| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC A 12 SECTOR 59 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.2 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹1.4 Cr+₹25.0 L (20.9%)Rejected-Finance SHOP NO 135 KHANNA MARKET SOUTH DELHI 110003 | NEW DELHI | DELHI | 110003 | ₹1.4 Cr+₹25.0 L (20.9%) | L2 | Rejected-Finance L2 Bidder |
| 3 | L3₹1.6 Cr+₹39.4 L (33.0%)Rejected-Finance 203 GURU CHAMBERS 2501 8 BEADONPURA KAROL BAGH DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | ₹1.6 Cr+₹39.4 L (33.0%) | L3 | Rejected-Finance L3 Bidder |
| 4 | L4₹1.6 Cr+₹43.1 L (36.0%)Rejected-Finance 100 FEET ROAD AHMEDABAD CITY GUJARAT 380059 INDIA | AHMADABAD | GUJARAT | 380059 | ₹1.6 Cr+₹43.1 L (36.0%) | L4 | Rejected-Finance L4 Bidder |
Tender Value
₹2.1 Cr
EMD Value
₹3.2 L
Closing Date
29 Jun 2023, 12:00 pmClosed
AGM Electrical Engg.
Project office Jabalpuir Airport
Provision of Boom Barriers Tyre Killers and Hydraulic Bollards at various locations at Jabalpur Airport Jabalpur Madhya Pradesh
2023_AAI_156448_1
Security System
Open Tender
Electrical Works
Works
120 days
Jabalpur Airport
Please refer to tender Document
12 documents required · 12 mandatory
₹1,180
₹3.2 L
23 Aug 2023
7 Jun 2023
30 Jun 2023
7 Jun 2023
29 Jun 2023
7 Jun 2023
7 Jun 2023 - 14 Jun 2023
Amount
Supply, Installation, Testing and Commissioning of “Crash Rated Electro- Hydraulic Bollard Systems” as per DOS/ ASTM/PAS68 /IWA 14:2013 standards with minimum K4 crash rating (Individual bollard should be physically crash tested from reputed testing agency) . Bollards should be of minimum 900 mm height and 275 mm dia made up of heavy steel cylindrical weldment. The bollards should have an Axle load bearing capacity of Road / Base plate of minimum 20 tons with a provision of Operational alert with Blinking LED, Audio signal during operation along with all other accessories like provision of Manual operation during power off, Hydraulic Power Pack / Unit with accumulator, safety interlock detector and Control panel having incomer MCCB of suitable rating , control and logic circuit placed inside IP66 weather proof enclosure, with lock and key arrangement. The enclose should be equipped with LED Light at the Top indicating serviceability of electric systems. Work includes all civil and electrical works each as excavation of existing PQC / bitumen road, disposal of excavated material, fixing the bollards systems, concrete work and making good the some after installation of bollards, provision of Self priming sump pump of suitable rating to drain the accumulated water, supply & laying of cables in suitable HDPE/DWC/GI Pipes (upto 30 Meter) and interconnection, complete as per the technical specification and as per directions and to the complete satisfaction of the Engineer-in-charge. (Cost includes each and every item mentioned above.) A) No of Bollards in Combination- 06 Bollards
Supply, Installation, Testing and Commissioning of “Crash Rated Electro- Hydraulic Bollard Systems” as per DOS/ ASTM/PAS68 /IWA 14:2013 standards with minimum K4 crash rating (Individual bollard should be physically crash tested from reputed testing agency) . Bollards should be of minimum 900 mm height and 275 mm dia made up of heavy steel cylindrical weldment. The bollards should have an Axle load bearing capacity of Road / Base plate of minimum 20 tons with a provision of Operational alert with Blinking LED, Audio signal during operation along with all other accessories like provision of Manual operation during power off, Hydraulic Power Pack / Unit with accumulator, safety interlock detector and Control panel having incomer MCCB of suitable rating , control and logic circuit placed inside IP66 weather proof enclosure, with lock and key arrangement. The enclose should be equipped with LED Light at the Top indicating serviceability of electric systems. Work includes all civil and electrical works each as excavation of existing PQC / bitumen road, disposal of excavated material, fixing the bollards systems, concrete work and making good the some after installation of bollards, provision of Self priming sump pump of suitable rating to drain the accumulated water, supply & laying of cables in suitable HDPE/DWC/GI Pipes (upto 30 Meter) and interconnection, complete as per the technical specification and as per directions and to the complete satisfaction of the Engineer-in-charge. (Cost includes each and every item mentioned above.} A) No of Bollards in Combination- 03 Bollards
Supply, Installation, Testing and Commissioning of “Crash Rated Electro- Hydraulic tyre killer" of blocking width of minimum 3.0 meter . The system shall consist of hydraulic automatic spike barrier made of galvanized steel . The spike should be of a nominal dia of 25mm, with spacing between spikes not more then 200 mm at an angle of 60 , suitable to work on 230V / 415V, 50Hz AC supply along with all other accessories like provision of Manual Operation during power off, Hydraulic Power Pack / Unit with accumulator, safety interlock detector and Control panel having incomer MCCB of suitable rating, control and logic circuit placed inside IP66 weather proof enclosure, with lock and key arrangement. The enclose should be equipped with LED Light at the Tope indicating serviceability of electric systems. Work includes all civil and electrical works such as excavation of existing PQC / bitumen road, disposal of excavated material, fixing the Spike systems, concrete work and making good the same after installation of Spike arrestor, provision of Self priming sump pump of suitable rating to drain the accumulated water, supply & laying of cables in suitable HDPE/ DWC/ GI Pipes (upto 30 Meter) and interconnection, complete as per the technical specification and as per directions and to the complete satisfaction of the Engineer-in-charge. (Cost includes each and every item mentioned above).
Supply, Installation, Testing and Commissioning of “Crash Rated Electro- Hydraulic tyre killer" of blocking width of minimum 7.0 meter . The system shall consist of hydraulic automatic spike barrier made of galvanized steel . The spike should be of a nominal dia of 25mm, with spacing between spikes not more then 200 mm at an angle of 60 , suitable to work on 230V / 415V, 50Hz AC supply along with all other accessories like provision of Manual Operation during power off, Hydraulic Power Pack / Unit with accumulator, safety interlock detector and Control panel having incomer MCCB of suitable rating, control and logic circuit placed inside IP66 weather proof enclosure, with lock and key arrangement. The enclose should be equipped with LED Light at the Tope indicating serviceability of electric systems. Work includes all civil and electrical works such as excavation of existing PQC / bitumen road, disposal of excavated material, fixing the Spike systems, concrete work and making good the same after installation of Spike arrestor, provision of Self priming sump pump of suitable rating to drain the accumulated water, supply & laying of cables in suitable HDPE/ DWC/ GI Pipes (upto 30 Meter) and interconnection, complete as per the technical specification and as per directions and to the complete satisfaction of the Engineer-in-charge. (Cost includes each and every item mentioned above).
Supplying, installing,testing and commissioning, Automated Metal Boom Barrier of approved make and quality including barrier aluminium bar 4000 mm long with mobile support, 24V DC motor with control unit in box, double built in LED flashing light, double spring to counter balance movement, entire body of unit and all aluminium work finished in UV resistant epoxy powder coating in approved shade, all accessories such as gears and levers, encoder for obstacle detection, manual lock release feature by key, three station push button, pair of photocells with anodised aluminium vertical mounting, built in control panel & motor, key operated lever release system with a cover plate, rubber end plug for aluminium bar, barrier cabinet, barrier mounting base etc. Work include all the necessary minor civil work if required. Supply & laying of cables of suitable rating in suitable HDPE/ DWC/ GI Pipes (upto 30 Meter) and interconnection complete as per site requirement , technical specifications and as per directions and to the complete satisfaction of the Engineer-in-charge.
Supply and fixing of 4 ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 Amp tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's and MCCB as incomer (but without MCB's and MCCB as incomer) as required.
Supply of 3.5 core ,50 sq.mm of XPLE insulated PVC sheathed ,aluminium conductor armoured power cable of 1.1 KV grade conforming to IS: 7098 (Part -I),1988 ammended upto date
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp 16 KA 4P MCCB
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, single pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 amps rating, 415 volts, 10 kA, “C” curve, 3 Pole miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying & laying of PE80, PN6, 63 mm dia HDPE pipe ISI marked as per IS: 4984/2016 with latest amendment up to date along with all necessary accessories like coupler and other required accessories etc. direct in ground (750mm below ground level) including excavation and refilling the trench complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1 . 1 KV grade of following size in existing Hume pipe/HDPE Pipe/GI Pipe etc as required. Above 35 sq. mm and upto 95 Sq mm.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/recess/existing cable tray as required. Above 35 sq. mm and upto 95 Sq mm.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 50 sq. mm .
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 50 sq. mm .
Supply ,Installation,testing & commissioning of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3mtr longh 50mm dia of outer shell (MS) with the 25mm dia inner shell (MS) of 80-100 microns galvanized earth electrode filled with highly conducting metallic compounds with the permanent sealing at both the ends with the lead terminal of 32X10mm size at the top along with 50 Kgs of Chemical mixture of Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound shall be less than 20%. The Chemical compound should be tested and certified by any International accredited or BIS( Bureau of Indian Standards) accredited laboratory. The earth electrode shall be dully tested & certifed by CPRI (Central Power Research Institute), Govt. of India. The chemical earth electrode manufacturers should be an ISO 9001:2008 & ISO 14001: 2004 certified organization. The Earth pit should be covered with heavy duty polyplastic weather proof chamber etc. as required & approved by the Engineer in Charge.
Providing and fixing 25 mm X 5 mm G.I. strip on surface / recess/ existing HDPE Pipe/existing GI Pipe for connections etc. as required.
All Inclusive Comprehensive Maintenance Contract of each 06 combination Crash Rated Electro- Hydraulic Bollard Systems mentioned at BOQ Item No.1.00 after completion of One year Defect Liability Period.
1st year after DLP.
2nd year after DLP.
3rd year after DLP.
4th year after DLP.
5th year after DLP.
All Inclusive Comprehensive Maintenance Contract of each 03 combination Crash Rated Electro- Hydraulic Bollard Systems mentioned in BOQ Item No. 2.00 after completion of One year Defect Liability Period.
1st year after DLP.
2nd year after DLP.
3rd year after DLP.
4th year after DLP.
5th year after DLP.
All Inclusive Comprehensive Maintenance Contract of each 3.0 meter Crash Rated Electro- Hydraulic tyre killer mentioned in BOQ Item No.3.00 after completion of One year Defect Liability Period.
1st year after DLP.
2nd year after DLP.
3rd year after DLP.
4th year after DLP.
5th year after DLP.
All Inclusive Comprehensive Maintenance Contract of each 7.0 meter Crash Rated Electro- Hydraulic tyre killer mentioned in BOQ Item No. 4.00 after completion of One year Defect Liability Period.
1st year after DLP.
2nd year after DLP.
3rd year after DLP.
4th year after DLP.
5th year after DLP.
All Inclusive Comprehensive Maintenance Contract of each 4000 mm long Automatic Boom Barrier mentioned in BOQ Item No.5.00 after completion of One year Defect Liability Period.
1st year after DLP.
2nd year after DLP.
3rd year after DLP.
4th year after DLP.
5th year after DLP.
FORTUNA CONTROL AND AUTOMATIONS PVT LTD
S Aditya Impex Pvt Ltd
Swaraj Secutech Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .