| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.8 L+₹2.0 L (5.53%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹41.8 L+₹5.0 L (13.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹41.9 L+₹5.1 L (13.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹47.5 L+₹10.7 L (29.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Dec 2019, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
SPECIAL REPAIRS TO CERTAIN BUILDINGS (BLDG Nos. P-1, P-2, P-3, P-9, P-10, P-12, P-13 AND P-14) AT ANURAG AND REPAIRS OF RCC ROOF AND OTHER CERTAIN B/R WORKS OUTSIDE DRDL UNDER AGE BR I , HYDERABAD
2019_MES_303038_1
GE I KBAGH TOKEN 71 OF 2019 2020
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹90,000
Yes
16 Jan 2020
2 Dec 2019
3 Jan 2020
2 Dec 2019
30 Dec 2019
16 Dec 2019
3 Dec 2019 - 10 Dec 2019
Amount
M & L for water proofing treatment on roof slab including cleaning the roof surface with wire brush and using water and applying cement slurry @ 3 kg per Sqm and cement plaster 10mm thick in CM 1:4 mixed with WPC @ 2% by weight of cement as per manufacturer's instructions and applying oil based bitumen primer coat at the rate of 0.30 liters per sqm by forced application method on top of plastered roof surface and applying evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.2 kg per sqm and applying APP based modified polymeric membrane of minimum weight not less than 3kg/sqm as approved by GE, over the bituminous coated surface with100 mm overlaps and the over lap shall be sealed by flame as per manufacturer's instruction and applying evenly a coat of hot air blown bitumen of grade 85/25 at the rate of 1.2 kg per sqm including complete removal of existing treatment and removal of the same to a distance exc 50m and n.exc 250m complete all as directed. Note: 1)Waterproofing compound will be measured and paid separately under relevant item.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in padding concrete, coving in vertical junctions, coping and plat form for OH water tanks etc on roof top, including demolition of old concrete complete all as directed.
Supply only integral water proofing compound
M&L for preparation of surface and Applying two coats of aluminium paint @ 100 ml/sqm for each coat over APP membrane complete all as directed.
Supply and laying of Geo textile fibre over & above APP membrane as per manufacturers instruction complete all as directed. Make : Garware Ropes Ltd/TIKIDAN or equivalent
M&L for 250 x 250 x 19/20 mm thick hydraulically pressed cement tile laid over 15mm thick screed bed in cement mortar 1:4 mixed with water proofing compound and jointed with cement mortar 1:3 mixed with 5% crude oil by weight of cement over APP membrane complete all as directed.
S & F in repairs PVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to wall or laid in floors complete all as directed.
S & F in repairs PVC (SWR) bends (any radius) suitable for 110mm bore pipe complete all as directed.
S&F in repairs GI water tubing of 15mm dia medium grade, with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete all as directed.
S&F in repairs GI water tubing of 20mm dia, medium grade, with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete all as directed.
S&F Rotational moulded polyethylene water storage tank of 1000 ltrs capacity (cylindrical vertical with closed top) double layered hoisted and fixed in position including dismantling existing PVC water tank complete all as directed
S&F Rotational moulded polyethylene water storage tank 2000 ltrs capacity (cylindrical vertical with closed top) double layered hoisted and fixed in position including dismantling existing PVC water tank complete all as directed.
S&F in repairs ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed of 20mm bore (min weight 210gms) complete all as directed.
S&F in repairs mild steel works as in stairs/ladders (framed) including stringers, treads, landing balusters, hand rails etc including cleats brackets etc complete, confirming to Fe-410-w (gde-250) quality B all as directed
M&L preparation of new or previously untreated steel surface of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as directed.
S&F in repairs polycarbonate sheet 10 mm thick fixed with aluminium profile top at joint, aluminium section 50 mm wide with 2 mm thick including fixed with self tapping screw and full welding of 10 mm thick, scaffolding and wastege material for fixing in doom complete all as directed. Note: Safety precautions to be taken deemed to be included in quoted rate. Make:- Lexan, Techno commercial equivalent as approved by GE
M&L for Non skid coloured ceramic tiles 7mm thick, area of each tiles exc 0.06 sqm but n.exc 0.11 sqm as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match laid on and including 15 mm thick screed bed in cement mortar (1:4) , over 25 mm thick PCC 1:2:4 type B0 (12.5mm graded aggregate) finished even and fair to receive tiles including dismantling of existing tiles alongwith cement mortar bedding and concrete, complete all as directed.
M & L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick backing coat in in cement mortar (1:4) including dismantling of existing tiles alongwith backing coat complete all as directed.
M & L for coloured glazed ceramic tiles of size 350x250x7mm /450 x 300 x 7 mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10mm thick backing coat in cement mortar (1:4) including dismantling of existing tiles alongwith backing coat complete all as directed.
M & L for 10mm thick, light shade vitrified ceramic tiles, area of each tile n exc. 0.36 sqm as in floors, set and jointed in neat cement slurry and pointed in cloured cement to match, laid on and including 15 mm thick screed bed in cement mortar (1:4), complete including dismantling of existing tiles alongwith cement mortar bedding complete all as directed.
All as per srl item No.20 here-in-before, but as in skirting/dado laid on and including 10mm thick backing coat in cement mortar (1:4) including dismantling of existing tiles alongwith backing coat, complete all as specified and as directed..
M&L for 25 mm thick Paving tiles using white cement and pigments of size 300mm x 300mm with wear resistant coating of approved design laid with cement slurry @ 3Kg/ Sqm over 15mm thick screed bed in cement mortar 1:6 including taking out old unserviceable tiles alongwith screed bed complete all as directed.
S&F in repairs vitreous china squatting pan 'orrisa' pattern of size 580x440mm white with integral footrest (Excluding flushing cistern & flush pipe) but including lime concrete bedding, P or S trap and making good all the disturbed surfaces to match with the adjoint complete all as directed.
S&F in repairs vitreous china white wash down water closet pan, pedestal pattern including fixing bolt, plastic water closet seat and cover with recessed bottom with MS CP hinging device (excluding flushing cistern and flush pipe), complete all as directed .
S&F in repairs Vitreous china Urinal half stall type, white (excluding flushing cistern and waste pipe), complete all as directed.
S&F in repairs PVC valveless, syphonic action type flushing cistern of 10 litres capacity low level, white , with inlet, ball valve, bend float and handle including brackets, complete all as directed.
S&F in repairs angle valve of 15mm bore, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed.
S&F in repairs stop valve of 15mm bore cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as directed.
S&F in repairs bib cock of 15mm bore cast copper alloy chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as directed.
S&F in repairs Pillar taps of 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm complete all as directed.
S&F in repairs waste couping suitable for 32mm bore pipe of CP (half or full threaded) complete all as directed.
S&F in repairs cast copper alloy grating doom 100mm dia CP complete all as directed.
S&F in repairs cast copper alloy, urinial spreader of CP, any colour suitable for 15mm dia pipe complete all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area n exceeding 1.50 square metre, complete all as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as directed. Make : SINTEX / RAJSHRI PLASTIWOOD/ NANDI/ UNIVERSAL
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, complete all as directed .
S&F 125mm long aluminium anodised barrel tower bolts of extruded section complete all as directed.
S/F mild steel butt hinges medium weight cold rolled of 100mm size, complete all as directed.
S&F Aluminium handle of 150mm size, cast type, anodised, complete all as directed.
Complete removal of existing treatment on walls, ceiling surfaces including cornices, pillasters etc. by scrapping down with wire brushes and removing existing loose particles and preparing the surfaces and giving texture finish of roughtex and applying two coats of weather proof exterior emulsion over a coat of primer of approved colour and design complete all as directed.
S&F S/S grade 304 railing 50 mm dia hand rail and 3 Nos 16 mm dia horizontal rails and 40 mm dia verticles at 900 mm centre to centre complete including grinding and buffing at joints including taking down old existing railing complete all as directed.
Taking down carefully the split AC ( internal and external unit) of any make and capacity by pumping down the refrigerant to external unit including stabilizer from the location and shifting the same to the MES store and re-installing the split AC inner, outer, units ,copper tubes and stabilizer at the new location or existing location as directed by the site-in-charge including top up the refrigerant as required at site later on renovation of building complete all as directed. Note : 1-(Job includes necessary core cutting on any type of wall for drawing the suction & discharge lines) 2-The distrubed copper tubing and spares required will be measured and paid saparately.
Renewal of copper tube of size 5/8 or 3/8 inch dia of split type AC 1.5/2.0 Ton complete all as directed.
Renewal of copper tube of size 1/2 or 1/4 inch dia of split type AC 1.5/2.0 Ton complete all as directed.
Renewal of insulation felt for split type AC 1.5/2. ton copper tube inlet/oulet to out door unit complete all as directed.
Supply & charge refrigerant gas R-22 upto required level complete all as directed Make:- MAFRON/ FREON
Supply and charging of refrigerent gas R-410A complete all as directed
M/S VASU ENGINEERS
M/S SARASWATHI CONSTRUCTIONS
EXELLENT POWER CORPORATION
Maruthi international
saradhi construction combines
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .