Loading…
Loading…
Tender ID
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
6 May 2026, 3:00 pmClosed
AT TSK Div:- Augmentation of Capacity of Running Room/Rest Room at LEDO, NTSK, DBRG & NLP.
01-TSK-ENGG-10-2026~NFR
01-TSK-ENGG-10-2026
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹4.5 L
6 May 2026
13 Apr 2026
22 Apr 2026
A-CPWD Items in connection with the work:- Augmentation of Capacity
Room/Rest Room at LEDO, DBRG, NTSK & NLP.
Item- 1 CPWD ITEMS
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
2.1S General
Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding
1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, for
all lift, including getting out the excavated soil
and disposal of surplus excavated soil as
directed, within a lead of 50 m.
2.25 Filling available excavated earth (excluding cum 660 196 129360
rock) in trenches, plinth, sides of foundations
2 etc. in layers not exceeding 20 cm in depth,
consolidating each deposited layer by ramming
and watering, lead up to 50 and for all lift.
TINSUKIA DIVISION-ENGINEERING/N F RLY
2.27 Supplying and filling in plinth with sand under cum 118 2123.75 250602.5
3 floors, including watering, ramming,
consolidating and dressing complete.
Surface dressing of the ground including
removing vegetation and in-equalities not
exceeding 15 cm deep and disposal of rubbish,
lead up to 50 m and lift up to 1.5 m.
2.31 Clearing jungle including uprooting of rank Sqm 405 17.6 7128
vegetation, grass, brush wood, trees and
saplings of girth up to 30 cm measured at a
height of 1 m above ground level and removal
of rubbish up to a distance of 50 m outside the
periphery of the area cleared.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
derived from natural sources : 4 graded stone
aggregate 20 mm nominal size derived from
natural sources)
derived from natural sources : 6 graded stone
aggregate 40 mm nominal size derived from
natural sources)
5.0 REINFORCEMENT CEMENT CONCRETE
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. Sqm 151 392.15 59214.65
for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies Sqm 628 927.25 582313
and access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 619 736.4 455831.6
bressummers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 781 961.3 750775.3
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Fe- Kg 8400 107.85 905940
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
5.22A.6 Thermo-Mechanically Treated bars of grade Fe- Kg 19900 107.85 2146215
5.33S DESIGN MIX CONCRETE
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and laying in position ready mixed or
site batched design mix cement concrete for
reinforced cement concrete work; using coarse
aggregate and fine aggregate derived from
natural sources, Portland Pozzolana / Ordinary
Portland /Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to
5.33 accelerate / retard setting of concrete, to
improve durability and workability without
impairing strength; including pumping of
concrete to site of laying, curing, carriage for all
leads; but excluding the cost of centering,
shuttering, finishing and reinforcement as per
direction of the engineer-in-charge, for the
following grades of concrete.:
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement cum 65.4 9504.75 621610.65
content of 330 kg /cum
5.33.2 All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cement cum 129.2 9860.4 1273963.68
content of 330 kg /cum
5.35 Add for using extra cement in the items of Quintal 60 733.5 44010
16 design mix over and above the specified
cement content therein.
6.0 MASONRY WORK
6.1S General
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
6.12S HALF BRICK MASONRY
Half brick masonry with common burnt clay
F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to
8.0 CLADDING WORK
8.1S General
Providing and fixing 18 mm thick gang saw cut,
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanity
counters, window sills, facias and similar
locations of required size, approved shade,
colour and texture laid over 20 mm thick base
cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including
rubbing, curing, moulding and polishing to
edges to give high gloss finish etc. complete at
Granite stone slab colour black, Cherry/Ruby
Providing edge moulding to 18 mm thick marble
stone counters, Vanities etc., including machine
8.3 polishing to edge to give high gloss finish etc.
complete as per design approved by Engineer-
8.4 Extra for fixing marble /granite stone, over and Metre 192 568.55 109161.6
above corresponding basic item, in facia and
21 drops of width upto 150 mm with epoxy resin
based adhesive, including cleaning etc.
8.20S STONE WORK DRY CLADDING
TINSUKIA DIVISION-ENGINEERING/N F RLY
8.31 Providing and fixing Ist quality ceramic glazed Sqm 180 1267.95 228231
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
22 Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board
9.20 construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers
on both faces of shutters.
9.20.2 30 mm thick including ISI marked Stainless Sqm 11.9 3167.95 37698.61
Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board
9.21 construction with frame of 1st class hard wood
and well matched commercial 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters:
9.21.2 30 mm thick including ISI marked Stainless Sqm 44.2 2172.1 96006.82
Steel butt hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including
priming coat with approved steel primer all
9.53 Providing 40x5 mm flat iron hold fast 400 mm Each 156 228.85 35700.6
long including fixing to frame with 10 mm
diameter bolts, nuts and wooden plugs and
26 embedding in cement concrete block
300x100x150 mm 1:3:6 mix (1 cement : 3
coarse sand : 6 graded stone aggregate 20 mm
9.72S BRASS FITTINGS
Providing and fixing bright finished brass tower
9.74 bolts (barrel type) with necessary screws etc.
9.76 Providing and fixing bright finished brass 100 Each 20 854.65 17093
mm mortice latch and lock with 6 levers and a
pair of lever handles of approved quality with
necessary screws etc. complete.
Providing and fixing special quality bright
finished brass cupboard or ward robe locks with
four levers of approved quality including
necessary screws etc. complete.
9.83 Providing and fixing aluminium die cast body Each 22 1124.85 24746.7
tubular type universal hydraulic door closer
(having brand logo with ISI, IS : 3564,
embossed on the body, door weight upto 35 kg
and door width upto 700 mm), with necessary
accessories and screws etc. complete.
9.105S GYPSUM BOARD PARTITIONS
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made uPVC door
frame made of uPVC extruded sections having
an overall dimension as below (tolerance +/-
1mm), with wall thickness 2.0 mm ( +/- 0.2
mm), corners of the door frame to be Jointed
with galvanized brackets and stainless steel
9.117 screws, joints mitred and Plastic welded. The
hinge side vertical of the frames reinforced by
galvanized M.S. tube of size19 X 19 mm and
1mm ( +/- 0.1 mm) wall thickness and 3 nos.
stainless steel hinges fixed to the frame
complete as per manufacturer's specification
and direction of Engineer- in-charge
31 9.117.2 Extruded section profile size 42x50 mm Metre 24 331.35 7952.4
9.118 Providing and fixing to existing door frames.
9.118.2 30 mm thick factory made Polyvinyl Chloride Sqm 12 3253.8 39045.6
(PVC) door shutter made of styles and rails of a
uPVC hollow section of size 60x30 mm and wall
thickness 2 mm ( +/- 0.2 mm), with inbuilt
decorative moulding edging on one side. The
styles and rails mitred and joint at the corners
by means of M.S. galvanised/ plastic brackets of
size 75x220 mm having wall thickness 1.0 mm
and stainless steel screws. The styles of the
shutter reinforced by inserting galvanised M.S.
tube of size 25x20 mm and 1 mm ( +/- 0.1 mm)
wall thickness. The lock rail made up of 'H'
32 section, a uPVC hollow section of size 100x30
mm and 2 mm ( +/- 0.2 mm) wall thickness
fixed to the shutter styles by means of plastic/
galvanised M.S. 'U' cleats. The shutter frame
filled with a uPVC multi-chambered single panel
of size not less than 620 mm, having over all
thickness of 20 mm and 1 mm ( +/- 0.1 mm)
wall thickness . The panels filled vertically and
tie bar at two places by inserting horizontally 6
mm galvanised M.S. rod and fastened with nuts
and washers, complete as per manufacturer's
specification and direction of Engineer-in-
Providing and fixing cup board shutters with 25
mm thick veneered particle board IS : 3097
marked, exterior grade (Grade I), of approved
make, including IInd class teak wood lipping of
25 mm wide x 12 mm thick with necessary
screws and bright finished stainless steel piano
hinges, complete as per direction of Engineer-
9.130.1 With decorative veneering on one side and Sqm 40 1927.5 77100
commercial veneering on other side
10.0 STEEL WORK
10.1S General
10.2 Structural steel work riveted, bolted or welded Kg 910 133.7 121667
in built up sections, trusses and framed work,
34 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer all complete.
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made ISI marked
steel glazed doors, windows and ventilators,
side /top /centre hung, with beading and all
members such as F7D,F4B, K11 B and K12 B
etc. complete of standard rolled steel sections,
joints mitred and flash butt welded and sash
10.11 bars tenoned and riveted, including providing
and fixing of hinges, pivots, including priming
coat of approved steel primer, but excluding
the cost of other fittings, glass panes complete
all as per approved design, (sectional weight of
only steel members shall be measured for
embedded in cement concrete block 15x10x10
cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size)
Providing and fixing M.S. Tubular frames for
doors, windows, ventilators and cupboard with
rectangular/ L-Type sections, made of 1.60 mm
thick M.S. Sheet, joints mitred, welded and
grinded finish, with profiles of required size,
including fixing of necessary butt hinges and
screws and applying a priming coat of
approved steel primer.
embedded in cement concrete block 15x10x10
cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6
graded stone aggregate 20 mm nominal size)
10.28 Providing and fixing stainless steel ( Grade 304) Kg 322 772.4 248712.8
railing made of Hollow tubes, channels, plates
etc., including welding, grinding, buffing,
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete,
including fixing the railing with necessary
37 accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on
the top of the floor or the side of waist slab with
suitable arrangement as per approval of
Engineer-in-charge, (for payment purpose only
weight of stainless steel members shall be
considered excluding fixing accessories such as
nuts, bolts, fasteners etc.).
Providing & fixing fly proof wire gauze to
10.29 windows, clerestory windows & doors with M.S.
Flat 15x3 mm and nuts & bolts complete.
10.29.1 Galvanised M.S. Wire gauze with 0.63 mm dia Sqm 42 844.7 35477.4
wire and 1.4 mm aperture on both sides
11.0 FLOORING
11.1S General
Cement concrete flooring 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate)
11.3 finished with a floating coat of neat cement,
including cement slurry, but excluding the cost
of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 128 614.2 78617.6
11.16S TILE FLOORING
Chequered precast cement concrete tiles 22
mm thick in footpath & courtyard, jointed with
neat cement slurry mixed with pigment to
match the shade of tiles, including rubbing and
cleaning etc. complete, on 20 mm thick bed of
cement mortar 1:4 (1 cement: 4 coarse sand).
40 11.20.1 Light shade pigment using white cement Sqm 58 1402 81316
11.41S VITRIFIED FLOOR TILES
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and laying Vitrified tiles in floor in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade,
laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey
11.41A cement slurry @3.3 kg/sqm including grouting
t h e joints with white cement and matching
pigments etc. The tiles must be cut with the
zero chipping diamond cutter only . Laying of
tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles
gently and easily.
Double charge vitrified tile polished finish of
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
12.0 ROOFING
12.24S CEILING
Providing 10 mm thick plaster of Paris (gypsum
anhydrous) ceiling up to a height of 5 m above
floor level, over first class kail wood strips 25x6
mm with 10 mm gap in between and reinforced
with rabbit wire mesh fixed to wooden frame
(frame work to be paid separately):
12.37S RAIN WATER SPOUT AND PIPE
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
12.41 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised -
PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degree
12.50 Providing and fixing precoated galvanised iron Sqm 152 738.65 112274.8
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
of total coated thickness 0.50 mm (base metal
of minimum 0.45 mm thickness with total
coating thickness of 0.05 mm) with zinc coating
120 grams per sqm as per IS: 277, in 240 mpa
steel grade, 5-7 microns epoxy primer on both
side of the sheet and polyester top coat 15-18
microns. Sheet should have protective guard
film of 25 microns minimum to avoid scratches
during transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing precoated galvanised steel
sheet roofing accessories of total coated
thickness 0.50 mm (base metal of minimum
0.45 mm thickness with total coating thickness
12.51 of 0.05 mm) with Zinc coating 120 grams per
sqm as per IS: 277, in 240 mpa steel grade, 5-7
microns epoxy primer on both side of the sheet
and polyester top coat 15-18 microns using self
drilling/ self tapping screws complete :
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
13.1 12 mm cement plaster of mix :
15 mm cement plaster on the rough side of
single or half brick wall of mix :
CEMENT PLASTER WITH A FLOATING COAT OF
12 mm cement plaster finished with a floating
coat of neat cement of mix :
13.16S 6 mm CEMENT PLASTER
13.16 6 mm cement plaster of mix :
13.20S PEBBLE DASH PLASTER
13.26 Providing and applying plaster of paris putty of Sqm 1380 262.7 362526
2 mm thickness over plastered surface to
prepare the surface even and smooth
13.37S INTERIOR FINISHING
Distempering with 1st quality acrylic distemper
(ready mixed) having VOC content less than 50
13.41 gram/litre, of approved manufacturer and of
required shade and colour all complete to
achieve even shade and colour :
13.41.1 New work (two or more coats) over and Sqm 1440 185.65 267336
including water thinnable priming coat with
cement primer having VOC content less than 50
13.44S EXTERIOR FINISHING
Finishing walls with water proofing cement
paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 Sqm 1370 116.9 160153
Painting (two or more coats) on rain water, soil
waste and vent pipes and fittings with synthetic
enamel paint of approved brand and
manufacture and required colour over a
priming coat of approved steel primer on new
Painting with synthetic enamel paint of
13.61 approved brand and manufacture to give an
Lettering with black Japan paint of approved letter
brand and manufacture per cm
TINSUKIA DIVISION-ENGINEERING/N F RLY
Distempering with 1st quality acrylic distemper,
having VOC (Volatile Organic Compound )
content less than 50 grams/ litre, of approved
brand and manufacture, including applying
additional coats wherever required, to achieve
even shade and colour.
Finishing walls with water proofing cement
paint of required shade :
13.109.1 Old work (one or more coats applied @ 2.20 Sqm 660 112.9 74514
kg/10 sqm) over priming coat of primer applied
@ 0.80 litrs/10 sqm complete including cost of
Finishing walls with Acrylic Smooth exterior
paint of required shade :
13.111.1 Old work (Two or more coat applied @ 1.67 ltr/ Sqm 660 120.75 79695
10 sqm) on existing cement paint surface
14.0 REPAIRS TO BUILDING
14.1S General
Renewing glass panes, with putty and nails
14.5 wherever necessary including racking out the
14.5.1 Float glass panes of nominal thickness 4 mm Sqm 48 1090.65 52351.2
(weight not less than 10kg/sqm)
16.0 ROAD WORK
16.1S ROADS
Dry brick pitching half brick thick in drains
16.12 including supply of bricks and preparing the
surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) Sqm 400 644.05 257620
bricks of class designation 7.5
17.0 SANITARY INSTALLATIONS
17.1S General
Providing and fixing white vitreous china
pedestal type water closet (European type) with
seat and lid, 10 litre low level white vitreous
china flushing cistern & C.P. flush bend with
fittings & C.I. brackets, 40 mm flush bend,
overflow arrangement with specials of standard
make and mosquito proof coupling of approved
municipal design complete, including painting
of fittings and brackets, cutting and making
good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic Each 18 8006.6 144118.8
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.5 White Vitreous China Angle back wash basin Each 14 2226.35 31168.9
65 size 600 x 480 mm with single 15mm C.P. brass
Providing and fixing Stainless Steel A ISI 304
(18/8) kitchen sink as per IS:13983 with C.I.
brackets and stainless steel plug 40 mm,
including painting of fittings and brackets,
cutting and making good the walls wherever
17.10.1 Kitchen sink with drain board
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing mirror of superior glass (of
approved quality) and of required shape and
17.32 size with plastic moulded frame of approved
make and shade with 6 mm thick hard board
17.71 Providing and fixing PTMT liquid soap container Each 21 168.35 3535.35
109 mm wide, 125 mm high and 112 mm
distance from wall of standard shape with
bracket of the same materials with snap fittings
of approved quality and colour, weighing not
less than 105 gms.
Providing and fixing PTMT towel rail complete
with brackets fixed to wooden cleats with CP
brass screws with concealed fittings
arrangement of approved quality and colour.
17.73.2 600 mm long towel rail with total length of 645 Each 14 708.95 9925.3
69 mm, width 78 mm and effective height of 88
mm, weighing not less than 190 gms.
18.0 WATER SUPPLY
18.7S C.P.V.C. PIPES
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, and all CPVC plain
& brass threaded fittings, including fixing the
18.7 pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one
step CPVC solvent cement and testing of joints
complete as per direction of Engineer in
Charge. ( Internal work - Exposed on wall )
18.15S BRASS FITTINGS
Providing and fixing brass bib cock of approved
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
Providing and fixing gun metal non- return
valve of approved quality (screwed end) :
18.19.3 40 mm nominal bore
Providing and fixing C.P. brass shower rose with
15 or 20 mm inlet
C.I. SLUICE VALVES/ FIRE HYDRANTS &
18.48 Providing and placing on terrace (at all floor Per 8000 11 88000
levels) polyethylene water storage tank, IS : Litre
12701 marked, with cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow pipes but without
fittings and the base support for tank.
21.0 ALUMINIUM WORK
21.1S General
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with
extruded built up standard tubular sections/
appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia
and size, including necessary filling up the gaps
at junctions, i.e. at top, bottom and sides with
21.1 required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically
wherever required including cleat angle,
Aluminium snap beading for glazing / panelling,
C.P. brass / stainless steel screws, all complete
as per architectural drawings and the directions
of Engineer-in-charge. (Glazing, panelling and
dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent or Kg 550 495.05 272277.5
79 dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots
and making provision for fixing of fittings
wherever required including the cost of EPDM
rubber / neoprene gasket required (Fittings
shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent or Kg 484 598.6 289722.4
80 dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15)
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc.
with EPDM rubber / neoprene gasket etc.
21.3 complete as per the architectural drawings and
the directions of engineer-in-charge . (Cost of
aluminium snap beading shall be paid in basic
21.3.1 With float glass panes of 4.0 mm thickness Sqm 102 1176.8 120033.6
(weight not less than 10kg/sqm)
21.18 Providing and fixing 12 mm thick frameless Sqm 49 5325.9 260969.1
toughened glass door shutter of approved
brand and manufacture, including providing
and fixing top & bottom pivot & double acting
82 hydraulic floor spring type fixing arrangement
and making necessary holes etc. for fixing
required door fittings, all complete as per
direction of Engineer-in-charge (Door handle,
lock and stopper etc. to paid separately)
26.0 NEW TECHNOLOGIES AND MATERIALS
26.73S PREFAB/PRECAST TECHNOLOGY
TINSUKIA DIVISION-ENGINEERING/N F RLY
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite) solid
door/window/Ceosetory windows & other
Frames/Chowkhat comprising of virgin PVC
polymer of K value 58-60 (Suspension Grade),
calcium carbonate and natural fibers (wood
powder/ rice husk/ wheat husk) and non toxic
additives (maximum toxicity index of 12 for 100
gms) fabricated with miter joints after applying
PVC solvent cement and screwed with full body
threaded star headed SS screws having
26.86 minimum frame density of 750 kg/cum, screw
withdrawal strength of 2200 N (Face) & 1100 N
(Edge), minimum compressive strength of 58
N/mm2, modulus of elasticity 900 N/mm2 and
resistance to spread of flame of Class A
category with property of being termite/borer
proof, water/moisture proof and fire retardant
and fixed in position with M.S hold fast/lugs/SS
dash fasteners of required dia and length
complete as per direction of Engineer-In-
Charge. (M.S hold fast/lugs or SS dash fasteners
shall be paid for separately).
Providing and fixing factory made single
extruded WPC (Wood Polymer Composite) solid
plain flush door shutter of required size
comprising of virgin polymer of K value 58-60
(Suspension Grade), calcium carbonate and
natural fibers (wood powder/ rice husk/wheat
husk) and non toxic additives (maximum
toxicity index of 12 for 100 gms) having
minimum density of 650 kg/cum and screw
26.87 withdrawal strength of 1800 N (Face) & 900 N
(Edge), minimum compressive strength 50
N/mm2, modulus of elasticity 850 N/mm2 and
resistance to spread of flame of Class A
category with property of being termite/borer
proof, water/moisture proof and fire retardant
and fixing with stainless steel butt hinges of
required size with necessary full body threaded
star headed counter sunk S.S screws, all as per
direction of Engineer-In- Charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .