| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.1 LAccepted-AOC | L-1 | Accepted-AOC FOUND LOWEST AND REASONABLE | |
| 2 | L-2₹25.0 L+₹40,450 (1.65%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L-2 | Rejected-Finance Being other than lowest | |
| 3 | L-3₹26.6 L+₹2.0 L (8.26%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L-3 | Rejected-Finance Being other than lowest | |
| 4 | L-4₹28.0 L+₹3.4 L (13.8%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L-4 | Rejected-Finance Being other than lowest | |
| 5 | L-5₹29.4 L+₹4.8 L (19.6%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L-5 | Rejected-Finance Being other than lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
30 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) TECHA AREA AGRA
GE (AF) TECHA AREA AGRA
REPAIR /MAINT OF TARMAC LIGHT, SECURITY LIGHT AND HIGHMAST LIGHTS AND CONNECTED ITEMS IN ZONE B TECH AREA UNDER GE(AF) TECH AREA AT AF STN AGRA
2021_MES_486147_1
8200-1371/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TECHA AREA AGRA
As per NIT
10 documents required · 10 mandatory
₹500
GE (AF) TECHA AREA AGRA
₹84,000
Yes
19 Mar 2022
3 Nov 2021
2 Dec 2021
3 Nov 2021
30 Nov 2021
17 Nov 2021
3 Nov 2021 - 9 Nov 2021
60 days
Amount
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and as directed.
Returning & filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soil complete all as specified and as directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and as directed.
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and as directed.
Labour only for re-laying of old serviceable bricks retreived from Item No. 1 here-in before for cable protection cover, laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and as directed.
M&L for local sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm thick sand laid before laying the cable and 150 mm thick sand after laying the cable complete all as specified and as directed. Note : Thickness of sand after punning will be measured for payment purpose.
Taking out old serviceable/ unserviceable LT UG cables of any size of 10 to 70 sq mm, 2/3.5/4 core from trenches, poles/walls and floor includuing taking out old serviceable bricks from trenches complete all as specified and as directed.
Laying only serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes laid in trenches or fixed on walls/floor/pole including testing, commissioning complete all as specified and as directed.
(a) 10 sqmm to 70 Sqmm 3.5/4 core
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles including testing, commissioning complete all as specified and as directed.
(a) 10 Sq mm 4 core
(b) 16 Sq mm 4 core
(c) 25 Sq mm 4 core
(d) 35 Sq mm 3.5 core
(d) 50 Sq mm 3.5 core
M&L for jointing kit suitable for LT 1100 volts cable (earthed) for out door straight through joint, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
(a) 25 to 50 Sqmm 3.5/4 core
(b) 70 to 120 Sqmm 3.5 core
M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for out door, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
(a) 10 to 50 Sqmm 3.5 core
(b) 70 to 120 Sqmm 3.5 core
S&F Security light bracket made out of GI pipe 40 mm dia, light grade for mounting, bracket bent to shape 1.50 RM including suitable clamps made out of flat iron 32x6mm -(04 Nos) 02 Sets nut bolt including painted with two coats of aluminium paint over a coat of red oxide primer and with and including all fixing arrangement complete all as specified and as directed.
Taking down carefully unserviceable LED street light, flood light fitting upto 250 watts of any type from pole/wall/High mast dismantling and checking out serviceability of parts/circuit such as drivers, MCPCB etc repalcement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including connecting, testing complete all as specified and as directed. Note : New parts will be measured and paid separately under relevant items of BOQ as 'supply only'.
Supply only driver suitable for LED Security light 25/30 Watt complete all as specified and as directed.
Supply only driver suitable for LED Security light 45/60 Watt complete all as specified and as directed.
Supply only driver suitable for LED Flood light 90/120/150 Watt complete all as specified and as directed.
Supply only driver suitable for LED Flood light 200/250 Watt complete all as specified and as directed.
Supply and fix in repair LED landscape light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame , IP-65, 25 watt LED for gates with and including all fixing arrangements complete all as specified and as directed.
Supply and fix in repair LED road way light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame IP-66, 30 watt LED complete all as specified and as directed.
Supply and fix in repair of LED road way light fitting luminaires ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame , IP-65, 45 watt LED with 110LM/W complete all as specified and as directed.
Supply and fix in repair of LED road way light fitting luminaires ,comprising of epoxy powder coated housing ,enclosed with glass cover in frame , IP-66, 60 watt LED with SPD 10 KV , efficiency 110LM/W complete all as specified and as directed.
Supply and fix in repair LED flood light fitting suitable for fixing on wall/bldgs/tarmac lights with and including all fixing arrangements high grade aluminium pressure die cast and toughened glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 120 watt complete all as specified and as directed.
Supply and fix in repair LED flood light fitting suitable for wall/bldgs/tarmac lights with and including all fixing arrangements, high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 150 watt complete all as specified and as directed.
Supply and fix in repair LED flood light fitting suitable for high mast light with and including all fixing arrangements high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 250 watt complete all as specified and as directed.
Taking out lantern carriage of high mast light fitting with the help of integral power tools for repair and maintenance of unserviceable parts of any capacity and type with and including replacement of defective parts to be replaced with new parts and make the fittings serviceable complete all as specified and directed.
Supply and fix in repair LED aviation obstruction light in red colour with 48 W capacity by lowering the lantern with and including removing the old light and refixing the new one and raising the lantern in same position with coonected accesssories complete all as specified and as directed. (Make :Bajaj model no-110731 or equivalent and approved in specified makes)
Supply and fix copper conductor of size 5core, 2.5 Sqmm rubber insulated and cotton braiding over the laid up cores PVC sheathed flexible type for highmast trailing rubber cable with and including removal of old cable and reconnecting with proper size of thimble and connected accessories complete all as specified and directed.
Supply and fixing stainless steel wire rope grade- AIAI 304, 7/19 constructed out of dia 6mm with breaking load capacity as per standred norms for highmast including removal of old wire rope and reconnection with proper connected accessories complete all as specified and directed.
Supply and fix three phase motor of capacity 1 HP with reverse and forward moving ,6 pole single speed suitable for high mast complete all as specified and directed.
Supply and fixing in repair winch/power tool double drum type/350 Kg with connected accessories suitable for lowering and raising the highmast lantern including disconnection of old winch/power tool and refixing of new with connected accessories complete all as specified and directed.
S& F in repair Diamond chain B.S (I) 3/8 suitable for highmast motor roatation with connected accessories including taking down old sprocket and replaced with all fixing arrangment complete all as specified and directed.
S& F in repair sprocket 3/8 with Hub TH-14 heavy duty suitable for highmast motor and roatary part with connected accessories including taking down old sprocket and replaced with all fixing arrangment complete all as specified and directed.
M & L for repair of control panel of high mast light fitting complete with and including checking all electrical wiring and contactor including removing old burnt control wiring from the Panel and re-wiring with new PVC insulated copper cable single core multi strand with existing size and make the panel serviceable including testing after completion of work complete all as specified and directed.
Supply and fixing MCB FP 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
Supply and fixing MCB SPN 6 to 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box with 4 aluminium strip bar(25x3 mm) , having protection class IP-65 and of overall size 205mm x 255mm x 112mm having metric knockouts on the wall, having three phase cable connecter, duly fixed with the pole with clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB complete all as specified and as directed.
S&F in replacement control panel outdoor type size 500x775x250 made out of 14 SWG CRCA sheet with, IP-55, with and including iron stand (made out of 40x40x5mm MS angle) mounted feeder piller with and including aluminium busbar-4 nos 63 A internal wiring with 6 Sqmm copper wire for 32A circuit and 2.5 Sqmm for others. Complete for automatic, timely Off/On for operating 6 to 10 Nos) 250 watt LED light fitting Comprising of following accessories complete all as specified and as directed. (i) incoming 32 A 4pole MCB isolater- 01 no. Make- siemens/ABB/L&T(ii) 22A TP Contactor- 01 No.Make- siemens/ABB/L&T (iii) 9A contactor- 02 nos. Make- siemens/ABB/L&T(iv) single dial timer switch - 01 no. Make- L&T (v) push button- 02 No. (vi) Outlet Terminal- 02 nos. (vii) Toggle switch- 01 no (viii) Neutral link- 01 no (ix) Glass fuse- 01 no
Repair/Maintenance winch/power tool double drum type/350 Kg suitable for lowering and raising the highmast lantern including dismantling of winch/power tool and refixing after repair with connected accessories complete all as specified and directed.
M&L for re-winding of existing highmast three phase motor of capacity upto 1.5 HP with reverse and forward moving ,6 pole single speed suitable for high mast including dismantling of motor and refixing after rewinding in same position with connected accessories complete all as specified and directed.
Repair & maintainenace three phase motor of capacity 1 HP with reverse and forward moving ,6 pole single speed suitable for high mast with and including dismantling of motor and refixing after repair/servicing in same position with connected accessories complete all as specified and directed.
Supply and fixing nature switch complete with timer , contactor, relays and suitable rating MCB s for incoming and out going in built in suitable sheet metal enclosure of single phase integrated models of capacity 8 KW including taking down/out old unserviceable nature switch complete all as specified and directed. Make : Cat Part No. SWADEEP-02 EC 8kW 1P of Healer Enterprises or equivalent as approved by GE)
M&L for MS sections fabricated from structural steel sections holding nut, bolts and washers including necessary welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L Painting to existing LT Panels, angle iron support bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Preparation of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint from 1.5 mtr above ground level to top of pole and making alternate strips/layers (30 cm wide) with white and blue synthetic enamel paint upto the 1.50 meter height from the ground level including writing the pole number in white letters on black background and cleaning/cutting the grass/bushes at a radius of 2 mtr surrounding the pole complete all as specified and directed.
M & L Painting to existing light pillar with two coats of synthetic enamel paint of superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
M&L for Copper bus bar chamber of following sizes/ capacities, fixed on insulator welded with angle iron of size 50x50x6 mm thick grouting in floor, 450 mm depth grouting with PCC (size 450x450x300 mm)1:3:6 type C-1 using 40mm graded aggregate upto ground level and 600 mm high above GL complete all as specified and as directed.
(a) 200 Amps copper bus bar 04 Nos
(b) 100 Amps copper bus bar 04 Nos
Demolition of PCC/Black Bituminous road of any description and in any position not otherwise specially provided etc complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using 40 mm gradded stone aggregate for foundation of poles, panel board etc complete all as specified and as directed.
S & F in repair cage for protection/housing LED lights made out of 4mm dia GI wire along with suitable size of angle iron frame fixed on foundation with necessary anchor fastner and nut bolts etc complete the size of cage should be 550x450x550 mm including one side with cage opening and locking arrangement and painted with black super enamle paint over a coat of red oxide primer etc complete all as specified and directed.
Material & labour for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6.00mm thick burried directly in ground vertically at a depth not less than 3.75 metre below normal ground level with top edge of earth plate shall be at a depth not less than 3.25 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 30 x 5 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40 mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75 centre to centre both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus spoil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed. Note : Cost of earthing strip and protection pipe upto lenght of 7.5 m shall deemed to be included in quoted rate.
Carryout day to day rectification of external electrical complaints such as repair, reconnection and lightening of burnt/loose cable lead in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed.
Note : (a) 01 x Electrician and 01 x helper will be detailed by the contractor for attending above complaints on daily basis cost for which shall be deemed to be included in quoted rate. (b) Replacement of major items shall be measured and paid under relevant items of this schedule. (c) Electrician and helper so detailed by the contractor will report to MES complaint cell at 0900 hrs morning to receive complaint slip from department and complaints shall be rectified within 08 hours. If contractor fails to detail above tradesmen, a panel recovery @ Rs 500.00 per day shall be made to the contractor and the same shall be recovered from RAR/final bill. (d) Repairing upto 03 points at different electrical system without any other material will be considered as one job.
Unnati Engineers
M/s Sumer Associates
GUPTA ENGINEERING WORKS
MUKTA AND COMPANY
Star Enterprises
M/s S.M. Construction
Industrial Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .