| 1 | L1₹21.6 LAccepted-AOC | ₹21.6 L Quoted ₹23.0 L | L1 | Accepted-AOC SINCE L1 BIDDER |
| 2 | L2₹24.7 L+₹1.7 L (7.23%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹24.7 L+₹1.7 L (7.23%) | L2 | Rejected-Finance SINCE NOT L1 |
| 3 | L3₹25.0 L+₹1.9 L (8.41%)Rejected-Finance | ₹25.0 L+₹1.9 L (8.41%) | L3 | Rejected-Finance SINCE NOT L1 |
| 4 | L4₹27.1 L+₹4.1 L (17.6%)Rejected-Finance | ₹27.1 L+₹4.1 L (17.6%) | L4 | Rejected-Finance SINCE NOT L1 |
| 5 | L5₹29.2 L+₹6.2 L (26.8%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹29.2 L+₹6.2 L (26.8%) | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Feb 2022, 6:00 pmClosed
CWE AMRITSAR
HQ CWE AMRITSAR
REPAIR/MAINT OF DISTRIBUTION TRANSFORMER VCBs AND CONNECTED ITEMS INCLUDING ATTENDING COMPLAINTS OF ELECTRIC SUPPLY AT OLD AMRITSAR CANTT
2022_MES_500852_1
CWE/ASR-64/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AMRITSAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE AMRITSAR
₹50,000
Yes
31 Mar 2022
11 Jan 2022
15 Feb 2022
11 Jan 2022
8 Feb 2022
27 Jan 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 meters wide and not exceeding 1.5 meter depth for laying of HT cables complete all as specified and as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers each not exceeding 25 cm in soft/loose soil complete all as specified
Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meters above the starting point, complete all as specified.
M&L for Sand cushioning to UG cable 40cm wide 15cm and 10cm thick above and below the cable in trenches/ducts complete all as specified and directed by Engineer-in-Charge punned down the thickness will be taken from measurement.
Supply and laying un-reinforced precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm all as specified factory made ISI marked.
Opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting / taking out the HT/LT side electric connections from both the primary & secondary side of the transformer of any type / description (indoor / outdoor type ) installed on floor/pole for carrying out necessary repair / rewinding to HT/LT side or any other repair as required after shifting the transformer to contractor's work shop including taking out complete core assembly, Magger the winding for identifying the fault/defective winding, segregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer of capacity 50 to 160 KVA including assembling & testing on completion & installation the same at the site all as specified and directed. Note : (i) Winding of coil and spares required as per repair shall be measured and paid separately under respective item.(ii) The transportation charges and taking down/taking up of transformer are inclusive in the quoted rates.(iii) The cost for the dehydration of transformer oil if reqd shall be measured & paid separately.(iv) The cost of insulation material such as paper, cotton tape , latheroid sheet , cast sheet etc are inclusive in the quoted rate
All as per Srl Item No 6.00 here-in-before but capacity 200 to 500 KVA complete all as specified and as directed.
Opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting/taking out the HT/LT side electric connections from both the primary & secondary side of the transformer of any type/ description ( indoor/outdoor type ) installed on four pole for carrying out necessary repair/replacement of HT/LT side bushes or any other repair as required for transformer of capacity 50 to 500 KVA including assembling & testing on completion complete all as specified and directed.
Dehydration and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil to 40 KV at 2.5 mm gap complete all as specified and directed .Note:- Dehydration machine and other necessary equipments required shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. Record of test results after dehydration shall be submitted to the Engineer-in-Charge
Supply and filling for topping up transformer oil in the transformer with dielectric strength of oil to min 40 KV at 2.5mm gap complete all as specified.
Material & labour for copper winding wire of any size/description suitable for step down power transformer of any capacity, including winding of coils (HT/LT) as per the manufacturers design & specification to obtain rated KVA complete all as specified.
Supply and fixing LT side brass stud with nuts. Bolts and washers for trasnformer of capacity 50 to 200 kVA complete all as specified and directed
Supply and fixing LT side brass stud with nuts. Bolts and washers for trasnformer of capacity 200 to 500 kVA complete all as specified and directed
Supply and fixing HT side brass stud with nuts. Bolts and washers for trasnformer of capacity 50 to 200 kVA complete all as specified and directed
Supply and fixing HT side brass stud with nuts. Bolts and washers for trasnformer of capacity 200 to 500 kVA complete all as specified and directed
Supply and filling silica gel in different capacity of transformers breathers complete all as specified and directed
Material & labour for Air breather assembly complete with fresh blue colour silcagel suitable for indoor/outdoor type transformer capacity 50 to 160 KVA complete all as specified.
All as per Srl Item No 17 here-in-before but capacity 200 to 500 KVA complete all as specified.
Suppy and fixing O/C and E/F relay suitable for 630 Amp 11000 Volts VCB as per sample including provision for fixing in existing panel by cutting/welding work all as specified and directed Make :Alstom/Schneider/ L&T (Model No. MC61ANX4000) and all other equivalent makes all as specified in Appendix'B' Note: The CT connection may be of /5A or /1A as required at site.
Shifting of transformer of capacity 50kVA to 500 kVA from one place to other place on two/four pole/plinth in old Amritsar cantt area/GG fort including removing and refixing of HT/LT connections complete all as specified and directed (All T&P, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to include )
Material and labour for fixing aluminium strip 40x10mm, including stainless steel bolts, washers, cutting and making hole as per the LT/HT stud of the transformer of rating 50-500kVA complete all as specified and directed by Engineer-in-charge
Suppy and fixing Closing coil suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make Kirloskar Model M-500 or all other equivalent makes all as specified in Appendix'B'
Suppy and fixing Tripping coil suitable for 630 Amp 11000 Volts VCB as per sample and specified and directed.Make Kirloskar Model M-500 or all other equivalent makes all as specified in Appendix'B'
Suppy and fixing Spring charging motor with gear assembly supply 230 volts AC suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make Kirloskar Model M-500 or all other equivalent makes all as specified in Appendix'B'
Suppy and fixing FRP Vaccum Bottle Support suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make :Kirloskar Model No.M-500 or all other equivalent makes all as specified in Appendix'B'
Suppy and fixing Space heater suitable for 630 Amp 11000 Volts VCB as per sample Make :Kirloskar/Crompton Greaves/Seimens or all other equivalent makes all as specified in Appendix'B'
Supply, fixing, connecting and testing in replacement of U/S meters flush type 96x96 mm digital type with LCD display including cutting/welding work all as directed at site of following type and range :-
(a) Volt meter 11 KV, suitable for 110/240 volt AC supply suitable for showing three phase values complete all as specified and as directed.
(b) Amp meter for 11 KV VCB 0-200 Amp with CT set suitable for 110/240 volt AC supply suitable for showing three phase values complete all as specified and as directed.
(c) Electronic Buzzer with input voltage of 230 V AC and output noise level of 90-120 db (decibels) suitable for Control and Relay panel and VCB panel as per existing sample complete all as specified and directed .
Supply and fixed LED indicator lamp 12/24 DC or 230 AC as required as per sample complete all as specified and as directed.
Supply , fixing testing and commissioning in replacement of existing electromechanical type transformer differential protection relay with differential overcurrent , earth fault protection complete all as specified and directed. The setting of the differential relay shall be carried out by the representative of OEM in accordance with the setting of old electromechanical differntial relay Make Schneider model No PT3T32 or equivalent in L&T /Siemens or all other equivalent makes all as specified in Appendix'B'
Supply and fixing glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge
Material and labour for recording earth resistance values of distribution transformer/GOD/LA 11kV/66kV any type strip/wire of any capacity and submitted the record to the Engineer-in-charge complete all as specified and directed. Note: The T&P for the work to be arranged by the contractor and all rates are deemed to be inclusive in quoted rate.
Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 25 X 4 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supplying, laying, jointing & testing 2.5 Sqmm 4 core PVC insulated, armoured electric cable with flexible stranded copper conductor, 1100 volts grade complete including taking down old unserviceable cable any type and size all as specified and directed.
All as per Srl Item No 34.00 here-in-before but 2.5 Sqmm 10 core complete all as specified and as directed.
Material & labour for preparing old painted surface of distribution / power transformer outdoor / indoor / pole mounted of capacity 300 to 500 KVA by cleaning, removing the old paint by scratching with wire brush etc and applying with spray machine two coats of synthetic enamel paint of grey colour on external surfaces of the transformer and writing of letter HT / LT or HV / LV and SM / MES Nos including disconnecting and making electric connections complete all as specified and directed. Note: (i) The compressure / spray machine and other required necessary equipments shall be arranged by the contractor and quoted rates shall be inclusive of this aspect.
All as per Srl Item No 39.00 here-in-before but capacity 50 to 250 KVA complete all as specified and as directed.
Material and labour for filling fine river sand in the trench below power transformer and trencehes of HT VCB including levelling and spreading complete all as specified and directed by engineer in charge
Supply and fixing in replacement of pin type insulator polymer material with capacity of 11kV and GI pin, including GI nuts,bolts and washers, binding conductor and insulator with GI wire and dismantling old insulator complete all as specified and directed.
Supply, installation, connecting, and testing of 11 KV single phase indoor resin cast CT of ratio 300/150/5-5A suitable for VCB as per existing type and make including taking down old unserviceable CT all as specified and directed.Make : Instrans/CG/Schneider or all other equivalent makes all as specified in Appendix'B'
All as per Srl Item No 40.00 here-in-before but CT ratio 100/50/5-5A complete all as specified and as directed.
Supply, laying, jointing and testing HT XLPE cable cross section area 300 Sqmm, 3 core, 11000 V screened earthed, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc incl taking out old unsv cable any type complete all as specified and directed.Make Havells/Gloster/ KEI or all other equivalent makes all as specified in Appendix'B'
Supply, laying, jointing and testing HT XLPE cable cross section area 95 Sqmm, 3 core, 11000 V screened earthed, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc incl taking out old unsv cable any type complete all as specified and directed.Make Havells/Gloster/ KEI or all other equivalent makes all as specified in Appendix'B'
Material and labour for testing of outdoor type three phase SF6 Circuit breaker for carrying out Contact Resistance Measurement, Circuit breaker Trip time, insulation resistance and coil resistance test complete at site and submission of report. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. The quoted rates are deemed to be inclusive of included general servicing, greasing of mechanical gears, gas recharging of the breaker etd at site complete all as specified and directed by Engineer-in-Charge. Note(i) The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. (ii) The replacement of major parts shall be measured and paid separately under relevant item of the schedule. (iii) The testing shall be carried by a testing agency having similar experience of carrying out test in PSU/govt substation of 66kV or above. Necessary certificate shall be submitted by the contractor for approval of the firm to the Engineer-in-Charge.
Material and labour Control and Relay panel (C&R panel) of transformer testing for carrying out tests on differential relay , IDMT relay and other auxiliary relay of transformer protection with secondary injection test kit complete at site and submission of report. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. The quoted rates included general servicing, checking of wiring, replacement of minor parts complete all as specified and directed by Engineer-in-Charge. Note :(i) The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. (ii) The replacement of major parts shall be measured and paid separately under relevant item of the schedule. (iii) The testing shall be carried by a testing agency having similar experience of carrying out test in PSU/govt substation of 66kV or above. Necessary certificate shall be submitted by the contractor for approval of the firm to the Engineer-in-Charge.
Material and labour for testing of 66kV outdoor type CT and carrying out tests i.e IR test, polarity test, knee voltage test, ratio test with primary injection kit. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. The quoted rates included general servicing, checking of wiring, replacement of minor parts complete all as specified and directed by Engineer-in-Charge .Note(i) The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. (ii) The replacement of major parts shall be measured and paid separately under relevant item of the schedule. (iii) The testing shall be carried by a testing agency having similar experience of carrying out test in PSU/govt substation of 66kV or above. Necessary certificate shall be submitted by the contractor for approval of the firm to the Engineer-in-Charge.
Material and labour for testing of 11kV indoor type three phase CT any rating and carrying out tests i.e IR test, polarity test, knee voltage test, ratio test with primary injection kit. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. The quoted rates included general servicing, checking of wiring, replacement of minor parts complete all as specified and directed by Engineer-in-Charge.Note (i) The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. (ii) The replacement of major parts shall be measured and paid separately under relevant item of the schedule. (iii) The testing shall be carried by a testing agency having similar experience of carrying out test in PSU/govt substation of 66kV or above. Necessary certificate shall be submitted by the contractor for approval of the firm to the Engineer-in-Charge.
Material and labour for testing of indoor type Vaccum Circuit breaker for carrying out Contact Resistance Measurement, Circuit breaker Trip time, insulation resistance and coil resistance test complete including checking of wiring defect and recitifcation if any at site and submission of report. The quoted rates included general servicing, greasing of mechanical gears of the breaker etc at site complete all as specified and directed by Engineer-in-Charge.Note :(i) The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. (ii) The replacement of major parts shall be measured and paid separately under relevant item of the schedule. (iii) The testing shall be carried by a testing agency having similar experience of carrying out test in PSU/govt substation of 66kV or above. Necessary certificate shall be submitted by the contractor for approval of the firm to the Engineer-in-Charge.
M&L outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 50 to 95 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L outdoor type cable end termination kit, heat shirnkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 120 to 185 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 240 to 300 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 to 95 Sqmm 3 core heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 120 to 185 Sqmm 3 core , heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
Fixing only outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable all sizes including testing after jointing complete all as specified and directed by engineer-in-charge
Fixing only cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable any size heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
Supply and fixing in replacement of HT jumper of existing two/four pole structure of transformer etc using 95 Sqmm single core aluminium cable conductor , including PG clamp nut, bolts, thimbles and washers etc as required at site all as directed by Engr-in-Charge.
Supply and fixing in replacement of HT fuse wire for existing two/four pole structure of transformer etc using suitable size fuse wire complete all as specified by engineer in charge
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator polymer type type switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 400 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as per site requirement and as specified by Engr Incharge , complete with DO fuses assembly with channel and one No. operating Rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set all as directed by Engineer-in-charge. Makes: as specified in Appendix'B'
Attending complaints by deplyoing required tools, Machinery and additional manpower resources based on the nature of complaints pertaining to HT/LT netwrok/transformers/ LT panels, VCB and connected E/M items of Electrical supply as required for attending complaints & maintaining the electric supply at Amritsar Cantt round the clock (24 hours) having following networks as specified & directed by Engr-in-Charge :- (i) Feeder No 1 emanating from 66kV Grid Substation to Take over point - Appx length 500 RM (ii) Feeder No 2 emanating from 66kV Grid Substation to Thimayya Power house - Appx length 1500 RM (iii) Feeder No 3 emanating from 66kV Grid Substation to Thimayya power house - Appx length 1600 RM (iv) Feeder No 4 emanating from 66kV Grid Substation to Sata battery power house - Appx length 370 RM (v) Feeder No 5 emanating from 66kV Grid Substation to Thimayya Power House - Appx Length 1500 RM (vi) Feeder No 6 emanating from Take over point substatation to Gulat Road Map Substation - Appx Length 900 RM alongwith 4Nos distribution transformer of different sizes, GODs, four pole structures and LT panels and LT cable and OH LT lines of approx 2km (vii) Feeder No 7 emanating from Take over point substation to div HQ four pole structure - Appx length 2700 RM alongwith 10 transformers of different sizes, GODs, four pole structures and LT panels and LT cable and OH LT lines of approx 5km. (viii) Feeder No 8 emanating from Thimaaya power house to panther auditorium and double tank pump (D-feeder) - Appx length 2100 RM alongwith 9 Nos distribution transformer of difference sizes, GODs, Four pole structures and LT panels and LT cable and OH LT lines of approx 3km (ix) Feeder No 9 emanating from Thimayya power house to Ajnala road quarters (Stn House feeder) - Appx length 900RM alongwith 4 Nos distribution transformer of different sizes, GODs , four pole structures and LT panels and LT cable and OH LT lines of approx 1.5 km (x) Feeder No 10 emanating from Thimayya power house to infantary area md accn (Local Feeder) - Appx length 700RM alongwith 4 Nos distribution transformer of different sizes, GODs , four pole structures and LT panels and LT cable and OH LT lines of approx 1.3 km (xi) Feeder No 11 emanating from Thimayya power house to IB (C Feeder) - Appx length 1200RM alongwith 4 Nos distribution transformer of different sizes, GODs , four pole structures and LT panels and LT cable and OH LT lines of approx 1.3 km (xii) Feeder No 12 emanating from Thimayya power house to Manekshaw Enclave (Manekshaw Feeder) -Appx length 1600 RM alongwith distribution transformers 4 Nos of different sizes ,GODs, four pole structures and LT panels and LT cable and OH LT lines of approx 1.5 km
(xiii) Feeder No 13 emanating from Gulat Road substation to Dumping ground MAP accn - appx length 1200 RM along 5 Nos distribution transformers of different sizes, GODs, four pole/two pole structures and LT panels and LT cable and LT OH lines of approx 1.2 km (xiv) Feeder No 14 emanating from Gulat Road substation to MAP phase 1 quarter - appx length 500 RM along 4 Nos distribution transformers of different sizes, GODs, four pole/two pole structures and LT panels and LT cable and LT OH lines of approx 1.0 km (xv) Feeder No 15 emanating from Sata battery substation to MAP phase 2 md Accn - appx length 400 RM along 4 Nos distribution transformers of different sizes, GODs, four pole/two pole structures and LT panels and LT cable and LT OH lines of approx 1.0 km (xvi) Feeder No 16 emanating from Sata battery substation to Gulat road substation - appx length 1000 RM alongwith connected GODs, four pole/two pole structures. (A) Nature of work to be done (i) Maintaining the servicability and attending breakdown complaints of electric supply of all the HT feeder of Old Amritsar mentioned from S.No (i) to (xvi) above. (ii) Attending the complaints of breakdown of all LT feeders/cables/OH line from the main poles upto the main DB of the occupant of the user. (iii) Periodical maintainence/complaint rectification of all the HT/LT feeders mentioned from S.No (i) to (xvi) above including (a) Replacement of overheated jumpers/blown off jumpers. (b) Replacement of blown off HT fuses (c) Periodical/Routine complaints of LT panels (d) Suitable wooden ladder shall be provided by the contractor to do the complaints by the tradesman. (e) Vehicle shall not be provided by the department, it shall be deployed by the contractor. (f) Contractor shall deploy sufficient manpower round the clock in the power house for rectification of the complaints within 2 hours of the lodging of complaint failing which penalty shall be made at Rs 200/per complaint (g) Complaint register and complaint slip shall be provided and maintained by the Contractor Note: (i) Time Consuming jobs such as replacement of defective cable joints / repair of cable by extension of loop/ periodical trimming of trees/branches along the over head lines shall be measured and paid separately. (ii) Minor items such as HT/LT PVC tape shall be arranged by the contractor at no extra cost to the govt. (iii) Protective clothing/Uniform/Tools : The duty electrician and helpers shall wear uniform as directed/decided by the GE/engineeer-in-charge. Mandatory tools such as insulating plier, cutter, screw drivers, DE spanner set, Night Torch, safety helmet, safety belt shall be provided by the contractor. (iv) Rates quoted by the contractor are deemed to be inclusive of above.
Raman Electric Trading Co
Rishi Construction Co
Bharat Builder
R D Bansal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .