Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Lowest one | |
| 2 | L2₹28.5 L+₹1.6 L (5.85%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance Other than lowest one | |
| 3 | L3₹31.1 L+₹4.2 L (15.5%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L3 | Rejected-Finance Other than lowest one | |
| 4 | L4₹36.8 L+₹9.8 L (36.5%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance Other than lowest one |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW NOFRA
Dr Homi Bhabha Road, Navy Nagar Colaba, Mumbai-05
REPAIR MAINT OF MES E/M INSTALLATIONS AND LIFT ROOMS UNDER AGE BR II AT NOFRA UNDER GE NW NOFRA COLABA MUMBAI.
2021_MES_466586_1
8955
Open Tender
Civil Works
Item Rate
240 days
Mumbiai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹70,000
Yes
21 Jan 2022
9 Aug 2021
6 Sept 2021
9 Aug 2021
1 Sept 2021
20 Aug 2021
9 Aug 2021 - 19 Aug 2021
60 days
Amount
Note : The tenderer shall note before quoting his unit rate that certain items of the work shall be executed in high rise building & necessary scaffolding & safety measurement / precautions shall be provided by the tenderer.
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame) , complete all as specified and directed by Engineer in charge.
Taking down chowkats or frames exc 1.5 sqm each but n.exc 4 sqm with shutters (without taking off shutters from the frame) , complete all as specified and directed by Engineer in charge.
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each, complete all as specified and directed by Engineer in charge.
M&L 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engineer in charge.
S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified and directed by Engineer in charge.
M&L for preparation of newly wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces complete all as specified and directed by Engineer in charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specification and drawings, complete all as specified and directed by Engineer in charge.
S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed by Engineer in charge.
S&F powder coated (colour of coating as directed) aluminium (minimum 25 micron thickness of coating) of various section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc. rubber beading, clips locking arrangement, handle, sealant etc complete all as specified and directed by Engineer in charge.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed by Engineer in charge.
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick complete all as specified and directed by Engineer in charge.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed by Engineer in charge.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section complete all as specified and directed by Engineer in charge.
S&F 150 mm size aluminium alloy handles, cast type anodised, ISI marked complete all as specified and directed by Engineer in charge.
S&F butt hinges 100 mm stainless steel hinges medium weight and fixed complete all as specified and directed by Engineer in charge.
S&F 150 mm long floor door stopper of aluminium door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer in charge.
Hacking out old broken glass (any thickness, size, quality or description) from iron frames glazed with putty or wooden beads complete all as specified and directed by Engineer in charge. (NOTE : Work carried out upto 7th floor of building either from inside or from outside)
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer in charge. (NOTE : Work carried out upto 15th floor of building either from inside or from outside)
S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed by Engineer in charge.
S&F as in repairs aluminium anodized barrel tower bolts 200 mm of extruded section and fixed complete all as specified and directed by Engineer in charge.
S&F as in repairs 150 mm size aluminium alloy handles, cast type anodised, ISI marked complete all as specified and directed by Engineer in charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, upto 15th floor of bldg.,complete all as specified and directed by Engineer in charge.
Rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces in patches, surfaces to be finished even and smooth without using extra cement, upto 15th floor of bldg.,complete all as specified and directed by Engineer in charge.
M&L for plastering 10mm thick in CM 1:3 in ceiling finishing even and smooth without using extra cement, upto 15th floor of bldg.,complete all as specified and directed by Engineer in charge.
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions & upto 15th floor of bldg.,complete all as specified and directed by Engineer in charge.
Supply only integral water proofing compound as per IS 2654, complete complete all as specified and directed by Engineer in charge.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of 1 to 2 mm thick wall care putty and a coat of primer upto 15th floor of bldg.,complete all as specified and directed by Engineer in charge.
Preparation of new plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed by Engineer in charge. NOTE : Work carried out upto 16th floor of building.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling upto 15th floor of bldg., complete all as specified and directed by Engineer in charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer in charge.
M&L for cement concrete type B-1 , 1:2:4 (20 mm graded stone agg) as in floor and fisnishing cement concrete surface even, complete all as specified and directed by Engineer in charge.
Material & labour for preparation of surfaces cracks of plaster internal/external of walls, ceilings/ chajjas upto 5mm wide, remove, loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing of old/new surfaces of walls/ceiling washing the surface thoroughly, filling the cracks, creaves with crack filling compound as suggested by the manufacturers and applying two coats of Rain coat manufactured by Dr Fixit of Pidilte Industries Ltd. (shade to match the existing paint) including necessary scaffolding for work all as specified and directed by Engineer in Charge.
Material & labour for providing in repairs water proofing treatment with 4mm APP (Atactic polypropylene) modified polyester(bituminous) membrane reinforced of 3.5Kg/Sqm with non woven polyester mat of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer @ 0.25 Kg/Sqm over roof (An overlap of 100mm and 150mm shall be provided on sides and ends respectively) and applying two coats of bituminous aluminium paint on APP sheet including removal of old damaged APP sheets including 10mm thick cement plaster on roof in CM (1:3) & finishing even and smooth without using extra cement to receive APP membrane including cleaning of exposed surface of slab by wire brush, remove dust and removing from MoD land complete all as specified and directed by Engineer in charge.
Preparation of old plastered surfaces of walls and apply two coat distemper oil emulsion over a coat 2 mm thick wall care putty over 0ne coat of primer complete all as specified and directed by Engineer in charge.
M&L for preparation of old wall surfaces and applying two coats of oil emulsion distemper complete all as specified and directed by Engineer in charge.
M&L for preparation of old plastered surfaces of ceiling and applying one coat of oil emulsion distemper on ceiling complete all as specified and directed by Engineer in charge.
M&L for preparation of old plastered surfaces on ceiling and applying two coats of white wash complete all as specified and directed by Engineer in charge.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint & ht. upto 15th floor of bldg., complete all as specified and directed by Engineer in charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint & ht. upto 15th floor of bldg., complete all as specified and directed by Engineer in charge.
Preparation of old plastered surfaces of wall and apply one coats of Acrylic emulsion exterior paint of required shade : (one coat applied @ 1.67 ltr/10 sqm), complete all as specified and directed by Engineer in charge. (For bldg upto GF to max of 15th Floor + upto height of mummty top ). Note : Necessary safety precautions need to taken before applying paint.
Preparation of old plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade : (two or more coats applied @ 1.67 ltr/10 sqm), complete all as specified and directed by Engineer in charge. (For bldg upto GF to max of 15th Floor + upto height of mummty top ). Note :-Necessary safety precautions need to taken before applying paint.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land complete all as specified and directed by Engineer in charge.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed by Engineer in charge.
M&L for coloured glazed ceramic tiles 450x300x7 / 350x250 x7 mm mm thick but as on vertical surfaces such as skirting/dado including 15 to 20mm thick backing coat in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer in charge.
Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified and directed by Engineer in charge.
M&L 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table, floors and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding and rounding complete all as specified and directed by Engineer in charge.
M&L for machine cut cudappa stone slab 20-25 mm thick laid over screed base in cement and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer in charge.
M&L, for mirror polished machine cut kota stone slab flooring 20-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed by Engineer in charge.
M&L, for machine cut kota stone slab flooring 20-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed by Engineer in charge.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed by Engineer in charge.
S&F PVC wall panelling consisting of 5mm thick wood grain printed PVC sheet and fixed over GI running channels 50mm wide and 0.6mm thickness at every 1m interval , fixing over brickwall /concrete walls with screws and all corners, top and bottom portion of PVC lining covered with L/T shaped PVC sheet of same colour/texture including all necessary cuttings near switch boards and other fixtures if fitted over wall, complete all as specified and directed by Engineer in charge.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer in charge.
Material and labour for brick work with sub class "B" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed by Engineer in charge.
M&L old size Brick Work with sub class 'B' bricks, straight or curved on plan to any radias in half brick thick walls, built in cement moter 1:4 complete all as specified and directed by Engineer in charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in benching, bed plates, coping and the like including from work and finsihing all exposed surface of concrete complete all as specified and directed by Engineer in charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer in charge.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing; frame work for water tanks and similar work conforming to Fe 290 Gd E-165 complete all as specified and directed by Engineer in charge.
S&F as in repairs Mild steel, plain, black sheet 1.00mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc, complete all as specified and directed by Engineer in charge.
S&F rolled sections as in main & cross beams , columns, hip and jack rafters , purlins where connected to common rafters and running rails & any other places with angles cleats ot other connected plates confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified and directed by Engineer in charge.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attahment, confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified and directed by Engineer in charge.
S&F as in repairs factory made RCC cover slab of size 300mm x 600mm size and 100mm thick , including placing over at directed locations, complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling ad mass concrete, complete all as specified and directed by Engineer in charge.
M&L for cement concrete interlocking paver blocks 60 mm thick having glossy finish (colour and pattern approved by GE) (tested as per IS 1237-1980) laid over and including 50 mm thick dry sand cushioning and voids filled with dry and surface compact, including compaction by means of surface vibrator & removing of old broken tiles, complete all as manufacturer's instructions &l as specified and directed by Engineer in charge.
Dismantling of ceiling boards any thickness etc including aluminium grid frame work complete all as specified and directed by Engineer in charge.
M&L for false ceiling made out of 600x600x 4 to 6 mm thick ceiliing board / tiles deep panel suspensor system made out of powder coated GI strips/sections main tee of size 23.50x40x0.63mm and cross tee of size 23.50x23.50x0.63mm and angle size 19x19x0.63mm including 3mm GI wire for suspending bolts necessary washers nut/clits/pin hook etc. for securing frame work to ceiling to the snap grid all as directed by Engr-in-charge including provn of necessary holes / cuttings for providing light/fan as required including making necessary recesses / projected pattern complete all as specified and directed by Engineer in charge. Make -Armstrong/Gypsum Board/Anchor Bombay/Everest.
S&F GI tubing medium grade with all fittings like Tee, bend, elbow etc, 15 mm bore fixed to walls or ceilings with saddles/spacers , clips,including taking down existing GI water tubing complete with all fittings of 15 mm bore, complete all as specified and directed by Engineer in charge.
S&F 500 lit capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed position all specified in SSR Part-I, with and including 20mm dia. Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, screwed for iron pipes and fixed; including disconnecting and dismantling/ taking down of existing old unserviceable water storage tank from terrace, complete all as specified and directed by Engineer-in-Charge.
S&F as in repairs Steel rolling shutters 1mm thickness of laths, with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indi?cated, complete: push pull or manual type , complete all as specified and directed by Engineer in charge.
Chipping , removing carefullly concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debris out side the premises etc. upto 15th floor of building, complete all as specified and directed by Engineer in charge. NOTE : Hard concrete should not be removed by force.
Material & labour for cleaning existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. as approved by GE on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry upto 15th floor of building, all as per manufacturer's instructions & as specified and directed by Engineer in charge.
Material & labour for carry out application of Bi-polar migratory corrosion inhibitor EPCO-KP-100/ Protectsil CIT/Ferogard 903 on concrete surface (this inhibitor shall have migratory kind of properly which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibitor the corrosion and de-passivating the Electro-chemical reaction. It should have properly to attack as well as cathode, which is purely alkaline in nature (pH-9.5), So it has no carcinogen activity with concrete all as per manufacturer's instructions upto 15th floor of building complete all as specified and directed by Engineer in charge.
Material & labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes complete all as specified and directed by Engineer in charge. Works shall be carried out upto 15th floor of building as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty. Make : Dr Fixit, STP, Choksy Chemical as approved by GE.
Material & labour for Injecting low viscosity MONOPOL (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of material mixing of material components (part a & b) in the required quantities as per manufacturer`s instruction by weigh batching, Grouting maintain the pressure at exit (0.5 to 1.0 kg/cm2) by monitoring pressure gauge at exit grout the material through prefixed nozzles in the structural elements@100ml per nozzle Repeat the process for all the nozzles. (Beam, RCC wall and columns) complete all as specified and directed by Engineer in charge. Make :- Krishna Conchem / Dr Fixit / Fosroc as approved by GE.
Providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona slant shear test) to ensure bond between old concrete and new concrete complete all as per manufacturer's instructions and as directed by Engineer-in-Charge Make :- Krishna Conchem / Dr Fixit / Fosroc as approved by GE.
Building up the profile of structural member by using latex additives (MONOBOND) modified air cured motor system (Polymer modified motor/LW+) (1:5:15 = 1 monobond-5 cement -15 sand) -in damaged area in 30mm thickness including leveling profiling etc complete all as per manufacturer's instructions and upto 15th floor of building complete all as specified and directed by Engineer in charge. Make :- Dr Fixit / STP / Fosroc as approved by GE.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in charge.
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in charge.
M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide,complete all as specified and directed by Engineer in charge.
ASHOK CONSTRUCTION
BOB ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .