Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC WARD NO 26 PREM NAGAR BALAGHAT DISTT BALAGHAT M P | BALAGHAT | BALAGHAT | MADHYA PRADESH | 481001 | ₹4.5 Cr | L1 | Accepted-AOC Bidder Item Rate Quoted being lowest |
| 2 | L2₹4.6 Cr+₹13.0 L (2.91%)Rejected-Finance KARANJA GHA TAL KARANJA DIST WARDHA | KARANJA | WARDHA | MAHARASHTRA | ₹4.6 Cr+₹13.0 L (2.91%) | L2 | Rejected-Finance Bidder Item Rate Quoted being highest |
| 3 | L3₹4.9 Cr+₹42.3 L (9.45%)Rejected-Finance | ₹4.9 Cr+₹42.3 L (9.45%) | L3 | Rejected-Finance Bidder Item Rate Quoted being highest |
| 4 | L4₹5.1 Cr+₹65.2 L (14.6%)Rejected-Finance NAWRANG NIVAS SHULELAL MARG SINDHI COLONY GONDIA TAH DISTT GONDIA | GONDIA | MAHARASHTRA | 441601 | ₹5.1 Cr+₹65.2 L (14.6%) | L4 | Rejected-Finance Bidder Item Rate Quoted being highest |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
17 Nov 2020, 5:30 pmClosed
Superintending Engineer PMGSY Nagpur Region Nagpur
Office of the Superintending Engineer PMGSY Nagpur Region Nagpur PWD Campus Bandhkam Sankul Civil Line Nagpur-01
1-Aajangaon To Dhawalapur Road 2-Sawali To Hatla Road 3-Borgaon To Chikhali Masod Road
2020_MMGSY_619361_8
T.No.04/S.E./ADB/NAG/2020-21
Open Tender
Civil Works
Item Rate
548 days
Katol
Prequalification as per mentioned in SBD Section -2
2 documents required · 2 mandatory
₹16,800
Online
₹2.6 L
24 Feb 2021
26 Oct 2020
18 Nov 2020
26 Oct 2020
17 Nov 2020
26 Oct 2020
26 Oct 2020 - 31 Oct 2020
Amount
Bill No. 1 Site Clearance, Dismantling and Earth Works
Cleaning grass and removal of rubbish up to a distance of 30m outside the periphery of the area as per Technical Specification Clause 201
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3
Construction of embankment with approved materials deposited at site from raodway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift and lead upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (A) with a lead upto 1000 m (Item No. 3.4 )
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with all lead as per Technical Specification Clause 303.1
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of granular sub-base by providing Grading-I material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.( using crushable screening )
Construction of 50 mm thick Modified Penetration Macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
Providing and applying tack coat on prepared surface heating by glamesin boiler and spraying bitumen set footed in bitumen boiler on b.t. surface @ 2.5 kg /10 sqm (VG-30) Bitumen rates are considered to arrive at rates (PWD SSR item no. 3.30 p.no. 34) (Above M.P.M.)
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat) (Item No. 5.9 (i) ) Bitumen (S-65) VG-30
Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B, as per Technical Specification Clause 510
Providing and laying cement concrete Wearing Course M-30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. ( I.No. 2.5/P.No. 9 )
(B) Cement Concrete
(C) Reinforced Cement Concrete
Removing all types of Hume Pipes and Stacking within a lead of 1000m including Earth work and Dismantling of Masonary works as per technical Specifications Clause 202
A) Upto 600mm Ø Hume Pipe
C) above 900mm Dia
Earthwork in excavation for foundation of structures upto 3m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by mechanical means.
I. Ordinary soil, ii) Upto 3 m depth by mechanical means
II. Ordinary rock (not requiring blasting)
Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. For open Foudnation
A-1-ii) FOR ABUTMENT
A-2-ii) FOR PIER
A-3-ii) FOR RETURN
Filling annular space around footing in rock as per Technical Specification Clause No.1203.4.3.
Providing and laying in situ/ ready mix controlled M-25 cement concrete of trap/ granite/ quartzite/ gniess metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/ steel formwork, compacting by vibrating, finishing in CM 1:3 and curing etc complete (Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (panmixer). with fine agreegates of required specifications (Natural sand/ VSI sand finely washed etc ) (IV) R.C.C grade M 25
Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment , wing wall , return wall to the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.
Rubble filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9
Providing concrete for plain cement concrete M-10 in foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (Using 43 Grade OPC Cement)
Plain cement concrete Grade M-15 in substructure complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807, 1202 and 1204 (Using 43 Grade OPC Cement)
Plain cement concrete Grade M-15 in substructure complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807, 1202 and 1204 (Using 43 Grade OPC Cement)
Plain cement concrete Grade M-20 in substructure complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807, 1202 and 1204 (Using 43 Grade OPC Cement)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 (II) R.C.C M 25
Providing and laying in situ M-20 R.C.C. of trap /granite /quartzite /gneiss metal for RCC work,of ballast walls, kerbs, box returns with reversible Drum Type mixer.With natural sand etc. including scaffolding, compaction, formwork finishing and curing complete. (excluding reinforcement). R.C.C grade M 20
Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 50) at 2.5 m interval and three rows of 50 mm dia steel pipes ( light ) including fixing in position on bridge deck complete as per drawing and technical specification Clause 1208.2
Providing tar paper bearing of approved quality in proper size etc. complete.
Expansion Joint with 25mm thick bituminous pad
Providing and fixing Granite / Marble tablet of 15mm to 18mm thickness, including making groove in wall / concrete surface filling joints with slurry, curing, polishing, rounding edges, as required cleaning etc. complete. of size and description as per detailed drawings including embosseing & fitting in 1:2 C.M. border.
Excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by manual means. (Item No. 9.1 A )
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. 1000 mm dia.
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (I) Stone/Boulder
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106.. 600 mm dia.
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Supplying fitting and placing TMT bar reinforcement in superstructure complete as per drawings and technical specification Clauses 1002, 1010 and 1202
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202.
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade 200m Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade Boundary Pillar/ Local Stone of standard design as per IRC: 25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704.
Painting lines, dashes, arrows etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
Providing & Constructing CC M-15 TBM Stone of size 0.30x0.30x0.75m including excavation, CC M-10 for foundation, painting, lettering with MMGSY Logo, curing, finishing etc. complete.
Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 Village Name Board
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 600 mm Equilatral and Triangle
Providing and fixing a typical MMGSY Citizen information board as per specifications provided on detailed drawing of NRRDA having size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in concrete block of 60 x 60 x 75 cm size . Information as provided in drawing of NRRDA shall be displayed on a CR/ GI sheet of appropriate thickness and fixed at steel frame with 5mm steel plate. All lettering and printing arrows border etc. will be painted with ready mixed synthetic enamel with ready mixed synthetic enamel paint of superior quality in required shade and clolured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat epoxy paint as per drawing.Vlllage Name Board
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia.Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings
Bill No. 1 Site Clearance, Dismantling and Earth Works
Cleaning grass and removal of rubbish up to a distance of 30m outside the periphery of the area as per Technical Specification Clause 201
Dismantling of Flexible Pavements By Mechanical Means Dismantling of flexible pavements and disposal of dismantled materials upto all lead , stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202. Bituminous Courses
Excavation for roadwork in soil with hydraulic excavator of 0.9 One Cubic Meter bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3
Construction of embankment with approved materials deposited at site from raodway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (A) with a lead upto 1000 m
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with all lead as per Technical Specification Clause 303.1
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of granular sub-base by providing Grading-I material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.
Construction of 50 mm thick Modified Penetration Macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
Providing and applying tack coat on prepared surface heating by glamesin boiler and spraying bitumen set footed in bitumen boiler on b.t. surface @ 2.5 kg /10 sqm (VG-30) Bitumen rates are considered to arrive at rates (Above M.P.M.)
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat) Bitumen (S-65) VG-30
Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B, as per Technical Specification Clause 510
Providing and laying cement concrete Wearing Course M-30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. ( I.No. 2.5/P.No. 9 )
(B) Cement Concrete
(C) Reinforced Cement Concrete
Removing all types of Hume Pipes and Stacking within a lead of 1000m including Earth work and Dismantling of Masonary works as per technical Specifications Clause 202
C) above 900mm Dia
Earthwork in excavation for foundation of structures upto 3m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by mechanical means.
I. Ordinary soil, ii) Upto 3 m depth by mechanical means
II. Ordinary rock (not requiring blasting)
Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. For open Foudnation
A-1-ii) FOR ABUTMENT
A-2-ii) FOR PIER
A-3-ii) FOR RETURN
Filling annular space around footing in rock as per Technical Specification Clause No.1203.4.3.
Providing and laying in situ/ ready mix controlled M-25 cement concrete of trap/ granite/ quartzite/ gniess metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/ steel formwork, compacting by vibrating, finishing in CM 1:3 and curing etc complete (Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (panmixer). with fine agreegates of required specifications (Natural sand/ VSI sand finely washed etc ) (IV) R.C.C grade M 25
Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment , wing wall , return wall to the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 ii) Rubble filling (For B.C. Soil)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. P.C.C grade M 15.
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 II) P.C.C grade M 20 i) Nominal mix (1:1:5:3)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 (II) R.C.C M 25
Providing and laying in situ M-20 R.C.C. of trap /granite /quartzite /gneiss metal for RCC work,of ballast walls, kerbs, box returns with reversible Drum Type mixer.With natural sand etc. including scaffolding, compaction, formwork finishing and curing complete. (excluding reinforcement). R.C.C grade M 20
Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 50) at 2.5 m interval and three rows of 50 mm dia steel pipes ( light ) including fixing in position on bridge deck complete as per drawing and technical specification Clause 1208.2 (Item No. 13.8 / P.No. 53)
Providing tar paper bearing of approved quality in proper size etc. complete.
Expansion Joint with 25mm thick bituminous pad (Item No. 13.16
Providing and fixing Granite / Marble tablet of 15mm to 18mm thickness, including making groove in wall / concrete surface filling joints with slurry, curing, polishing, rounding edges, as required cleaning etc. complete. of size and description as per detailed drawings including embosseing & fitting in 1:2 C.M. border.
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. 1000 mm dia.
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 (I) Stone/Boulder
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106.. 600 mm dia.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (Item No. 11.4 (i) P.C.C grade M 10 i) Nominal mix 1:3:6
Supplying fitting and placing TMT bar reinforcement in superstructure complete as per drawings and technical specification Clauses 1002, 1010 and 1202
Supplying fitting, and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawing and technical spcifications Clauses 1002, 1005, 1010 and 1202 (Item No. 12.7 P.No. 50)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II) P.C.C grade M 15 - i) Nominal mix (1:2.5:5) (Item No. 11.4(ii)
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii) Kilometre Stone (precast)
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade 200m Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Construction of Rounded Hump Type Speed Breaker as per IRC : 99 (1988) for general traffic as per specification, including painting, fixing cautionery boards etc. complete and as directed by Engineer-in-Charge.
Painting lines, dashes, arrows etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
Providing & Constructing CC M-15 TBM Stone of size 0.30x0.30x0.75m including excavation, CC M-10 for foundation, painting, lettering with MMGSY Logo, curing, finishing etc. complete.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 Village Name Board
iv) 800 mm x 600 mm Rectangular
ii) 600 mm Equilateral Triangle
Providing and Fixing 'Logo' of PMGSY/MMGSY Project Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA- P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the fra-me and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted (Item No. 10.16 (A)
Providing and fixing a typical MMGSY Citizen information board as per specifications provided on detailed drawing of NRRDA having size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in concrete block of 60 x 60 x 75 cm size . Information as provided in drawing of NRRDA shall be displayed on a CR/ GI sheet of appropriate thickness and fixed at steel frame with 5mm steel plate. All lettering and printing arrows border etc. will be painted with ready mixed synthetic enamel with ready mixed synthetic enamel paint of superior quality in required shade and clolured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat epoxy paint as per drawing.Vlllage Name Board
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia.Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings
Bill No. 1 Site Clearance, Dismantling and Earth Works
Cleaning grass and removal of rubbish up to a distance of 30m outside the periphery of the area as per Technical Specification Clause 201
Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lift and lead as per Technical Specification Clause 302.3
Construction of embankment with approved materials deposited at site from raodway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with all lift , transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 (A)
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with all lead as per Technical Specification Clause 303.1
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of granular sub-base by providing Grading-I material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. using crushable screening)
Construction of 50 mm thick Modified Penetration Macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
Providing and applying tack coat on prepared surface heating by glamesin boiler and spraying bitumen set footed in bitumen boiler on b.t. surface @ 2.5 kg /10 sqm (VG-30) Bitumen rates are considered to arrive at rates (Above M.P.M.)
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat) Bitumen (S-65) VG-30
Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type B, as per Technical Specification Clause 510
Providing and laying cement concrete Wearing Course M-30 grade Excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. ( I.No. 2.5/P.No. 9 )
(B) Cement Concrete
Removing all types of Hume Pipes and Stacking within a lead of 1000m including Earth work and Dismantling of Masonary works as per technical Specifications Clause 202 ( I.No. 2.13 / P.No 10 )
C) up to 600mm Dia
Earthwork in excavation for foundation of structures upto 3m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by mechanical means.
I. Ordinary soil, ii) Upto 3 m depth by mechanical means
II. Ordinary rock (not requiring blasting)
Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. For open Foudnation (Item No. 11.1(A)
A-1-ii) FOR ABUTMENT
A-2-ii) FOR PIER
A-3-ii) FOR RETURN
Filling annular space around footing in rock as per Technical Specification Clause No.1203.4.3
Providing and laying in situ/ ready mix controlled M-25 cement concrete of trap/ granite/ quartzite/ gniess metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/ steel formwork, compacting by vibrating, finishing in CM 1:3 and curing etc complete (Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (panmixer). with fine agreegates of required specifications (Natural sand/ VSI sand finely washed etc ) (IV) R.C.C grade M 25
Providing and laying filter media with granular crushed aggregates as per specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment , wing wall , return wall to the full height compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Backfilling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete. (Item No. 16.7) / P.No. 61)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 II) P.C.C grade M 20 i) Nominal mix (1:1:5:3)
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 (II) R.C.C M 25
Providing rubble filling in foundation trenching as per drawing & Technical Specification Clause 305.3.9 (Item No. 11.2 (II))
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.8
Earthwork in excavation for foundation of structures upto 3m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by mechanical means.
Providing and laying in situ M-20 R.C.C. of trap /granite /quartzite /gneiss metal for RCC work,of ballast walls, kerbs, box returns with reversible Drum Type mixer.With natural sand etc. including scaffolding, compaction, formwork finishing and curing complete. (excluding reinforcement). R.C.C grade M 20
Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 50) at 2.5 m interval and three rows of 50 mm dia steel pipes ( light ) including fixing in position on bridge deck complete as per drawing and technical specification Clause 1208.2
Providing tar paper bearing of approved quality in proper size etc. complete.
Expansion Joint with 25mm thick bituminous pad
Providing and fixing Granite / Marble tablet of 15mm to 18mm thickness, including making groove in wall / concrete surface filling joints with slurry, curing, polishing, rounding edges, as required cleaning etc. complete. of size and description as per detailed drawings including embosseing & fitting in 1:2 C.M. border.
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106. 1000 mm dia.
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106.. 600 mm dia.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1106
Supplying fitting and placing TMT bar reinforcement in superstructure complete as per drawings and technical specification Clauses 1002, 1010 and 1202
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202.
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II) P.C.C grade M 15 - i) Nominal mix (1:2.5:5)
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. P.C.C grade M 15.
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii) Kilometre Stone (precast)
Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Reinforced cement concrete M-15 grade 200m Stone (Precast) of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Painting lines, dashes, arrows etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
Providing & Constructing CC M-15 TBM Stone of size 0.30x0.30x0.75m including excavation, CC M-10 for foundation, painting, lettering with MMGSY Logo, curing, finishing etc. complete.
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 Village Name Board
iv) 800 mm x 600 mm Rectangular
ii) 600 mm Equilateral Triangle
Providing and Fixing 'Logo' of PMGSY/MMGSY Project Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA- P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the fra-me and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted (Item No. 10.16 (A)
Providing and fixing a typical MMGSY Citizen information board as per specifications provided on detailed drawing of NRRDA having size of 2500 x 1150 mm with 75 mm square or round steel tube for support fixed in concrete block of 60 x 60 x 75 cm size . Information as provided in drawing of NRRDA shall be displayed on a CR/ GI sheet of appropriate thickness and fixed at steel frame with 5mm steel plate. All lettering and printing arrows border etc. will be painted with ready mixed synthetic enamel with ready mixed synthetic enamel paint of superior quality in required shade and clolured as mentioned in detailed drawing. All sections of framed posts and steel tube shall be painted with primer and two coat epoxy paint as per drawing.Vlllage Name Board
Road Delineators: Supplying and installation of delineators (Roadway Indicators, Hazard markers, Object markers) 80 to 100 cm high above ground level, painted black and white in 15cm wide strips, fitted with 80x100mm rectangular or 75mm dia.Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C. 79 and the drawings
Pralhad Mohanlal Motwani
Supreme Startech Pvt Ltd
Ankit Fatehsingh Chouhan
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .