Providing air conditioners at various offices under DCSEM in Anushaktinagar, Mumbai
2021_DCSEM_641891_1
DCSEM/CQD/QSC/AN-AC/NIT /08/21-22 dated 04.08.2021
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
Anushaktinagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
12 Oct 2022
5 Aug 2021
27 Aug 2021
5 Aug 2021
25 Aug 2021
5 Aug 2021
5 Aug 2021 - 18 Aug 2021
Amount
GENERAL ABSTRACT
Total Amount
Description of Work / Item(s)
Amount
Air conditioners: Supply, installation, testing & commissioning of 1.8 TR Inverter hi-wall split type air conditioners of approved make with following specifiactions: 1. Cooling capacity - minimum 6.2kW , 2. Energy Efficient Rating- minimum 3.61 and suitable for 230V, 50 Hz, single phase A/C supply having auto humidity control, on/off timer with advance start up, auto climate technology, high capacity compressor, highest BEE star rating (i.e 5 star), including leak testing for entire system, vaccumising using vaccum pump, R410a/R32 gas charging as per installation manual, for smooth operation of AC`s etc complete all as per the instructions & to the entire satisfaction of EIC.
Refrigerant piping with insulation: Refrigerant copper piping with 10 mm rubber nitrile insulation as per site situation with necessary structural clamps/ supports/ bends/ elbows/ reducers/U-bends/ flare nuts/ adapters/any other brass fittings as required etc. wrapped with monsoon tape all as per AC`s manufacturer's standards.
Drain piping: PVC drain piping(flexible/hard) of suitable size upto 25 mm diameter duly insulated with heatlone sheet, etc. complete all as per the site condition & instructed by EIC.
Control cabling : Control cabling with adequate size of copper conductor wire/ power cable to connect outdoor units with respective indoor units & power cable to connect power outlet to ODU/IDU complete with lug connections etc. complete all as per site situation as required & instructed by the Engineer–in–Charge.
4 core x 2.5 sq.mm cable
3 core x 2.5 sq.mm cable
M.S. Stands: Fabrication, supply & installation of M.S stand for the ODU of split A/C unit as required & fabricated with suitable opening mechanism for maintenance purpose of ODU unit, painting with one coat of red oxide primer & two coats of enamel paints of approved make & shade to all M.S parts at all levels & elevations as required and desired by EIC.
Casing & caping: Supply & laying of casing/caping (PVC trunking 100 mm x 50 mm) for enclosing refrigerant tubing with insulation, drain line and electrical cable as per site condition, specifications and as instructed by E.I.C.
Dismantling and safe removal of Air conditioners: Dismantalling and safe removing the old existing wall mounted air conditioner including pumpdown of refrigerant in the system,safely removal its copper piping & M.S. stand and packing of existing piping holes etc. complete all as per requirement and instructed by EIC.
FREEZE AIR
FREEZE AIR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .