Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.3 CrAccepted-Finance | ₹61.3 Cr | L1 | Accepted-Finance Lowest rate found. |
| 2 | L2₹63.9 CrAccepted-Finance | ₹63.9 Cr | L2 | Accepted-Finance Highest rate found. |
Tender Value
₹51.1 Cr
EMD Value
₹61.1 L
Closing Date
9 Nov 2022, 2:00 pmClosed
The Exe.,Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
PROVIDING, LOWERING AND LAYING OF NETWORKING OF DMC AREA OF N. D. U.G. SEWERAGE SYSTEM EXCUDING THE WORK OF WARD NO. 03,04(PART) AND 15 OF M. A. OF N. D. INCLUDING 10 MLD STP WITH O AND M OF THE ENTIRE PROPOSED SEWAGE STSTEM FOR 5 YEARS.(2nd call)
2022_DAMAN_2449_1
Tender Notice No.70/01/2022-23
Open Tender
Civil Works - Others
730 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Exe.,Engg., PWD, WD-I, Daman.
₹61.1 L
The Exe.,Engg., PWD, WD-I, Daman.
29 Dec 2022
20 Oct 2022
9 Nov 2022
20 Oct 2022
9 Nov 2022
20 Oct 2022
1 Nov 2022
Amount
Civil work
Excavation for pipe line trenches for water supply sewerage line machinehole etc. all with shoring and struting if required as per required gradient and line includign safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified . In hard murrum, boulders incl. macadam road.
Excavation in bituuminous road as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Excavation in Bituminous road
Excavation for pipe line trenches for water supply sewerage line machinehole etc. all with shoring and struting if required as per required gradient and line includign safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. In C.C. Road
Dewatering by pumping set of required capacity including temporary platform carting pumping at site and fixing the same in position including all accessories, and fuel and labour etc. complete.Pump set of Capacity
Providing and supplying ISI Standard R.C.C. pipes (of Sulphate Resisting Cement) in standard lengths of following class and diameter suitable for rubber ring joints including Including 3 mm HDPE Liner with all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. (E1) 300 mm dia (NP3 Class)
(E2) 300 mm dia (NP4 Class)
(F1) 350 mm dia (NP3 Class)
(F2) 350 mm dia (NP4 Class)
(G1) 400 mm dia (NP3 Class)
(G2) 400 mm dia (NP4 Class)
(H1) 450 mm dia (NP3 Class)
(H2) 450 mm dia (NP4 Class)
(I1) 500 mm dia (NP3 Class)
(I2) 500 mm dia (NP4 Class)
(J1) 600 mm dia (NP3 Class)
(J2) 600 mm dia (NP4 Class)
(K1) 700 mm dia (NP3 Class)
(K2) 700 mm dia (NP4 Class)
(L1) 800 mm dia (NP3 Class)
(L2) 800 mm dia (NP4 Class)
(M1) 900 mm dia (NP3 Class)
(M2) 900 mm dia (NP4 Class)
(N1) 1000 mm dia (NP3 Class)
(N2) 1000 mm dia (NP4 Class)
(O1) 1200 mm dia (NP3 Class)
(O2) 1200 mm dia (NP4 Class)
Lowering, laying and jointing R. C. C. pipes in C. M. 1:1 1/2 of following diameters in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, labour, giving hydraulic testing as per ISI code..(E1) 300 mm dia (NP3 Class)
(E2) 300 mm dia (NP4 Class)
(F1) 350 mm dia (NP3 Class)
(F2) 350 mm dia (NP4 Class)
(G1) 400 mm dia (NP3 Class)
(G2) 400 mm dia (NP4 Class)
(H1) 450 mm dia (NP3 Class)
(H2) 450 mm dia (NP4 Class)
(I1) 500 mm dia (NP3 Class)
(I2) 500 mm dia (NP4 Class)
(J1) 600 mm dia (NP3 Class)
(J2) 600 mm dia (NP4 Class)
(K1) 700 mm dia (NP3 Class)
(K2) 700 mm dia (NP4 Class)
(L1) 800 mm dia (NP3 Class)
(L2) 800 mm dia (NP4 Class)
(M1) 900 mm dia (NP3 Class)
(M2) 900 mm dia (NP4 Class)
(N1) 1000 mm dia (NP3 Class)
(N2) 1000 mm dia (NP4 Class)
(O1) 1200 mm dia (NP3 Class)
(O2) 1200 mm dia (NP4 Class)
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost of reinforcement M.S. Angles or Flate, curring mold work etc. 1. Heavy duty. > Frame
> Cover
Puchasing, transporting, unloading, eretion RCC Sewer machineholes using RCC M40 and steel reinforcement of TMT FE-500 for following different sections for sizes of PVC steps at site as per required depth including all materials and taxes etc. complete (Excluding Machinhole Cover)Conical Chamber Section (Height 1300 mm) as per Drawing & Design with 300mm C/C PVC Steps (300mm Wide) (PVC Steps 4 Nos.)
Base section with bottom (height 1500mm as per drawing & design with predefined opening for RCC pipe and 300mm c/c PVC steps (300mm wide)
Frame 560mm dia (175mm height)
Riser Section 150 mm height (PVC Step 1 nos.)
300 mm height (PVC Step 1 nos.)
600 mm height (PVC Step 2 nos.)
900 mm height (PVC Step 3 nos.)
Providing and constructing Sewer manholes, scraper manholes and unit house connection chamber, as per the type design in brick masonary in C. M. 1:3 and outsice plastering in C. M. 1:3 necessary coping in R.C.C.M. 200 fixing C. I. steps and fixing manhole frame and covers (But excluding supply of manhole frame and covers) over manholes and house connection chambers and fixing Manhole covers (but excluding supplying of manhole covers) over scraper manhole etc. complete, providing and fixing safety chain wherever necessary as per the stipulations in the type desing complete (excl. excavation). 1. Manhole type 'A' - Circular, having inside diameter of 1200mm for depth upto 1.5m (150 to 500mm dia. sewers). > Upto 1 m depth
> Beyond 1.00m and upto 1.50m depth
2. Manhole type 'B' - Circular, having inside diameter of 1500mm for depth upto 1.50 to 4.00m (150 to 600mm dia. sewers). > Upto 1.50m depth
> Beyond 1.50m and upto 4.00m depth
3. Manhole type 'C' - Circular, having inside diameter of 1500mm for depth upto 4.00 to 6.00m (150 to 1800mm dia. sewers). > Upto 4.00m depth
> Beyond 4.00m and upto 6.00m depth
4. Manhole type "D1" circular type having inside diameter of minimum 1500 mm and for depth beyond 6 m to 10 m (for 150 mm to 500 mm diameter sewers)> Upto 6.00m depth
> Beyond 6.00m and upto 10.00m depth
5.Manhole type "D2" circular type having inside diameter of minimum 1500 mm and for depth beyond 6.0 M to 10.0 M (for 600 mm to 1000 mm dia sewers)> Upto 6.00m depth
> Beyond 6.00m and upto 10.00m depth
5.Manhole type "D3" circular type having inside diameter of minimum 1900 m and for depth beyond 6.0 m to 10.0 m (for 1100 mm to> Upto 6.00m depth
> Beyond 6.00m and upto 10.00m depth
5. Scraper manhole type "SI" rectangular type for 150 mm dia to 1200 mm dia sewer pipes and for depth 2.5 m to 9.0 m. Scraper manhole type "SI" as above but upto 2.5 m depth.
Extra depth beyond 2.5 m and upto 9.0 m depth for type "SI" scraper manhole above.
Providing and erecting C. I. and MS ventilating columns 15 cms. dia. with C.I. ornamental cap and Min 6.00 Mtr. Height (Height may be varying as per site) base fixed firmly with necessary foundation with one coat of red lead oxide paint and one coat of any approved colour with 15 cms, dia.10 Mt.in length with 0.35mt*0.35mt* M100 Encasing, stoneware or R.C.C. pipe connection with M.H. including excavation and jointing as required etc. complete. as per drawing.
Excavation for pipe line trenches for water supply , sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including saftey provisional using site rails and stacking excavated stuff including upto all required lead cleaning the site etc. complete for all lifts and strata as per specified. # 0.00 to 1.50m In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 1.50 to 3.00m In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 3.00 to 4.50m A. In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 4.50 to 6.00m A. In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 6.0to7.5 m A. In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
Excavation for circular manhole (well) including removing and spreading the excavated stuff as directed within lead upto 90.00m. # 0.00 to 1.50m. In all sorts of Soil and Soft murrum
B. In Hard Murrum
# 1.50 to 3.00m In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 3.00 to 4.50m In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 4.50 to 6.00m In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
# 6.0 to7.5 m In all sorts of Soil and Soft murrum
B. In Hard Murrum
C. In Soft Rock
D. In Hard Rock
Refilling the pipe line trenches incl. ramming, watering, consolidating disposal of surplus stuff as directed within a radius of 3 km.
Box cutting the road surface to proper slop and camber for raod work, lime flyash stabilization with lime @ 10kg/sqmtr.+ flyash@50kg/sqmtr. And mixing with disc harrowing, Granular Sub Base (drainage layer) conforming to grading V of Table 400-1 of compacted thickness of 150 mmrolling and compactiion of subgrade, Wet Mix Macadam with paver finisher in specified thickness, each layer not exceeding 150 mm compacted thickness including premixing in WMM plant, Prime coat SS-I bitumen emulsion @ 0.85kg per sq.mtr. & RS-I bitumen imulsion @ 0.27kg per sq.mtr.,Tack Coat RS-0.25 Kg per sq.m. DENSE GRADED BITUMINOUS MACADAM as per gradation and bitumen for mixing shall be as arrived from mix design, provided in no case it shall be less than 4.0% by wt.,using aggregates as per gradation and percentage of bitumen for mixing shall be as arrived from mix design, spreading ston dust, preparing suraface and scarifying the surface.
Providing interlocking type rubber moulded cement cocrete paver block of approved shape, design and colour having 80mm thickness M30 purchased from approved paver block manufracturer only of fine sand bedding. Item includes levelling by using vibratory plates compacted machine. Item also includes all materials, labour, equipments, tools, plants, watering and cleaning etc. complete. (with colour)
Providing & laying Dry Lean Concrete sub base including providing coarse and ine aggregate to the specified gradation using minimum cement content 150kg/cum of concrete with OPC 43 grade cement, mixing of concrete as per approved design mix using mechanized batch mix plant of appropriate capacity, transporting and laying with self propelled paver with electronic sensor device and compacting with vibrating roller of minimum 80-100KN static weight to give desired compaced density and average compressive strength of 10MPa at 7days and curing with liquid cuing compound and sprinkling water and covering with moist hessian or ponding of water for 7days including providing construction joints, incuding all material, labur, machinery with all ledas and lifts etc. complete
Providing and laying Pavement Quality Concrete of M35 grade including providing 125micron thick impermeable plastic sheet membrane ovwewr the surface to be covered, coarse and fine aggregates of specified gradation OPC 43 grade cement, approved admixture and adding Recron 3S or equivalent fibers @ 0.25% by weight of cementations material mixed and supplied by standard RMC plant or in fully automatic concrete batching plant of appropriate capacity and with comnputerized controls as per the design mix to the the specified workability, transpirting the mix with dumpers or transit mixers and laying with channel section of required thickness byfix form/manually with all vibratory equipments, curig with approved resin based aluminized reflective curing comound and covering with moist hessian and ponding and sprinkling of water for a minimum period of 14days and including, aproved liquid seals of either polysulphide/olyrethene for joint filling and sealing all types of joints and finishing to the desired surface texture including all material, labour, machinery, formwork with all leads and lifts etc. complete
Providing and laying Granular Sub Base (drainage layer) conforming to Grading II of Table 400.2 of compacted thickness of 150mm with specification graded stone metal and sand mixed in pugmill and laid with mechanical means spreading with motor grader and compacting with vibratory roller having minimum 80-100KN static weight to achieve desired density of 98% o MDD including all material, labour, machinery with all leads and lifts ec. complete
Excavation for pipe line trenches for water supply , sewerage line, manhole etc. all with shoring and struting if required as per required gradient and line including saftey provisional using site rails and stacking excavated stuff including upto all required lead cleaning the site etc. complete for all lifts and strata as per specified. # 0.00 to 1.50m In all sorts of Soil and Soft murrum
# 0.0 to 1.50m In all sorts of Soil and Soft murrum for house connection pipeline
Providing and constructing rectangular brick masonry chamber for house connection as per type design in brick masonry in C.M. 1:3 including M-100 in foundation M-150 in benching inside plastering in C.M. 1:3 and plastering in C.M. 1:3 coping in M200, RCC precast or C.I. manhole frame and cover but excluding supply of manhole frame and cover etc. complete,(Excluding excavation)
Providing and supplying ISI standard Stone-ware Class-A. pipes in standard lengths of 100 mm diaincluding all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS- 651/1989) 100 mm dia
150 mm dia
Lowering, laying and jointing Stone Ware pipes of following diameters with cement joints in C. M. 1:1 proportion in proper position, grade and alignment at all level as directed by Engineer-in-charge including conveyance from stores to site of work, Jointing material etc. comp. 100 mm dia
150 mm dia
RCC precast M.H. Frame and cover manufacture, supply and delivery at store or site of work precast RCC M.200 frame & Cover suitable to drainage M.H. and as per type design & drawing including cost of reinforcement M.S. Angle or Flate, curring mold work etc. complete. light duty, Frame
Cover
Refilling of pipe trenches including ramming, watering, consolidating, disposal of surplus stuff as directed within a radius of 3.0 km.
Sewage Pumping Station: Design, supply, construction, of sewage pumping station including Boring for water supply, toilet block, internal roads and other ancilliary work (for Sewage Pumping Station, details are given in Volume II Extent of work) 0.5 to 3 MLD
3 to 6 MLD
6 to 15 MLD
ITEM NO. 1Excavation for foundation including sorting out and stacking off useful materials and disposing of the excavated stuff up to 20 mt. lead and all lift, watering etc. comp. Loose or soft soil (A) upto 1.5mt depth
(B) 1.5 to 3.0 mt depth
ITEM NO. 2 Empty boring through all. sorts of strata for providing 0.35 MTR. dia. R.C.C. bored piles to required depth including providing necessary casting pipe with all plants and equipments as required complete. ( I ) 300mm
ITEM NO. 2A Extra for under reaming inside the bore holes for under reamed piles of 300 mm diameter
ITEM NO. 3 Providing and laying cement concrete 1: 3: 6 (1 cement : 3 coarse sand :6 graded stone aggregates 40 mm nominal size) and curing complete including cost of formwork in: (A) Foundation and plinth
ITEM NO. 4 Providing and laying cement concrete work 1:11/2:3 (1 cement :11/2 coarse sand :3 graded stone aggregate 20 mm nominal size) and curing complete including cost of form work Up to excluding cost of reinforcement for reinforced concrete work in : (A) foundation, footing, base of columns and mass concrete
ITEM NO. 5 Providing and laying ordinary cement concrete 1:11/2:3 (1 cement :11/2 coarse sand :3 graded stone aggregate 20mm nominal size) and finishing smooth etc. complete including cost of form work but excluding the cost of reinforcement for R.C.C. work in: (A) Column
(B) Beam( up to 0.08 sqmtr.)
(0.08 to 0.012sqmtr. )
ITEM NO. 6 Providing and fixing TMT (FE-415) bar reinforcement for R.C.C. work including bending, binding and placing in position etc. comp. upto floor two level.
ITEM NO.7 Filling in trenches with available excavated soil incl. Watering and consolidating etc. comp inclu. Spreading the available soil as per instruction of engineer in charge etc. complete.
ITEM NO. 8 Providing and laying c.c. 1:3:6 ( 1 cement :3 coarse sand :6 crushed stone agg. 20 mm nominal size ) and Finishing smooth etc. complete including cost of form work in wall caps/Coping/Beam
ITEM NO.9 Providing and constructing brick work using fly ash building bricks having crushing strength not less than 70 kg/sqcm. in super structure in cement mortar 1:6 (1 cement :6 fine sand) etc. comp.up to G.L./P.L
ITEM NO.10 Providing and applying 20mm. thick sand faced cement plaster on wall similar surfaces at all floor levels consisting of 12mm av. Thk. Backing coat of C.M. 1:3 (1 cement : 3 sand ) & 8 mm tk. Finishing coat of C.M.1:1(1cement:1 sand)----Upto GL/PL Ground floor -For Wall
ITEM NO.11 Providing & Applying 15mm.th.cement plaster in single coat on brick/ concrete walls similar surfaces for plastering & finished even & smooth with a floating coat of cement slurry mixed with admixture of lime or neeru in required proportion etc. comp. in C.M 1:3 (1 cement : 3sand) (A) For wall and similar surfaces -- Ground Floor
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete
ITEM NO.13 Steel work welded in built up sections, framed work for M.S. gate including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.t:- (A) in beams & joists channels angles, tees, flats with connection plates or angle cleats as in main & cross beams, hip & trussed purloins connected to common refers & the like.
ITEM NO.14 Providing and fixing 'Y' shaped barbed wire fencing on compound wall top with verical angle of 50X50X6 mm X1.00mt height, two cross angles 50X50X6 mm X 0.60 mtr. Length, having 3 Horizontal and two diagonal rows of barbed wire on vertical angle and three horizontal and two diagonal barbed wire rows on each cross angles incl. cost of barbed wires, necessary GI stapplings, fixing in CC (1:2:4) blocks of 0.23X0.23X0.30 mtr. size on top of compound wall, painting angles with one coat of anticorrossive primer angles and
ITEM NO.15 Painting two coats (excluding priming coat) on new steel and other metal surface with synthetic enamel paint, brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matters.
ITEM NO. 1 Excavation for foundation including sorting out and stacking off useful materials and disposing of the excavated stuff up to 20 mt. lead and all lift, watering etc.comp. (A) upto 1.5mt depth
(B) 1.5 to 3.0 mt depth
ITEM NO.2 Empty boring through all. sorts of strata for providing 0.35 MTR. dia. R.C.C. bored piles to required depth including providing necessary casting pipe with all plants and equipments as required complete. ( I ) 300mm
ITEM NO.2A Extra for under reaming inside the bore holes for under reamed piles of 350 mm diameter (Rate of 300mm dia is 373 Rs./No.
ITEM NO. 3 Providing and laying cement concrete 1: 3: 6(1 cement : 3 coarse sand :6 graded stone aggregates 40 mm nominal size) and curing complete including cost of formwork in: (A) Foundation and plinth
ITEM NO. 4 Providing and laying cement concrete work M-30 and curing complete including cost of form work Up to excluding cost of reinforcement for reinforced concrete work in : (A) foundation, footing, base of columns and mass concrete
ITEM NO. 5 Providing and laying ordinary cement concrete M-30 and finishing smooth etc. complete including cost of form work but excluding the cost of reinforcement for R.C.C. work in: (A) Column
(B) Vertical wall
ITEM NO. 6 Providing and fixing TMT (FE-415) bar reinforcement for R.C.C. work including bending,binding and placing in position etc. comp. upto floor two level.
ITEM NO.7 Filling in trenches with available excavated soil incl. Watering and consolidating etc. comp inclu. Spreading the available soil as per instruction of engineer in charge etc.complete.
ITEM NO. 8 Providing and laying c.c. 1:3:6 ( 1 cement :3 coarse sand :6 crushed stone agg. 20 mm nominal size ) and Finishing smooth etc. complete including cost of form work in:wall caps/coping
ITEM NO. 9 Providing and constructing brick work using fly ash building bricks having crushing strength not less than 70 kg/sqcm. in super structure in cement mortar 1:6 (1 cement :6 fine sand) etc. comp. up to G.L./P.L
ITEM NO. 10 Providing and applying 20mm. thick snad faced cement plaster on wall similar surfaces at all floor levels consisting of 12mm av. Thk. Backing coat of C.M. 1:3 (1 cement : 3 sand ) & 8 mm tk. Finishing coat of C.M.1:1(1cement:1 sand)----Upto GL/PL Ground floor -For Wall
ITEM NO. 11 Providing & Applying 15mm.th.cement plaster in single coat on brick/ concrete walls similar surfaces for plastering & finished even & smooth with a floating coat of cement slurry mixed with admixture of lime or neeru in required proportion etc. comp. in C.M 1:3 (1 cement : 3sand) (A) For wall and similar surfaces -- Ground Floor
ITEM NO. 12 Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete(a)for wall
ITEM NO. 13 Steel work welded in built up sections, framed work for M.S. gate including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.t:- (A) in beams & joists channels angles, tees, flats with connection plates or angle cleats as in main & cross beams, hip & trussed purloins connected to common refers & the like.
ITEM NO. 14 Providing and fixing 'Y' shaped barbed wire fencing on compound wall top with verical angle of 50X50X6 mm X1.00mt height, two cross angles 50X50X6 mm X 0.60 mtr. Length, having 3 Horizontal and two diagonal rows of barbed wire on vertical angle and three horizontal and two diagonal barbed wire rows on each cross angles incl. cost of barbed wires, necessary GI stapplings, fixing in CC (1:2:4) blocks of 0.23X0.23X0.30 mtr. size on top of compound wall, painting angles with one coat of anticorrossive primer angles and
ITEM NO. 15 Painting two coats (excluding priming coat) on new steel and other metal surface with synthetic enamel paint, brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matters.
Supply, installation, testing & commissioning of sewage submersible, Non clog type suitable for working on Air filled Dry type motor, three phase, 50 Hz +/-3%, 415V +/- 10%, AC supply, with 3 core flat copper cable from pump to starter panel with cable end terminations. all supports, clamps, pipe fittings alongwith mechanical seal, bearing bush, strainer etc. complete set & following M.O.C: Casing CI, SS CF8M impeller, Bronze: wearing ring & Bearing bush, TC mechanical seal, CS/S.S.bearing, S.S shaft with sleeve, SS strainer & MS motor body. HP: 60 HP
Sluice Valve Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. 100 mm dia
150 mm dia
200 mm dia
250 mm dia
350 mm dia
600 mm dia
NON RETURN VALVE Providing and supplying ISI mark CI D/F Reflux Valves as per IS:5312 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. 100 mm dia
150 mm dia
200 mm dia
250 mm dia
350 mm dia
600 mm dia
Lowering, laying and jointing C. I. / D/F Reflux valves, Sluice valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 100 mm
150 mm dia
200 mm dia
250 mm dia
350 mm dia
600 mm dia
Expansion Bellows Supply, installation, testing & commissioning of flange ends Expansion Bellow as per EJMA standards of overall length of minimum 300 mm, designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC & pressure ratings. MOC: Bellows: SA 240 Gr. 304; Internal Sleeve: SA 240 Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS 2062 Gr. B (Drilling as per IS 1538 / IS 6392 ) & Limit Rods & Nuts: CS - IS 1367. 100 mm dia
150 mm dia
200 mm dia
250 mm dia
350 mm dia
600 mm dia
Air valves with Isolating Sluice Valve Providing and supply C.I. Temper proof air valve with SS 304 float gun metal nozzle of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charge, octroi, inspection, charge, loading, unloading, conveyance to departmental stores, stores etc. complete. 80 mm
Lowering, laying and jointing C. I. / D/F Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 80 mm
Fully electrically operated E.O.T. crane with electrically operated hoist Supply, installation, testing & commissioning of Fully lectrically operated E.O.T. crane with electrically operated hoist, class II duty, geared travelling trolley with seven meter lift complete with long travel rail track (40 mm sq. bar), moving or cross girder, all three motions electrically operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety device, cables form motor to starter panel & other required accessories & tested as per IS Specifications. Capacity : 2 Tonne Span : 6 -9 m / as per requirement Life : 6 - 10 m / as per requirement
Chain Pulley Block Supply, installation, testing & commissioning of Chain Pulley Block triple gear arrangement, lifting hook, laod chain & hand chain & locking device etc. Capacity : 2 Tonne
Supply, Installation, Testing & Commissioning including cost of all labour of CI FG 260 SLUICE GATE as per latest revision of IS 13349 with wall thimble, SS 410 stem, and all accessories. For additional parameters refer specifications. Size: 800 X 800 mm
S.S. Fabrication work Supply, Installation, Testing & Commissioning including cost of all labour of SS 304 MANUAL BAR SCREEN as per technical specifications.
M.S. Fabrication work Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete.
C.I. work Supply, Installation, Testing & Commissioning including cost of all labor of CI piping, fitting and specials as per technical specifications.
Supply, Installation, Testing & Commissioning including cost of all labour of Multi Rake Mechanical BAR SCREEN - SS 304 as per technical specifications.
Pressure Transmitter Design, Supply, Installation, Testing and Commissioning of Sealed Diaphragm Type Pressure Transmitter. Piezo-resistive sensor technolgy based pressure transmitter with Micro-processor based integral LED/ LCD display, with accuracy of ± 0.3% of span, external zero and span adjustment, self diagnostics, temperature sensor for compensation. 15 to 36 V DC power supply, output signal of 4-20 mA DC with HART. Minimum IP 65 degree of protection. Aluminium housing with epoxy coating, Accessories like snubbers for pump discharge applications, three way manifold, mounting brackets, name plate etc. Material for accessories shall be SS. Protection Box/Canopy shall be provided for outside installed transmitters.Pressure Transmitter shall be suitable for common discharge header having range 0-10 kg/cm2.
Displacer Type level switch Design, Supply, Installation, Testing and Commissioning of Top mounted Displacer Type level switches with 2 nos SPDT contacts of Micro switch rated 5 A, potential free power supply, Material of wetted parts shall be SS 316 and the material of accessories shall be SS. IP 65 or equivalent degree of protection for enclosure, suitable for sump, ESR, tank, vessels and underground reservoirs. The top mounted level switches shall be supplied with still tubes to suit the requirement. Accessories like name plate, mating flange, gaskets, fasteners, bolts & nuts, etc. shall be supplied with the Level Switch of following Range at the wet well including control cables required.
Ultrasonic Type Level Transmitter with Integral Display : Design, Supply, Installation, Testing and Commissioning of NOn Contact Ultrasonic Type Level Transmitter with Integral Display.Sensor with Head Mounted Transmitter:The sensor should be non contact type, field mounting type, housing shall have minimum IP65 protection, PP/ PVC Sensor MOC, Microprocessor based indicator with LED / LCD digital display,panel/ wall mounting type, power supply shall be 110- 240 Vac or 15 to 36 Vdc, 50 Hz ± 10 %. Accesories: Mounting bracket, nut, bolts etc as per system requirement and Hook up diagram of the Instruments. Level Transmitter shall be suitable for following Range. compatible to GSM/GPRS connectivity. Range : 0 to 15 m
Full Bore Electromagnetic Flow Meter (Inbuilt Battery Power Operated) Design, Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow meter with factory calibration, Inbuilt Battery Power Operated, flanged connection, Flow sensor, indicator, transmitter and totaliser with all accessories viz. surge arrestor, associated cables, cabinets, hardwares, etc complete as per following specifications: Flow Meter/ Sensor: DC pulsed type, IP 68 Protection, Flanged process connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt Grounding Electrode, Neoprene/Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, CS flanges. Flow Transmitter/ Converter ( Remote Field Mounted): Microprocessor based, Modular design, 2 line LCD for indication of actual flow rate, forward, everse, sum totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity, one scalable pulse/ one status, one Modbus output, one GPRS/ GSM output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger, 20 meters cable length for sensor to transmitter communication, Minimum 5 years battery lifetime, 3.6 VDC Non Rechargeable Lithium-thionyl chloride/ Ni-Cd high power batteries, Hourly Basis Worldwide transmission of measured data and events via e‐mail and SMS by integrated GSM/GPRS modem, Reliable data storage facility through integrated SD card etc alongwith wall mounted/ stand mounted cabinet.Size: 150 mm
Size : 200 mm
Size : 350 mm
Size : 600 mm
ICP CUBICLE - PLC SCADA SYSTEM ICP cubicle panel with required input / output for field instruments interfacing at terminal strip& comprising of (a) Door mounted 2 nos. flow indicator cum totalizer (FIQ) for flow meter, 2 no. Process indicator for Level transmitter at sump and pressure transmitter at delivery header. (b) Required separate isolation switches (DP MCB only) for incoming 230 V AC power mains from UPS & each of the outgoing power feed to 2 nos. flowmeter, 2 nos. Flow indicator cum totalizer (FIQ), 2 no. Process indicator , 6 window alarm annunciator , etc.(c) 1 no. Multiplication relay (1 input + 7 output) for dry run protection of pump and low low level alarm. (d) Offline type UPS of suitable rating (min. 500 VA with 15-20 min. backup time ) mounted within cubicle on main incoming power line with required isolation device (DP MCB) & outgoing feed to power supply of instruments. (e) Any other as required to complete the work and meet the requirement/specification.
INSTRUMENT CABLE & ACCESSORIES Supply, Laying, Installation, Connection, Termination, Testing & Commissioning of Instrument Cables, along with cable glands, lugs, cable trays, required junction boxes, fittings and accessories as per specs. The unit rate shall include POWER CABLE 3C x 1.5sq.mm
CONTROL CABLE 2C x 1.5sq.mm.
SIGNAL CABLE 1P x 1.5sq.mm.
INSTRUMENT CABLE TRAY G.I. Perorated type cable tray shall be made out of galvanized mild steel sheets of 2.5 mm thickness with required accessories. All material shall be Hot dip galvanised as per IS (816 g/m2) as mentioned in specification and tray hardware shall be in GI.50 x 50 mm - Perforated type
CABLE END TERMINATION AND CONNECTION Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type Bimetallic lugs / sockets with necessary tools and equipments as specified in specifications and IS complete in all respects. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh as applicable. POWER CABLE 3C x 1.5 sq. mm
CONTROL CABLE 2C x 1.5sq.mm
SIGNAL CABLE 1P x 1.5sq.mm.
11 kV Four Pole Structure Assembly: SITC of 11 kV double pole 9 meter high structure made of 6" X 3" 'I" section girder, 4" X 2" channels, clamps, nuts, bolts, stay wires including earthing system with following accessories duly connected with ACSR conductors as per approved drawing & in compliance with requirement of IEC.(a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP) tubes: 2 Set (01 piece per phase / circuit).(b) 11 kV, 400 A G.O.D. switch complete with earth switch, insulators, operating handle with galvanised pipe, square bar: 2 Set.(c) 11 kV lightning arrestor with clamps: 3 Nos.(d) 11 kV Disc Insulators (70KN): 9 Nos.(e) 11 kV Pin Insulators (5KN): 6 Nos.(f) 20 mm dia. GI. Stay Set Complete: 2 Set
Supply, laying, testing & commissioning 11 / 11 kV (UE) grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-2) & IEC: 60502(Part-2), of following sizes: 3 Core x 70 Sqmm
SITC heat shrink cable termination / jointing kits for 6.6 kV (UE) / 11 kV (E) grade XLPE insulated cable including necessary earth connectivity connection, material & consummables making the termination/ joint complete ensuring the joint resistance is within the permissble limit as per IS, of following types & sizes: Outdoor Terminations Kit suitable for 3 Core x 70 Sqmm
Transformer SITC of outdoor type, three phase, oil immersed, distribution transformer of required KVA & voltage ratio, copper double wound, vector group - Dyn11, HV delta connected & LV star connected with neutral brought out connected to provide separate earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables or bus duct as per requirement with standard fittings, conforming to IS: 1180 (Part-1) / 2014 with its latest amendment including first fill of transformer oil & following accessories. (a) Oil conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating breather charged with silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e) Lifting Eyes / Hooks / Lugs (f) Two earthing terminal (g) Diagram and rating plate (h) Air release plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-directional plain roller with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit externally operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature indicator (For rating < 500 kVA) (o) Bucholtz relay with shut off valve (For rating ≥ 500 KVA) (p) 150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating ≥ 500 kVA) (q) 150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating ≥ 1000 kVA) (r) Marshalling box (For rating ≥ 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating ≥ 1600 kVA) (t) Inspection cover & Jacking lugs (For rating ≥ 1600 kVA) For transformer having oil storage capacity for 2000 liters and higher, nitrogen injection fire protection system (NIFPS) is to be provided. 160 KVA
Electrical Works Supply, installation, testing & commissioning of PMCC/MCC Panel for Zone- 1 as per specification
Supply, installation, testing & commissioning of PMCC/MCC Panel for Zone- 2 as per specification
Supply, installation, testing & commissioning of PMCC/MCC Panel for Zone- 3 as per specification
Supply, installation, testing & commissioning of PMCC/MCC Panel for Zone- 3A as per specification
1100V Grade LV Cables: S.I.T.C. of XLPE insulated, 1100V grade, Galvanised steel wire / strip armoured, stranded aluminum/Copper conductor, PVC tape inner sheathed, cores laid up, Extruded PVC type ST2 sheathed cables as per IS 7098 (Part-I) 1985 of following core & size to be laid on wall with necessary clamps / in cable trench / on cable trays / conduit pipe as per site requirement. AI 3.5 C x 300 Sq. mm A2XFY
AI 4 C x 50 Sq. mm A2XFY
AI 4 C x 50 Sq. mm A2XFY
CU 4 C x 4 Sq. mm A2XFY
CU 4 C x 10 Sq. mm A2XFY
4C x 2.5 Sq. mm 2YWY
Cable Glands /Termination: S.I.T.C. of heavy duty flange type brass cable glands with rubber rings for suitable size PVC armoured cable complete with outgoing tails, insulating type etc. for following size of cables. 3.5 C x 300 Sq. mm A2XFY
AI 4 C x 50 Sq. mm A2XFY
AI 4 C x 50 Sq. mm A2XFY
4 C x 4 Sq. mm A2XFY
4 C x 10 Sq. mm A2XFY
4C x 2.5 Sq. mm 2YWY
Cable Trays & Accessories: Supply & laying FRP ladder type cable trays with C shaped side channels of size - 75 x 25 x 25 mm for 150 mm wide and 100 x 75 x 75 mm for 300 mm wide & above, rungs of 25 mm square hollow tube spaced at 300 mm apart, manufactured as per NEMA FGI-1993 / IS 6746 - 1994/ ASTM-D standards using corrosion resistant polyester flame retardant U.V stabilised resin & various types of glass fibres with glass content ≥ 55% with minimum thickness of 3.0 mm for all sizes upto 150 mm (W) & 4.0 mm thickness for all sizes of 300 mm & above, supplied in standard length of 3 mtr including accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized / SS-304 hardware etc, erected on existing support as per specification and instruction of engineer in charge 300(W) x 100(H) x 4 mm Thick
150(W) x 75(H) x 4 mm Thick
Supply & laying FRP perforated type cable trays manufactured as per NEMA FGI-1993 / IS 6746 - 1994/ ASTM-D standards using corrosion resistant polyester flame retardant U.V stabilised resin & various types of glass fibres with glass content ≥ 55% with minimum thickness of 3.0 mm for all sizes upto 150 mm (W) & 4.0 mm thickness for all sizes of 300 mm & above, supplied in standard length of 3 mtr including accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized / SS-304 hardware etc, erected on existing support as per specification and instruction of engineer in charge. 150(W) x 50(H) x 3 mm Thick
Indoor & Outdoor Lighting & Ventilation System: Design, supply, erection, testing and commissioning of suitable general lighting arrangement for pump house, electrical room, including required lighting fixtures, fittings, point wiring, distribution box, street lighting poles with junction box, exhaust fan etc. with complete job.(a) Point Wiring for light/fan/Bell/Primary point with 2-1.0 sqmm & earthwire of 1.0 Sqm.mm (green) both are of ISI marked for PVC insulated multisrand copper wire, in pipe duly erected, complete with 6A Modular type ISI marked flush type switch/ bell push and accesorries erected on polished wooden block/ Metal. PVC box covered with 3 mm thick laminated sheet for concealed wiring as per specification.
(b) 40W LED Fixtures and associated fittings for Electrical/ Switchgear/ Control/ Office/ pump room
(c) 70W LED lighting fixture with 6 m pole with all necessary fittings for outdoor application -6 nos.
(c) 70W LED lighting fixture with 6 m pole with all necessary fittings for outdoor application -4 nos.
(d) 70W LED lighting fixture with all necessary fittings for outdoor application (For building periphery of Electrical Switchgear Room )
(e) 15W LED lighting fixture with all necessary fittings for indoor application
(f) Supplying and fixing of the ceiling fans of approved make for electrical/Control room with 1200mm sweep, white color, double ball bearing, 300mm long down rod, Electronic type approved make regulator and accessories i.e. screws, wall nuts etc.
(g) Supply, fixing and commissioning of 305mm dia Exhaust fans including bird louvers, frame works and other civil works like chipping and making the surface good etc.
(h) Supplying and fixing of 150mm x150mm x125mm weather proof outdoor type junction box fabricated out of 14 SWG CRCA sheet of IP 54 category of protection with rubber gasket and having locking arrangement including required connectors & 10A SP MCB-10 Nos..
(h) Supplying and fixing of 150mm x150mm x125mm weather proof outdoor type junction box fabricated out of 14 SWG CRCA sheet of IP 54 category of protection with rubber gasket and having locking arrangement including required connectors & 10A SP MCB-5 Nos.
Earthing & Lightning Protection System: S.I.T.C. of earth pit of minimum bore dia 150 mm size aproved make Safe Earthing Electrode consisting pipe-in pipe Technology made of corrosion free GI Pipe having outer pipe dia of 50 mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising connection terminal dia. of 12 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications.For Electrical installation covering LT Switchgear, Motors/ Starters & Lightning Protection System i.e. independent earthing in normal soil with Length of Pipe 3.00 mtr. & Back filling compound - 2 No. Bag of 25Kg each.
S.I.T.C. of funnel type Earthing having earth plate of following size burried in specially prepared earth pit 3.0 mtr below ground with 40.0 kg charcoal and salt with alternate layers of charcoal and salt 20 mm dia GI pipe with funnel with wire mesh for watering and brick massonary block and C.I. cover complete as per para 7.3 of IS: 3043 with necessary length of Cu. strip/ flat 25x6mm bolted with lug to the paltened covered in 12 mm dia G.I. pipe 2.5 mtr long complete connected to the nearest switch gear with end socket as per direction and duly tested by earth tester confirming to IS as per drawing with following specifications. complete with 60 x 60 x 0.315 cm Copper earth plate (For DG neutrals)
Providing and Erecting required size of Copper strip for earthing.
Providing and Erecting required size of GI strip for earthing of electrical equipment i.e. LT Switchgear, Motors/ Starters & Lightning Protection System, Cable trays etc.
Providing & erecting Hot dip Galvanisied strip/ iron wire 8 to 16 SWG for Aux. DB & LPBS etc.
Fire & Safety Equipments: Design, supply, erection, testing and commissioning of safety accessories for all electrical equipment/ system. (a) Supply 6 mm thick Rubber Mat for HV & LV of required length and breath.
(b) Providing printed Instruction Chart both in English and Gujarati and duly framed with front glasses for treatment of person suffering fron electric shock.
(c) Supplying standard First Aid Box with all the standard contents.
(d) Fire Bucket with 9 Litre Capacity.
(e) Fire Bucket Stand.
(f) Fire Extinguisher (4.5 KG CO2 Type).
(g) 11kV Rubber Hand Gloves.
(F) Continuous Rating of 40 KVA ,BHP not less than 52 BHP
(C) Continuous Rating of 20 KVA ,BHP not less than 26 BHP
AMF Control Panel Providing & erecting approved make AMF control panel suitable for following size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of scope as detailed below: 1) Power module: A pair of electromechanically interlocked contactors (for mains & generator) Overload relay for generator contactor Neutral contactor for mains and generator Power socket for connections. 2) Control and metering module: Line voltage monitor. Generator voltage monitor Ammeter 3 items attempt start facility. Air circuit breakers/MCB/MCCB of suitable rating for auto/manual operation. Auto/manual switch. Emergency stop push buttons. Manual start push button. frequency meter. Engine hour meter. Two earthing studs. 3) Protection module: The engine shutdown in the unlikely event of Low lube oil pressure High cylinder head temperature. V belt failure. 4) Indicators with alarm Load on generator. 5) Indicators Load on mains Engine fails to start . Emergency stop battery charger. The AMF Panel of following capacity AMF Control Panel for 160 KVA 3 phase DG Set
AMF Control Panel for 40 KVA 3 phase DG Set
AMF Control Panel for 20 KVA 3 phase DG Set
Acoustic enclosure (Canopy) Supplying and erecting Acoustic enclosure (canopy) made out of 18 SWG, CRCA Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick conforming to IS:8183 The resin bonded Rockwool covered from inside level not more than 75 dB at a distance of 1 mtr, as PVCT norms , on provided foundation suitable for following size of DG Set. The enclosures for following capacity of DG sets. For 160 KVAD.G. set
For 40 KVAD.G. set
For 20 KVAD.G. set
Providing and Supplying of ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. PN-1 with gear operated (Alt -1 type long body) (1) 600 mm dia
(2) 350 mm dia
(3) 200 mm dia
(4) 150 mm dia
PN-1 With hand wheel /cap operated (PD type short body) (1) 50 mm dia
(2) 80 mm dia
(3) 150 mm dia
Providing and Supplying of C. I. Air valves of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. Kinetic Air Valve (DK) (1) 150 mm dia
(2) 80 mm dia
(3) 50 mm dia
Providing and Supplying of ISI mark CI D/F Sluice Valves for Scour Valve as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. PN-1 With hand wheel /cap operated (PD type short body) (1) 350 mm dia
(2) 200 mm dia
(3) 150 mm dia
(4) 100 mm dia
Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for use with D.I. Pipes manufactured as per IS:8329/1994delivery of specials is to be made to GWSSB store or site of works any where in Gujarat including all taxes, loading, unloading, carting, stacking, insurance, inspection charges, octroi etc. complete. Socket & Spigot Type 350 mm & Above
Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees, reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for use with D.I. Pipes manufactured as per IS:8329/1994delivery of specials is to be made to GWSSB store or site of works any where in Gujarat including all taxes, loading, unloading, carting, stacking, insurance, inspection charges, octroi etc. complete. Flanged ended 350 mm & Above
Providing and Supplying D. I. K-9 grade pipes for following nominal bore diameter with internal cement mortar lining including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. (IS 8329-2000). (1) 600 mm dia
(2) 350 mm Dia
(3) 200 mm Dia
(4) 150 mm Dia
(5) 100 mm Dia
Excavation for pipeline trenches for water supply, sewerage line, machinehole etc. all with shoring and struting if required as per required gradient and line including safety provision using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. Metalled Road
Excavation in bitumious road as pee required gradient and line including safety provision using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. compelete for all lifts as specified Excavation in bituminous road
Excavation for pipe line trenches for water supply, sewerage line, machinehole etc. all with shoring and struting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for all lifts and strata as specified. In all sorts of soil and soft murrum (A) depth 0.00 to 1.50 mt.
(B) depth 1.5 to 3.00 mt.
(C) depth 3.00 to 4.50 mt.
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. (1) 600 mm dia
(2) 350 mm dia
(3) 200 mm dia
(4) 150 mm dia
(5) 80 mm dia
(6) 50 mm dia
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.Kinetic Air Valve (DK) (1)150 mm dia
(2) 80 mm dia
(3) 50 mm dia
Lowering, laying and jointing in position following C. I. / D/F Reflux valves, Butterfly valves, Sluice valves and Air valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete.(1) 350 mm dia
(2) 200 mm dia
(3) 150 mm dia
(4) 100 mm dia
Lowering, laying and jointing D. I. S & S Spun pipes suitable for Tyton joints / Mortar lined D. I. Pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including hydraulic testing etc. comp.(1) 600 mm dia
(2) 350 mm Dia
(3) 200 mm Dia
(4) 150 mm Dia
(5) 100 mm Dia
Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. consolidation curing etc. complete. without Form Work
Providing and constructing brick work using common burnt clay Fly Ash building bricks having crushing strength not less than 35Kg/Sq.cm. in foundation and plinth incl. racking out joints, watering etc. as directed in CM 1:6 (1 Cement:6 corse sand)
Providing & Applying 15 mm thick plaster in single coat on brick/concrete walls similar surfaces for plastering & finished even & smooth with a floating coat of cement slurry mixed with admixture of lime or neeru in required proportion etc. comp. in C.M. 1:3 (1 Cement: 3 sand)
Providing and casting in situ C.C. in grade M-20 (proportions as per mix design or as per table9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, formwork, needle vibrated consolidation, curing complete up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. (for Sluice valve, Scour valve and Air Valves)
Supplying cutting, bending, binding and placing in position steel as per plan and design and as per ISS 2502 including cost of steel and binding wire for reservoirs/structures only including lift up to 6 meter height or depth below G.L. for all diameters Do-Thermo mechanically treated (TMT)bars Fe-415 grade for all diameters.
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per type design & Drawing including cost of reinforcement M.S. Angles or Flat, curing mold work etc. (a) Heavy duty
Providing CI steps in masonary of 4.5 kg weight in C.M. 1:3 including necessary CC for jointing etc complete during progress of the work.
Fixing CI steps in masonary in C.M. 1:3 including necessary CC for jointing etc complete during progress of the work.
Cutting the C.I/D.I. Pipe in pieces as necessary for fitting the special like Tee, bend etc. complete.Pipe thickness up to 10mm
Providing & fabricating the clamping arrangement for caps, plugs at the open end of the pipe line inclg. necessary excavation dewatering if any, welding, fabrication, nuts, bolts etc comp. as per engineer in charge.
Providing and casting in situ C.C. in grade M-15 (approx. corresp. to prop. 1:2:4) (proportions as per mix design or as per Table 9 of IS456 2000 in masses by weigh batching ) using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work, including scaffolding centering, form work, needle vibrated consolidation, curing comp. up to 6 meter depth or height (excluding cost of reinforcement and neat finishing) with centering and shuttering/deshuttering etc. comp. for the thrust block inclg. cost of form work.
Dewatering by pumping set of required capacity including temporary platform carting pumping at site and fixing the same in position including all accessories, and fuel and labour etc. complete.
Refilling the pipeline trenches incl. ramming, watering, consolidating desposal of surplus stuff as directed within a radius of 3 km. Refilling as directed
Demolition/Dismentalling RCC work or masonary work or removing of paver block flooring in any part inculuding stacking of serviceable/useful material and disposal of unserviceable material with all lead and lift. (a) Brick masonary work/Paver block
(b) RCC work
(c) Unreinforce c.c.
Drilling of various dia Horizontal borehole for watermain pipeline crossing under the road incl in all strata with requried length incl providing and fixing of various dia M.S casing pipe with pushing etc complete Without Water main with casing pipe 1028 mm dia 14 mm thickness
Box cutting the road surface to proper slop and camber for raod work, lime flyash stabilization with lime @ 10kg/sqmtr.+ flyash@50kg/sqmtr. And mixing with disc harrowing, Granular Sub Base (drainage layer) conforming to grading V of Table 400-1 of compacted thickness of 150 mmrolling and compactiion of subgrade, Wet Mix Macadam with paver finisher in specified thickness, each layer not exceeding 150 mm compacted thickness including premixing in WMM plant, Prime coat SS-I bitumen emulsion @ 0.85kg per sq.mtr. & RS-I bitumen imulsion @ 0.27kg per sq.mtr.,Tack Coat RS-0.25 Kg per sq.m. DENSE GRADED BITUMINOUS MACADAM as per gradation and bitumen for mixing shall be as arrived from mix design, provided in no case it shall be less than 4.0% by wt.,using aggregates as per gradation and percentage of bitumen for mixing shall be as arrived from mix design, spreading ston dust, preparing suraface and scarifying the surface.
Providing & fixing interlocking type Cement Concrete paver block of approved shape & design having 80 mm thickness (M-30) purchased from SMC's approved paverblock manufacturer only on Granular Sub Base (drainage layer) conforming to Grading II of Table 400.2 of compacted thickness of 150mm bedding. Item includes leveling by using vibratory plates compacted machine. Item also includes all materials, Labour, euipments, tools, plants, watering, cleaning etc. complete.
Providing and laying Granular Sub Base (drainage layer) conforming to Grading II of Table 400.2 of compacted thickness of 150mm with specification graded stone metal and sand mixed in pugmill and laid with mechanical means spreading with motor grader and compacting with vibratory roller having minimum 80-100KN static weight to achieve desired density of 98% o MDD including all material, labour, machinery with all leads and lifts ec. complete
Providing & laying Dry Lean Concrete sub base 75 mm thick including providing coarse and ine aggregate to the specified gradation using minimum cement content 150kg/cum of concrete with OPC 43 grade cement, mixing of concrete as per approved design mix using mechanized batch mix plant of appropriate capacity, transporting and laying with self propelled paver with electronic sensor device and compacting with vibrating roller of minimum 80-100KN static weight to give desired compaced density and average compressive strength of 10MPa at 7days and curing with liquid cuing compound and sprinkling water and covering with moist hessian or ponding of water for 7days including providing construction joints, incuding all material, labur, machinery with all ledas and lifts etc. complete
Providing and laying 160 mm thick Pavement Quality Concrete of M35 grade including providing 125micron thick impermeable plastic sheet membrane ovwewr the surface to be covered, coarse and fine aggregates of specified gradation OPC 43 grade cement, approved admixture and adding Recron 3S or equivalent fibers @ 0.25% by weight of cementations material mixed and supplied by standard RMC plant or in fully automatic concrete batching plant of appropriate capacity and with comnputerized controls as per the design mix to the the specified workability, transpirting the mix with dumpers or transit mixers and laying with channel section of required thickness byfix form/manually with all vibratory equipments, curig with approved resin based aluminized reflective curing comound and covering with moist hessian and ponding and sprinkling of water for a minimum period of 14days and including, aproved liquid seals of either polysulphide/olyrethene for joint filling and sealing all types of joints and finishing to the desired surface texture including all material, labour, machinery, formwork with all leads and lifts etc. complete
Sewage Treatment Plant: Design, supply, construction, installation, testing and commissioning of sewage treatment plant based on open technology with Biological Nutrient Removal (BNR) with MCC panel room, DG set and all civil, electrical, mechanical, piping, instrumentation, storm drainage network and other ancillary works including Boring for water supply, toilet block, internal roads, Admin building, Garden in STP Compund with three months trial run complete in all respects including one laboratory with necessary laboratory instruments. 5 to 10 MLD
Fixed Cost towards Operation and Maintenance of all the components proposed in the project related to Sewage Collection system, Interceptor & Diversion Line, Sewage Pumping Station, Rising Main, Sewage Treatment Plant under the scope of this tender - per month for 1st Year of Operation and Maintanance including manpower, all major – minor spares with necessary repair and replacement etc.# Rate should be quoted per month only
Fixed Cost towards Operation and Maintenance of all the components proposed in the project related to Sewage Collection system, Interceptor & Diversion Line, Sewage Pumping Station, Rising Main, Sewage Treatment Plant under the scope of this tender - per month for 2nd year and subsequent year (i.e. up to 5th year) of Operation and Maintanance including manpower, all major – minor spares with necessary repair and replacement etc.# Rate should be quoted per month only
Variable Cost towards Operation and Maintenance of all the components proposed in the Sewage Treatment Plant under the scope of this tender – Rate should be quoted per MLD only over here
ENVIRAD PROJECTS PVT. LTD.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid