Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2 L
EMD Value
₹4,000
Closing Date
11 Apr 2023, 6:55 pmClosed
SE EDC CHITRAKOOT
DWARIKAPURI KARWI CHITRAKOOT
Work of difference place 33 KV Line Maintenance Repair at smooth supply in summer period and other work under EDD-Rajapur
2023_DVVNL_795172_1
40/SE/EDCCKT/2022-23
Open Tender
Electrical Works
Piece-work
180 days
KARWI CHITRAKOOT
Work of difference place 33 KV Line Maintenance Repair at smooth supply in summer period and other work under EDD-Rajapur
2 documents required · 2 mandatory
₹1,180
www.dvvnl.org
₹4,000
16 Apr 2023
6 Apr 2023
12 Apr 2023
6 Apr 2023
11 Apr 2023
6 Apr 2023
Cartage of Pole & material from store centre from any other place to the respective site of work through the Kachha Pacca road inclading the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work.
11 MTR ST Pole
9.0 MTR PCC Pole
8.5 MTR PCC Pole
33 KV V Type Cross Arm 100X50X6MM
33 KV Cross Arm Holding Clamp with Nut&Bolts
33 KV Pin Insulators With Pin
33 KV Disc Insulators With Fitting
F-Bracket For 33 KV
F-Clamp For 11 KV
Stay Set Complete
Earthing Set Complete
Gaurding Angle
GI Wire 6SWG
11 KV Pin Insulators With Pin
Shakle Insulators
Dropper Channel 100X50X2040 mm With clamp With Nut$ Bolts
MS Base Angle 75X75x8mm 2028 Long With clamp With Nut$ Bolts
MS Top & Dropper Channel With clamp With Nut$ Bolts
Piercing Connector
J-Hook with Clamp
Dead End Clamp
AB Cable(3X120+1X50+1X16)Sqmm
AB Cable(3X95+1X50+1X16)Sqmm
3.5X150MM LT PVC Cable
A.C.S.R. WEASEL Conductor
63 KVA New T/f
Erection of Single support 11 MTR ST Poles including complete. H.T/L.T fittings as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Single support 9.00 MTR PCC Poles including complete. H.T/L.T fittings as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Single support 8.5 MTR PCC Poles including complete. H.T/L.T fittings as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support 11 ST Poles as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support 9.00 MTR PCC Poles as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support 8.5 PCC Poles as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection and Grouting of Stay Set including the work of nozelling etc. as per RESPO manual and also including the cost of all grouting material, labour, T&P etc required for proper completion of work.
Fixing & Commisioning of 33 KV V Type Cross Arm 100X50X6MM per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of 33 KV Cross Arm Holding Clamp per norms complete in all respect as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of 33 KV Pin Insulators With Pin as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of 33 KV Disc Insulators as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of 11 KV Pin Insulators With Pin as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Shakle Insulators as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of F-Bracket For 33 KV as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of F-Clamp as per RESPO manual and as per direction of Engineer In charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S. Earthing Rod Complete as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S.Dropper Channel as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S. Top Channel as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S. Base Angle as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of M.S. Gaurding Angle as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Piercing Connector as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of J-Hook as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Fixing & Commisioning of Dead End Clamp as per RESPO manual and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Laying, Sagging and Binding & Jumpring of A.C.S.R. WEASEL Conductor as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding of AB Cable (3X120+1X50+1X16) sq mm as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding of AB Cable (3X95+1X50+1X16) sq mm as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Laying, Sagging and Binding of 3.5X150MM LT PVC Cable as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
Installation of 63 KVA T/F as per direction of Supervising Engineer. It including the cost of Labour T&P carrier etc required for proper completion of work.
VERMA ELECTRICAL AND CONSTRUCTION CO
MAA ELECTRICAL ENERGY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .