| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.3 L+₹2.8 L (9.25%)Rejected-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹33.8 L+₹3.4 L (11.0%)Rejected-AOC | L3 | Rejected-AOC Not Lowest Bidder | |
| 4 | L4₹35.7 L+₹5.3 L (17.2%)Rejected-AOC | L4 | Rejected-AOC Not Lowest Bidder | |
| 5 | L5₹37.5 L+₹7.0 L (22.9%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L5 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹39.9 L
EMD Value
₹80,000
Closing Date
21 Nov 2022, 6:00 pmClosed
Garrison Engineer, St.Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS MAINT OF INTERNAL ELECTRIC SUPPLY AND OTHER ELECTRIFICATION WORKS IN MAP ACCN , PO COLONY, USMAN LINE, OFFICERS MESS AND AT OTA AND REPAIRS TO LOW TENSION EXTERNAL ELECTRIC SUPPLY AND ALLIED WORKS FOR MH,100 ORs QTRS DEFENCE COLONY MD A
2022_MES_558270_1
8302-REPAIRS/MAINT OF INTERNAL ELECTRIC SUPPLY AND
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE STM
As per tender documents
6 documents required · 6 mandatory
₹500
Garrison Engineer, St Thomas Mount
₹80,000
Yes
30 Jan 2023
17 Oct 2022
28 Nov 2022
17 Oct 2022
21 Nov 2022
2 Nov 2022
17 Oct 2022 - 28 Oct 2022
Amount
Taking down carefully copper/ Aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit.
M & L for Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable FRLS 1100 volts grade, multistranded with copper conductors conforming to IS specifications, with colour code drawn through and including non metallic rigid PVC conduit, PVC conduit fittings and conduit accessories or casing capping incl accessories fixed on wall / ceiling or concealed on wall and fixed on ceiling etc with suitable clamps, screws, etc or concealed in wall including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth ,including Provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified and as directed :-
(a) One light point controlled by one switch
(b) One fan point controlled by one switch and one regulator
(c) One 3 pin 5 Amps switch socket on independent board
(d) One 3 pine 5 amps switch socket on same board alongwith other switches.
(e) One bell point controlled by bell push switch on independent board.
All as per item No 2 herein before but with 2.5 Sqmm single core PVC cable for one 3 pin 15 amps switch socket outlet on independent board.
M & L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications,2 runs of 10 sqmm including one run of 10 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsv all as specified and directed.
All as per item No 4 herein above but with 2 runs of 6 Sqmm and one run of 1x 6sqmm earth wire in PVC conduit as specified and as directed.
All as per item No 4 herein above but with 2 runs of 4 Sqmm and one run of 1x 4 sqmm earth wire in PVC conduit as specified and as directed.
All as per item No4 herein above but with 2 X 2 .5 sq. mm + 1 X 2.5 sq. mm earth wire in PVC conduit or casing capping as specified and as directed.
All as per item No4 herein above but with 2 X 1.5 sq. mm + 1x1.5 sq. mm earth wire in PVC conduit or casing capping as specified and as directed.
All as per item No 4 herein above but with 4 runs of 10 sqmm and one run of 2 x 10 sq.mm earth wire in PVC conduit as specified and as directed. Note for item Nos 4 to 8 :- (a) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (b) For concealed wiring wherever required cutting chases will be measured separately under relevant items.
Supply and fix flexible PVC pipe of 25 -40 mm dia complete all as specified and directed
Supply and Fix Rigid Non metallic PVC Conduit 20 mm dia including Removing old UNSV conduit all As Directed. Note: The quoted rate shall be inclusive of removing old wiring and drawing the same after removal of conduit
S& F Ceiling rose surface Bakelite 65mm x 50 mm two to three terminals all as directed.
Supply and fix round block 8 cm dia and 4 cm depth open recessed all as directed.
Supply and Fix Switch piano flush type 5 amps single pole, one way, 240 Volts all as directed.
Supply and Fix Switch socket outlet 3 pin, 5 amp, flush type all as directed.
Supply and Fix Socket outlet 3 pin 5 Amps flush type all as directed.
Supply and Fix Bell push flush type 5 amps single pole 240 Volts all as directed.
Supply and Fix Buzzer, AC, 230 volts, single pole all as directed.
Supply and Fix Bell ding dong, AC, 230 volts, single pole all as directed.
Supply & Fix Bell Musical type all as specified and as directed.
Supply and Fix Socket outlet 3 pin 15 amps flush type all as directed.
Supply and Fix Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch all as directed.
S & F stepped type electronic fan regulator flush type on the exiting phenolic laminated sheet extra as required.
Supply and Fix Modular Switch Roma flush DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Switch flush DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Switch Roma flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Switch flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Socket Roma flush DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Socket DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Socket Roma flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix Modular Socket flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed.
Supply and Fix PVC Gang box surface type suitable for fixing of 5 pin 15 Amp multipurpose switch socket on wall complete all as specified
Supply and Fix PVC Gang box surface type suitable for fixing of 5 pin 5 Amp multipurpose switch socket on wall complete all as specified
S & F Lamp holder insulated body with 1X11W LED bulb complete all as specified and as directed.
S & F Modular Fan step regulator, 120W - 1 module for ceiling Fan of 1200 mm sweep all as specified and as directed. Make: Havells, Cat Part No: AHORFXW004 or equivalent in Anchor ROMA
S&F Modular white cover with plate with frame 2 module incl matching with white cement wk if necessary
S&F Modular white cover with plate with frame 3 module incl matching with white cement wk if necessary
S&F Modular white cover with plate with frame 4 module incl matching with white cement wk if necessary
S&F Modular white cover with plate with frame 6 module incl matching with white cement wk if necessary
S&F Modular white cover with plate with frame 8 module incl matching with white cement wk if necessary
S&F Modular white cover with plate with frame 12 module incl matching with white cement wk if necessary
S&F Modular white cover with plate with frame 16 module incl matching with white cement wk if necessary
Supply and Modular flush box 1/2 module
Supply and Modular flush box 3 module
Supply and Modular flush box 4 module
Supply and Modular flush box 6 module
Supply and replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 230 Volts 20/32 Amps all as specified and as directed.
Supply and fix MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory all as specified and directed.
Supply and fix MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 8 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory all as specified and directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 4 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
Supply & Fix MCB Four pole 415 volts, 40 to 100 amps 'C' Curve 10 kA Capacity all as directed.
Supply and fix MCB SPN, 240 Volts, 32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one.
Supply and fix MCB SP, 240 Volt,5-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one.
Taking down the old UNSV LED Tube and taken as credit including Supply and fix LED tube Single end connection Ultra bright LED polycarbonate Tubelight with very high efficacy suited for installation in existing T8 fittingwith G13 lamp holders. LED tube all as specified and as directed.
Taking down the old UNSV Light fitting and taken as credit including Supply and fix Wall mounted LED Batten with tube extruded Aluminium heat sink provided for efficient heat dissipation & integrated electronic driver of Lamp type: 22W LED including lamp all as specified and as directed.
Taking down the old UNSV Light fitting and taken as credit including Supply and fix Wall mounted Endural LED Batten, high efficacy - 1051m/W, Short circuit & Voltage cut off protection, wide operating voltage range of 140V to 270V wide, lumen output of 4000 , 38W including lamp all as specified and as directed.
Taking down the old UNSV Light fitting and taken as credit including Supply and fix Wall mounted LED Batten, Aluminium Housing & integrated electronic driver of Lamp type: 10W LED life time of 30000* hours including lamp all as specified and as directed.
Taking down the old UNSV Light fitting and taken as credit including Supply, Installation, testing and commissioning of Surface mounted LED luminaries with Mid flux LED using efficient optics , System lumen efficacy > 80Lumen/Watt , System Luminous flux of >=3200 lumens, System Wattage <=42W with 50,000 hours burning life. Color rendering index > 70 and Color temperature 5000K/6500K. CRCA housing with high efficiency opal diffuser. Luminaries sealed from bottom. Inbuilt gear . Zero maintenance, Zero mercury. Driver Surge protection > 1.5kV. Electronic In-Built PF > 0.9 , THD < 10% , IEC Compliant for Safety , Performance & EMI. The type shall be of 2'x2'.
Taking down the old UNSV Light fitting and taken as credit including Supply, Installation, testing and commissioning of Surface mounted LED luminaries with Mid flux LED using efficient optics , System lumen efficacy > 80Lumen/Watt , System Luminous flux of >=3200 lumens, System Wattage <=15W with 50,000 hours burning life. Color rendering index > 70 and Color temperature 5000K/6500K. CRCA housing with high efficiency opal diffuser. Luminaries sealed from bottom. Inbuilt gear . Zero maintenance, Zero mercury. Driver Surge protection > 1.5kV. Electronic In-Built PF > 0.9 , THD < 10% , IEC Compliant for Safety , Performance & EMI. The type shall be of 1'x1'.
Taking down the old UNSV Light fitting and taken as credit including Supply, Installation, testing and commissioning of 15 W Surface mounted LED luminaries down lighter with white powder coated aluminium housing with integrated electric driver.
Taking down the old UNSV Light fitting and taken as credit including Supply and Fix Endura Bulk head fitting 10W Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LED s all as specified and as directed.
Taking down the old UNSV Light fitting and taken as credit including S&F LED 35 W well glass luminaries equipped with new age technology which consume less energy without compromising the lighting level, highly durable, usable in rugged environment for Bldg Security. Including making suitable provision for mounting the fitting complete all as specified and as directed. Make : Bajaj Cat Part No 169851 BGWD 27W LED NW or Equivalent in Philips/ Wipro
Taking down the old UNSV Bed lamp fitting and taken as credit including Supply, Installation, testing and commissioning of LED Wall light with system wattage not more than 4W, using 3W for LEDs. The lumen output of LED shall be (Light source) shall not less than 230 lumens. The housing shall be of aluminium and white color coating. The head of the luminaries shall be adjustable type. The beam angle shall be < 50 deg. Lamp lifetime up to: 15,000 hrs. Total lumen output fixture: > 170 lm. Bulb technology: LED, Safety Extra Low Voltage. Mains power: Range 220 V–240 V, 50-60 Hz. IP code: IP20, protection against objects bigger than 12.5 mm, no protection against water. Class of protection: I - earthed. The luminaries shall be integrated type. The Net weight shall not exceed 0.3 kg.
S & F Bldg Sec lights 30 W IP 66 road way luminarie with high powers LEDs as light source and electronic driver with mounting GI Pipe 40 mm dia 900 mm long fixed on wall complete all as specified and directed.
Supply and fix Wall mounted Regal Batten for T8 LED Tube for all as specified and as directed.
Supply and fix in replacement of LED Bulb 12W Suitable for Batten/ Pendant holder all as specified and as directed.
Dismantling existing UNSV hylam sheet of any size from boards removing switches etc. Supply and fix hylam sheet 3mm thick including necessary cutting of suitable opening for switches, sockets, regulators, etc refixing of switches, sockets, regulators, etc replacing screws and connecting up and testing.
Repairs to fluorescent tube light fittings fixed on wall/ceiling/suspended etc., upto 2 x 40 watts, any type/make/model, by replacing following unserviceable items/parts by supply and fixing including checking and rectifying defects in internal wirings and testing all as specified and directed :-
(a) Choke 40/36 watts
(b) Choke 28 watts for EEFTL fittings
(c) Starters 40/20 watts , 240 V / 110 V.
(d) Tube 36/40 watts
(e) Tube 28/20 watts T5
(f) Tube Light Side Holder with suitable Screws
Supply and Replacement CFL lamp 13/11w 2P/4P
Supply and Replacement CFL lamp 18w 4 Pin/2 cross pin
Supply and Replacement CFL lamp Retro fit 20w direct fit type
Supply and Replacement CFL lamp warm white(yellow) Retro fit 11/14 w direct fit type
Supply and Replacement 11/13 w choke suitable for Mirror Fittings
Supply and Replacement CFL lamp 36 W 2P/4P
Supply and fix in repair of retrofit lamp 11 watt E-27/B22 type suitable for 230 Volts 50 Hz AC supply complete including taking out old/unserviceable complete as directed Make : Havells /Bajaj/Phillips
Supply and Replacement of colored Globe type Incandescent bulb 15 watts with Red/Green Glass Thread type for engagement Fitting
Supply and Replacement of Fancy Flame type Incandescent bulb 15 watts with Clear/Milky Glass Thread type.
Supply and Replacement of lamp Halogen 50 w 12 Volts DC 2P.
Supply and laying 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed twin core 4 sq. mm nominal cross section in service connections.
All as per item No 81 herein above but 6 sq.mm twin core.
M&L painting of ceiling fan complete , using spray gun, in site with synthetic enamel paint by spraying including filling cavaties with filler , one coat after cleaning all dust complete all as specified and directed
Taking down Fans ceiling/Exhaust/wall of any sweep, capacity make,model,sealing cable and dismantling blades, removing fan and blades for repair/servicing/replacement of parts/rewinding and refixing the same after replacement of spares and parts servicing rewinding complete all as specified. Note : spare parts and rewinding and servicing shall be measured separately
Dismantling the following types of fans of any make/model/sweep, overhauling /servicing, greasing/lubricating, insulating electric leads, replacing cotter pins, bolts and nuts with copper pin, assembling back, checking for proper fixing and safety and testing all as specified and directed for ceiling fan, exhaust fan, wall fan, pedestal fan upto 1400 mm sweep:
Dismantling the following types of fans of any make/model/sweep, removing the burnt out winding wires, rewinding with winding wires and insulation materials overhauling/servicing, greasing/lubricating, insulating electric leads, replacing cotter pins, bolts nuts, replacing unserviceable bearing, bushes assembling back checking for proper fixing and safety and testing all as directed and specified for :-
(a) ceiling fan upto 1400 mm (56") sweep.
(b) Exhaust fan upto 450 mm sweep.
(c) Wall mounting/ Pedestal fan/air circulator upto 600 mm sweep.
Removing following unserviceable parts/items, supply and fix new items/parts of same materials existing and as described below for ceiling/exhaust/pedestal fans etc
(a) Ball bearing for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep.
(b) Bush bearing for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep.
(c) Fan condenser capacitor 2.5 mfd.
(d) Fan condenser capacitor 4 mfd.
(e) Fan condenser capacitor 6 mfd.
(f) Fan clamp for ceiling fan complete with rubber shackle, shackle bolt, nut, cotter pin, clamp complete.
(g) Down rod 15 mm dia medium grade including cutting required length, drilling holes, painting complete.
(h) Fan blade of existing model/Make/Type for upto 1400 mm sweep
(i) Shaft assembly including lath works complete for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep
Taking Down and Refixing incl Painting of water heaters (Geysers) of following capacity of any make/model in site with synthetic enamel paint by brush including filling of cavaties with fillers one coat after cleaning all dust etc including writing MES numbers etc all as specified and directed for :
(a) Water heater 25 liters capacity.
(b) Water heater 50 liters capacity.
Dismantling following unserviceable items/parts from water heaters of any capacity/make/model, supply and fix new items/parts of same capacity/type/model, connecting up and testing :-
(a) Heating element 1.5 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
(b) Heating element 2.0 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
(c) Thermostat suitable for water heater upto 50 liters capacity.
(d) Indicator lamp any type suitable for water heaters upto 50 liters capacity.
(e) Non return valve 15 mm dia size.
(f) PVC connections with brass check nuts 15 mm dia x 45 cm long for hot water supply.
(g) PVC connections with brass check nuts 15 mm dia x 45 cm long for cold water supply.
(h) Rubber gasket flat/'O' ring type suitable for water heater
(j) PVC cable 3 core flexible copper conductor cable of size 40/0.193
(k) Plug top 3 pin 15 amps.
(l) Pressure release Valve suitable for geysers upto 50 liters capacity.
Removing the old rusted /worn out MS bolts and nuts and grouting 4 nos new MS "T" bolts and nuts in brick walls ( MS bolt size 3/8 " x 6" with washers ) and making good the disturbed surfaces incl plastering , curing etc all as directed.
M & L for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel earth wire 4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 5 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed.
Supply & Fixing of LED driver for LED fittings upto 40Watts of Any size/type make: Philips/Havells/ Crompton/Bajaj Note : 1. The complaints slip books and Register etc will be provided by contractort. Whose rates are deemed to be included in the above quotated rate. 2. Daily min one Electrician and one helper will report to GE STM complaint cell at 9:00 hours for attending day to day complaints include sunday & holiday.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of stays & Poles, laying of cables etc and getting out in soft / loose soil all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm using excavated soil all as specified and directed.
Removing excavated material/ surplus soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply, lay / spread in trenches, sieving sand including cleaning, spreading, leveling, punning for laying /cushioning of cable all as specified and as directed. Note: Punned thickness shall be measured and paid.
Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mm x 40mm complete including removing old bricks from trenches and taken as schedule of credit.
M&L for Cement concrete Type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete including form work.
M&L for Cement concrete Type C 1 1:3:6 (20mm graded aggregate) for coping to the poles with finishes with out using extra cement.
Disconnecting and taking out the old unserviceable LT UG cable in trenches,wall & poles and taken as credit including supply and Laying in trenches / poles / wall etc LT UG Cable XLPE insulated, armoured, heavy duty with multistranded aluminium conductor, 1100 volts grade conforming to IS specifications and of the following sizes:- Note: Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used wherever required while connecting cables to the panel board. Earth work such as excavation, refilling etc, shall be measured and paid separately under relevant item:-
(a) LT UG cable 2 core 10 sqmm
(b) LT UG cable 4 core 16sqmm
(c) LT UG cable 4 core 25sqmm
(d ) LT UG cable 3.5 core 35sqmm
(e) LT UG cable 3.5 core 50sqmm
(f) LT UG cable 3.5 core 70sqmm
(g) LT UG cable 3.5 core 95 sqmm
(h) LT UG cable 3.5 core 120sqmm
(j) LT UG cable 3.5 core 185sqmm
Re- laying only ( where directed at site) in trenches and connecting with suitable size of cable jointing kit/lugs/ thimble etc. serviceable under ground cable retrived from taking out as Srl No - 09 of above schedule of following sizes:- Note:- Cable jointing kit will be measured & paid separately under relevant items of Sch 'A'.
(a) LT UG cable 4 core 16 sqmm
(b) LT UG cable 4 core 25 sqmm
(c ) LT UG cable 3.5 core 35 sqmm
(d) LT UG cable 3.5 core 50 sqmm
(e) LT UG cable 3.5 core 70 sqmm
(f) LT UG cable 3.5 core 95 sqmm
(f) LT UG cable 3.5 core 120 sqmm
(f) LT UG cable 3.5 core 185 sqmm
S&F Straight through joints (epoxy) heat shrink type for underground cable including joint kits and labour complete for making joints suitable for LT PVC sheathed / armoured heavy duty cables with aluminium conductor of following sizes :-
(a) LT UG cable upto 4 core 16
(b) LT UG cable 3.5/4 core 25 sqmm to 50
(c ) LT UG cable 3.5 core 70 to150sqmm
(d) LT UG cable 3.5 core 185 to 300 sqmm
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 40mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 80mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Supply and lay in repairs steel tubes, 'light grade' galvanised, with all fittings; of bore of tube 100mm laid in trenches for drawing cables under road/drain crossings etc all as specified and directed
Taking down the old unserviceable junction box and taken as credit including S&F Junction box PVC (FRP) Junction Boxes weather proof type with hinged type door off white colour of size 240x130x110mm with three pole connector and 1 No neutral link complete fixed on pole with suitable clamps, bolts and nuts with fixing arrangements all as specified and directed. Make : Sintex or equivalent.
Dismantling steel poles/ struts, any size including pcc couping.
Supply and erect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP- 31 (9.00 metres long) conforming to IS-2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bitumenous paint over the embeded portion of pole, erecting in truly vertical position including excavation in any strata and earth work complete all as specified and directed. Note :- PCC for foundation and coping will be measured & paid separately under relevant items of Sch 'A'.
M&L for removing the existing street light fitting of any type & make and Supply & installation of new street light fittings,60W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and directed Make:- Havells , Cat part No. ENDURAPEARLNEOSL60WLED757PASYTOPCAST / crompton cat part No. LSTP-60-CDL-M/ Wipro skyline LED cat No. LR02-671-XXX-57-XX./Bajaj cat No.ENXT P 60L WW CR PC SD.
M & L for dismantling and taking down the existing street light fitting led type for repair and replacing the unservicable LED driver with new upto 100W LED 5700K and refixing the same in the existing pole duly wired complete all as specified and directed.
M&L for removing the existing street light fitting of any type & make and Supply & installation of new 90 W LED 5700K New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaries with high power LED as light source in the existing pole duly wired complete all as specified and directed Make:- Havells Cat part ENDURAOMNIPLUSSL90WLED757SASYTOPC /crompton cat part No. LSTP-90-CDL-M/ Wipro skyline LED cat No. LR02-102-XXX-57-XX/ Bajaj cat No. BRTFG 90W LED CR WW.
Removing the existing Gate light & Supply and installation of new 35W LED 5700K New generation Post top energy saving & environmental friendly long life versatile spun aluminium IP66 roadway luminaries with high power LED as light source and connecting in the existing cable complete all as specified and directed Make:- Havells Cat part RUBYPT35WLED757PSYMTOPC/ CROPTON cat no- LPTC-40-CDL/ BAJAJ cat no. BGCT W4 LED WW 40W LED
Removing the existing unserviceable bollards light & Supply and installation of new 9 W/10W LED bamboo series IP 65, out door luminaires, New generation energy saving & environmental friendly long life aesthetically designed aluminium land scape luminarire for diffused lighting with high power LED Bollards as light source and connecting in the existing cable complete all as specified and directed Make:- Havells Cat part MOUNTBL10WLED830PSYMTOPMMA/ BAJAJ cat No. BGBOL 605 9W LED WW / CROMPTON cat No. LBLA-10-CDL.
Supply and laying 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 3 core 2.5 sq. mm nominal cross section in service connections/strret light connection from junction box to street light fittings.
Dismantling unserviceable power factor improvement capacitor of various capacities and Supply and fix heavy duty Cylindrical capacitors AC 440 volts, 50 Hz, Delta connection new power factor improvement capacitor of following capacities complete all as specified and directed. Make : havells, ABB or equivalent
(a) 25 KVAR Capacity
(b) 20.0 KVAr Capacity
(c ) 15 KVAR Capacity
(d) 10 KVAR Capacity
(e) 5 KVAR Capacity
(f) 3 KVAR Capcity
Dismantling unserviceable capacitor duty contactor and Supply and fix capacitor duty contactor of following capacities complete all as specified and directed. Make : havells, ABB or equivalent
(a) 25 KVAR Capacity
(b) 20.0 KVAr Capacity
(c ) 15 KVAR Capacity
(d) 10 KVAR Capacity
(e) 5 KVAR Capacity
(f) 3 KVAR Capcity
S & F MCCB 3 pole 400 Amps,415 volts with rupturing capacity 36 KA. All as specified including taking out old one.
S & F MCCB 3 pole 250 Amps,415 volts with rupturing capacity 25 KA. All as specified including taking out old one
S & F MCCB 3 pole 125 Amps,415 volts with rupturing capacity 16KA. All as specified including taking out old one
S & F MCCB 3 pole 25 to 100 Amps,415 volts with rupturing capacity 16 KA. All as specified including taking out old one.
Removing of old earthing including earth plate and M&L for Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with the top edge of earth plate at depth not less than 1.5 Mtr below ground level connected to galvanised iron earth strip 32 X 6 mm by means of bolts, washers ,watering pipe 20mm dia, medium grade GI pipe,with welded funnel and wire mesh and 40mm dia medium grade GI pipe with fitting as protection pipe for strip from plate electrode to test point /plant/machineries etc. including necessary excavation and earth work in any type of soil, salt, charcoal dust, concrete pit in PCC (1:3:6) type C-I having outer dimension 60cmx60cmx60cm and internal dimension 30cmx30cmx30cm, pre-caste RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia deformed bares @15 cm centre to centre both direction and 10 mm dia MS handle of suitable size charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in electrical plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
Preparation of old surface and painting of steel tubular electric poles above coping level including brackets,clamps etc with good quality silver paint(two coat) complete including writing pole no and all as specified and directed.
Finding and rectification of electrical fault by Checking of external/internal(LT) elect supply feeder, street light feeder,OH conductors /under ground cables using elect tools, equipments and safty devices after arranging elect shut down of feeders from sub station to remove elect faults like tightning of loose connection,removing of any electric short,meggring of cable,excavation of soil for removing of faulty cable on a particular span and relaying of cables after removing of fault, re-tightning of cable lugs etc all as required at site and as directed by Engr in Charge. Note:- (i) The electrician employed for the purpose will be highly skilled along with one mate and should have all necessary tools and safty devices. (ii) Any major materials used for rectification of faults like Cables,MCB/MCCB/cable jointing kits/cables of any type etc will be measured and paid seperately or supplied by department.(iii) Rate including hire of HT/LT fault Locaterany other tools/equipments and Earth Work. works should be completed with in 12 hrs.
Material and labour for servicing DG Set Engine complete oil servicing, necessary replacement of below mentioned spares and servicing work for 380 KVA DG Set incl 6 months warrantee for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant as required.
Material and labour for general oil servicing of DG Set Engine complete and replacement of below mentioned spares and servicing work for 15 KVA DG Set incl 6 months warranty for servicing .(a) Diesel Filter (Pre+micro) - 2Nos, (b) Engine Oil filter (Spain-on type) - 2 Nos, (c) Engine Oil as required, (d) Radiator Coolant - 1 Ltrs.
Dismantling self starter of any make from diesel engines of any make, opening up, overhauling / servicing including replacement of armature coils bushes carbon brushes, springs, screws, etc., assembling back, re-fixing and testing for genset capacity following capacity:-
(a) DG set 380 KVA
(b) DG set 15 KVA
M&L fuel pump & Fuel injectors calibration charges for DG set capacity upto 380 KVA complete all as specified and as directed by Eng-in-Charge.
'V' belt for fan / dynamo / water pumps for genset capacity upto 380 KVA (Make : FENNER / DUNLOP)
M&L for replacement of automatic voltage regulator (AVR) of armature of DG set capcity upto 380 KVA, 415 volts 3 phase 1500 RPM 50 Hz suitable make.
Material & Labour for Cutting and cleaning the tree branches around the street light poles/ /sub stn/ LT OH lineconductors and maintain 2 mtr gap all around free from branches of tree and clear the site and throw away cut branches etc, to a distance exceeding 50m all as directed. Note: Span shall be measured along with the direction of OH/ LT.
M/S.RANGA AND CO
RADHIKAGANESH ENTERPRISES
PSK Enterprises
P Damodharan
Bidder Name
P Damodharan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .