Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 CrAccepted-Finance H NO 164 SECTOR 8 PANCHKULA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹6.3 Cr | L1 | Accepted-Finance Accepted |
| 2 | L2₹6.4 Cr+₹14.2 L (2.26%)Accepted-Finance | ₹6.4 Cr+₹14.2 L (2.26%) | L2 | Accepted-Finance Accepted |
| 3 | Rejected-Technical MD22 ELDECO MENSIONZ SOHNA ROAD NEAR FAZILPUR CHOCK GURGAON FF 19 OMAXE GURGAON MALL SOHNA ROAD GURUGRAM 2021R5777 | GURUGRAM | GURUGRAM | HARYANA | - | - | Rejected-Technical Rejected |
| 4 | Rejected-Technical 5546 NICHOLSON ROAD SADAR BAZAR AMBALA HARYANA 133001 | AMBALA | HARYANA | 133001 | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | GS Enterprises L2 | JAI BHARAT CONSTRUCTION COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Designing, providing, fixing, testing and commissioning of AUTO-SHUT OFF VALVE as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 32 | Nos. | 96,750 ₹30,96,000 | 95,000 ₹30,40,000 Lowest |
| 2.00 | Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM WITH ALTERNATE CHLORINATOR as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 16 | Complete Job | 5,55,460 ₹88,87,360 | 5,50,000 ₹88,00,000 Lowest |
| 3.00 | Designing, providing, fixing, testing and commissioning of GASEOUS CHLORINATION SYSTEM having capacity upto 2000 grams/hrs. as designed having the control of gas upto 20th part of max. dose . The complete system consists of (a) Vacuum regulator (b)Measuring Glass Tube (c ) Ejector (d) PF tubing (e) Spanner with cylinder opening key (f) Ammonia Gas (Liquid for leaking test) (g) 1’dia PVC pipe with PVC fitting, ball valves etc. (h) 2 Nos. chlorine gas cylinder capacity 100 Kg. duly certified and approved by BIS and Explosive Department Govt. of India (i) Electronic Chlorine gas leak detector with sensor and hooter (j) Full face mask with canister as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 16 | Complete Job | 5,60,220 ₹89,63,520 | 5,50,000 ₹88,00,000 Lowest |
| 4.00 | Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY SCRUBBER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 16 | Complete Job | 9,05,000 ₹1,44,80,000 | 9,00,000 ₹1,44,00,000 Lowest |
| 5.00 | Designing, providing, fixing, testing and commissioning of ONLINE COLORIMETRIC WATER QUALITY ANALYZER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024. | 16 | Complete Job | 3,54,800 ₹56,76,800 | 3,50,000 ₹56,00,000 Lowest |
| 6.00 | Designing, providing, testing and commissioning of genset of 10 KVA 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with engine complete with suitable size incoming cable from generator to change over/AMF panel for chlorine gas dry scrubbing system complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Engine b) Alternator c) Battery 24 v. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Overload protection for DC-1 No. h) Battery Charger 24V DC i)Copper bus bar of suitable size j) KWH meter 96 sqmm size k) Starting fuse button and key switch (on/off) and other required accessories complete in all respects to the satisfaction of Engineer-in-charge. | 16 | Complete Job | 3,12,545 ₹50,00,720 | 2,80,000 ₹44,80,000 Lowest |
| 7.00 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 1st year | 1 | Complete Job | 35,80,800 ₹35,80,800 | 32,64,000 ₹32,64,000 Lowest |
| 8.00 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 2nd year | 1 | Complete Job | 35,80,800 ₹35,80,800 | 33,79,200 ₹33,79,200 Lowest |
| 9.00 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 3rd year | 1 | Complete Job | 35,80,800 ₹35,80,800 | 34,94,400 ₹34,94,400 Lowest |
| 10.00 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 4th year | 1 | Complete Job | 35,80,800 ₹35,80,800 Lowest | 36,09,600 ₹36,09,600 |
Tender Value
₹6.0 Cr
EMD Value
₹12.0 L
Closing Date
25 Jun 2026, 3:00 pmClosed
HEMANT KUMAR
Palwal PHED No. 3
Estimate for installation of gaseous chlorination system with automation system in 17 No Water Boosting Stations of Various Water Supply Schemes. i.e. Bhulwana, Pingaltu, Gorota, Maroli, Jalalpur Maufi, Dakora, Banswa, Aurangabad, Mitrol, Dee
2026_HRY_528133_1
20269DC69D15 D82D 47E7 A5C8 76CE385C0DAE561PUH
Open Tender
Civil Works
Works
330 days
BHULWANA PAINGALTU GAROTA DAKORA BANSWAN AURA
Refer to tender documents
2 documents required · 2 mandatory
₹20,000
₹12.0 L
Yes
2 Sept 2026
11 Jun 2026
25 Jun 2026
11 Jun 2026
25 Jun 2026
11 Jun 2026
11 Jun 2026 - 13 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Designing, providing, fixing, testing and commissioning of AUTO-SHUT OFF VALVE as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 32 | Nos. | - | - |
| 2 | Designing, providing, fixing, testing and commissioning of VACUUM-OPERATED AUTOMATIC SWITCHOVER SYSTEM WITH ALTERNATE CHLORINATOR as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 16 | Complete Job | - | - |
| 3 | Designing, providing, fixing, testing and commissioning of GASEOUS CHLORINATION SYSTEM having capacity upto 2000 grams/hrs. as designed having the control of gas upto 20th part of max. dose . The complete system consists of (a) Vacuum regulator (b)Measuring Glass Tube (c ) Ejector (d) PF tubing (e) Spanner with cylinder opening key (f) Ammonia Gas (Liquid for leaking test) (g) 1’dia PVC pipe with PVC fitting, ball valves etc. (h) 2 Nos. chlorine gas cylinder capacity 100 Kg. duly certified and approved by BIS and Explosive Department Govt. of India (i) Electronic Chlorine gas leak detector with sensor and hooter (j) Full face mask with canister as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 16 | Complete Job | - | - |
| 4 | Designing, providing, fixing, testing and commissioning of CHLORINE GAS DRY SCRUBBER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024.. | 16 | Complete Job | - | - |
| 5 | Designing, providing, fixing, testing and commissioning of ONLINE COLORIMETRIC WATER QUALITY ANALYZER as per technical specifications issued by Head Office, PHED, Haryana Memo No.-23070-23142 dated 28-02-2024. | 16 | Complete Job | - | - |
| 6 | Designing, providing, testing and commissioning of genset of 10 KVA 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with engine complete with suitable size incoming cable from generator to change over/AMF panel for chlorine gas dry scrubbing system complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Engine b) Alternator c) Battery 24 v. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Overload protection for DC-1 No. h) Battery Charger 24V DC i)Copper bus bar of suitable size j) KWH meter 96 sqmm size k) Starting fuse button and key switch (on/off) and other required accessories complete in all respects to the satisfaction of Engineer-in-charge. | 16 | Complete Job | - | - |
| 7 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 1st year | 1 | Complete Job | - | - |
| 8 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 2nd year | 1 | Complete Job | - | - |
| 9 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 3rd year | 1 | Complete Job | - | - |
| 10 | Comprehensive maintenance of complete system under this DNIT in all respect including replacement of any part and consumables including reagents of original make, SIM data cost, network and cloud storage etc for 4th year | 1 | Complete Job | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_607131.xls
BOQ • 0.22 MB
777982Z164459.pdf
Additional Documents • 9.78 MB
OT0164459.pdf
Other Document • 1.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .