Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹33.4 L+₹1.8 L (5.83%)Rejected-AOC | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹33.8 L+₹2.2 L (6.98%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹36.0 L+₹4.5 L (14.1%)Rejected-AOC 0001 000 KACHARI ROAD RAMAIPATTI MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | UTTAR PRADESH | 231001 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | Rejected-Technical RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Not Found in order |
Tender Value
₹41.7 L
EMD Value
₹83,400
Closing Date
3 May 2022, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINTENANCE OF SUBMERSIBLE PUMP SET MONOBLOCK PUMP SET AND CENTRIFUGAL PUMP SETS CONNECTED ELECTRIC CONTROL PANELS AND INTERNAL WIRING INCLUDING CONNECTED ITEMS OF WATER SUPPLY INSTALLATIONS OF CVD AREA PIRU VIHAR SIGNAL GROUP DAD NSB III AREA
2022_MES_517088_1
8222/GE/WS/D-08/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹83,400
Yes
19 Dec 2022
7 Apr 2022
5 May 2022
7 Apr 2022
3 May 2022
21 Apr 2022
Amount
Disconnecting electric connections from LT control panel and starter of submersible pump set of size 2 to 15 HP and removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back and lowering of same pump in bore well after repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing complete all as specified and as directed.
Labour for Opening the submersible pump set for repairing, rewinding and assembling the pump set including insulating material of any size of capacity 2 to 15 HP complete all as specified and as directed by Engg-in-charge.(Different make and size of copper winding and other spare parts will be measured under relevant items of this shedule as supply only) Note :- Copper winding wire of appropriate gauge shall be measured and paid separetely
Supply Only following spare parts for submersible pump set of capacity 2 HP to 15 HP.
Bearing Bush.
Rotor Sleeve.
Water seal and cable seal
Thrust bearing
Revolving Disc
CI Connection piece
Motor GM Sand Guard
Sealing Ring
CI upper Housing
CI lower Housing
Labour only for Rotor Sleeve turning and grinding
Labour only for Remetling of Rotor, turning and balancing
Flange upper with stud and nut
Flange lower with stud and nut
Labour only for Repairing of stator stamping
Seal bush
CI Motor Base
Thrust plate
SS coupling
Coupling key
Stud and Nuts for connection piece
Labour only for balancing of rotor
T Bolt with Nut
LNK Bolt SS
Submersible Cable joint
CI Suction Chamber
CI Stage bowl
EPV Impeller
EPV Stage Bowl
Guide Bush
GM DOWL Bush
SS DOWL Sleeve
Inter ring
CI DOWL Piece
CI NRV body
Impeller key
SS pump shaft per stage
Remattling of GM Impeller and Turning
Pump Sand Guard
SS Distance Sleeve
EPV Defuser
Hook bolt with nut
GM Neck Ring
Mild steel stud with nut
Wire mesh
Drain plug
Supply and fixing in replacement GI Nipple with flange welded, heavy duty 40 x 300 mm size complete all as specified and as directed.
All as per serial item No 4.00 here-in-before but of size 50 x 300 mm
All as per serial item No 4.00 here-in-before but of size 80 x 300 mm
Supply only GI column pipe, heavy grade, class 'C', 50 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
Supply Only GI column pipe, heavy grade, class 'C', 80 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
S&F in replacement of submersible cable of size 2.5 Sqmm 3 Core. 1100 Volt complete all as specified and as directed.
All as per serial item No 9.00 here-in-before but cable of size 4 Sq mm 3 core , 1100 Volts .
All as per serial item No 9.00 here-in-before but cable of size 6 Sq mm 3 core, 1100 Volts .
M & L for preparation of surfaces for painting of existing submersible pump sets of capacity 2 to 15 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 50mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 50mm bore column pipe complete all as specified and directed.
Supply and fixing in replacement of Mild steel clamps in Mild steel flat of size 80 mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 80mm bore column pipe complete all as specified and as directed.
Supply and fixing in replacement of MS Casing Cover, heavy duty, made out of Mild steel sheet not less than 6mm thick suitable for 150 mm bore pipe complete all as specified and as directed .
Supply and fixing in replacement of MS Casing Cover, heavy duty, made out of Mild steel sheet not less than 6mm thick suitable for 200-300 mm bore pipe complete all as specified and as directed .
Supply and fixing in replacement PVC insulated multistranded copper conductor wire 1100 volt, single core of size 2.50 Sq mm complete all as specified and as directed.
All as per serial item No 17.00 here-in-before but cable of size 4 Sq mm 1100 Volts .
All as per serial item No 17.00 here-in-before but cable of size 6 Sq mm, 1100 Volts .
Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of following capacities from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .
Opening the electric induction motor of following capacity including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material to make it functional complete all as specified and as directed . Note:- Copper winding wire of approprioate guage will be measured in supply only.
Disconnecting and De-coupling the Centrifugal pump of following capacity from foundation after opening /cutting the rusted nuts, bolts etc including transporting the pump to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and as directed.
Opening the centrifugal pump of following capacity, repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed. Note:- Spare Parts required shall be measured & paid spaerately.
Supply and fixing in replacement of spare parts for Centrifugal pump of 20-30 HP Cap. Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned .
CI Impeller
Pump shaft SS (AISI-410)
Remetling of pump shaft, turning and balancing
CI Shaft sleeve
CI Casing wear ring
CI interstage ring
CI stuffing box bush
CI Gland Plate
Lantern ring
Eye bolt with nut
Gasket Packing Sheet
GM Impeller Nut
Gland packing champion
Impeller key
Coupling key
Water liquid deflector
CI bearing cartridge
CI bearing plate
Coupling nut
MS Stud with nut
Supply and fixing in replacement of spare parts for Centrifugal pump of 40-50 HP Cap. Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned.
CI Impeller
pump shaft SS (AISI-410)
Remetling of pump shaft, turning and balancing
CI Shaft sleeve
CI Casing wear ring
CI interstage ring
CI stuffing box bush
CI Gland Plate
Lantern ring
Eye bolt with nut
Gasket Packing Sheet
GM Impeller Nut
Gland packing champion
Impeller key
Coupling key
Water liquid deflector
CI bearing cartridge
CI bearing plate
Coupling nut
MS Stud with nut
Supply and fixing in replacement of spare parts for Centrifugal pump of 60-75 HP Cap. Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned.
CI Impeller
Pump shaft SS (AISI-410)
Remetling of pump shaft, Turning and balancing
CI Shaft sleeve
CI Casing wear ring
CI interstage ring
CI stuffing box bush
CI Gland Plate
Lantern ring
Eye bolt with nut
Gasket Packing Sheet
GM Impeller Nut
Gland packing champion
Impeller key
Coupling key
Water liquid deflector
CI bearing cartridge
CI bearing plate
Coupling nut
MS Stud with nut
Supplying and assembling super enamelled copper winding wire of appropriate gauge suitable upto 125 HP Centrifugal Pump Set and upto 15 HP capacity submersible pump sets.
Supplying and Fixing in replacement of CI Sleeve on Bearing Housing of following capacity
Supplying and Fixing in replacement of Terminal Connection Plate of following capacity
Supply and fixing spare tyre for coupling type TC/P/011 after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing spare tyre for coupling type TC/P/013 after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing spare tyre for coupling type TC/P/014 after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing spare tyre for coupling type TC/P/015 after taking down/out as existing at site complete all as specified and as directed.
Supply and fixing spare tyre for coupling type TC/P/019 after taking down/out as existing at site complete all as specified and as directed.
Disconnecting of electrical connections from panel and taking out induction monoblock pump and transporting to work shop for Repair and Re-installation in exiting position after repair of capacity upto 5-15 HP
Opening the monoblock pump and taking out the burnt winding wire cleaning the slots, rewinding the monoblock pump with super enamalled copper winding wire and assembling complete upto 15 HP Note:- Spare Parts required shall be measured & paid spaerately
Supply and fixing in replacement of spare parts for Monoblock pump of upto 15HP Capacity. Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.
CI Impeller
GM Shaft sleeve
Mechanical Seal
Water Seal
Water liquid deflector
Gland packing champion
Gland packing sheet
Impeller Nut
MS Stud with nut
Supply and Fixing in replacement of Ball Bearing 6205
Supply and Fixing in replacement of Ball Bearing 6305
Supply and Fixing in replacement of Ball Bearing 6306
Supply and Fixing in replacement of Ball Bearing 6307
Supply and Fixing in replacement of Ball Bearing 6308
Supply and Fixing in replacement of Ball Bearing 6309
Supply and Fixing in replacement of Ball Bearing 6310
Supply and Fixing in replacement of Ball Bearing 6311
Supply and Fixing in replacement of Ball Bearing 6312
Supply and Fixing in replacement of Ball Bearing 6313
Supply and Fixing in replacement of Ball Bearing 6314
Supply and Fixing in replacement of Roller Bearing NU-314
Supply and Fixing in replacement of Roller Bearing NU-316
Supply and Fixing in replacement of Double Ball Bearing 3307
Supply and Fixing in replacement of Double Ball Bearing 3309
Supply and fixing in replacement 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
Supply and fixing in replacement 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
S & F in replacement of thermal over load relay type ML 1, starter type ML, relay range 10-16Amp complete all as specified and as directed
S & F in replacement of thermal over load relay type ML 2, starter type ML, relay range 20-32 Amps complete all as specified and as directed.
S & F in replacement of thermal over load relay type ML 3, starter type ML, relay range 28-42 Amps complete all as specified and as directed
S & F in replacement of thermal over load relay type MN 5, starter type MNX, relay range 45-75 Amps complete all as specified and as directed.
Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 10-120 HP and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
Supply and Fixing in replacement MS base channel of size as exists including cutting, welding and making hole, applying two coats of synthetic enamel paint over a coat of red oxide primer including dismounting existing Centrifugal pump motor set and taking out old unservicable existing MS Base chennel complete all as specified and as directed.
Supply and fixing in replacement CI foot valve of following size, flanged type, including Nut and Bolts washer and rubbers, as per IS : 4038 complete all as specified and as directed. Note :- Flanged joints including jointing material shall deemed to be included in the unit rates.
100 mm dia
150 mm dia
Supply & fixing in replacement of Cast iron Non Return valve without by pass arrangement ,Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
100 mm dia
150 mm dia
Supply & Fixing in replacement DOL starter type MN-16 in DOL relay range 9-15 Amps complete all as specified and as directed.
Supply & Fixing in replacement Fully Automatic Star-Delta starter type ML/MN either in FASD ML-2 or MN-45 FASD complete all as specified and as directed
Supply & Fixing in replacement automatic star - delta starter type ML in FASD ML 3 complete all as specified and as directed.
Supply & Fixing in replacement automatic star - delta starter type ML in FASD ML 4 complete all as specified and as directed
Supply and fixing in replacement PVC insulated multistranded copper conductor wire of following size, single core, 1100 volts complete all as specified and as directed.
Supply and fixing in replacement Amp Meter Digital type 0 to 100 Amp of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement VoltMeter Digital type 0 to 500 Volts of size 96 x 96 mm complete all as specified and as directed.
Supply and fixing in replacement of Indicating light RYB LED type complete all as specified and as directed.
Supply and fixing in replacement of current transformer ratio 100/5 complete all as specified and as directed.
Supply and fixing in replacement of current transformer ratio 200/5 complete all as specified and as directed.
Supply and fixing in replacement of current transformer ratio 400/5 complete all as specified and as directed.
Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia , 450 mm long complete all as specified and as directed.(including breaking of hard standing foundation)
Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 20-30 HP complete all as specified and as directed.
Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 40-75 HP complete all as specified and as directed.
Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 90-125 HP complete all as specified and as directed.
Supply,Laying, jointing, Testing and commisioning of MS Pipe of following size, as per IS:1239 with and including MS flange, 16 mm thick welded for drilling of 16 mm dia bolts, nuts, washers, rubber gaskets etc laid in trenches complete all as specified and as directed.
Supply & Fixing in replacement MS Flange of following sizes, 16 mm thick, duly welded on ends of MS pipe including necessary cutting to existing MS pipe or in new MS pipe complete all as specified and as directed .
M&L for flange joint for following size of Pipe with rubber or fibre gasket including Nut, Bolts and washers etc complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site and 50 mm deep complete all as specified and as directed.
One light point controlled by one, one way switch .
One Ceiling Fan/Exhaust fan point controlled by one, one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps on the Independent board.
All as per item No- 2 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
M&L for Switch piano flush type single pole, one way 5A.
M&L for Switch piano flush type single pole, one way 16 Amp
M&L for Socket outlet, 2 in 1, 3 pin 5A flush type
M&L for Socket outlet, 2 in 1, 5 pin 16A flush type
M&L for ceiling rose 3 terminal PVC/ Polycarbonate isolated body complete all as specified and directed.
M&L for Decorative ultra slim round profile LED lightning fixture 20W,6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unsv light fitting complete all as specified and as directed.
Supply and fixing in replacement 60 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including making connections with GI pipe 0.6mtr angle braket fixing on wall and connectng to ceiling rose with apropriate wire complete all as specified and directed.
Supply and fixing exhaust Fan, heavy Duty 450 mm sweep, 1400 RPM Single pole 230V , 50Hz complete all as specified
M&L for MCB Distribution 6 way, SPN, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
All as per item no 88 here in before but MCB DB SPN 8 way
M&L for MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
M&L for MCB SPN 40 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
M&L for MCB SP 6-32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series including taking down old unsv MCB complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified ans as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 25×4mm as earthing lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed.
Supplying, fixing, testing and commissioning of feeder pillar box, indoor type cubical shape, 3 Phase, 4 Wire, Aluminium bus bar of 200 Amps with PVC sleeve suitable for phases and neutral, made out of CRCA sheet 2.0 mm thick ,factory fabricated ,CPRI approved , powder coated ,dust and vermin proof , with provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
Incoming:
(a) MCCB TPN 63 Amps, 35 kA rupturing capacity - 01 Nos
Outgoing:
(a) MCCB TPN 32 Amps, 35 kA rupturing capacity - 02 Nos
(b) MCB SPN 32 Amps, 10 kA rupturing capacity - 02 Nos
(c) DOL Starter, L&T Cat Part No. MN 25 DOL - 02 Nos
(d) Indicating Lamps (set of three) - .1 No
Supplying, fixing, testing and commissioning of feeder pillar box, indoor type cubical shape, 3 Phase, 4 Wire, Aluminium bus bar of 200 Amps with PVC sleeve suitable for phases and neutral, made out of CRCA sheet 2.0 mm thick ,factory fabricated ,CPRI approved , powder coated ,dust and vermin proof , with provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
Incoming:
(a) MCCB TPN 125 Amps, 36 kA rupturing capacity - 01 Nos
Outgoing:
(a) MCCB TP 63 Amps, 35 kA rupturing capacity - 03 Nos
(b) MCB SPN 32 Amps, 10 kA rupturing capacity - 02 Nos
(c) FASD Starter, L&T Cat Part No. MN 32 FASD - 03 Nos
(d) On-load Changeover Switch 200 Amps - 01 Nos
(e) Indicating Lamps (set of three) - .1 No
Supplying, fixing, testing and commissioning of feeder pillar box, indoor type cubical shape, 3 Phase, 4 Wire, Aluminium bus bar of 200 Amps with PVC sleeve suitable for phases and neutral, made out of CRCA sheet 2.0 mm thick ,factory fabricated ,CPRI approved , powder coated ,dust and vermin proof , with provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
Incoming:
(a) MCCB TPN 100 Amps, 25 kA rupturing capacity - 01 Nos
Outgoing:
(a) MCCB TP 32 Amps, 35 kA rupturing capacity - 03 Nos
(b) MCB SPN 32 Amps, 10 kA rupturing capacity - 02 Nos
(c) FASD Starter, L&T Cat Part No. MN 25 FASD - 02 Nos
(d) On-load Changeover Switch 100 Amps - 01 Nos
(e) Indicating Lamps (set of three) - .1 No
M&L for Pressure gauge(dial dule scale), dial size 63mm, S.S. Tube, dry type , bottom connection , pressure measuring range 0-07 kg/cm2 (100 PSI) including taking down old unservicable pressure gauge complete all as specified and as directed.
M & L for Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc with two coat of synthetic enamel paint over a coat of red oxide primar and incl lifting handle and taking out the old unsv valve chamber cover complete all as specified and as directed.
Taking down cement plaster or cement lime plaster on PCC/Stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
Rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfaces finished even & smooth.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc.
M&L Brick work with sub class 'B' old size bricks bricks straight or cured on plan exceeding 6 m mean radius built in cement mortar 1:6
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 300mm x 200mm, 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition and dismantling concrete in ground floors and pavings n exc 15 cm thickness below or above ground level.
M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed
Hacking out old broken glass any thickness, size, quality or description from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads including S&F 3 mm thick plain sheet glass ordinary quality in square not exceeding 0.5
Laying only electric cable, screened PVC bedded, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve including taking out existing unserviceable cable complete all as specified and directed for following sizes: - Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items , (Cable shall be issued under sch 'B" free for fixing only)
25 Sqmm x 3.5 core
35 Sqmm x 3.5 core
50 Sqmm x 3.5 Core
Supply and fixing & installation in replacement of perforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging system and other accessories including painting of cable tray of complete all as specified.
M&L for fabrication (welding work ) of MS Header/ any size upto 300mm MS pipe at various pump house site for connection of pipe, arresting leakges on header complete all as specified and directed.
M & L for heat shrinkable LT 1100V straight through joint suitabel for aluminium conductor cable of size 25 to 50 sqmm complete all as specified and directed.
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of cables including M& L for PCC (1:2:4) type B-I (with 20 mm graded aggregate) as in coping, grouting, finished even and smooth without using extra cement as on brick work/flooring complete making good the existing surface complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-40 Grade with grey cement and no pigments, over 25 mm thick sand cushioning complete all as specified and as directed. Note : Sand Cushioning shall be measured and paid under respective item.
M&L for chequered cement conc. Tiles 20cm*20cm*20mm & pigment set, jointed and pointed in neat cement slurry laid over 20 mm thick scred bedding in cm(1:6)
Supply & Fixing in replacement MCCB 160-200Amps, 4 pole, 415 V, breaking capacity 36 KA lcu at 415 V, AC 50 Hz.
All as per item No 21 here in before but 3 pole MCCB 100-125 Amps, 415V, breaking capacity 30 kA
All as per item No 22 here in before but 3 pole MCCB 63-80 Amps,415 V, breaking capacity 30 kA
Supply and fixing in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and as directed
Supply and fixing in replacement 3 pole power contactor ML-2, 32-40 Amps suitable for fixing in existing panel complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML 1.5 relay, range 10-16 Amp complete all as specified and as directed.
Supply and fixing in replacement of over load relay, type ML-2 starter range 9-14 Amps complete all as specified and as directed.
All as per serial item No 27.00 here-in-before but of range 13-21 Amps
All as per serial item No 27.00 here-in-before but of range 20-32 Amps
Supply and fixing in replacement single phase preventor, type VSP-II complete all as specified and as directed.
S&F in replacement of analog type time switch FM 1/ Quartz daily 240 VAC, flush mounting, 50 Hz Code No. J648F1
Extension/ development of borewell for drilling not less than 250 mm bore hole by DTH method to any depth below the ground level in any kind of rock/soil upto 100 mtr deep including disposal of surplus soil to a distance not exc 50 mtr away complete all as specified and as directed. Note : 1) In case of incountering rock prior to 30 mtr depth from ground level the decission of the Garrison Engineer for reboring shall be final and binding. Specific order in writing shall be issued by Garrison Engineer for reboring and the quantities shall vary accordingly. 2) cost of transportation of DTH plant is included in the unit rate.
Supplying, lowering & fixing into bore 200 mm dia MS casing pipe, heavy duty as per IS-4270, minimum 5.4 mm thick ERW having Duly welded both sides socketed ends complete all as specified and as directed.
Supplying, lowering & fixing into bore hole 200 mm dia MS casing pipe, heavy duty as per IS -4270 minimum 5.40 mm thick ERW slotted tube having 1.5 mm to 3mm slot having socketed ends complete all as specified and as directed.
M&L for development of bore well of any capacity and size at the pressure 10 kg/sqcm to 15 kg/sqcm by diesel engine driven air compressor of capacity 620 cfm includiing air pipe and connected items to improve the yield of tube well complete all as specified and as directed.
Supplying and packing pea gravel of size 3.00 mm to 6.00 mm around casing pipe complete all as specified and as directed.
M&L for painting synthetic enamel paint to pipe surface of any description over 10 cm in width or girth, not otherwise described complete all as specified and as directed
S & F Fully automatic stat delta motor starter in sheet enclosure type, rating AC 3 duty 415V 50 Hz 3 phase, ML-1.5/MN-25 FASD relay range 13-21 Amps including taking down old starter complete complete all as specified and as directed.
Supply & Fixing in replacement Fully Automatic Star-Delta starter type ML/MN either in FASD ML-2 or MN-32 FASD complete all as specified and as directed.
M&L for CI water meter Woltman type magnetic drive class-B flanged suitable for 80mm dia pipe including taking dow old unserviceable water meter complete all as specified and as directed.
All as per serial item No 48 here-in-before but for 100 mm dia pipe.
Supply & fixing , install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, copper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter, Ammeter and cable lugs etc .
(a) Copper bus bar with PVC sleeve rating 200 amps for Phase & 200 Amp for neutral - 01Set.
(d) Phase indicating lamps LED type ( RYB) 01 Set
(e) Incoming MCCB 125 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No
(f) Outgoing MCCB 63 Amp 3-Pole 18 kA with adjustable thermal and fixed magnetic release - 01 Nos
(g) FASD Stater ML-2 or MN-25 FASD-01 Nos
(h) Analog time switch -01 No
(j) Single phase preventer-01 No
M&L for development of bore well of any capacity and size at the pressure 22 kg/sqcm to 25 kg/sqcm by DTH Machine of capacity 1200 CFM including air pipe and connected items to improve the yield of tubewell complete all as specified and as directed. Note : The rate deemed to include the cost of Transportation of machine and minimum 1 Hrs of running.
Supply and installation of flanged ends strainer/dirt box, PN-10 with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of following sizes complete all as specified and as directed.
80 mm bore
100 mm bore
An amount of Rs 133595.00 shall be deducted from BOQ on account of schedule of credit
Yadav Enterprises
B.R. Enterprises
KUSHAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .