Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 184 SEC 3 IMT MANESAR GURGAON HARYANA 122050 | GURGAON | HARYANA | 122050 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
8 Mar 2021, 3:00 pmClosed
CWE (AF) NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007
CONSTRUCTION OF CERTAIN CHEMICAL EARTHING PITS AND CONVENTIONAL EARTHING PITS FOR VARIOUS BUILDINGS AT AF STATION OJHAR
2021_MES_416616_1
80363
Open Tender
Civil Works
Item Rate
180 days
GE (AF) OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) OJHAR
₹94,000
24 Mar 2021
27 Jan 2021
13 Mar 2021
27 Jan 2021
8 Mar 2021
22 Feb 2021
27 Jan 2021 - 3 Feb 2021
Amount
Soil resistivity testing all as per standard Engr practice and as directed.
Taking up / down old unserviceble earthings of any type all as directed.
(e) Back-fill compound resistivity should not be more than 0.12 Ohm meter and minimum 2 bags of approximate 25 Kg each bag should be filled in each earthing bore, however if required extra chemical bach-fill materials should be filled to achive result below 03 ohm without any extra cost. (f) The description/size/quantity of items mentioned in above are for indicative only how ever the quantity/size may vary at site condition to maintain the earth resistance less than 03 ohm and as such quoted rates should be considering the all factors. (g) Testing on completion & achiving resistance less than 03 ohm & submitting report to Engineer-in Charge duly signed by users after seccessfull completion of earthing. (h) If resistance value is found more than 03 ohm, any time after execution upto end of defect liability period contractor has to do needful action within 07 days without any extra cost to bring the value less than 03 Ohm, failing which the cost of the earthing (as quoted by the contractor or prevaling in the market whichever is high will be recovered from the contractor. (j) Earth strip copper of size 20x3mm beyond the earthing point will be measured and paid seprately under respective item of schedule. Make :- JEF TECHNO SOLUTIONS Pvt Ltd /U-PROTEC/Pragati Electrocom Pvt Ltd/equivalent as per his description approved by GE
Material & labour for earthing complete supply, install , testing and commissioning maintenance free Tripod earthings comprising of high tensile low carbon steel rod of 3 mtrs length & 17.2mm dia with 250 micron (average) molecularly bonded copper on the outer surface to confirm with the requirement of UL 467 placed in bore min 150mm dia upto 3 mtr deep with and including necessaary excavation by any means for tripod earthing in any type of soil/ strata like soil, rock or any other encluding back-fill compound strictly be a carbon based conductive type which has resistively of less than 0.12 ohm mtr as per clause 14.5 D of IEEE:80 Standard, 03 Nos earth electrode to be fixed at a distance of 3 Mtr to each other (in Triangle) and inter connected with and including copper strip of size 20x3mm and back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for condition. Compound shall be suplied in sealed bags. The earth electrode should finally be housed in heavy duty concreate/PVC chamber with cover of size 300x300x300mm for future access. Back-fill compound should be enviroment freindly, should solodoty when mixed with water and should not leach/diffuse into ground.
M&L for earthing in repair including taking out GI plate with pipe and complete with galvanised steel earth plate electrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level,connected to galvanised iron strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron mild steel frame embedded in the concrete enclouser fineshed flushed & CI cover 10 mm thick of size (300mmx300mm CI) having locking arrengment hinged to CI frame all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil , rock /strata/ other if any, complete testing on completion all as directed.
Note:- i) Filling the pit with black cotton soil brought at site.from out of defence land. ii) The excavated soil will be removed iii) Earth resistance should be less than 4 ohm. iv)GI strip up to 7.5 RM with GI pipe 40mm dia is included in the quoted rate. (v) If resistance value is found more than 04 ohm, any time after execution upto end of defect liability period contractor has to do needful action within 07 days without any extra cost to bring the value less than 04 Ohm, failing which the cost of the earthing (as quoted by the contractor or prevaling in the market whichever is high will be recovered from the contractor.
M&L for test point terminal block insulated from wall or external surface made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screws complete fixed on ebonite sheet 6mm thick fitted on MS flat 50x5mm bent to shape etc complete all as specified and as directed.
Supply only porcelain insulator white creamic GI/Aluminium strip supporter adequate to accomadate strip of 32 mm with fasteners complete all as specified and directed.
Supply and laying 15 mm bore GI tubing, fixing to wall, ceiling, laid in floors, concealled in walls, roof beam etc and jointing Galvanised steel water tubings, medium grade in std/any lengths with screwed and socket joints, together will all galvanised steel fitting such as socket, elbows, bends, tees reducers, union caps plugs, nipples short pieces etc fixed complete to walls by means of clips, wall hooks etc, or laid on surface/ floors or concealed in walls/ floors, complete all as specified and as directed. Make : Tata/ Jindal/ Prakash Surya/ Apollo.
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 meter in depth and getting out in soft/loose soil all as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm all as directed.
Removing of surplus soil not exceeding 50 meter and depositing where directed at a level not exc 1.50 mtr above the starting point all as directed.
Cutting existing steel tubing for alteration or additions and screwing existing steel tubing for and including insertion of tee 15mmx15mmx15mm alterations or addition
Supply and fixing 15mm bore Bib taps, cast iron alloy with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed.
Supply & Fix earth continuty conductor or main earthing lead ( Roof conductor or down conductor) above ground level fixed to wall/ roof duly insulated on batten or fixed on new porcelain insulators with clamping device or recessed or chases or burried in ground/ floor or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as requid 20x3 mm dia Copper strip Note :- i) The distance between porcelain insulator will not be more than 40 cm. ii) The quoted rates shall be deemed to be included with cost of T&P and labour required to work on roof top at lateral faces of existing hangers upto height of 25 Mtrs.
Ditto but 32 x 6 mm GI strip.
Material and labour for 40 mm bore GI tubing light grade with all fitting laid in trenches or fixed to wall or ceiling with clamps or fixed to floor complete all as specied and directed. Make : Tata/Jindal/Prakash Surya/Apollo.
Note:- The amount of schedule of credit on page No. 26 shall be deducted from the amount quoted against sch 'A' while deriving at the contract sum for accptance.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .