Tender Value
₹26.6 L
EMD Value
₹27,000
Closing Date
1 Jul 2021, 1:00 pmClosed
SE ETC Mathura
132 KV S/S Aurangabad Mathura
Work of Installation of Air Conditioners, Fire Alarm System and other associated works at 220 KV S/S Meetai Under ETDHathras
2021_UPTCL_582582_2
ET-08/ETC(M)/21-22
Open Tender
Electrical Works
Lump-sum
60 days
Under ETC Mathura
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE ETD Mathura
₹27,000
20 Jul 2021
21 Jun 2021
2 Jul 2021
21 Jun 2021
1 Jul 2021
21 Jun 2021
Amount
Supply, fixing, testing &commissioning of ductable air conditioner system at 220KV S/S MEETAI under ETD-Hathras. The work shall be to install Air Conditioner, aluminium partitions, doors and windows and fire alarm system dedicated for panel room and other room associated with this buidling.
Providing & fixing fully glazed anodized/powder coated heavy duty aluminium fixed shutters or frame of hindalco or equivalent extruded standered section of thickness 2 mm as per drawing & sample including providing & fixing 5.0 mm thick glass of Modi/Sent Gobin with neoprene rubber beading all around The minimum thickness of anodizing on all aluminium section 10-12 micron with ±2 micron tolerance. The rate includes the cost of fixing aluminium frame to wooden/masonary RB/RCC structure by means 80 mm long counter sunk screws as per drawing/direction of incharge including cost of men T&P required completion of work.
Providing & fixing fully glazed anodized/powder coated heavy duty aluminium opnable sliding or pivoting window shutters frame of hindalco or equilent extruded standered section of thickness 2 mm as per drawing & sample including providing & fixing 5.0 mm thick glass of Modi/Sent Gobin with neoprene rubber beading all around The minimum thickness of anodizing on all aluminium section 10-12 micron with ±2 micron tolerance. The rate includes the cost of fixing aluminium frame to wooden/masonary RB/RCC structure by means 80 mm long counter sunk screws as per drawing/direction of incharge including cost of men T&P required completion of work.
Providing & fixing fully glazed anodized/powder coated heavy duty aluminium opneble sliding or pivoting gate/door frame of hindalco or equivalent extruded standered section of thickness 2 mm as per approved drawing & sample including providing & fixing 5.0 mm thick glass of Modi/Sent Gobin with neoprene rubber beading all around The minimum thickness of anodizing on all aluminium section 10-12 micron with ±2 micron tolerance. The rate includes the cost of fixing aluminium frame to wooden/masonary RB/RCC structure by means 80 mm long counter sunk screws as per drawing/direction of incharge including cost of men T&P required completion of work.
Providing & fixing of door closer of standrad quality and makes as per sample including cost of all material, men and T&P.
Provinding & fixing aluminium round shape handle of outer dia 100mm with SS screw and brass locks for aluminium doors including necessary cutting & other associated work complete powder coated minimum thickness 50micron aluminium.
Supply & Installation of 5.5 Ton Split Ductable Air Conditioning Units comprising of Scroll Compressure. DX.MCXH Evaporator coil, thermostatic expansion device, air-cooled condensers with specially coated fins. Centrifugal blower, TEFC Motor, Micro-processor based control panel having centrifugal forward curved, double width air delivery system with 220 ocfm capacity, etc (Bluestar/Carrier) strictly as per teach specification.
Providing & Fixing of False Ceiling as per technical specification.
Supply &fixing of 1x36 Watt LED lighting of size 2ftx2ft, CGL/Bajaj make recessed type to be fixed in false ceiling.
Supply & fixing LED based 110V DC operated lighting system for emergency supply in control room including laying of circuit from DCDB to point in MS Conduit Pipe including cost of all material, men and T&P.
Supply & fixing of sub main distribution box with 100Amp MCB Isolator and 12 Nos. SP MCB of different rating inside fixed sheet metal enclosure of 16 SWG of proper size.
Supply & Laying of MS Conduit Pipe 25 mm including bending, making junction and other associated work as per site requirment.
Dismantalling of old installed main door frame/window doors & all other doors as per requirement of site.
Wiring of L&F 5 Amp. With piano key type swithches of standard make like Anchor/kingal using PVC insulated copper wire of 1.5 sq. mm of good quality as per ISI specification as approved by Engineer incharge and earth continuity wire 0.75mm in 25mm dia PVC Pipe including juncion boxs fitted with white Sunmika base and other material of good quality for completion of work in all respect.
Wiring point for 5 Amp plug socked of standerd make like Anchor/kingal with 1.5 sq. mm. insulated copper wire and its earth continuity wire details.
Wiring point for 15 Amp Piano type switch and socket with 2.5 sq. mm insulated copper wire good quality as per specification as approved by Engineer in charge.
Power supply Panel with timer as per the manufacturer specification 8x5.5 Ton air Conditioning units Ratting.
Laying of different circuit of sub main to individual switch board.
Supply of 16-20 zone conventional fire detection and fire alarm system with power supply arrangement. (Make Competable with IS-2189 1999 Tested by ERTL(N) and system sensor, Agni Suraksha. Agni devices/Daksh or equivelent.
Supply Manual Call Point A breakable glass cover fixed in such a way that the actuating push button is intact and released when glass is broken A Small steel hammer shall be attached to the assembly with steel chain to facilitate breaking of glass. The manual call points shall be suitable for surface or fully/partly recessed mounting 5mm high red painting/printed word "IN CASE OF FIRE. BREAK GLASS" shall be provided on front face. The manual call point shall compatible with all conventional control panels. (Make-Agni-Suraksha (ASES) Safeway Equivelent/Agni Devices.
Electronic hooter 11 db/24V DC with strob (ABS-V) The Enclosure should be 1.5mm thickness duly painted and marked "FIRE ALARM" All hooter shall produce a similer sound and shall maintain the same during their operation Make-Agni-Suraksha (ASES).Safeway Equivelent/Agni Devices.
Providing and Fixing of lonisation type smoke detector the detector while sensative to all type of smoke will be in sensitive to ambient lights are drafts and changes with the operating tempreature and voltage ranges. The Detector shall meet the requirement of either EN54/FM/UL or LPC and shall be specifically approved by FM/UL/LPCB Apollo/system sensor/Edward/Bosch.
Providing and Fixing of Detector (for the area like battery room. A/C Plant Area, DG Room Etc.) It is a combination of rate of rise and fixed tempreature principal using Thermister and with automatic compensation for changes of ambient conditions. The Thermal Detector are tested and approved to EN54 part 5 (2000) class AIR Apollo/System Sensor/Edward/Bosch.
Providing and Fixing Response Indicator Lamp holder and lamp assembly consisting of lamp hoder and lamp shall be suitable for mounting on walls partition etc. The housing shall be suitable for surface/flush mounting on walls on 1.5 mm thick steel sheet and the facia 3mm acrylic mounted outside a cabin and directly connected to detector.
Supply and Laying of 2x1.5 sq. mm PVC insulated and seathed standard copper wire. Wiring for fire alarm system in general shall comply with IS-2189 and IS-732 amended up to date. The Detectors shall be wired by ISI marked 1.5 sq. mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade required and desired on site. Crimping type of lugs are also included in the rates of laying of wires and its connections. PVC insulated copper conductor wire shall confirm to IS:694.
Supply and Installation of SMF batteries with suitable rating Minimum 7 AH as required for 24 hours backup from exide/AMCO/Standerd
Signages with backlit facality for control building for marking exit in case of emergency.
Supply and laying of MS Conduit pipe 25mm as per requirement of site.
PARADISE INFRA POWER COMPANY
Jagad Electrical & Fabricators
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .