and rear opening type with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the followings: - (a) Aluminium bus bar4 strips , 150 Amps current rating with post insulator and heat shrnkable sleeves Incoming:- (b) MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA , 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) Outgoing:- (c) MCCB 4 pole 63 Amp with ultimate breaking capacity Icu -25 kA ,415 Volts adjustable type with thermal and magenetic settings confirming to 60947 part-I /IS -13947 -02 Nos, (d) Aluminium bus bar4 strips , 100 Amps current rating duly insulated ,wired & duly mounted on porcelain insulator (e) Multifunction digital meter CT operated showing voltage ,current ,Hz, KW ,KWH (f) Cosmic star fully autometic star delta ( ASD) starter suitable for 12.5 to 15 HP motor including overload relay ,single phase Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's. Note :- Panel drawings will be submitted by contractor for approval from Accepting Officer before ordering the panel .
M/s BRIJ KUMAR RAI
m/s gupta trading
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .