Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.9 L+₹65,304 (1.71%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹42.7 L+₹4.5 L (11.7%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹45.1 L+₹6.9 L (18.0%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹47.7 L+₹9.4 L (24.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹46.7 L
EMD Value
₹93,400
Closing Date
25 Mar 2023, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
PROVN OF BOREWELL NO-2 AND SPECIAL REPAIR TO BLDG NO P-554 AND P-556 IN CERTAIN UNITS AT MIL STN JAISALMER
2023_MES_583099_1
8268/22-23/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹93,400
Yes
6 Jul 2023
25 Feb 2023
27 Mar 2023
25 Feb 2023
25 Mar 2023
11 Mar 2023
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C-2, using 40 mm graded stone aggregate as in foundation concrete, mass concrete etc complete all as specified & directed by Engineer-in-charge.
Taking down chowkats or frames (without taking off shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down chowkats or frames (without taking off shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down shutters of any description area exceeding 2.00 Sqm each complete all as specified & directed by Engineer-in-charge.
S&F pressed steel frames (size105x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified & directed by Engineer-in-charge.
S&F pressed steel frames (size125x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified & directed by Engineer-in-charge.
S&F solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube suppling and fixing in opening as per specification and drawing complete all as specified & directed by Engineer-in-charge.
S & F for Plain, framed, panelled shutters 30 mm thick in second class hard wood (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed by Engineer-in-Charge.
S&F for 35 mm thick Glazed and skeleton shutters in second class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by Engineer-in-Charge.
S&F 30mm thick of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, uppling & fixing in the frame at site as per specification & drawing etc complete all as specified & directed by Engineer-in-Charge.
S&F steel window with side hung shutters fitted with box type hinges including MS handles, peg stays, MS guard bar made out of 10 mm squre bar, glazing bars dovetailed or welded for receiving glass and including painting with one shop coat of zinc chromate primer including cutting holes in wall for fixing the window lugs in PCC 1:2:4 type B1 using 20mm graded aggregate and making good the disturbed surfaces in CM (1:3) and applying two coats existing wall finishes to match with existing colour complete all as specified and directed by Engineering –in-Charge. Note : The rates quoted are inclusive of making good all the disturbed surfaces to match with the adjoining surfaces and necessary scaffolding etc up to 4th floor.
S&F aluminium (Die cast) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete all as specified & directed by Engineer-in-charge.
S&F mild steel butt hinges, medium weight cold rolled 100mm size complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F Plain sheet glass of 3.00 mm thick ordinary quality and glazing with oil putty and clips in squares not exceeding 0.50 Sqm in each pane complete all as directed by Engr-in-charge.
S&F for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples all as directed by Engr-in-charge.
Resecuring or easing & adjusting without taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each complete all as specified & directed by Engineer-in-charge.
Refixing in same opening shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each complete all as specified & directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified & directed by Engineer-in-Charge.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed by Engineer-in-Charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in subbase of floors & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-Charge.
M & L for ceramic tiles exterior grade 300x300x10 mm set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles laid over and including 15mm screed bed or bedding layer in CM (1:4) thick for laying in floor finishes all as specified and roughening of exc concrete surfaces complete all as specified & directed by Engineer-in-charge.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM 1:6 provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling of (size 600mm to 600mm) complete all as specified and directed by Engineer-in-charge.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in Skirting/dado over 10mm thick backing coat provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified and directed by Engineer-in-charge.
S&F glazed ceramic coloured tiles of size 350 x 250mm x 7mm /450mmx350mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including rendering 10mm thick as backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
M&L for Granite 20mm thick table rubbed and polished in steps, jambs, pillars, window cills, cooking platformsand like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixure of pigment to match with marble shade of Makrana white complete all as specified and as directed by the Engineer in Charge
Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engineer-in-charge.
M/L for rendering 15mm thick on brickwork or concrete on wall surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L rendering 5 mm thick on fair faces of concrete surface in ceiling in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of white wash over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of colour wash over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified & directed by Engineer-in-charge.
M&L for complete removal of the existing treatment on walls by scraping and washing down with water including making good the surfaces complete all as directed by Engr-in-Charge.
M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on walls complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of colour wash on walls complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated existing surfaces including cornices, plasterd or un plasterd surfaces by brooming down or steel wire brushing moulds, moss efflorescent salt and trading oil and gresy spots and applying one coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing path & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
M&L for 50 mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
S&F in repair cast iron nahani trap with CP grating including jointing to waste pipe in cement mortar, diameter of out let 75mm bore fixed in cement concrete type B1 (1:2:4) complete all as directed by Engr-in-Charge.
S&F in repairs of curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc and complet e all as directed by Engr-in-Charge.
S&F in repairs 75 mm long aluminium anodised hasp and staple safety type complete .
S&F in repairs tubular towel rail brass chromium plated 20mm dia D type 60cm long complete all as directed by Engr-in-charge.
M&L for 18/19 mm thick prelaminated particle board exterior grade , prelaminated one side with decorative choice lamination & other side balancing white lamination , fixed with screws to timber frame work including dismantling existing board of any description with scews complete all as specified and directed by Engineer-in-charge.
M&L for 2nd class hardwood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads, area not exc 3.00 Sqcm complete all as specified and directed by Engineer-in-charge.
S&F in repair 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed by Engineer-in-charge.
S&F in repair continiuos (piano) hinges of flap width 30mm , mild steel, bright finish or electogalvanised complete all as specified & directed by Engineer-in-charge.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
M&L for preparing old wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (Ordinary tint) complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old steel surface of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified & directed by Engineer-in-charge.
S&F 15mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings and fixed to walls and ceiling or laid in floors including taking down existing pipe complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings and fixed to walls and ceiling or laid in floors including taking down existing pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair, 15 mm bore, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia pillar taps cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repair, 15mm bore stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified & directed by Engineer-in-Charge.
S&F 15mm bore stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified & directed by Engineer-in-Charge.
S&F in repair brass chromium plated shower rose with swivel joints 125mm dia with 18mm dia chromium plated pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repair 15mm bore brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified & directed by Engineer-in-Charge.
S&F in repair, 20 mm bore gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks 500 litres capacity triple layered (White) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position all as specified in SSR Part I and including taking down old existing PVC tank of any description complete all as specified and directed by Engineer-in-charge.
S&F in repair 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures and taking down the old damaged cisterns and providing connections to WC and flush pipe without any damage to the existing fittings complete all as specified and directed by Engineer-in-charge.
S&F in repair vitreous china white wash down water closet pan, pedestal pattern including fixing bolts, plastic water closet seat and cover with recessed bottom with MS CP hinging device (excluding flushing cistern and flush pipe) complete all as specified & directed by Engineer-in-charge.
S & F in repair for pressure jet for western type water closet with PVC connection 600 t0 900 mm long including brass head screw and suitable washer complete all as specified & directed by Engineer-in-charge.
S&F in repair PVC connections 600mm long, 15mm size with PTMT nuts for WHB, flushing cistern, geysers etc complete all as specified & directed by Engineer-in-charge.
S & F plastic EWC seat cover, coloured closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed by Engineer-in-charge. (Make :- Cera model cat pt 2308 or equivalent in Appx 'C'list of makes.)
S&F in repair vitreous china wash basin white, flat back of size 550 x 400 mm white including waste fittings, brass, chromium plated, coupling, waste pipe, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe complete all as specified & directed by Engineer-in-charge.
M&L 75 mm size cast iron floor trap, with grating including jointing to waste pipe fixed in cement conrete (1:2:4) type B-1 complete all as specified & directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed by Engineer-in-charge.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410- W(Gde- E-250) quality-B complete all as specified & directed by Engineer-in-charge.
S&F in repair, 100mm bore cast iron (Spun) soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors all as specified & directed.
S&F in repair, 75mm bore cast iron (Spun) soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors all as specified & directed.
S&F in repair, 100mm bore (sand cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F in repair, 75mm bore (sand cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls complete all as specified & directed by Engineer-in-charge.
S&F CI Bends 100 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & directed by Engineer-in-charge.
S&F CI Bends 75 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & directed by Engineer-in-charge.
S&F CI 100mm Bends (any radius) with duck's foot or heel rest complete all as specified & directed by Engineer-in-charge.
S&F CI 100 mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified & directed by Engineer-in-charge.
S&F cast iron 100 mm dia P or S trap complete all as specified & directed by Engineer-in-charge.
S& F Cast iron 75 mm cowl complete all as specified & directed by Engineer-in-charge.
Dismantling of 100mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified & directed by Engineer-in-charge.
S&F soap dish brass chrome plated fancy type complete all as specified & directed by Engineer-in-charge.
S&F Shelf of PTMT shelf fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified & directed by Engineer-in-charge.
S & F grating round type 140mm of PTMT. (Minimum weight 50gms) complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete (reinforced) in roof, roof projection, chajja and similar works in any position complete all as specified & directed by Engineer-in-charge.
M&L for Renforcement cement concrete nominal mix 1:2:4 type B 0 using12.5 mm graded stone aggregate for chajja,roof projection,facies and similar works complete all as specified & directed by Engineer-in-charge.
Form work to chullah hoods, chajjas troughs and similar items including edges etc for rough finished flat surfaces all as specified & directed by Engineer-in-Charge.
M&L for mild steel TMT bars 6mm to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M & L anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & directed by Engineer-in-Charge.
M&L for providing APP based polymeric memrane weighing 3Kg/Sqm and Minm 3mm thick reinforced with polyster non wove fabric ( wt not less than 150 gm/sqm) laid over primed surface by forced application including bituminous primer confirming of IS 3384 applied @ 0.30 ltr/sqm and the APP membrane will be laid over CM 1:3 with water proofing compound as per manufacturer's instructions also the APP will be laid by torch application method over lap shall be 75mm on length of100 mm width side all as specified and as directed by Engr-in-charge. Four course roof treatment consist of as under - (i) Applying 1:3 CM with water proofing treatment (ii) Applying one coat of bituminous primer coating to IS 3384 @0.3 ltr/sqm (iii) Laying of APP membrane as specified per sqm thickness (iv) applying one coat of bitumen grade 85/25 @1.25 Kg/Sqm
M&L for fixing of cool roof tiles with 10mm thick screed bed with WPC (1:4) over terrace etc all as directed and specified by Engineer in charged. Note :- WPC shall be measeared and paid seperately
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking out carefully copper/GI earthing complete including GI pipe with copper or GI strip and removing materials and making good disturbed surface complete all as specified & directed by Engineer-in-charge.
Taking down Old unsv single pole and neutral enclosure with a two pin and earth plug and socket with 20 Amps MCB SP complete all as specified & directed by Engineer-in-charge.
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One Ceiling /Exaust fan point controlled by one switch.
(c) one bell/buzzer point controlled by one push botton.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
All as above item No 109.00 but M& L Point wiring with 1100 volts grade PVC insulated FR multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete all as specified & directed by Engineer-in-charge.
S&F switch piano, flush type, 6 amps, 230 volts, single pole, one way complete all as specified & directed by Engineer-in-charge.
S&F switch piano, flush type, 16 amps, 230 volts, single pole, one way complete all as specified & directed by Engineer-in-charge.
S&F switch piano, flush type, 16 amps, 230 volts, single pole, two way complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 6 pin & 16 amp flush typecomplete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge.
S&F bell push flush type 5 Amps complete all as specified & directed by Engineer-in-charge.
S&F bell AC single pole Ding Dong type 230 volt complete all as specified & directed by Engineer-in-charge.
S&F ceiling rose, three terminals PVC/Polycarbonate, isolated body complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required, suitable for TP/FP MCCB as incomer with MCCB 100A and with SP/TP MCB's as incoming MCCB FP 100 Amps, 25 KA complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the distrubed surface to match with existing specification complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 6 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length)
Supply & fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified & directed by Engineer-in-charge.
Supply and fixing of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-Charge.
S&F GI pipe bracket medium grade of 40 mm dia for building security light, clamps made of FI 40 mm x 6 mm Incl nuts, bolts & washers including two coats of synthetic enamel paint over a coat of zink chrome primer including taking down existing unserviceable bracket of any description complete all as specified and directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten 40 watt having Aluminium Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10% , Operating Voltage Range – 140 -270 Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM-80 / Test Report as Per Crompton Cat Part No. CIS-305-40-57-SL-DP-NWH or equivalent in Appx 'B' list of makes.
S&F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten, extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver, optic diffused type ENDURA LINER NEO including all electric connection with and including white flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
Supply & fix steel body heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
Taking down ceiling fan/exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position as directed complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
Supply & fix water heater storage type (Geyser) vertical type, inner container of capacity 25 ltrs, power Consumption 2.0 KW, BEE 5 star rated pressure rating >8 Bar electrically operated, AC 230 Volts, including as per site required Nos of fashner nuts required suitable size fixed in brick wall complete all as specified and directed. BEE 5 Star rated. Make: Havells Cat pot No : Monza DX GHWAMGSIN025 or equivalent Appx 'C' list of makes.
M & L for PVC connection pipe chromium plated 15 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/ cold water system complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 25x4 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 134.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with GI strip of 25X4 mm size complete all as specified and directed Engg-in-Charge.
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of pipe etc complete all as specified & directed by Engineer-in-charge.
Supply, laying and testing LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 Core complete all as specified & directed by Engineer-in-charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
M&L for drilling of 01 No of trial bore with suitable rig machine in any strata incl hard soil/bolders/rock etc. by Direct /Hammer/ mechanical percussion method below ground level , disposal of surplus soil with in 100 mtr keeping space for pea gravel packing and including lowering and extraction of casing pipes of 200mm dia up to 200 mtr depth below ground level. Development of trial bore by reaming in step from (a) 200mm to 350mm, (b) from 350mm to 450mm, (c) from 450mm to 550mm complete all as specified & directed by Engineer-in-charge. Note:- a) For lowering and extraction of casing pipes include all mechanical equipment shall be arranged by the contractor. b) In case of any mechanical damage due to failure of borewell the contractor will have no claim what so ever on this account. (c) Supply only casing pipe will be measured and paid separately. Fixing/ lowering charge deemed inclusive in the quoted rate.
Supply only MS casing pipe of 200 mm dia and thickness 8 mm with all fittings complete all as specified & directed by Engineer-in-charge. Note :- Supply only casing pipe will be measured and paid separately. Fixing/ lowering charge deemed inclusive in the quoted rate.
Labour only Additional cost for slotted pipe of 200 mm dia in lieu of casing pipe of 200 mm dia in between as per the water table complete all as specified & directed by Engineer-in-charge.
M&L for filling surrounding of casing pipe by pea gravel complete all as specified & directed by Engineer-in-charge.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water complete all as specified & directed by Engineer-in-charge.
S&F MS reducer, bail plug, well cap, MS etc strip for centring, MS iron clamps, electric logging and simple strata box complete all as specified & directed by Engineer-in-charge.
Labour for yield test for the borewell by continuously pumping for 16 hours to determine safe pumping yield complete all as specified & directed by Engineer-in-charge. Note:-Neccessary bowser for yield test from test area to disposal of water to be arranged by contractor at the own cost.
Supply, installation, testing & commissioning borewell submersible pump set of stainless steel material, high reliability nitril rubber bushes and wear rings ensure long life of pump even in sandy water CED coated cast iron components for long life and rust free operation, non-overloading power characterristics suitable for 415 V, 3 phase system having capacity 20 HP (15 kw) head range upto 300 Mtr, flow range 2400 -60 LPM, outlet 80mm, suitable for 200mm dia bore well (Casing pipe size 200 mm) complete all as specified & directed by Engineer-in-charge.
Supply, install, testing and commissioning of LT motor control panel AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 52 , suitable for outdoor use, with bottom cable entry with suitable cable glands structure made of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs , with sloping canopy at top, double hinged doors at front and back with suitable locking arrangement , Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated
M&L GI column pipe heavy grade 6M long 3" bore with welded heavy duty flanges at both ends including a coat of anticorrosive paint complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 80 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 50 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20 mm bore 'medium grade' galvanised with all GI fittings (such as bends, elbows, tees, conectors, short pieces, back nuts, unions, caps & plugs etc) fixed complete to wall and ceiling or laid in floor including cutting, threading and testing complete all as specified & directed by Engineer-in-charge.
Supply and fix Air valve, with by-pass Arrangement, 50 mm (2”) dia complete all as specified & directed by Engineer-in-Charge.
S&F 50 mm bore gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F 20 mm bore gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F submersible cable PVC insulated and PVC sheathed industrial 1100 Volts grade multistranded copper conductor of size 10 Sqmm flat 3 Core complete all as specified & directed by Engineer-in-charge.
M/s Shree Construction Company
AMBEY MAA CONSTRUCTION COMPANY
M/s J B Construction Company
star electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .