GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
REPAIR / MAINT WORK OF VARIOUS TYPE OF PUMP, MOTORS, CHLORONOME PLANTS, PLENARY MAINTENANCE OF DOZING PUMP, STARTER, PANEL BOARD AND CONNECTED WORK OF NEW CANTT UNDER GE WEST PRAYAGRAJ
2024_MES_666470_1
8754/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹96,000
Yes
29 Oct 2024
18 Jul 2024
20 Sept 2024
18 Jul 2024
12 Sept 2024
1 Aug 2024
Amount
S&F High pressure single head chemical dosing system. power input 230V, 50Hz, 40 SPM, 1/30 fractional horse power, pressure 5kg/ Sqcm, max output 6.5 ltr with accessories like lead tubing, connecting ferrule, check valve, preparation tank model AQUA1005 of net capacity 170 ltrs FRP dosing tank dia 650 x net height 375+ conical 300 mm, gross height with stranded 1000mm consisting of water inlet line, outlet strainer, drain, overflow, conical bottom of sludge deposition, pot hole with cover, Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller complete all as specified & directed. Note - Provide one service tank of capacity -100 Ltr , and mixing tank capacity of 170 Ltr both tank with aviator motor complete all as directed , and making electric connection and testing complete to entire satisfaction of Engr-in-charge .
Taking out centrifugal pump including electric motor 3 to 5 HP, 3 phase, 415 Volts after disconnecting the electric connection, dismantling the motor, cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with super enamelled copper wire (Gauge of copper is to match the existing size) with insulating material, varnishing complete. Reassembling the motor, repair and overhauling of pumps, replacement of bearing, grinding, polishing of impeller, necking ,greasing complete all as directed and making electric connection and testing complete to entire satisfaction of Engr-in-charge
Taking out centrifugal pump including electric motor 7.5 to 10 HP, 3 phase ,415 Volts after, disconnecting the electric connection. Dismantling the motor .Cutting the burnt winding and cleaning the slots with non greasy materials and rewinding with super enamelled copper wire (Gauge of copper is to match the existing size) with insulating material, varnishing complete. Reassembling the motor, repair and overhauling of pumps, replacement of bearing, grinding , polishing of impeller, neck ring ,greasing complete all as directed , and making electric connection and testing complete to entire satisfaction of Engr-in-charge
S&F 100mm bore sluice valve, heavy duty both ends flanged class PN-I with high tensile brass spindle cast iron head operated wheel and cap top, nuts and bolts, washers including 3mm thick rubber gasket joint including taking down old unserviceable valve complete all as specified and directed.
S&F 150mm bore sluice valve, heavy duty both ends flanged class PN-I with high tensile brass spindle cast iron head operated wheel and cap top, nuts and bolts, washers including 3mm thick rubber gasket joint including taking down old unserviceable valve complete all as specified and directed.
S&F in replacement 100mm bore cast iron non returning valve, heavy duty both ends flanged, with high tensile brass spindle, cast iron head operated wheel and cap top, nuts, bolts and washers including 3mm thick rubber gasket joint complete all as specified and directed.
S&F in replacement 150mm bore cast iron non returning valve, heavy duty both ends flanged, with high tensile brass spindle, cast iron head operated wheel and cap top, nuts, bolts and washers including 3mm thick rubber gasket joint complete all as specified and directed.
Comprehensive Fortnightly maintenance of Chlorine dosing plants installed at various installations ( Total Number of Pump Houses -16 ) of GE (West) New cantt Allahabad comprising of the following:- (a) Checking of all parts for functional aspects of dosing plants such as checking of valve, checking of gauge etc and making the plant functional for operation also by arresting any kind of leakage/ blockage of plants any time any location under GE (West) Allahabad area, the work will be done by skilled mechanic and other minor parts not specifically maintained shall also be replaced where required for proper functioning along with safety equipment complete all as specified and directed.
Disconnecting and taking out the UNSV 120 Watts agitator motor 960 RPM single phase 230 volts complete and rewinding with copper enemelled wire of suitable gauge, replacement of bearing ,brackets and tolerance rings suitable for agitator including refixing complete all as specified and directed.
S&F in replacement of gun metal gate valve 15 mm size ISI marked with iron wheel head, screwed both end for iron pipe complete all as specified and directed
Supply only spacer of 1/2 HP capacity chemical dosing pump complete all as specified and directed.
Supply only spacer gasket of 1/2 HP capacity chemical dosing pump complete all as specified and directed.
Supply only piston of 1/2 HP capacity chemical dosing pump complete all as specified and directed.
Supply only gear plate of 1/2 HP capacity chemical dosing pump complete all as specified and directed.
Supply only diafram of 1/2 HP capacity chemical dosing pump complete all as specified and directed.
Dismantling and taking out defective unserviceable butterfly valve and replacement with new butterfly valve 65 mm bore including jointing with MS nuts, bolts packing, minor adjustment complete all as specified and directed.
Dismantling and taking out defective unserviceable butterfly valve and replacement with new butterfly valve 80 mm bore including jointing with MS nuts, bolts packing, minor adjustment complete all as specified and directed.
Supply only sodium hypo chloride solution in 50 litre packing each container PVC of strength 10 to 12% complete all as specified and directed. Make: Hybrid or as approved. NOTE: Bulk supply of solution to be taken on charge through receipt voucher and to be issued through issue voucher based on specified daily consumption.
Supply only 1/2" hypo pump outlet NRV complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only 1/2" hypo pump inlet NRV complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only 1/2" NRV between hypo pump outlet and main line complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only digital timer XT-246, 220 volt AC complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only CPVC MTA 1/2" complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only CPVC FTA 1/2" complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only CPVC union complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only drain valve complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only flow guard gold complete all as specified and directed. Make: RMCO/ VARIMA/ Prestine.
Supply only PVC dosing pipe 10mm dia complete all as specified and directed. Make: Vardhman or equivalent as approved.
Repair and maintenance of LT panel/ star delta panel at water supply installation including provision of necessary PVC insulated copper wire, lugs, bushes, insulating material including necessary re-wiring with suitable size copper conductor complete all as specified and directed. NOTE: Spare parts of shall be measured and paid separately under respective item of schedule.
Supply only 4 pole power contactor Type-ML of rating 63/70 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only 3 pole power contactor Type-ML of rating 45/50 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only 2 pole power contactor Type-ML of rating 32 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only star delta timer ET-100 complete all as specified and directed.
Supply only Over Load Relay of capacity 28-50 Amp complete all as specified and directed.
Supply only Over Load Relay of capacity 45-75 Amp complete all as specified and directed.
Supply only Starter/stop push button complete all as specified and directed.
Supply only Single Phasing preventer VSP-3 complete all as specified and directed. Make: Minilec or equivalent as approved.
Supply only indicator LED type R, Y, B complete all as specified and directed.
S & F in replacement of MCCB, 4 pole, 415 volts, 50 Hz, rated current 100 Amp, breaking capacity 25 KA, with thermal and magnetic release complete all as specified and directed.
S & F in replacement of MCCB, 4 pole, 415 volts, 50 Hz, rated current 160 Amp, breaking capacity 35 KA, with thermal and magnetic release complete all as specified and directed.
Repair, overhauling and testing of existing Starter panel board of any size and type including cleaning with compressed air, tightening of all electric connections to switches including replacement of MCB and switch fuse disconnector units each of any rating, opening and refixing of doors with proper locking arrangement, replacement of wornout lugs, nuts, bolts, internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire and connection to main earth lead and spray painting with synthetic enamel paint of light grey shade in outer/ inner side of panel after cleaning and preparing surface including sign writing complete all as specified and directed. NOTE: Spare parts of shall be measured and paid separately under respective item of schedule.
Supply only 4 pole power contactor MNX 16 of rating 16 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only 3 pole power contactor MNX 22 of rating 22 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only 3 pole power contactor MNX 25 of rating 25 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only 3 pole power contactor MNX 32 of rating 32 Amp for star delta starter/ LT panel complete all as specified and directed.
Supply only PVC connector complete all as specified and directed.
Supply only Over Load Relay of capacity 20-30 Amp complete all as specified and directed.
Supply only Over Load Relay of capacity 10-20 Amp complete all as specified and directed.
Supply only MCB Triple Pole and neutral, 63 Amps 415 volts, 10KA breaking capacity, convenient to 'C' Curve complete all as specified and directed.
Supply only MCB Triple Pole and neutral, 32 Amps 415 volts, 10KA breaking capacity, convenient to 'C' Curve complete all as specified and directed.
Taking out burnt/ unserviceable submersible pump set suitable for MS column pipe 100 mm bore from 35 to 40m below ground level complete all as specified and directed.
Lowering of submersible pump set after necessary repair and rewinding suitable for MS column pipe 100 mm bore including replacement of rubber packing, nuts, bolts, washers and cable connection with suitable size copper conductor complete all as specified and directed.
Taking out burnt/ unserviceable submersible pump set suitable for MS column pipe 150 mm bore from 35 to 40m below ground level complete all as specified and directed.
Lowering of submersible pump set after necessary repair and rewinding suitable for MS column pipe 150 mm bore including replacement of rubber packing, nuts, bolts, washers and cable connection with suitable size copper conductor complete all as specified and directed.
M&L in replacement of MS column pipe, 100mm bore and 5.4 mm thick, each 3 RM long including lowering, making threads and provn of MS Flange, cutting of Slot 3 Nos. in each flange, welding of flanges complete all as specified and directed.
M&L in replacement of MS column pipe, 150mm bore and 5.4 mm thick, each 3 RM long including lowering, making threads and provn of MS Flange, cutting of Slot 3 Nos. in each flange, welding of flanges complete all as specified and directed.
Taking out submersible pump set from column pipe of 40 HP capacity including disconnection of all electrical connections with all fittings for repair and transportation from site to workshop situated at local city for necessary repair/rewinding by cutting the burnt winding coils and cleaning the slots with non greasy materials and rewinding with PVC insulated copper wire as per existing size with insulating material complete reassembling the motor and back after repair and lowering and refixing of pump set with MS column pipe of 150 mm bore in bore well, including provision of replacement of all minor parts like rubber packing, nuts, bolts etc and reconnecting all electrical connection and including replacement of 16 Sqmm 3 core PVC insulated flat submersible cable and testing complete all as specified and directed.
Taking out submersible pump set from column pipe of 35/33 HP capacity including disconnection of all electrical connections with all fittings for repair and transportation from site to workshop situated at local city for necessary repair/rewinding by cutting the burnt winding coils and cleaning the slots with non greasy materials and rewinding with PVC insulated copper wire as per existing size with insulating material complete reassembling the motor and back after repair and lowering and refixing of pump set with MS column pipe of 150 mm bore in bore well, including provision of replacement of all minor parts like rubber packing, nuts, bolts etc and reconnecting all electrical connection and including replacement of 10 Sqmm 3 core PVC insulated flat submersible cable and testing complete all as specified and directed.
Taking out submersible pump set from column pipe of 20/25 HP capacity including disconnection of all electrical connections with all fittings for repair and transportation from site to workshop situated at local city for necessary repair/rewinding by cutting the burnt winding coils and cleaning the slots with non greasy materials and rewinding with PVC insulated copper wire as per existing size with insulating material complete reassembling the motor and back after repair and lowering and refixing of pump set with MS column pipe of 150 mm bore in bore well, including provision of replacement of all minor parts like rubber packing, nuts, bolts etc and reconnecting all electrical connection and including replacement of 10 Sqmm 3 core PVC insulated flat submersible cable and testing complete all as specified and directed.
M&L for developing of bore well by means of 300 PSI air compressor and high velocity jet complete all as specified and directed.
S & F in replacement of CI Impeller for the pump of capacity 30 to 40 HP complete all as specified and directed.
S & F in replacement of bearing for the pump of capacity 30 to 40 HP complete all as specified and directed.
S & F in replacement of thrust bearing for the pump of capacity 30 to 40 HP complete all as specified and directed.
S & F in replacement of seal for the pump of capacity 30 to 40 HP complete all as specified and directed.
S & F in replacement of bowl assembly for the pump of capacity 30 to 40 HP complete all as specified and directed.
S & F in replacement of CI Impeller for the pump of capacity 30 to 40 HP complete all as specified and directed.
S & F in replacement of bearing for the pump of capacity 20/25 HP complete all as specified and directed.
S & F in replacement of Thrust bearing for the pump of capacity 20/25 HP complete all as specified and directed.
S & F in replacement of seal for the pump of capacity 20/25 HP complete all as specified and directed.
S & F in replacement of bowl assembly for the pump of capacity 30/40 HP complete all as specified and directed. NOTE: (i) All supply materials ( Srl Item Nos 63 to 72) shall be taken on ledger charge through receipt. (ii) Contractor shall submit purchase voucher of all supply materials along with supply as required by Engr-in- charge.
M&L for MS flanged reducer suitable for 150x100mm bore pipe including jointing with rubber gasket, MS nuts, bolts and washers complete all as specified and directed.
M&L for MS flanged reducer suitable for 100x80mm bore pipe including jointing with rubber gasket, MS nuts, bolts and washers complete all as specified and directed.
M&L for non return valve 100 mm dia for pump including jointing with rubber gasket, MS nuts, bolts and washers complete all as specified and directed.
Supply, jointing and testing of flat submersible cable PVC insulated PVC sheathed copper conductor of 25 sqmm 3 core complete all as specified and directed.
Supply, jointing and testing of flat submersible cable PVC insulated PVC sheathed copper conductor of 16 sqmm 3 core complete all as specified and directed.
Supply, jointing and testing of flat submersible cable PVC insulated PVC sheathed copper conductor of 10 sqmm 3 core complete all as specified and directed.
M&L in replacement DOL starter three phase 415 volts suitable for 5 to 7.5 HP motor including connection and fixing complete all as specified and directed. Make: Havells/ Indoasian/ Crompton
M&L in replacement DOL starter single phase 230 volts suitable for 3 to 5 HP motor including connection and fixing complete all as specified and directed. Make: Havells/ Indoasian/ Crompton
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connected to GI earth wire 4mm dia (7.50m) by means of bolts, nuts, check nuts & washers of galvanised iron or steel, earth lead wire protected by 15mm dia GI pipe light grade, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as SSR Item No. 19471 and shown in electrical plate No. 3 of SSR part-I with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as shown in electrical plate No 5 of MES schedule Part-I and as specified and directed.
S&F in replacement 20 HP submersible pump with motor 2800 RPM single phase 230 volt complete all as specified and directed. Make: KSB/ CG.
S&F in replacement 30 HP horizontal submersible pump with motor 2800 RPM single phase 230 volt complete all as specified and directed. Make: KSB/ CG.
Disconnecting the electric motor of capacity 2 HP to 30 HP, 3 phase, 415 volts 50 C/S with booster pump of any make from the set, rewinding the stator coil with super enamelled copper winding wire of existing gauge and size including all winding/ insulating material, reassembling and re-fixing the same with true alignment, testing and commissioning complete all as specified and directed.
Disconnecting the DSM pump of 2 HP to 30 HP capacity and repair pump impeller, shaft, bush and bearing including melt work, grinding and gland packing as required for smooth functioning of pump complete all as directed.
M&L in replacement star-delta starter three phase 415 volts suitable for 10 to 12.5 HP motor including connection and fixing complete all as specified and directed
Material and labour for packing pea gravel of size 2.00x 4.00 mm natural shape brought directly from river bed and packing around casing pipe to entire depth upto ground level all as specified and directed.
S&F in replacement Aviation Obstruction light with LED lamp with all accessories complete all as specified and directed. Make: Bajaj cat No. BGAV302LED or equivalent in Havells/ Crompton/ Philips.
M&L for two core 1.5 sqmm copper conductor cable for connecting up aviation light to main switch complete all as specified and directed.
S&F in replacement of 6 mm thick MS plate chequered plate including welding / grinding to make in shape complete all as specified and directed.
S&F in replacement of 6 mm thick MS Angle / flat iron/ MS bar including welding / grinding to make in shape complete all as specified and directed.
M&L Sodium hypo chloride (NaCIO) granular 65% packed in 45/50 Kg drum Used as dysfunctioning agent in pump house for dysfunction of water complete all as specified and directed.
M&L in replacement of Deep Bag Net of polypropylene and white polyester netting with 1.5" butterfly nut / clip connection and suitable to trap deep pool larger sediments complete all as specified and directed.
Supply, installation, commissioning and testing in replacement of indoor type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears. The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate )
(i) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 100 Amp - 01 No(iii) Star delta starter comprising suitable size of 3 pole contactors for 40 HP submersible pump with thermal over load relay complete - 01 No(iv) Motor protection relay for single phase, over load, over voltage (v) Digital Volt meter 0-500 volts(vi) Ammeter 0-500 amps with suitable size of CTs (vii) All connections to be done through suitable size PVC insulated copper cables(viii) LED RYB indicator - 01 Set(ix) MCB' TP 32 Amps 10 KA - 01 No (X) MCB SPN 32 Amps 10 KA - 01 No(xi) Single phase preventer - 01 No
Schedule of Credit (MINUS) Rs. 253295.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
M/S SHIV BALLABH MISHRA (BID ID -3092622)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .