RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Truck Chassis Mounted Suction Cum Jetting Machine-Heavy ( 1 pieces ) Technical Specifications 1/12 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Certification Chassis Certification ARAI/VRDE/ICAT Yes * Chassis Certification ARAI/VRDE/ICAT No - * Form 22 A - For compliance with pollution standards
Requiredsafety standards of components and road worthiness as per CMVR Rules Yes * Conforming to IS:13496 for Suction Machine for cleaning Sewers
RequiredManholes and ancillary structures provided on sewer line and closed storm water drains Yes * Conforming to IS:11387 for high pressure jetting machine for sewer cleaning Yes * Availability of test reports for all critical components from the manufacturer or OEM of Jetting Pumps
Requiredvacuum pumps
Requiredpower takeoff unit
RequiredJetting Hose etc shall be from any ILAC/NABL accredited/Central Govt Lab to be furnished to buyers on demand Yes * Registration To Local RTO (Regional Transport Office)/RTA(Regional Transport Authority) By Seller - * NGT approval needs to be provided bu the Govt department - * Generic Parameters Make and Model of Vacuum Pump - * Make and Model of Jetting Pump - * 2/12 Make and Model of Jetting Hose - * Make and Model of PTO - * Make and Model of Hydraulic Motor - * Make and Model of Hydraulic Pump - * Make and Model of Suction Hose - * Make and Model of Jetting Nose - * Chassis Make and Model - * Chassis Model Number - * Chassis Type Heavy Motor Vehicle * Type of Fuel Diesel Diesel Chassis Gross Vehicle Weight 16200 More than 16200.0 Or higher Kerb Weight 4815 More than 4815.0 Or higher Engine Capacity (cc) 5670 * Pay Load Capacity (Tonne Load) 9 More than 9.0 Or higher Vehicle Emission Compliance BS-IV BS-IV Engine BHP 180 More than 180.0 Or higher Engine Torque Max@rpm 660 More than 660.0 Or higher Maximum Speed of Vehicle(KM/Hr) 80 * No of Speed/Forward Gears 6 * Braking Distance 5 * Gradeability of Vehicle (%) 31 More than 31.0 Or higher Wheel Base 4330 More than 4330.0 Or higher Engine Aspiration System Turbocharged Intercooler * Mount Type Truck Mounted Unit * Fuel Tank Capacity 400 More than 400.0 Or higher Constructional Capacity of Split - More than 400.0 Or 3/12 Parameters Shaft PTO of the vehicle (kgm) higher Overall Length 7710 * Overall Width 2432 * Equipment Length 5510 * Equipment Height 3200 * Equipment Rear Over Hang Yes * If Yes
RequiredDeclare Equipment Rear Over Hang 2110 * Type of Front Axle and Suspension System - * Type of Rear Axle and Suspension System - * Derrick Arm Available No * Vacuum Pump - Rotary Vane/Sliding Vane Yes * Type Of Cooling - * Vacuum Pump Flow (cum/hr) - More than 540.0 Or higher Vacuum Pump Power (hp@rpm) - * Vacuum Relief Valve Size 1.5 * Vacuum Suction Depth 8 * Suction Hose - Lightweight
Requiredheavy duty
Requiredreinforced
RequiredPVC along with quick connect coupling arrangement Yes * Suction Hose Internal Diameter - * Suction Hose Length 3 * Number of Suction Hose (Nos) 5 * Safety Equipments - * Silencer/Filter(Micro Strainer) Yes * Exhaust Silencer and injection cooling air Inlet Silencer/Filter Yes * Blower Outlet and Air- Exhaust Silencer Yes * 4/12 Check valve Yes * Vacuum Limitation Valve Yes * Drain Off valve Yes * High Pressure Jetting Pump With pressure regulating Arrangement Yes Yes Jetting Pump - Triplex plunger reciprocating pump Yes * Working Pressure Range of Jetting Pump 155 155.0 - 200.0 Or higher Water Flow for Pump of Jetting Machine (LPM) 269 More than 269.0 Or higher Pressure Relief Valve Size 2 * Jetting hose inner Diameter (Capable of withstanding one point five times the maximum pressure generated by the pump) 25 * Jetting Hose Length 120 * Number of Nozzles for removing Blockage (Conical Head) 1 * Number of Nozzles for Flushing Sewer lines( Round Head) 1 * Number of balanced Nozzles for dry silt 1 * Water storage Tank Capacity 5000 5000.0 Sludge Storage Tank capacity 3000 3000.0 Total Tank Capacity 8000 8000.0 Maximum working pressure of Jetting Hose 207 * Minimum Burst pressure of Jetting Hose 517 * Thickness of tank plate of SS 304 with proper 6 * 5/12 re inforcement to withstand the required forces Material of tank Mild Steel ( Grade -A ) confirming IS 2062 latest Mild Steel ( Grade -A ) confirming IS 2062 latest Surface preparation and finish of tank's Exterior - sanded prior to spray painting and spray painted with two coats of superior quality anti corrosive primer and two coats of enamel metal paint Yes * Surface preparation and finish of Tank's Interior - clean water two coats anti corrosive primer & two coats of grey enamel paint & Sludge shall be with two coats of epoxy paint to resist corrosion Yes * Provision for locking and unlocking arrangement of rear gate of tank
Requiredto be operated hydraulically for quick tipping and cleaning Yes * Hose Reel Drive operated by hydraulic motor Yes * Dished Head Yes * Tank Rear Door Opening by hydraulic system Yes * Reinforcement rings in pipes Yes * Hydraulic Pump Type Gear Type * Water Level Indicator Type (with safety coverage) - * Water Level Indicator Nos 2 * Thickness of Cover for Engine
RequiredPump and Hose Reel compartment 3 * Material of Cover for MS Sheet * 6/12 Engine
RequiredPump and Hose Reel compartment Full bore Quick Acting Valves in the sewage path Yes * Air Pumps to safeguard the pump from overloading Yes * Make and Model of Air Pump - * Sludge Trap between the Air Pump and the Tank Yes * Float cut out valve to seal the pump suction line Yes * Lubricating system for reducing friction loss Yes * Three sewer cleaning nozzles with varying rearward angles Yes * One nozzle extension for easy fixing of the hose and the nozzle Yes * Two stop tank strainer elements Yes * Two sets of operation and service manuals and spare parts lists Yes * Hose guide Yes * Counter Yes * Essential Spares Set of seal kit for Hydraulic Cylinder Yes Yes Set of seal kit for Hydraulic Motors Yes Yes Set of seal kit for Hydraulic Pumps Yes Yes Set of Filters for Hydraulic Systems Yes Yes Suction hose 30mtr and Jetting hose 120mtr Yes Yes Performance Parameters Warranty Time 24 More than 24.0 Or higher Warranty Distance 20000 * No of Free Service (Minimum 3 per year) Yes * 7/12 * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters