Karnataka Power Transmission Corporation Limited
Hridya CR
Dismantling, Transportation (to and from), Repair, Testing, Erection and Commissioning of Sick Power Transformer of rating 150MVA, 220/66/11kV, CGL make, Sl. No. BH-9196-4 YOM 2006 lying at 220/66/11kV SRS Peenya R/s on Total Turnkey basis
KPTCL/2023-24/EL/WORK_INDENT69
KPTCL/2023-24/EL/WORK_INDENT69
Open
Electrical
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Circle BMAZ North Bengaluru
18 documents required · 17 mandatory · 1 optional
The Bidder shall have experience of minimum 05 (five) years in manufacturing / repairing, testing and commissioning of same or higher voltage class of Power Transformer here in tendered involving designing, manufacturing and replacement of faulty windings in case of Power Transformer which has been repaired for any of the Government / public sector power utility in India which should have been in satisfactory continuous operation for at least 02 (two) years prior to the date of opening of the tender.
The Bidder should have executed either manufacture or repair on total turnkey basis.(involving designing, manufacturing and replacement of faulty windings of Power Transformer) of a same or higher voltage class in the past 10 ( Ten) years ending last day of the month previous to the one in which tender is invited for any of the Government / public sector power utility for any one of the following value of work. which shall have rendered satisfactory service of at least 02 (two) years continuously, a minimum of 60 percent of the value of the tendered amount against each of 01 (One) distinct work orders on total turnkey basis or b)a minimum of 50 percent of the value of the tendered amount against each of 03 (three) distinct work orders on total turnkey basis.
The Bidder shall have technically qualified work force with domain knowledge relating to design of Power Transformer including quality control and shall have infrastructure, testing and erection facilities and capacity to execute the works.
The Bidder should have their own repair shop with all the facility such as Crane, Oven, winding machines, etc., required for carrying out necessary repairs on Power Transformers.
he Bidder shall have necessary facilities at his own works for carrying out all routine tests mentioned in this specification including facility to carry out special tests namely Impulse Test and Temperature Rise Test on a repaired Power Transformer as prescribed in the latest IS:2026/1977 or any relevant standard as applicable for testing of repaired Power Transformer. The testing facilities shall have testing and measuring instruments calibrated by National Accreditation Board for Testing and Calibration Laboratories (NABL). Valid calibration reports of Testing and measuring instruments shall be uploaded to the e-portal
The Bidder should have established own workshop to accommodate and repair EHV Transformers, and should maintain dust free environment for winding works and should have the essential equipment like, 40 Tons EOT crane for capacities up to 31.5 MVA and 100 Tons EOT crane for capacities beyond 31.5 MVA. At least 6 KL oil filtration plant. Winding machines for winding of Transformer windings. Insulating paper wrapping machine. Vacuum drying chamber to accommodate the active parts of the tendered Transformer. Fully Automatic Digital Insulation Tester (5 KV) .Automatic Digital Capacitance and Tan delta measuring instrument. Digital winding resistance measurement instrument. Digital turns ratio meter. Power analyzer. Adequate rating of cables for measuring load losses and impedance as per IS.2026. Sufficient no. of sensors for measuring top and bottom oil temperatures shall be made available for testing of Transformers, and other essential T&P Digital Flow meter for measuring the quantity of Transformer oil during filling. Generators/Transformers and Capacitor Banks and Instrument transformers of adequate rating for conducting Load loss, No load loss, separate source, DVDF and Temperature rise Tests. adequate rating of Impulse Generator for conducting Lightening Impulse Test
Bidders shall have adequate financial stability and status to meet financial obligation pursuant to the scope of this assignment and shall meet the following minimum criteria Minimum Average Annual Turnover (MAAT) of the Bidder for best 03 (three) years out of last preceding 05 (five) financial years (on the date of tendering) ending on March shall not be less than 100% of the amount put to tender
PAN CARD
Profit and loss statement/ Balance sheet of last 5 years duly attested by CA
The performance of the Transformer repaired / supplied by the Bidder in the past shall be a vital factor in determining the responsiveness of the tenderer. In case of substantial failure of the Transformers repaired / supplied by the Bidders in the past contracts, failure to adhere to the completion schedules or to meet the technical requirements and guarantees and, if the Transformer so repaired / supplied and installed were affected by persistent operational problems, damages, breakdowns etc., owing to design inadequacies, workmanship defects etc., the Bids shall be rejected.
GST registration
Not disqualified declaration
No deviation certificate
Power of attorney
Letter of undertaking
The firm should have sound financial capability. The solvency required will be 100% of the amount put to tender. The solvency certificate shall be from a nationalized or scheduled Bank and issued within a period 12 months from the final date of submission of tender
Company registration certificate
The Bidder shall upload the proof of having possessed the above T&P equipment along with valid calibration certificate for testing / measuring equipment to the e-portal for verification
The Bids shall be accompanied by Bid security/Earnest Money Deposit (EMD) at 01 (One) PERCENT of the amount put to tender rounded off to a multiple of Rs.10 on the higher side.
₹5,000
₹2.2 L
17 Oct 2023
17 Oct 2023
10 Nov 2023
25 Oct 2023
21 Oct 2023
Repairs to faulty 150MVA 220/66kV CGL make power transformer failed at SRS Peenya R/s
Dismantling, Transportation (to and fro), Repair, Testing, Erection and commissioning of sick Power Transformer of rating 150 MVA, 220/66/11KV, CGL MAKE, SL. No BH-9196-4 YEAR OF MANUFACTURE 2006 LYIN...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
150MVA Transformer CGL make at 220-66-11kV SRS Peenya.pdf
Techno-Commercial Worksheet • 0.08 MB
tender_document-_tr_Peenya 150MVA.docx
Tender Document • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .