OFFICE OF THE EXECUTIVE ENGINEER EDIV KHANYAR
OFFICE OF THE EXECUTVIE ENGINEER EDIV
Erection of 11 KV line on 9 mtr ST pole using 100mm ACSR conductor and erection of LT line on 8 mtr ST pole including sub station renovation /up gradation and dismantling of old structure .
2023_PDD_238569_1
EDIV/15 OF 2023-24
Open Tender
Electrical and Maintenance Works
Turn-key
14 days
KHANYAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
EXECUTIVE ENGINEER EDIV KHANYAR
₹4.4 L
Yes
13 Jan 2024
2 Dec 2023
27 Dec 2023
2 Dec 2023
26 Dec 2023
4 Dec 2023
4 Dec 2023 - 4 Dec 2023
Supply, installation, testing and commissioning of: Sub Station
Providing ,Loading , unloading at site Installation Testing Commissioning of 9 Mtr. Long Pole, ST-410 SP33
Providing of Cement bottoming 1:2:4 mix as per Standards 0.5 cum per pole complete with material & labour
Supply , fixing of 11 kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply , fixing of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply , fixing of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type.
Supply, Installation, Testing, Commissioning ,ofLT Distribution Box for i). 400 kVA DTR with 630 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits
Supply,installation,Testing and commissioning of LT Distribution Box for 630 kVA DTR with 1000 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 250 Amp MCCB 3 P (25 KA) 2 No.s fixed & 200 Amp MCCB 3 P (25 KA) 3 No.s for Out going. Circuits
Supply , fixing testing and commissioning of 400 mm² , single core aluminum Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Supply , fixing testing and commissioning of 300 mm² single core aluminum Cable Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing testing and conmmissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing and fixing of Sundry items like aluminium lugs, Jumpers, binding Tape,
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Supply , fixing of GI Channel X-arm including clamps and braces ( fibricated out of 100X50X50X8 MM,75x40x40x 6 mm with top Bracket including clamp fibricated out of 50x 8 mm flat GI Strip for HT Line
Supply , fixing of GI Channel X-arm including clamps and braces ( fibricated out of 100X50X50X8 MM,75x40x40x 6 mm with top Bracket including clamp fibricated out of 50x 8 mm flat GI Strip forSub transformer bedding
Supply , fixing, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply , fixing, testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, installation, testing and commissioning of: HT
Supply Loading , unloading at site,laying , Installation testing and commissioning of 100 mm² ACSR Conductor
Supply and fixing of Aluminum jointing sleeves
Supply ,Loading , unloading at site Installation Testing Commissioning of 11 Mtr. Long Pole, ST-410 SP56
Supply ,Loading , unloading at site Installation Testing Commissioning of 9 Mtr. Long Pole, ST-410 SP33
Providing of Cement bottoming 1:2:4 mix as per Standards 0.5 cum per pole complete with material & labour
Providing of Cement bottoming 1:2:4 mix as per Standards 0.6cum per pole complete with material & labour
Supply,fixing ,testing & comissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Supply , fixing of GI Channel X-arm including clamps and braces ( fibricated out of 100X50X50X8 MM,75x40x40x 6 mm with top Bracket including clamp fibricated out of 50x 8 mm flat GI Strip for HT Line
Supply , fixing , testing and commissioning of PG Clamps for 100 mm² ACSR Conductor
Supply , fixing, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply , fixing, testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, installation, testing and commissioning of: LT
Supply Loading , unloading at site,laying , Installation , fixing ,testing and commissioning of 100 mm² ACSR Conductor
Supply Loading , unloading at site,laying , Installation testing , fixing and commissioning of 50 mm² ACSR Conductor
Supply, Installation, testing and commissioning of LT Shackle Insulator
Supply ,Installation, testing and commissioning of LT mukki clamps fabricated out of 50x 8 mm flat GI ( at least 2.5 Kg Each)
Supply and fixing of Aluminum jointing sleeves
Supply ,Loading , unloading at site Installation Testing Commissioning of8Mtr. Long Pole, ST-410 SP15
Providing of Cement bottoming 1:2:4 mix as per Standards 0.45 cum per pole complete with material & labour
Supply,fixing ,testing & comissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Supply, installation, testing and commissioning of:
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar 100,50,30 mm² ACSR Conductor
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar Pcc poles
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar wooden pole poles
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar LT Shackle Insulator
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar ST 8 Mt/ 9 Mt poles
Dismentellin, of stone masonary / wooden Sub-station bed and Stacking , carriage up to Divisional Strores Khanyar the red material
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar 11 Kv pin insulators with pindscomplete
Dismentellin, Stacking , carriage up to Divisional Strores Khanyar 11 Kv disc set complete
MS WASEEM ENTERPRISES
BLUEWAVE ENGINEERS & CONTRACTORS
LONE ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .