Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.9 CrAccepted-AOC UNIT NO 424 EROS CITY SQUARE ROSEWOOD CITY GURUGRAM HARYANA | ₹3.9 Cr | L-1 | Accepted-AOC Lowest First |
| 2 | L-2₹4.6 Cr+₹71.6 L (18.4%)Rejected-AOC DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | ₹4.6 Cr+₹71.6 L (18.4%) | L-2 | Rejected-AOC Lowest Second |
| 3 | L-3₹5.0 Cr+₹1.1 Cr (29.3%)Rejected-AOC 101 1 10 68 4 PLOT NO 52 SRINIVASA NILAYAM CHIKOTI GARDENS BEGUMPET HYDERABAD TELANGANA 500016 | MEDCHAL MALKAJGIRI | TELANGANA | 500016 | ₹5.0 Cr+₹1.1 Cr (29.3%) | L-3 | Rejected-AOC Lowest Thrid |
| 4 | L-4₹5.1 Cr+₹1.2 Cr (31.0%)Rejected-AOC J 219 LANE W 15 WESTERN AVENUE SAINIK FARMS NEW DELHI | ₹5.1 Cr+₹1.2 Cr (31.0%) | L-4 | Rejected-AOC Lowest Four |
| 5 | Rejected-Technical 2277 RAJA PARK RANI BAGH RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | - | - | Rejected-Technical Not Quqlified |
Tender Value
₹4 Cr
EMD Value
₹8 L
Closing Date
9 Oct 2020, 12:00 pmClosed
Secretary, RSSC
SMS Stadium, Jaipur
Renovation of Synthetic Hockey Astroturf at SMS Stadium, Jaipur
2020_RSSPC_197147_1
NIT-24/RSSC/JAIPUR/HOCKEY
Open Tender
Civil Works
Percentage
180 days
Jaipur
Please Refer Tender Documents
4 documents required · 4 mandatory
₹5,000
Secretary, RSSC and MD, RISL, Jaipur
₹8 L
Yes
SMS Stadium, Jaipur
4 Dec 2020
27 Aug 2020
9 Oct 2020
27 Aug 2020
9 Oct 2020
27 Aug 2020
7 Sept 2020
Amount
BoQ2 (Non BSR Item)-2
Removal of existing hockey pitch with sock-pad properly.
Repairing work of existing drain - Repairing of drain line include erosion, repair, clearing, cleaning, reshaping, regrading, deepening of side drains as well as catch water drains, complete in all the aspacts.
Existing Sprinkle System: Removing water guns from main hockey ground including all fittings, related accessories and handover all fittings/acessories to RSSC.
Supply and installation of fully computerized, automatic and single key operation pop-up sprinkler system specifically designed VP2 (range 30- 50 meter) “Perrot” or equillent for synthetic Hockey Surface including all fittings, accessories, excavation, laying ppes, complete in all the aspacts . HDPE pipe dia 150/110 MM class pe100 grade 12.5kg/cm2.
Supplying and installation of 50 H.P. coupled pumping set with Electronic controller make like Grundfos/KSB/ Calama etc. or equivalent, making connections suitable for T.W/ D.C.B./ open well. The job includes screwing and welding of flanges on GI B-class riser pipes, installation of complete fittings and accessories with riser pipes, jointing of electrical cable and other connections. Must be compatible with sprinkler system in all the aspacts. Layout of the same along with details of product is to be got approved by Engineer-in-Charge.
Existing Sump repairing - Repairing of sump include erosion, repair, clearing, cleaning, reshaping, regrading, water proofing , plastering, complete in all the aspacts.
Supplying and fixing of aluminum Goal Post as per drawing and design including all fitting and net. As per FIH specifications.
Supply and Installation of FIH approved global category surface along with in-situ shock pad. Installation to be done as per manufacturer's guidelines for the particular surface and FIH norms. All markings to be done as per FIH competition marking rules and standards etc. complete as per instruction of Engineer-In-Charge. Agency to arrange for FIH Global certificate for the field after installation at its own cost. As per Technical specifications mentioned in Tender Documents.
Supply & installation of multi -rib roofing sheets manfacuture out of 0.50 mm TCT (total coated thickness) high lensito Zinc aluminium alloy coated galvalume steel (AZ 150 gms zine and aluminum coated 550 mpa yelid strength ) confring to as 1397/ASTM A792 sheets to have wiede pames and 30mm thick high at 250 mm centers and a cover width of 1020 mm sheets shall be coated with a silcon modified polyster print system on acontinuous oil coating line on the extractor faces and width and with polyester backing coat at the back sides . the minimum dry film thickness shall be 20 microsn over 5 microns epoxy primer for polyester coating respectlively sheets shall have proporionality anti siphonle fute at male and to prevent leakage sheets shall be fixed by means of seil dirrlling self tapping hot dip zinc coated hex head fatener of size 12 x 14 x 55 mm long . The sheet shall be supplied in custom length and for a minimum upto 12 mtr.
GALLANT SPORTS AND INFRA PVT LTD
GREAT SPORTSTECH LIMITED
Syncotts International
GREAT SPORTSTECH LIMITED
Syncotts International
shiv naresh sports pvt. ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .