Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹35.4 L+₹3.4 L (10.8%)Rejected-Finance N A | NA | NA | 121004 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹35.9 L+₹3.9 L (12.4%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹37.7 L+₹5.7 L (18.0%)Rejected-Finance H NO 82 C BLOCK NO CC SHALIMAR BAGH DELHI 110088 | DELHI | NORTH DELHI | DELHI | 110088 | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹40.5 L+₹8.5 L (26.8%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
5 Jul 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
CONSTRUCTION OF TOILET BLOCK FOR INTEGRATED SPORT COMPLEX UNDER AGE B/R-II (S) AND AGE E/M (S) OF GE (SOUTH) DELHI CANTT-10
2021_MES_449294_1
GE/DS-29/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹83,000
Yes
6 Aug 2021
7 Jun 2021
7 Jul 2021
7 Jun 2021
5 Jul 2021
21 Jun 2021
8 Jun 2021 - 19 Jun 2021
Amount
B/R Items Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc for manholes,septic tanks, wells and laying of cable etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in any type soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated any type of soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 design mix with (20 mm graded aggregates) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 design mix with (20 mm graded aggregates) in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 design mix with (20 mm graded aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-25 design mix with (20 mm graded aggregates) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-charge.
All same as per item No. 09 above but here-in-before 6 to 8 mm dia in stirrups complete all as specified and directed by Engineer-in-charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns, and stanchions square or rectangular in shape complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class 'B' bricks strainght or curved on plan not exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' bricks strainght or curved on plan to any radius in half brick thick wall built in cement mortor 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Damp proof course 40mm thick to horizontal or vertical surfaces in Cement Concrete 1:2:4 type B-0 with WPC as per manufacturer instruction including neccessary formwork complete all as specified and directed by Engineer-in-Charge. Note-: WPC shall be measured and paid for seperately
Supply only Integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L 5mm thick Cement Plaster in cement mortar 1: 3 on concrete surfaces of ceiling,chajja,etc finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparaing newly plastered surfaces on Ceiling and applying two coats of distemper oil emulsion complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick Cement plaster in CM (1:4) on fair faces of brick or concrete surface and finished the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick Cement plaster in CM (1:6) on unfair faces of brick or concrete surface and finished the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete 1:4:8 Type D-2 (using 40 mm graded stone aggregate) in sub base of floors 100mm thick complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick cement concrete 1:2:4 Type B-1 (12.5 mm graded aggregate) as in floor surface finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick cement plaster in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite(of any type) work (table rubbed and polished) in floors, steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 20mm thick cement screed bed in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L Coloured Glazed ceramic tiles size 450 x 350 x7 mm thick on vertical surfaces such as skirtings, dados and riser to steps etc over 10mm thick rendring in CM 1:4 complete all as specified and directed by Engineer-in-Charge. (Note : Colour and scheme of tiles as approved by GE)
M&L Cement concrete type C1 1:3:6 (20mm graded stone aggregate) 75mm thick as in plinth protection etc complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated anodised aluminium as in frame & shutter of door, window, ventilators and shutter etc. with one or more rebates including jioning cleat for fixing etc. fixed type/louvered/sliding window or ventilators without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed by Engineer-in-Charge.
S&F 4.8 mm thick ordinary quality glass, frosted on one side, in square exc 0.5 Sqm each pane, fixed with aluminium beading in aluminium door/window/ventilator etc complete all as specified and directed by Engineer-in-Charge.
M&L for 12 mm thick Prelaminated particle board,exterior grade, prelaminated both side with decorative choice lamination , fixed in aluminium door of required size complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium barrel tower bolts ISI Marked of extruded section , 150 mm long complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium butt hinges ISI Marked 75mm size medium duty weight complete all as specified and directed by Engineer-in-Charge.
M&L for Aluminium alloy, anodised, 300 mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm Aluminium handles ISI Marked cast type, anodised complete all as specified and directed by Engineer-in-Charge.
M&L 20 mm bore Mild steel galvanized steel tubing medium grade with all fittings (such as bend, elbow, tees, short pieces, connectors, caps, plugs and unions etc) and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm gun metal gate Valves with iron wheel head, Screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm bore Mild steel galvanized steel tubing medium grade with all fittings (such as bend, elbow, tees, short pieces, connectors, caps, plugs and unions etc) and fixed complete all as specified and directed by Engineer-in-Charge.
S&F angle valves, cost copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle, 15 mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
S&F single lever wash hand basin mixer 15mm dia CP brass fancy type including joints to steel pipe or unions complete all as specified and directed by Engineer-in-Charge. (MAKE : CERA Cat No. F2003451 or its equivalent as specified Make)
M&L for 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms counter top for wash basin and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge. .
S&F counter top vitreous china wash hand basin of size 550x400x140mm , ivory, including waste fitting complete all as specified and directed by Engineer-in-Charge. (MAKE : CERA Cat No. S2020137 or EQUIVALENT in JAQUAR/HINDWARE)
S&F Vitreous china wash down water closet pan (pedestal pattern) , white including soft closed seat cover of closed pattern and twin flush cistern with in-built 100 mm S-trap complete all as specified and directed by Engineer-in-Charge. (MAKE : CERA Cat No. S1013114 or its equivalent as specified Make)
S&F vituous china bowl urinal flat back size 362x330x740 mm ivory with sensor based electronic flushing cistern complete all as specified and directed by Engineer-in-Charge. (MAKE : CERA Cat No. S4020107 or its equivalent as specified Make)
S&F curved shaped Urinal partition size- 900mm height x 450mm width with 8mm thick frosted glass and chrome finish complete all as specified and directed by Engineer-in-Charge. (MAKE : JAQUAR PRODUCT CODE : JSE-CHR-810UC450X or its equivalent as specified Make)
S&F for CP Brass Health Faucet with 1.0 mtr stainless steel flexible pipe of good quality & Hook complete all as specified and directed by Engineer-in-Charge. (MAKE : CERA Cat No. F8030301 or its equivalent as specified Make)
S&F CP Brass Toilet paper holder of good quality, fixed to walls with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F Rotational moulded three layer polyethylene water storage tanks Capacity 1000 ltr(cylin-drical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm bore float valve with epoxy coated aluminium rod and high density plastic ball including GI fitting complete all as specified and directed by Engineer-in-Charge.
M&L 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed by Engineer-in-Charge.
M&L 100mm dia Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
M&L 100mm Bends/Tapers/Branch piece or any other section (any radius),diminishing pieces complete all as specified and directed by Engineer-in-Charge.
M&L 75mm Cast iron soil, waste and vent pipes, (Sand Cast) in any length with or without ears with cement joints, fixed on wall complete all as specified and directed by Engineer-in-Charge.
M&L 75mm Bends/Tapers/Branch piece or any other section (any radius),diminishing pieces complete all as specified and directed by Engineer-in-Charge.
S&F CP connection pipe 15mm size with nuts of lenth 600mm long complete all as specified and directed by Engineer-in-Charge.
S&F Greenlam sturdo classique grandeur toilet cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact anti bacterial resistant 18mm thick solid compact laminate panels. Finish of the compact laminate should be suede/ raw silk, which includes doors, pilasters & intermediate panels finished with approved texture/ shade as per the detail frawings & as per IS 2046 (indian standard) and as per fire retardent BS-476/97 standard. The product should have green guard certificate. This also includes S&F in position necessary hardware made out of stainless steel (Grade 304/316) as per manufacturer's specifications & architect instructions like (a) Door Knob, (b) Gravity hinges, (c) Thumb turn lockset indicators, (d) Coat hooks, (e) U-Channels, (f) SS-Shoe box plate, (g) MS-Base plate, (h) Rubber noise deafening tape, (j) Screws & wall plugs. Note : All screws will be of 304 grade in SS with satin finish. All pilasters are supported by MS-base steel bottom cladding with SS shoe box plate. The base of the SS shoe box will be anchored to the floor with a clearance height upto 110mm. Fixing of internediates panels to the wall shall be SS 'L'-Bracket or Stainless U-channel section are fixed into wall with screw inserts. (MAKE : GREENLAM INDUSTRIES LIMITED and NIVEETA CORPORATION its equivalents as specified makes as directed by GE.
Toilet Cubicle with standard dimension of 1840mm height x 1000mm width x 1500mm depth, which includes 600mm door size width) complete all as specified and directed by Engineer-in-Charge. (Note : Overall Ht - 1840mm, ground clearance - 110mm, Divider Ht - 1730mm)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc for manholes,septic tanks,wells etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Material & Labour brick work with sub-class 'B' bricks (Old size bricks), straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick in cement mortar 1:4 on brick or concrete surfaces mixed with water proofing compund as per manufactures's instructions surfaces finished even and smooth without using extra cement complete including filling the joints flush in CM 1:4 complete all as specified and directed by Engineer-in-Charge. Note:- WPC will be measured & paid seperately.
M&L for Providing, precast cement concrete 1:2:4 type B-1in landings, cover slabs (for manholes/ Septic tanks etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping / benching including necessary from work and including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and directed by Engineer-in-Charge.
M&L for Plain Cement Concrete (1:4:8) type D-2, in concrete bed to drain pipes of 150 mm bore laid to falls, including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced concrete pipe class NP3 150mm bore laid in trenches on concrete bed, to required slope, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus material to a distance exc 250m but not exc 500m and deposited complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out soft loose soil complete all as specified and directed by Engineer-in-Charge.
Rolling and consolidating formation surface in cutting power roller 2 to 5 tonne complete all as specified and directed by Engineer-in-Charge.
M&L 75 mm thick Cement concrete type C- 2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade laid over 50mm laid sand cusion and joints grouted in Cement Mortar 1:4 finished smooth complete all as specified and directed by Engineer-in-Charge.
M&L for Providing, cement concrete Type B 1, 1:2:4 (20mm graded stone aggregate) as in roof kerbs of mud stops, rounded or chamfered on edge complete all as specified and directed by Engineer-in-Charge.
E/M Items M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through concealed PVC conduit and including Modular steel terminal boxes with white cover modular plate and frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable earth continuity wire to common earth and connected to earth dolly for One light/Fan/Bell point controlled by one 5 Amp switch one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) complete all as specified and directed by Engineer-in-Charge. Note :- The rate is inclusive cutting/chasing and making good disturbed surface with CM 1:3 and same surface finishs with the adjoining surface of disturbed area with OBD/Colour wash/white wash complete.
All same as per item No 73 above but here-in-before 5 Amp socket outlet on same board with through concealed PVC conduit.
All same as per item No 73 above but here-in-before One socket outlet 5 Amps on independent board.
All same as per Item No 73 above but here-in-before for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing complete.
S&F switch modular type, 1 way 6 Amp, 1module complete all as specified and directed by Engineer-in-Charge.
S&F modular Socket, 6 Amp - 2/3 pin 2module complete all as specified and directed by Engineer-in-Charge.
S&F switch modular type 1way 16 Amp, 1module complete all as specified and directed by Engineer-in-Charge.
S&F socket modular 6/16 Amp - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
S&F Surface mounting round/square shaped LED downlighter with durable housing with Al heat shrink with diffuser to give glare free light 12 Watt LED 6000K/6500K lamp type from ceiling areas, complete all as specified and directed by Engineer-in-Charge. (Make: Halonix HLDLS-R12-CW or its equivalent as Bajaj/CG/Havells/C&S).
S&F Wall mounted LED Integrated Batten T5 20 Watt - 4Ft White, indoor decorative PVC extruded LED battern-Integrated type fittings any type, complete all as specified and directed by Engineer-in-Charge. (Make: Halonix HLB-07-20-CW-IP or its equivalent as Bajaj/CG/Havells/C&S)
S&F ceiling rose surface Bakelite 65x25mm two to three terminals complete all as specified and directed by Engineer-in-Charge.
S&F 10W LED bulk head in engineering plastic housing with clear prismatic diffuser, 10W WHITE including all accessories connecting up twin core flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge. Make: (Make: Halonix HLBH-02-10CW or its equivalent as Bajaj/CG/Havells/C&S).
S&F in replacement of building security light fitting 30W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for and including pole dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc complete all as specified and directed by Engr-in-Charge.
S&F metal body exhaust fan 300 mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with existing complete all as specified and directed by Engr-in-Charge.
S&F water heater storage type (Geyser) of capacity 25 ltrs, BEE 5 star, body of ABS plastic material, copper inner tank, auto cat adjustable temperature, safety valve, thermal cut out input voltage 230 volts, power consumption 2 kw including all fittings 4 sets of nut, bolts and washers of minimum dia 10 mm, grouting in wall and making all electric and water connection. complete with heating element, thermostat,3 core lead, Plug top, safty valve and making good to disturbed surface complete all as specified and directed by Engr-in-Charge.
S&F single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one no MCB SP 20 Amps complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 32 Amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection all as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SP 6 to 32 Amps 240 Volts, 10kA, `C' curve all as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
Supply and laying XLPE insulated armoured (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of cable 16 Sqmm 4 core complete all as specified and directed by Engineer-in-charge as follows :
M&L Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified and directed by Engineer-in-charge. Note:- Payment purpose punned thickness shall be measured 18 CM.
Supply and laying sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable complete all as specified and directed by Engineer-in-charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Vipul Construction
verma enterprises
M/S GOPAL JEE SINGH
M/S.Parmod Johar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .