| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹55.3 L+₹10.0 L (22.2%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | India Guniting Corporation L2 | M/S Parmod Johar L1 |
|---|---|---|---|---|---|
| 1.00 | M & L for chipping of unsound/weak concrete/ plaster material upto 25mm average thickness from slabs, beams, coloums, wall etc with manual chiesel and/ or standard power driven percession type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc and disposal of debris for all lead and lifts all complete all as specified and as directed. | 100 | Sqm | 239 ₹23,900 | 190 ₹19,000 Lowest |
| 2.00 | Supply and inserting grouting 12mm dia GI nipple upto 30 mm to 40mm depth or half the thickness of the member which ever is less into honeycombed concrete/ normal concrete including drilling of holes, inserting nipples and sealing the gap around nipples with epoxy putty etc complete all as specified and as directed. | 200 | Each | 169 ₹33,800 | 110 ₹22,000 Lowest |
| 3.00 | M & L for sealing of crack/ porous member with epoxy grouting by injection through inserted nipples procedure with epoxy injection Gun approx 0.2 to 0.4 kg each grout complete all as specified and as directed. | 60 | Kg | 819 ₹49,140 Lowest | 1,050 ₹63,000 |
| 4.00 | M & L for cleaning reinforcement of total rust using alkaline chemical rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry complete including passivative coating over the reinforcement complete all as specified and as directed.
Note: Surface area of concrete shall be measured for payment. | 100 | Sqm | 189 ₹18,900 Lowest | 190 ₹19,000 |
| 5.00 | Supply mixing and applyingover reinforcement bars, zinc anti rust agent as per specification and direction of Engineer-in-Charge (Dosage/ coverage as per the recommendation of manufacturer).
Note: Surface area of concrete shall be measured for payment. | 100 | Sqm | 259 ₹25,900 | 200 ₹20,000 Lowest |
| 6.00 | Supply and applying concrete penetrating corrosion inhibitor "CPCI" over the entire surface @ approx 4 sqm/ lt and minimum Ph of 9.5, complete all as specified and as directed.
Note: Surface area of concrete shall be measured for payment. | 100 | Sqm | 279 ₹27,900 Lowest | 300 ₹30,000 |
| 7.00 | Supply, laying and fixing in position steel rebars of 12 mm dia in reinforced concrete work, including removal of loose concrete by wire brush, drilling hole of required size, laying in position using epoxy at all levels and heights but excluding the cost of reinforcement as per drawing and design, manufacture's specifications complete all as specified and as directed. | 10 | Each | 229 ₹2,290 Lowest | 300 ₹3,000 |
| 8.00 | All as per srl item No 7.00 here-in-before but 16 mm Dia. | 50 | Each | 289 ₹14,450 Lowest | 500 ₹25,000 |
| 9.00 | M & L for Therom mechanically Treated bars 10mm dia and over steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level confirming to grade Fe-500D or more complete all as specified and as directed. | 100 | Kg | 159 ₹15,900 | 100 ₹10,000 Lowest |
| 10.00 | M & L for shear key of L/U shaped 150 mm long, 8 mm dia mild steel shear key after drilling suitable hole in reinforced or plain cument concrete with power driven drill machine to a minimum depth of 100 mm, upto 200 mm in RCC beams, columns and slabs to intorduce steel bars including fixing the steel bars in position using, epoxy resin anchor grout of approved make but excluding the cost of reinforcement, complete all as specified and as directed. | 50 | Each | 99 ₹4,950 Lowest | 120 ₹6,000 |
Tender Value
₹48.3 L
EMD Value
₹97,000
Closing Date
4 Apr 2026, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
SPL REPAIR TO BUILDING NO P-98 UNDER AGE B/R-II AND AGE E/M OF GE (SOUTH) DELHI CANTT-10
2026_MES_756292_1
GE/TOKEN-109/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹97,000
Yes
23 May 2026
14 Mar 2026
6 Apr 2026
14 Mar 2026
4 Apr 2026
28 Mar 2026
M & L for chipping of unsound/weak concrete/ plaster material upto 25mm average thickness from slabs, beams, coloums, wall etc with manual chiesel and/ or standard power driven percession type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc and disposal of debris for all lead and lifts all complete all as specified and as directed.
Supply and inserting grouting 12mm dia GI nipple upto 30 mm to 40mm depth or half the thickness of the member which ever is less into honeycombed concrete/ normal concrete including drilling of holes, inserting nipples and sealing the gap around nipples with epoxy putty etc complete all as specified and as directed.
M & L for sealing of crack/ porous member with epoxy grouting by injection through inserted nipples procedure with epoxy injection Gun approx 0.2 to 0.4 kg each grout complete all as specified and as directed.
M & L for cleaning reinforcement of total rust using alkaline chemical rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry complete including passivative coating over the reinforcement complete all as specified and as directed. Note: Surface area of concrete shall be measured for payment.
Supply mixing and applyingover reinforcement bars, zinc anti rust agent as per specification and direction of Engineer-in-Charge (Dosage/ coverage as per the recommendation of manufacturer). Note: Surface area of concrete shall be measured for payment.
Supply and applying concrete penetrating corrosion inhibitor "CPCI" over the entire surface @ approx 4 sqm/ lt and minimum Ph of 9.5, complete all as specified and as directed. Note: Surface area of concrete shall be measured for payment.
Supply, laying and fixing in position steel rebars of 12 mm dia in reinforced concrete work, including removal of loose concrete by wire brush, drilling hole of required size, laying in position using epoxy at all levels and heights but excluding the cost of reinforcement as per drawing and design, manufacture's specifications complete all as specified and as directed.
All as per srl item No 7.00 here-in-before but 16 mm Dia.
M & L for Therom mechanically Treated bars 10mm dia and over steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level confirming to grade Fe-500D or more complete all as specified and as directed.
M & L for shear key of L/U shaped 150 mm long, 8 mm dia mild steel shear key after drilling suitable hole in reinforced or plain cument concrete with power driven drill machine to a minimum depth of 100 mm, upto 200 mm in RCC beams, columns and slabs to intorduce steel bars including fixing the steel bars in position using, epoxy resin anchor grout of approved make but excluding the cost of reinforcement, complete all as specified and as directed.
M & L for sacrifical anode cathodic protection (SACP) for distressed RCC mambers provide and install sacrificial zinc anodes to prevent initiation of corrosing of steel reinforcement in chloride conteminated or corbonated concrete complete all as specified and as directed.
Supply & Fixing adequate and leak proof plain shuttering for sides & bottom of R.C.C. element at any level including necessary scaffolding & prop of required height complete all as specified and as directed.
M & L for Micro concrete (Pre-Packed) wherever cover reinstatment is more than 60mm thick provinding and laying non-shrink/ shrinkage componented cement based prepacked single compnent Micro-convrete, ehlorode free sulphate free, free flow, self-compacting, ready to use after mixing water in specified proportion of approved quality. High strength dual shrinkage componented micro concrete for placing in nominal thickness of 25mm to 200mm for convrete repair with compressive strength similier to strength of substrate concrete) of micro concrete cubes equivalant to that of M-35 grade at 28 days age complete all as specified and as directed.
Supply, mixing and applying epoxy bonding cost of approved adhesive on chipped portion of plaster as per manufacturers specifications and direction of Enginee-In-Charge complete in all respects including carriage of materials in all leads and lifts complete all as specified and as directed.
Supply, mixing and applying SBR polymer(of appprove make ) modified cement mortar in proportion of 1:4 (1 cement ratio 4 graded coarse sand with polymer min 2% by weight of cement used) complete all as specified and as directed. Note: Mesuarement and payment : the pre measurement of thickness shall be done only after proper wet curing has been done surface has been done satisfactorily evluated by sounding/tapping up to 25mm (Make: Fosroc,Sika,BASF)
Dismantling brick tiles or terracing tiles single layer on roofs, complete all as specified and as directed.
Demolition of mud/ mud phuska in roofs any thickness, including plastering and leaping if any and removal of mud /mud phuska to a distance exceeding 250 m and not exceeding 500 m, complete all as specified directed.
M&L for cement concrete 1:2:4 type B-1 (using 12.5 mm graded crushed stone aggregate) as in roof padding including finished even & smooth without using extra cement, complete all as specified and as directed.
M&L for screed bed on concrete surfaces in cement mortar 1:3 on roof mixed with WPC and finishing the surface even and smooth complete all as specified and as directed. (WPC shall be measured and paid seperately).
Supply only Liquid water proofing compound complete all as specified and as directed.
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and as directed.
Providing and Applying water proofing coating system over horizontal and vertical surface on roof/wall by carying out : 1) Single coat of efflorescence resistance penetrating primer (Primeseal of Dr. fixit or equivalnet ) over cleaned roof surface to provide priming surface. 2) Single coat of heavy duty reinforced trafficable water proofing coating compound (New Coat of Dr. fixit or equivalent) over priming surface to give base course, 3) 45 gsm glass fiber mesh evenly over the base course to make the waterpoorfing system foot trafficable 4) Two coats of heavy duty reinforced trafficable water proofing coating compound (New Coat of Dr. fixit or equivalent) over fiber mesh to give wearing/ finished course. The cost of this work includes cost of providing and applying of priming coat, fiber mesh and 3 coats of water proofing compound including finishes, Air curing,07 days ponding, etc. Complete as per manufacturer's specification and instruction of the Engineer-in-charge.
Supplying and providing non metallic composite carbon fiber wrapping system comprising of unidirectional fiber sheet 400 GSM and compatible saturant,including surface preparation by grinding/moulding concrete, cleaning it with wire brush, removing oil,laitance etc.If present, rounding shape edges to min 25 mm,radius etc,with approved putty etc, complete wrapping the fibre sheet by tamping to avoid any air voids etc, The same procedure shall be adopted for multiple layers within an interval of 8 Hrs between consecutive layers,rectifying air voids if any, pastiing the river sand on it to make surface rought to add any further finishes. Overlaps and wastage will not be paid complete all as specified and as directed by Engineer-in-Charge. The scope of work in the item includes: 1. The item includes the cost of all operations involved to complete the job as per the specifications and conditions of contract including the cost of arrangement of all material, machinery, Tools & Plant manpower of all categories as per the directions of the Engineer-in-Charge. 2. The item includes the cost of testing of all materials involved in the execution of the item as per the requirement given in the tender documents. 3. The item includes all other incidental expenditures for completing the job as per directions of the Engineer-in-Charge.
Supplying and providing non matallic composite corbon fiber low Modulas Precured CFRP Strip of 100mm wide and 1.4mm thick including surface preparation by Grinding/ moulding concrete, cleaning it with wire brush, removing oil, laitance etc. complete all as specified and as directed.
Supply and installing 8mm dia Fiber Anchor produced by Knit-braiding process for fixing laminates & wrap complete all as specified and as directed.
Supply & laying suitable sprinkling of clean 'M' sand particle for protecting the treated surface and holding of finishing plaster/ paint wherever required complete all as specified and as directed.
Supply and applying 15mm thick smooth plaster with 1:4 CM at any level upto (G+3) incl, cleaning of surface, curing, scaffolding, mixing etc complete with all tools complete all as specified and as directed.
M&L for brick work in cement mortar (1:6) using sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius including demolition of existing brick work in any position/any type and in any shape complete all as specified and as directed.
M&L for 15mm thick rendering with ready mix plaster on brick or concrete surfaces finished even and smooth without using extra cement, levelling the surface, curing etc complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15cm thickness below or above ground level including floor finishes and removing debris from the site all as specified and as directed.
M&L for machine cut pre-polished kota stone slab flooring 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing mirror finished including screed bed and bedding layer of mortar 20 mm thick for laying floor finishes in cement mortar 1:4, complete all as specified and as directed.
M & L for prepolished Kota stone slab (any colour) 18 to 22 mm thick in riser of steps, skirting, dado and pillar, laid over rendering of 15mm in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing mirror finished complete all as specified and as directed.
M & L for Cement concrete 1:3:6 type C-2 using 20 mm graded crushed stone aggregate in plinth protection, 75 mm thick, finished fair and even without using extra cement, complete all as specified and as directed.
M&L for machine pressed, factory made, Glossy finished chequered cement concrete tiles 30cmx30cmx(22-25)mm thick, set jointed and pointed in neat cement slurry in floor with grey cement and pigment with 20 mm thick screed bed are bedding layer of cement mortar (1:4) for laying floor finishes including dismantling of existing tiles of any description of in any position complete all as specified and as directed.
M & L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, welded or forged into spikes, framed guard bars, window/ventilator frames, barred iron doors, door sheet of any thickness, ladders, frame work for doors, framed balusters, walk ways, railings, framework of water tanks and similar work fixed in position including holdfasts or screws confirming to Fe.290.Gde-E-165 including dismatling wrought iron or mild steel/ cast iron work of any description and removing frome site complete all as specified and as directed.
Providing and fixing in position collapsible steel Gate with vertical channels 20 x 10 x 2 mm and braced with flat iron diagonals 20 x 5 mm size, with top and bottom rail of T-iron 40 x 40 x 6mm, with 40mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, complete all as specified and as directed.
S&F mild steel channel/plate girder or single stanchions built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections using Fe-410-W(Gde-E-250)quality-B, complete all as specified and as directed.
M&L for preparation of new steel surface of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of zinc chrome red oxide complete all as specified and as directed.
S&F 4 mm thick sheet glass ordinary quality n.exc 0.50 sqm each pane and fixed with oil putty or with wooden beading in square including hacking out old brockn glass (any thickness, any size or at any height) complete all as specified and as directed.
M&L for 15mm thick rendering with ready mix plaster on fair and other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement, levelling the surface, curing etc including taking down existing wall plaster complete all as specified and as directed. Note : Rate is included for necessary scaffolding etc required for plastering.
M&L for 5mm thick rendering with ready mix plaster on concrete surfaces of ceiling finished even and smooth without using extra cement, levelling the surface, curing etc including taking down existing ceiling plaster complete all as specified and as directed. Note : Rate is included for necessary scaffolding etc required for plastering.
M&L cement plaster 15mm thick in CM 1:6 on brick or conc surfaces finished even and smooth without using extra cement mixed with by adding permeability reducing polymer @ 250gm/sqm (6%) by weight of cementitious content at time of mixing with water as per manufacturer's recommendations including all levelling the surface, curing etc complete. NOTE : Rates for water proofing compound/ polymer deemed to be included in the above rates.
M &L for providing and applying a bond coat of Latex:Water:cement - 1:4:6 consumption @100gm/sqm on the brick wall surface by brush as per manufacturer's recommendations including curing complete.
M & L for expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes : Drilling holes 10mm diameter in masonary structure along the side of the joint as per manufacturer's instructions so as to cross the brick/ block at the intervals spacing of 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge. Cleaning of holes : Clean the holes by air blower prior to fixing nozzles. Install latex polymer packer injection packers 9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using sealent. Cutting of Packers : Cut the packers after completion of grouting without damaging structural elements.
Supply and apply of a 3 part, very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump injcection of polymer resin compound at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or polymer compound appears at the packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line
M&L for preparation of newly plastered surfaces of walls and applying 1-2mm thick cement base wall care putty on the whole surface to achieve smooth, even & uniform surface including grinding with sand paper and levelling of surface and applying two coats of oil bound distemper over one coat of primer, complete all as specified and directed. Note: (a) All works shall be done mechanically through authorised applicator only. (b) Authorised applicator of paint manufacture shall have valid authrisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 days from start date of the said finishing work. (c) The contractor shall provide application for testing and certification of finishes by paint manufacturing firm/ their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor.
M&L for preparation of newly plastered surfaces of ceilings and applying 1-2mm thick cement base wall care putty on the whole surface to achieve smooth, even & uniform surface including grinding with sand paper and levelling of surface and applying two coats of oil bound distemper over one coat of primer, complete all as specified and directed. Note: (a) All works shall be done mechanically through authorised applicator only. (b) Authorised applicator of paint manufacture shall have valid authrisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 days from start date of the said finishing work. (c) The contractor shall provide application for testing and certification of finishes by paint manufacturing firm/ their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor
M&L for preparation of newly plastered surfaces of walls and applying 1-2mm thick cement base wall care putty on the whole surface to achieve smooth, even & uniform surface including grinding with sand paper and levelling of surface and applying two coats of acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed. Note: (a) All works shall be done mechanically through authorised applicator only. (b) Authorised applicator of paint manufacture shall have valid authrisation letter from the manufacturer (minimum regional HQs) issued not earlier than 30 days from start date of the said finishing work. (c) The contractor shall provide application for testing and certification of finishes by paint manufacturing firm/ their authorised applicator. (d) Cost of all above aspects shall be deemed to be included in quoted rate of the contractor
M & L for complete removal of existing treatment , wahsing down and stopping and applying two coats of distemper oil emulsion, white or tinted over & including one coat of wall care putty on whole surface to achieve smooth, even & uniform surface complete all as specified and directed .
M&L for plain cement concrete 1:3:6 type B-1,using 20mm graded stone aggregates as in coping to parapet walls including necessary formwork complete all as specified and as directed.
M&L for providing and injecting chemical chlorpyrifos emulsifiable for post constructional anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes, complete all as specified and directed by engineer-in-charge.
M&L for anti termite treatment of soil under existing floors using chemical chlorpyrifog emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floors, complete all as specified and directed by engineer-in-charge.
S&F precast factory made M-30 concrete saucer drain of 600 mm long 300 mm wide and 100 mm thick set in CM 1;4 including necessary earthwork/demolition of existing pcc drain etc complete all as specified and as directed
M & L for Cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in sube base including form work if required complete all as specified and as directed.
S& F ISI marked coloured glossy finish interlocking cement paver block,any shape and size confirming to IS 15658-2006 of 80mm thickness, M-35 Grade with,topping of cement mixed with imported pigment, laid over and including 40mm thick sand cushion and joints filled with sand including dismentling of existing tiles of any description or in any position complete all as specified and directed.
M&L for continous road edging with factory made pre-cast cement concrete blocks (1:3:6) using 20mm graderd stone aggregate, blocks exceeding 10cm thick with plain fair faces with or without chamferred edge and setting and jointing in cement mortar 1:4 including necessary excavation in hard/dense soil, tamping ground aroiund blocks and removal of surplus soil to a distance not exceeding 50 metre, complete all as specified and directed.
M&L for preparation of newly kerb stone concrete/brick surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engr-in-Charge.
M&L for providing reinforcement cement concrete 1:1.5:3 (Nominal Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves including demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for RCC parapet wall,fins fascia etc complete all as specified and directed.
S&F milt steel TMT bars 10 mm dia and over , cut to length, bent to shape requred, including crancing bending and binding with mild steel (anneal) wire not less than 0.90mm dia.
M&L for from work to soffits of suspended slabs such as roof slabs, floor slabs, landing & similar work not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces, complete all as specified and directed.
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of wall to match with the original existing finish all as specified and as directed.
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
M & L for concealed flame proof point wiring with FRLS-H, PVC insulated, unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size (Phase and Neutral) alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size and through including 20 mm dia stove enamelled steel conduit incl flame proof tees, bends, junction boxes suitable for flameproof control box as per site requirement for fixing of switches, sockets and fan regulators etc including testing on completion complete including cutting chases for concealed conduit piping in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface.
All all as per item No 63.00 here in before but one 3 pin socket outlet 5 amp on the Indepdent flame proof socket board with cable 1.5 sqmm size.
Supply and fixing of LED light fitting 1 x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size and ceiling rose.
Supply & fixing of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed.
Supply & fixing of flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earthcomplete all as specified and as directed.
Supply & fixing flame proof vertical TPN DB with sheet metal enclosure 240 volts, 12 way with 200 Amp rated bus bar single pole & neutral double door type suitable for installation area Gas/vapor Grop IIA,IIB as per IS/IEC: 60079-1:2007 for MCBs including mounting work as required in position .complete all as specified and as directed.
Supply & fixing of MCCB 4P 63 amps 230 volts C curve, 50 HZ AC 10 KA suitable to flame proof TPN DB.
Supply & fixing of MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA suitable to flame proof TPN DB complete all as specified and as directed.
Supply and Fixing of Flame proof cum Waterproof LED Bulk Head light fitting of 70 W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0mm dia by mens of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing ten point all as specified and including necessary earth pit PCC 1:3:6 chanber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe medium grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 M in depth and getting out in hard /dense soil for taking up or laying of cable all as specified and directed.
Removal of surplus soil not exceed to a distance of 50 M where directed at a level not exc 1.5M above the starting point.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceding Cum 25cm complete al as specified and directed.
Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as secified and directed. Note : Punned thickness only measured and paid.
M & L for brick well brunt locally available sub class'B' laid over sand cushioning to cable in trenches keping width of brick parallel to the length of cable complete all as specified and directed.
Taking out old unserviceable XLPE cable size of 25 sqmm 3.5 core complete all directed.
Supply and laying in repair of XLPE insulated,sheathed,armoured,heavy duty LT 1100 volts grade cable 25 Sqmm 3.5 core with aluminium conductor laid in trenches/pipes, fixed to poles/walls with suitable saddle aluminium lugs, gland if required and jointed complete all as directed.
Supply and laying GI tube light grade size of 40 mm dia laid through trenches/under road floor for cable protection complete all as specified and directed.
Supply and fixing of Horizontal double mounting Siren rane 16 Kms with voltage 230V, 50 Hz, complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size
Supply and fix Air termination, single pointed, copper rod 12mm dia 300 mm long complete all as specified and as directed.
Supply and fix Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw.
M&L for Earthing complete with copper earth plate 60x60cmx3.15 mm thick electrode and 20x3mm copper strip as earthing lead burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and CI cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc and connected to earthing test point all as specified or directed and testing complete all as specified.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.81 MB
TenderdocumentsT109.pdf
Tender Documents • 1.25 MB
SchofCreditT109.pdf
Additional Documents • 0.42 MB
BOQ_847147.xls
BOQ • 4.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .