GEMC-511687700757868
Awarded to Himachal Pharmaceuticals
₹3.9 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Blood Pressure recording Units | Bio Plus BP Apparatus | - | 250 NOS | ₹1,568 | 392,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.9 LQualified Make: Bio Plus
Model: Bio Plus BP Apparatus SCO 159 SECTOR 23 POST OFFICE SECTOR 24D CHANDIGARH CHANDIGARH 160023 | CHANDIGARH | CHANDIGARH | 160023 | Make: Bio Plus
Model: Bio Plus BP Apparatus | L1 | Qualified | |
| 2 | L2₹4.4 L+₹50,500 (12.9%)Qualified Make: Bio Plus
Model: Bioplus POST OFFICE MUBARKPUR PATIALA PUNJAB 140201 | S A S NAGAR | PUNJAB | 140201 | Make: Bio Plus
Model: Bioplus | L2 | Qualified | |
| 3 | L3₹5.4 L+₹1.5 L (37.1%)Qualified Make: Bio Plus
Model: BIO+214 00 PC GROUP AKHARI BYPASS TRIMUHANI CHUNAR ROAD VARANASI VARANASI VARANASI UTTAR PRADESH 221011 | VARANASI | UTTAR PRADESH | 221011 | Make: Bio Plus
Model: BIO+214 | L3 | Qualified | |
| 4 | L4₹5.5 L+₹1.6 L (41.6%)Qualified Make: Diamond
Model: DIAMOND L.E.D MERCURY FREE Diamond BPDG 041) 1518 8 BHAGIRATH PALACE DELHI DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | Make: Diamond
Model: DIAMOND L.E.D MERCURY FREE Diamond BPDG 041) | L4 | Qualified | |
| 5 | L5₹5.6 L+₹1.7 L (42.2%)Qualified Make: Diamond
Model: DIAMOND L.E.D MERCURY FREE Diamond BPDG 041) 00 MUBARAKPUR CHAKIA CHAKIA CHANDAULI UTTAR PRADESH 232103 | CHANDAULI | UTTAR PRADESH | 232103 | Make: Diamond
Model: DIAMOND L.E.D MERCURY FREE Diamond BPDG 041) | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
12 Sept 2018, 11:00 amClosed
blood pressure recording units Blood Pressure Recording Units ( 250 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CONFIGURATION DETAILS Type Of SPHYGMOM ANOMETERS or Blood Pressure recording unit: Digital Mercurial
Aneroid
Digital Conformity to Indian Standrad for SPHYG MOMANOMETERS NA for digital IS:3390 latest for Mercurial
IS 7652 latest for Aneroid
NA for digital Measuring device Mechnical Mechnical Type Portable Portable
Mountable/Fixed
Inclined
Integrated ISI MARKED Yes Yes
NA for digital CM/L No and validity date 0196043 * Measurement Method Auscultatory method * Display for Digital BP instrument: LCD(Liquid Crystal Digital) Display * Range: Pressure 0 to 300 * 1/4 measurement (mmHg) Range:Pulse measurement for digital with accuracy ± 5%. (per minute) 40 to 200 * Accuracy:Pressure measurement (mmHg) +/- 3 * Pressure Detection Capacitive Pressure sensor * Inflation Manual * Deflation and rapid Air Release Manual * Cuff Range Medium (22-32)cm Small (18-22)cm
Medium (22-32)cm
Large (32-45)cm Dimensions of the Equipment (mmXmm) MM*MM * Dimensions of the Display screen (mmXmm) MM*MM * Operating Temperature range 0 to 55 degree Celsius * Stroage Temperature range (-10) to 55 degree Celsius * Automatic power off if system is idle for 3 minutes. Yes * Weight (in gram) 1500 * Power Power Source: AA size chargeable battery set AA size chargeable battery set
Either Charageble Battery Set Or {220 Volt
50 Hz AC Supply ] Type of AA Size chargeable Battery (AA Size) Alkaline Alkaline
Lithium
Ni- cd WARRANTY
CERTIFICATIONS
TEST REPORTS Warranty Period (in Year) 1 1
2
3 (or higher) Availability of Type Test Report covering complete test parameters as per IS3390 latest for Mercurial and IS7652 latest for Aneriod type
from any ILAC/NABL accredited/Central Gov LABFor digital type Yes * 2/4 including Environmental test from any ILAC/NABL accredited/Central Gov LAB Type test report No and date BP-(233)01 26/07/17 * Name and address of the Lab where test Conducted. BUREAU OF INDIAN STANDARDS
MARKET YARD
PUNE - 411037 * CE Marking Certificate for B.P. Apparatus Model. Yes * Conformity to OILM- R-16-1 and OILM- R-16-2 for both Non- invasive mechanical sphygmomanometers and Non-invasive automated sphygmomanometers are for guidance and All the Gazette of india related to legal metrology issued time to time
are applicable to the specification as well as to the product. Yes * Others Certificate ie ROHS
WHO
GMP etc. ISI * For Digital Sphygmomanometer
Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a) Dry heat test (For 16 hrs at a temp of 55degree C in accordance with IS: 90 00/part-3/section-3/197 7)latest Yes * For Digital Sphygmomanometer Cold test(For 4 hrs at a temp of (-10) degree C in accordance with IS: 9 000/part-2/section-3/19 77latest c) Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a Yes * 3/4 temp 55 degree C & 95% RH in accordance with IS: 9000/part-5/sec tion-1/1981)latest Note:- The BP Instrument shall be checked for all the parameters before conditioning After completion of the above environmental tests sequence
with a recovery period of 1 to 2 hrs
BP Instrument shall be functional " * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kul Bhushan 160031
Government Medical College & Hospital Sector 32
Chandigarh
160031 250 50
580903
GEM/2018/B/82394
GeM Contract
blood pressure recording units
GeM Contract
50 days
Chandigarh; Chandigarh
PRODUCT
Awarded to Himachal Pharmaceuticals
₹3.9 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Blood Pressure recording Units | Bio Plus BP Apparatus | - | 250 NOS | ₹1,568 | 392,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| blood pressure recording units Blood Pressure Recording Units ( 250 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CONFIGURATION DETAILS Type Of SPHYGMOM ANOMETERS or Blood Pressure recording unit: Digital Mercurial | - | - | - |
| Aneroid | - | - | - |
| Digital Conformity to Indian Standrad for SPHYG MOMANOMETERS NA for digital IS:3390 latest for Mercurial | - | - | - |
| IS 7652 latest for Aneroid | - | - | - |
| NA for digital Measuring device Mechnical Mechnical Type Portable Portable | - | - | - |
| Mountable/Fixed | - | - | - |
| Inclined | - | - | - |
| Integrated ISI MARKED Yes Yes | - | - | - |
| NA for digital CM/L No and validity date 0196043 * Measurement Method Auscultatory method * Display for Digital BP instrument: LCD(Liquid Crystal Digital) Display * Range: Pressure 0 to 300 * 1/4 measurement (mmHg) Range:Pulse measurement for digital with accuracy ± 5%. (per minute) 40 to 200 * Accuracy:Pressure measurement (mmHg) +/- 3 * Pressure Detection Capacitive Pressure sensor * Inflation Manual * Deflation and rapid Air Release Manual * Cuff Range Medium (22-32)cm Small (18-22)cm | - | - | - |
| Medium (22-32)cm | - | - | - |
| Large (32-45)cm Dimensions of the Equipment (mmXmm) MM*MM * Dimensions of the Display screen (mmXmm) MM*MM * Operating Temperature range 0 to 55 degree Celsius * Stroage Temperature range (-10) to 55 degree Celsius * Automatic power off if system is idle for 3 minutes. Yes * Weight (in gram) 1500 * Power Power Source: AA size chargeable battery set AA size chargeable battery set | - | - | - |
| Either Charageble Battery Set Or {220 Volt | - | - | - |
| 50 Hz AC Supply ] Type of AA Size chargeable Battery (AA Size) Alkaline Alkaline | - | - | - |
| Lithium | - | - | - |
| Ni- cd WARRANTY | - | - | - |
| CERTIFICATIONS | - | - | - |
| TEST REPORTS Warranty Period (in Year) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 (or higher) Availability of Type Test Report covering complete test parameters as per IS3390 latest for Mercurial and IS7652 latest for Aneriod type | - | - | - |
| from any ILAC/NABL accredited/Central Gov LABFor digital type Yes * 2/4 including Environmental test from any ILAC/NABL accredited/Central Gov LAB Type test report No and date BP-(233)01 26/07/17 * Name and address of the Lab where test Conducted. BUREAU OF INDIAN STANDARDS | - | - | - |
| MARKET YARD | - | - | - |
| PUNE - 411037 * CE Marking Certificate for B.P. Apparatus Model. Yes * Conformity to OILM- R-16-1 and OILM- R-16-2 for both Non- invasive mechanical sphygmomanometers and Non-invasive automated sphygmomanometers are for guidance and All the Gazette of india related to legal metrology issued time to time | - | - | - |
| are applicable to the specification as well as to the product. Yes * Others Certificate ie ROHS | - | - | - |
| WHO | - | - | - |
| GMP etc. ISI * For Digital Sphygmomanometer | - | - | - |
| Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a) Dry heat test (For 16 hrs at a temp of 55degree C in accordance with IS: 90 00/part-3/section-3/197 7)latest Yes * For Digital Sphygmomanometer Cold test(For 4 hrs at a temp of (-10) degree C in accordance with IS: 9 000/part-2/section-3/19 77latest c) Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a Yes * 3/4 temp 55 degree C & 95% RH in accordance with IS: 9000/part-5/sec tion-1/1981)latest Note:- The BP Instrument shall be checked for all the parameters before conditioning After completion of the above environmental tests sequence | - | - | - |
| with a recovery period of 1 to 2 hrs | - | - | - |
| BP Instrument shall be functional " * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Kul Bhushan 160031 | - | - | - |
| Government Medical College & Hospital Sector 32 | - | - | - |
| Chandigarh | - | - | - |
| 160031 250 50 | - | - | - |
Exempted
29 Sept 2018
7 Sept 2018
contract_GEMC-511687700757868.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_580903.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .