| 1 | L1₹1.5 CrAccepted-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹1.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.6 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹1.6 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.6 CrRejected-Finance | ₹1.6 Cr | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | SOOD ASSOCIATES PVT LTD L2 | ASHIRWAD ELECTRICALS L3 | M/S ADHIKARI CONSTRUCTION CO. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Boring of hole for installatin of HT poles /stay shoould be done with earth auger (back up with diesel generator). Auger should be capable to bore in hard rock. the required bore is 250 mm up to depth of 1.98 /1.20meters, complete all as specified & directed.
(Note - PCC Work will measured and paid sepertly) | 140 | EACH JOB | 577 ₹80,780 | 100 ₹14,000 | 299 ₹41,860 |
| 2.00 | Removing surplus excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified & directed. | 12.83 | CUM | 277 ₹3,553.91 | 1,500 ₹19,245 | 79 ₹1,013.57 |
| 3.00 | Supply, installation, testing & commissioning of 11 KV medium voltage covered arial bunched cable line on existing poles if size 3 core x 95sqmm + 1 core of 70 sqmm consisting of all accessories such as terminal box with provision of appropriate earthing system, suspension clamp, anchor clamp, eye hook, cable end cap, suitable tapping arrangements, joints, and jointing materials etc complete all as specified and directed.
Note :
(a) contracot shall submit the design details alongwith sag calculation etc for approval of the accepting officer before commencement of work.
(b) Successful commissioning of the entire system shall be the responsibility of the contractor.
(c) All items and T&P required for successful commissioning shall be deemed to be included in quoted rates.
(d) The cable should be IS: 8130-1984, IS 398(Part-IV)-1994, IS-7098 (part-II) 2011 and IS: 5831-1984 with updated ammendments if any. (e) The HT OH Line passes through 2-3 crossings of State Electricity HT Line. It shall be sole responsibility of the contractor to obtain necessary permissions for the shuydown from the State Electricity Authorities(HESCOM) before execution of the work. (f) Shutdown will be provided between 09.00 AM to 05.00PM to execute the work on present over head line. If Contractor fails to execute the work between 09.00AM to 05.00PM and if any penalty imposed by HESCOM shall be born by Contractor. | 6,600 | RM | 1,217 ₹80.3 L | 1,156 ₹76.3 L | 1,299 ₹85.7 L |
| 4.00 | Supply and fix steel tubular swaged poles type 410 SP-55 (11 Meter long) complete with CI base plate and final including foundation and coping including two coats of Aluminium paint over a coat of Red oxide primer in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, all as directed by Engr-in-charge.complete all as specified & as directed
Note :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid separately. | 120 | EACH | 24,077 ₹28.9 L | 27,900 ₹33.5 L | 21,999 ₹26.4 L |
| 5.00 | Material & Labour for mild steel Cross arms, angles, bracings, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts, in any shape or sizes ,supension clamp, anchor clamp, eye hook, cable end cap, suitable tapping arrangements, joints, and jointing materials etc complete all as specified and directed including painting with two coats of Aluminium paint over a coat of Red oxide primer all as directed. | 36 | QTL | 14,777 ₹5.3 L | 14,400 ₹5.2 L | 12,999 ₹4.7 L |
| 6.00 | Supply & Fix on pole 8.00 mm dia GI wire on the cross arms of HT pole by fixing nut and bolt all as specified and directed. | 19,800 | RM | 67.77 ₹13.4 L | 5 ₹99,000 | 4.99 ₹98,802 |
| 7.00 | Material & Labour for heat shrinkable cable jointing kit for 11 KV earthed grade cable for out door termination complete with jointing materials and accessories suitable for XLPE insulated AB cable 3 core X 95sq mm + 1X 70 sq mm all as directed. | 2 | EACH | 6,077 ₹12,154 | 4,650 ₹9,300 | 4,999 ₹9,998 |
| 8.00 | All as per item No.7 herein before but straight through joint kit for XLPE insulated AB cable 3 core X 95 sq mm + 1 X 70 sq mm all as specified and as directed. | 7 | EACH | 7,077 ₹49,539 | 5,250 ₹36,750 | 4,999 ₹34,993 |
| 9.00 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. Notes
(i) The rate quoted shall be deemed to include for all the above provisions.
(ii). PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) . | 2 | EACH JOB | 6,977 ₹13,954 | 7,500 ₹15,000 | 7,999 ₹15,998 |
| 10.00 | M & L for Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm size burried directly in ground vertically to a depth not less than 2.25 mm below ground level with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth strip 32x6 mm size protected by 40 mm light grade pipe upto 7.5 m length by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 including necessary excavation earth work, drilling of holes for electrode, PCC 1:3:6 type C1, RCC cover slab, 50 mm thick with 1:2:4 type B1, using 8 mm CTD bars 140 mm C/C both- way with suitable handle, watering pipe 20 mm dia light grade GI, funnel, charcoal, salt all as specified and as directed by Engineer in charge including taking down old u/s earthing assembly all as specified and directed. | 4 | EACH JOB | 7,577 ₹30,308 | 7,500 ₹30,000 | 7,999 ₹31,996 |
Updated dates
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
5 Jan 2026, 6:00 pmClosed
Ranjeet Kumar, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIR OF OVERHEAD HT LINE TO ARIAL BUNCH CABLE (ABC) AT ATS BELAGAVI
2025_MES_734985_2
81255/E8
Open Tender
Civil Works
180 days
GE (AF) Sambra
As per Tender Document
8 documents required · 8 mandatory
₹1,000
GE (AF) Sambra
₹2.1 L
Yes
31 Jan 2026
6 Dec 2025
14 Jan 2026
6 Dec 2025
5 Jan 2026
13 Dec 2025
6 Dec 2025 - 9 Dec 2025
Amount
Boring of hole for installatin of HT poles /stay shoould be done with earth auger (back up with diesel generator). Auger should be capable to bore in hard rock. the required bore is 250 mm up to depth of 1.98 /1.20meters, complete all as specified & directed. (Note - PCC Work will measured and paid sepertly)
Removing surplus excavated material to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 M above the starting point, complete all as specified & directed.
Supply and fix steel tubular swaged poles type 410 SP-55 (11 Meter long) complete with CI base plate and final including foundation and coping including two coats of Aluminium paint over a coat of Red oxide primer in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, all as directed by Engr-in-charge.complete all as specified & as directed Note :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid separately.
Material & Labour for mild steel Cross arms, angles, bracings, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts, in any shape or sizes ,supension clamp, anchor clamp, eye hook, cable end cap, suitable tapping arrangements, joints, and jointing materials etc complete all as specified and directed including painting with two coats of Aluminium paint over a coat of Red oxide primer all as directed.
Supply & Fix on pole 8.00 mm dia GI wire on the cross arms of HT pole by fixing nut and bolt all as specified and directed.
Material & Labour for heat shrinkable cable jointing kit for 11 KV earthed grade cable for out door termination complete with jointing materials and accessories suitable for XLPE insulated AB cable 3 core X 95sq mm + 1X 70 sq mm all as directed.
All as per item No.7 herein before but straight through joint kit for XLPE insulated AB cable 3 core X 95 sq mm + 1 X 70 sq mm all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. Notes (i) The rate quoted shall be deemed to include for all the above provisions. (ii). PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner) .
M & L for Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm size burried directly in ground vertically to a depth not less than 2.25 mm below ground level with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth strip 32x6 mm size protected by 40 mm light grade pipe upto 7.5 m length by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 including necessary excavation earth work, drilling of holes for electrode, PCC 1:3:6 type C1, RCC cover slab, 50 mm thick with 1:2:4 type B1, using 8 mm CTD bars 140 mm C/C both- way with suitable handle, watering pipe 20 mm dia light grade GI, funnel, charcoal, salt all as specified and as directed by Engineer in charge including taking down old u/s earthing assembly all as specified and directed.
Material & Labour for stay assembly with complete accessories as shown in electrical plate No. 1 using 20 mm dia stay rod including taking down old stay assembly complete all as specified & directed (loop type isolator, stay clamps, excavation and concrete will be measured and paid separately)
Material & Labour for Galvanised iron stay strand of size 7/4.00 mm complete all as specified & directed
Supply and fix disc insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown on green suitable for HT 11 KV complete including taking out the U/S all as specified and as directed.
Material & Labour for heat shrinkable cable jointing kit for 11 KV earthed grade cable for out door termination complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm 3core comple incl taking down the old burnt joint all as specified.
Material & Labour for heat shrinkable cable jointing kit for 11 KV earthed grade cable for in door termination complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm 3core comple incl taking down the old burnt joint all as specified
Supply and laying, testing and commissioning on fixing or passing through pipes, cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor 11 KV (E) volts grade screened of size 120 Sqmm 3 core.
Material & Labour for providing cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling for poles complete all as specified and directed
Material & Labour for providing cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling for poles complete all as specified and directed
Material & Labour for providing cement concrete PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate) as coping around poles etc complete including necessary formwork and finishing the exposed surfaces even and smooth without using extra cement all as specified and as directed.
Supply, installation, connection, testing and commissioning of outdoor type 11 KV SF6 insulated, 630 Amps rupturing capacity upto 250 MVA, extensible outdoor fixed type (IP67), RMU (Ring maint unit). mannul operated vacuum circuit Breaker having digital type overload and earthfault protection, ammeter, , inside robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank having minimum thickness 2.5+0.5 mm having IP 67 Degree of protection RMU should be provided with internal busbars, as well as earthing. Busbars should be of copper, padlock provisions & complete with all accessories. The RMU shall be type tested for internal arc test of not less than 21KA/1 sec as per IEC62271-200. RMU shall be equipped with site replaceable bushing. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP 54 protection complete all as specified and as directed. Note:- (i) RMU will be installed on suitable PCC foundation as per manufactures drawing. (ii) Cost of PCC /Earth work deemed to be included in the rate quoted complete all as specified and as directed. The unit shall include the following with all necessary standard fittings as required at site.
(a) Vaccum circuite Breaker module should consist of following accessories: (i) 630 Amps Vacuum Breaker module for making and breaking of fault current alongwith Earth Switch of full making capacity. VCB should be capable to bear 40 dead short circuit operation. (ii) Short time current - not less than 21 KA - 1 Sec (iii) Making Capacity 50 KA (iv) Auxiliary contacts - 1NO + 1NC (v) Power frequency withstand voltage - 28 KV (vi) Impulse withstand voltage - 75Kv (vii) Nominal operating gas pressure - 1.3 (minimum) Bar abs. (viii) front cover mechanism - IP 2X
(xi) Cable box for front termination fo the cable suitable upto 3 core 120 Sqmm, 11 KV XLPE cable (xii) Right angle boots (push on type) (xiii) Self Powered Microprocessor based Relay (3 O/C & E/F) with standard settings (xiv) Digital ampear meter with RYB (xv) Suitable site replaceable Cable bushings (xvi) Arc proof cable covers with self interlocking mechanism between doors, earth switch, disconnector & VCB (xvii) Capacitive voltage indication fixed type system (xviii) Mechanical indications for breaker ON, OFF, Earth, TRIP, Spring Charged-Discharged. (xix) CT of suitable ratio . (xx) PT of suitable size for voltage display.
(b) (i)-Microprocessor based IDMT (50, 50N, 51, 51N) relayfor overcurrent, short circuit and earth fault protection. (ii) one 1 nos Vacuum Circuit Breakers (VCB) as incomer & 5 nos Vacuum Circuit Breakers (VCB) as Out going along with metering panel (Configuration : VVV+VVV+M) (iii) - 1 NOS incoming Cable support bus bars,and standard for 5 way out unit. (iv) - 1 Set Bushings for external busbar connection along with Busbar cover & Sleeved busbars for coupling. (v)2x12 v DC,12AH battery bank with charger-1NOS
(c) Necessary interlocking arrangement for safety and operations (d) One No. Operation Handle for Manual Operation (e) One No. Manometer. (f) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (g) Above switchgear shall confirm to all relevant IEC/IS Standards. (h) Manual operation of Vacuum Circuit Breaker. (i) Coupling of RMU and Metering module should be with the help of Bolted type arrangement, so that the coupling at site shall be easy. Plug-in type bushing shall not be acceptable. (j) All cable bushing should be replaceable type. (k) Module should be accommodated as per manufacture's design.
SOOD ASSOCIATES PVT LTD (BID ID -3510809)
ASHIRWAD ELECTRICALS (BID ID -3516504)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
81255Tender.pdf
Tender Documents • 2.77 MB
BOQ_832387.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid