| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.0 L+₹1.2 L (15.6%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹9.6 L+₹1.8 L (23.4%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹10.0 L+₹2.2 L (28.6%)Rejected-Finance 55 SHALL TOKUNA JANGALNAD PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical EXPIRED DD, ONE TIME VERIFICIATION LETTER NOT UPLOADED |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
24 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
CERTAIN REPAIR TO GEYSER,EXHAUST FANS,CEILING FANS AND OTHER MISC ITEMS AT 8 FBSU
2021_MES_484014_1
GE (AF) AWA-27/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹24,000
Yes
27 Dec 2021
27 Oct 2021
26 Nov 2021
27 Oct 2021
24 Nov 2021
11 Nov 2021
60 days
Amount
Disconnecting electrically dismantling and taking out electric energy meter any type and capacity and depositing to MES Store Yard complete all as specified and directed .
Fixing only electronic energy meter single phase/three phase up to 60 Amps as obtained from serial item No 01 above after carrying out repair work in same or other location including sealing proper lead seals and wires as required complete all as specified and directed.
Replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 run of 4Sqmm and 1run of 4sqmm cable includindg casing caping of suitable size shall be measured as one running metre.
Replacement of wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed, surface complete all as specified and directed. Note :- 2 run of 6Sqmm and 1run of 6sqmm cable includindg casing caping of suitable size shall be measured as one running metre.
Replacement of wiring for submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10 sqmm complete drawn in and includindg casing caping ISI marked of suitable size and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :-2 run of 10Sqmm and 1run of 10sqmm cable includindg casing caping of suitable size shall be measured as one running metre.
Replacement of wiring for submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 4 x 10 sqmm complete drawn in and includindg PVC conduit ISI marked of suitable size and its accessories along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface,complete all as specified and directed. Note :-4 run of 10Sqmm and 1run of 10sqmm cable includindg PVC conduit of suitable size shall be measured as one running metre.
Supply and fixing in replacement Meter box IP-65 for 3 meters with triangular locks of size 300x450x170 mm transparent LID of Cat part No Mi 0300 T of Hensel or equivelent to HPL /Indoasian including cutting and chases wall and removing old metal or wooden box and fitted new box and match the disturbed surface with existing specification by required PCC and plastering work complete all as specified and directed.
Replacement of sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB TP/TPN as incomer and MCB SP as outgoing complete all as specified and directed.
Replacement of MCBs, SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, C curve type, complete all as specified and directed.
Replacement of MCBs, TPN, 40-63 Amps, 415 volts, 10 kA rupturing capacity, C curve type, complete all as specified and directed.
Replacement of plastic fan capacitor with wire terminals of capacity 2.5 Mfd, 230 volts AC, complete all as specified and directed.
Replacement of plastic fan capacitor with wire terminals of capacity 3.15 Mfd, 230 volts AC, complete all as specified and directed.
Replacement of plastic fan capacitor with wire terminals of capacity 4.0 Mfd, 230 volts AC, complete all as specified and as directed.
Replacement of rubber reel suitable for ceiling fan/Ex fan/cabin fan of any type/make/size, complete all as specified and directed.
Replacement of down rod of 1' height fabricated out of MS pipe 10 mm dia heavy duty duly painted with white paint suitable to hang ceiling fan of any description, make and model, complete all as specified and directed.
Supply only in replecement of heavy gauge ceiling fan hanging clamp fabricated out of MS flat with nut bolts with split pin, complete all as specified and directed.
LED light fitting 1x16 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1&2 and IP 65 protection with die cast aluminum hosting with heat resistant toughened glass with LED tube light fixtures , driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed.
Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and directed.
Fan dimmer 6 electronic dimmers, 450W, 250V flush type on the existing phenolic laminated sheet etc., complete all as specified and directed.
Overhauling of fan of any type and any make by opening, cleaning, greasing, oiling of fan motor after testing the faults including replacement of minor parts and re-assembling, complete all as specified and directed. Note: Spare parts and and winding shall be measured and paid separately.
Replacement of ball bearing suilable for ceiling/exhaust/cabin/ wall/pedestrial fan of any type/make/size, complete all as specified and directed.
Replacement of bush suitable for ceiling/exhaust/cabin/wall/ pedestrial fan of any type/make/size, complete all as specified and directed.
Transportation of rotor of fan to work shop for rewinding/repair work and returning back to site complete all directed. Note:- Rewinding will be measured and paid separately.
Removing old/burnt winding, cleaning of slots/pitches by using cleaning material by removing the insulating materials and then rewinding (i.e renewal of winding) the fans with appropriate/same gauge of super enamelled copper wire and insulating material, varnishing, drying the winding for adequate period to remove the moisture content and strengthening the winding and testing to the speed and flow of the fans any make, complete all as specified and directed for the following type of fans :-
Ceiling fan 1200/1400 mm sweep
Exhaust fan 300/380/450 mm sweep
Wall mounted/cabin fan 400/450 mm sweep
Pedestal fan 400/450mm sweep
Replacement of fan blades heavy duty of any make suitable for exsiting pattern and colour scheme including screws, Complete all as specified and directed for following type of fans:-
Ceiling fan 1200/1400 mm sweep (set of three blades)
Exhaust fan 300/380/450 mm sweep
Wall mounted/cabin fan 400/450 mm sweep
Pedestal fan 400/450mm sweep
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit in PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate, RCC cover 80mm thick in RCC (1:2:4) type B-0 reinforced with 8mm dia TMT bars at 15cm centre to centre both way, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing on completion, complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of galvanized iron wire 4mm dia, complete all as specified and directed.
Replacement of 25mm dia medium grade rigid non metallic PVC conduit alongwith its fixing accessories and making good to the disturbed surface to match the existing, complete all as specified and directed.
Replacement of 25mm wide casing caping ISI marked medium gradealongwith its fixing accessories and making good to the disturbed surface to match the existing, complete all as specified and directed.
Taking down carefully electric geyser of any type and capacity complete opening of the geyser and replacing the defective parts including disconnecting electric and water supply connection and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. Note :- (i) Any accessories found unserviceable that shall be replaced under respective items of this Schedule. (ii). Supervisor collect the complaints daily from office and feedback daily basis, and provide the complaint slip book as per sample.
Supply only, syphon assembly with rubber gasket, including nuts, bolts, washers etc following capacity of geysers, complete all as specified and directed:-
50 Litres capacity geysers.
25 Litres capacity geysers.
Mild steel galvanised iron medium grade water tubing 15mm bore with screwed & socket joints, with all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to wall and ceiling or laid under floors etc. making holes, as in repairs complete all as specified and directed.
Supply only inner tank, vessel made of copper sheet 22 gauge , ISI marked factory made for suitable pressure of following capacity, complete all as specified and directed:-
50 Litres capacity .
25 Litres capacity.
Supply and fixing of heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample) complete all as specified and directed. Make-Microne/Globo.
Description all as per serial item No 33 above, but of capacity 2 KW.
Description all as per serial item No 33 above, but of capacity 3 KW.
Supply only glass wool heat insulation superior quality suitable for geyser of capacity 25/35/50 Litres, complete all as specified and directed.
Supply and fixing of PVC insulated shethed cable 3 core flexible copper conductor of size 2.5 sqmm fire proof, complete all as specified and directed. Make: Plaza/Nicco/Havels/gloster
Supply and fixing of drain plug for geyser, complete all as specified and directed.
Supply and fixing of safety valve for geyser, complete all as specified and directed.
Supply and fixing , 3 pin top, 16 Amps capacity, complete all as specified and directed. Make: Cona /SSK/Leader.
Supply and fixing of indicator lamp for geyser of any type as per existing in geyser, Complete all as specified and directed.
Supply and fixing of thermostat switch suitable for 50/35/25 litres capacity geysers as per sample, Complete all as specified and directed.
Supply and fixing of push type thermostat switch suitable for 50/35/25 litres capacity geysers as per sample, Complete all as specified and directed.
Spray painting to water heather of capacity 25 litres to 50 litres capacity by spraying two coats of synthetic enamel paint after filling cavities with filler and cleaning dust etc complete all as specified and directed by Engineer –in-Charge incl writing MES number.
Taking down existing unserviceable outer cover of geyser of capacity 25 litres and supply and fix new outer cover made out of 1mm thick mild steel sheet duly spary painted with two coats of synethetic enamel paint over a coat of red oxide, zinc chrome primer, , complete all as specified and directed.
Description all as per Serial item No 46 above, but of capacity 50 litres.
Taking down unserviceable bottom cover plates (2 half) and supply and fix with new bottom cover plates with machine columns of geyser of capacity 25/50 litres, complete all as specified and directed.
Replacement MCB single pole 240 volts any rating from 20 amps, with rupturing capacity 10 KA, class c ,including providing thimble for out going cables, complete all as specified and as directed. Make:- Legrand/Havells/Hanger
PVC connection mesh type for cold/Hot water as per sample, Complete all as specified and as directed .
15 Amps, three pin socket suitable for matel clad, Complete all as specified and as directed. Make-Schenider/Legrand/Hagger
Stop valve cast copper alloy cromium plated fancy type screwed ends with butterfly or crunch handle of size 15mm bore ISI marked, complete all as specified and as directed.
Single pole and nuetral enclosure with two pin and earth plug and socket complete with one single pole MCB up to 20 amp ,240 volts, complete all as specified and as directed.
Replacement of old unserviceable anchor bolt with anchor bolt 12mm 100mm long complete all as specified and as directed. Note- Achor bolt shall be grouted with hammer drill only.
Note :- An amount of Rs. 17,527.50 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
ORISON ENTERPRISES
M/S BASHIR AHMAD AND SONS
M/S SHABIR AHMAD SHAH AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .