Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance 301 VARDHAMAN CHAMBER II VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | -1.31% | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹7.0 L (4.60%)Admitted-Finance | -0.20% | ₹1.6 Cr+₹7.0 L (4.60%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical FIRST FOOR SCF 1 SECTOR 17 FARIDABAD FARIDABAD FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | - | - | - | Rejected-Technical Technical Disqualified |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
8 Feb 2022, 2:00 pmClosed
Zonal Manager, NWZ
Zonal Manager, North Western Zone, 5th Floor, Plot No. 148, Sector-44, Gurugram, Haryana
Special Repairs of HVAC System at AIIA, Sarita Vihar, New Delhi
2022_NPCC_102645_1
NPCC/336-AIIA-HVAC Spl.Repair/751 Dated 21.01.2022
Open Tender
Civil Works
Percentage
120 days
New Delhi
Please refer Tender documents.
5 documents required · 5 mandatory
₹17,700
Yes
National Projects Construction Corporation Limited
₹3.1 L
Yes
28 Feb 2022
22 Jan 2022
9 Feb 2022
22 Jan 2022
8 Feb 2022
22 Jan 2022
Amount
Non Schedule Item
Supply of Chilled water temperature sensor cable
Supply of SCPM Card for Carrier Chiller 30HXC
Supply of Oil Filter Internal for Carrier Chiller 30HXC
Supply of Oil Filter External for Carrier Chiller 30HXC
Supply of Drier Core for Carrier Chiller 30HXC
Supply of Compressor oil for Carrier Chiller 30HXC
Supply and Installation of Phase Sequence Relay
Repairing of compressor including replacement of bearings for Carrier Screw Chiller
Supply and Installation of TQ Valve for Carrier Chiller 30HXC
Leakage detection, rectification , pressure testing and recommissioning of Compressor
Oil Analysis for Carrier Chiller from Carrier Approved Laboratory
Supply, Installation, Testing and Commisoning of display control panel for Hot Water Generator
Supply, Installation, Testing and Commisoning of Step controller relay
Supply and Fixing of temperature sensor
Supply and Installation of 25 KW Heater
Supply and Installation of 15 KW Heater
Supply and Installation of water flow switch
Supply and Installation of water level sensor
Supply and Installation of strainers made out of SS sheet with 3.0 mm perforation to be inserted in the Y stariners
200 mm dia
150 mm dia
Supply and Installation of pedal type flow switches in condenser water and chilled water inlet lines
Supply and Installation of Liquid Filed Stain less Steel pressure gauge
Supply and Installation of dial type Stain less Steel temperature gauge
Replacement of Bearings for pump
Replacement of Mechanical seal for pump
Supply and Fixing of PVC Fills 600mm X 300mm X 150 mm
Supply and Fixing of PVC End Caps 63 mm
Supply and Fixing of PVC splash Caps 63 mm
Supply and Fixing of PVC Nozzles 40 mm
Supply and applying Fiber resin compound
Supply and fixing Steel screws
Dismantling of cooling tower for repairing/ replacement of cooling tower base frame and ressembling/reinstallation of the cooling tower with new hardware as per requirement
Supply, Installation, Testing and Commissioning of Actuator for motorized valves
Supply and Fixing of Prefilter 610*610*50 mm with aluminum frame
Supply and Fixing of Prefilter 500*500*50 mm with aluminum frame
Supply and Fixing of Prefilter 400*400*50 mm with aluminum frame
Supply and Installation of cellulose evaporative pads for air washers
Removing and disposal of old insulation from chilled water pipe lines and prepapring the surface for new insulation
Removing and disposal of insulation from supply air ducts and preparing the surface for new insulation
Supply and laying of 28 Gauge alluminum sheet cladding
Supply and Fixing of Micro Vee Filter 2000 CFM
Supply and Fixing of Micro Vee Filter 1000 CFM
Supply and Fixing of HEPA Filter 2000 CFM
Supply and Fixing of HEPA Filter 1000 CFM
Supply , Installation, Testing and commissioning of Extension panel for chillers consisting of 630 Ampere Aluminum TPN bus bar, single core flexible copper cable connections from bus bar to the motor terminals
Relaying and retermination of main incomer power cables to chillers
Complete overhauling and re-commissioning of water softening plant installed in fire pump room
M/s G.D. Enterprises
M/s G.D. Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_111762.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .