Loading…
Loading…
Tender Value
Refer Docs
Closing Date
16 Sept 2026, 2:30 pm4d left
DGM(CMSRU)
CMSRU, Hughes Drydock Office Building, Mumbai Port Authority, Blue Gate, P.D. Mello Road, Mumbai-400001
STRUCTURAL STABILITY ASSESSMENT and CERTIFICATION OF CMSRU BUILDINGS
2026_CSL_289495_1
CMSRU/MP1/2026/80
Open Tender
Civil Works - Others
Works
Mumbai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
16 Sept 2026
4 Sept 2026
17 Sept 2026
4 Sept 2026
16 Sept 2026
4 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | STRUCTURAL STABILITY ASSESSMENT & CERTIFICATION | - | - | - | - |
| 3 | Comprehensive visual inspection of the building, both internally and externally, including systematic mapping of all visible structural and non-structural defects such as cracks, spalling, corrosion stains, dampness, leakages, honeycombing, distress, deformation, and other signs of deterioration. The inspection & NDT shall include
photographic documentation.
Structures Included in scope :
1. HDD Building
2 Basement Shipyard
3 Warehouses | 1 | AU | - | - |
| 4 | Ultrasonic Pulse Velocity Test for RCC structure in accordance with IS 516 (Part 5/Sec 1): 2018 | 95 | Nos | - | - |
| 5 | Rebound Hammer Test in accordance with IS 516 (Part 5/Sec 4):
2020 | 95 | Nos | - | - |
| 6 | Half Cell Potentiometer Test in accordance with IS 516 (Part 5/Sec
2): 2021 - Standard Test Method for Corrosion Potentials of
Uncoated Reinforcing Steel in Concrete. | 47 | Nos | - | - |
| 7 | Carbonation Test for RCC structure to find out the thickness of carbonated cover concrete. | 47 | Nos | - | - |
| 8 | Chemical Test in accordanace with IS 456 2000 to determine the pH value, sulphate contents and chloride contents. | 10 | Nos | - | - |
| 9 | Cover Meter Test to identify the exact cover concrete thickness of RCC members | 47 | Nos | - | - |
| 10 | Core Test in accordance with IS 516 on RCC members. 70mm core cutting in reinforced concrete, core filling by micro-concrete | 10 | Nos | - | - |
| 11 | Ultrasonic Gauge Thickness Test : Ultrasonic measurement of the remaining thickness of steel members to assess section loss due to corrosion or erosion. | 40 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
PDFsam_merge.pdf
Tender Documents • 1.64 MB
BOQ_337705.xls
BOQ • 0.26 MB
Corrigendum1.pdf
PDF • 8.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .