Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
4 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRAWING
29 conditions · 9 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) Attested Certificates(s) issued by Executive or Nominated Authority of the government Departments or Semi-Government/Public Sector Undertakings for the value of the work done for them during the qualifying period including current financial year certifying the bill amounts paid Agreement-wise and Date-wise or attested photo copy of such certificate. Such certificates will be accepted only from Govt. / Govt. bodies / PSUs authorities. Certificates issued by Private Bodies will not be considered.
(b) Audited Balance Sheets clearly indicating contractual receipts from the works done for Govt./ Govt. bodies / PSUs/Pvt. Organization in the P&L Account of the balance sheet duly certified by the Chartered Accountant for the completed & current Financial years.
NOTE: (i) Financial Year shall normally, be reckoned as 1st April to 31 st March of the Next Year. However, for Turnover Criteria, the Financial Year as applicable to the Company /Tenderer is to be considered, if it defers from the above. (ii) Current Financial year is reckoned as the incomplete Financial year in which the date of tender submission falls. (iii) Chartered Accountant statements duly indicating yearly receipts will not be considered until and unless backed by Audited Balance Sheets. (iv) If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
If JV firms are allowed to participate; Financial eligibility of the JV Firm shall be adjudged based on satisfactory fulfilment of the Para No.17.15.2 of part-I of IRSGCC- 2019 for J.V guide lines (with upto date correction slip).
NOTE: If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
Valid Electrical Contractor license: "The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650V. Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected". The License should have been issued on a date prior to the date of Tender opening. Clear scanned copy is to be submitted along with the tender. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
Similar Nature of work: "Works of wiring/cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements, earthing etc (with or without supply of items/equipments) for 230V, 1phase or 415V, 3phase system or higher voltages". a copy of similar nature of work should be uploaded through IREPS with their offer, failing which the tender will be rejected.
94 conditions · 9 needing a document upload
TENDER SHALL BE REJECTED if it is not accompanied by the following:
Cost of tender document & EMD deposited through IREPS e- payment
In case of Partnership firm : The tender form shall be submitted only in the name of partnership firm.
In case tenderer is JV Firm : The tender form shall be submitted 1.1.2 only in the name of the JV and not in the name of any constituent member.
Uploading of Certificate in support of Technical Eligibility (As detailed in Standard Technical Criteria).
Submission of Certificate(s) in support of Financial Eligibility (As detailed in Standard financial criteria).
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 20 CRORES: Bid capacity is applicable, the tenderers should submit proforma attached in DOCUMENTS. In case, the tenderer/s failed 1.3.1 to upload BID CAPACITY PROFORMA along with offer, their/his offer shall be considered as incomplete and will be rejected summarily.
In case tenderer is other than sole proprietorship firm, following documents shall be uploaded by the tenderer:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered). [iv]An undertaking by all partners of the partnership firm that they are not blacklisted or 1.4.1 debarred by Railways or any other Ministry / Department of the Govt. of India / any State Govt. from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 1.4.2 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of 1.4.3 Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv) copy of PAN number of the Company.
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 1.4.4 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Incase JV Firms are allowed to participate: Uploading of MEMORANDUM OF UNDERSTANDING as per the format given in "Documents attached with tender" and also below documents.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed:: A copy of notarized affidavit on Stamp Paper declaring that his/her Concern is a 1.5.1 Proprietary Concern and he/she is sole proprietor of the Concern OR he/she is in position of "KARTA" of Hindu Undivided Family (HUF) and he/she has the authority, power and consent given by other partners to act on behalf of HUF.act on behalf of HUF.
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted:]:(a)A copy of the Partnership Deed, (b)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint 1.5.2 Venture Agreement on a stamp paper, (c)A copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (a)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (b) A copy of Memorandum and 1.5.3 Articles of Association of the Company. (c) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
IN CASE THE TENDER VALUE MORE THAN RS. 50 LAKHS; Tenderers shall submit a notarized affidavit on a non-judicial stamp paper stating that all their statements / documents submitted along with bid are true and factual.
Uploading of Declaration regarding Employment of Retired Engineer/Retired Railway Officer as per clause no.17 of Part-I of IRSGCC. [in the format attached in - Documents]
Uploading of NEFT FORM - as per the format attached with the tender document.
The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
Uploading of Statement Showing the particulars of Works on Hand & Works Completed as per the format attached to the tender document.
Uploading of certificate by local suppliers in regard to meeting the Minimum Local Content requirement to avail benefits under Public Procurement Policy Order-2017 (A) for procurement order of value less than Rs. 10 crores: self certificate in accordance with Para-9(a) of Public Procurement(Preference to Make in India) Order 2017. (B) For Procurement Order of value more than Rs. 10 crores, the certificate from Statutory auditor/cost auditor/practicing CA as the case may be in accordance with Para-9(b) of Public Procurement (Preference to Make in India) Order 2017.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
IN CASE OF SINGLE PACKET TENDERS; CONSORTIUM AGREEMENTS, JOINT VENTURE FIRMS AND MOUS SHALL NOT BE CONSIDERED
IN CASE OF TWO PACKET TENDERS CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED . BUT JOINT VENTURE FIRMS ARE CONSIDERED FOR ELIGIBILITY.
CONDITIONS FOR PARTICIPATION OF PROPRIETARY FIRM / PARTNERSHIP FIRM /PRIVATE LIMITED COMPANY / LIMITED COMPANY/ JV FIRMS:
In case the tenderer is an individual / proprietary concern, the experience and turnover shall be in the name and style of the Individual / Proprietary concern only.
In case the tenderer is a Partnership Firm, the experience and received contractual payments shall be in the name and style of the firm only. The other guidelines at Clause 18 of Part I of 4.1.1 IRSGCC shall be applicable . Note: The partner of a Partnership Firm cannot claim the credentials of Partnership firm to the extent of his share either during the subsistence of the Partnership firm or after its dissolution.
FOLLOWING DOCUMENTS SHALL BE ENCLOSED:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create 4.2.1 liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) and AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company 4.2.2 (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iii) copy of PAN number of the Company.
In case of JOINT VENTURE (JV) FIRMS: Clause No.17 of Part-I of IRSGCC with upto date correction slip shall be applicable in all aspects for Participation of Joint Venture[JV] firms in works tenders. JV firm should submit Memorandum of 4.2.3 Understanding[MOU] as per the format attached as annexure to the tender in DOCUMENTS. Submission of all other documents by JV firm / Members of JV should also be as per Cl.No.17.14 of Part-I of IRSGCC.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 4.2.4 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 4.2.5 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Uploading of other relevant documents connected to the tender; such as Declaration regarding employment of Retired Engineer/ Retired Railway officer, NEFT Form, List of Personnel/Organization, List of Plant/machinery, Particulars of works on hand and completed (As per the formats attached in the list of Documents)etc.
Hyderabad Division: 1) DLS/MLY- Augmentation/Up-gradation of infrastructural facilities for homing and maintenance of electric locomotives - Electrical Arrangements 2) Improvements to CH/LGD under Jurisdiction of SSE/W/S.O.- II/SLGD - Electrical Arrangements
38-WS-26-27-SrDEE-M-HYB~SCR
38-WS-26-27-SrDEE-M-HYB
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹3.1 L
9 Nov 2026
9 Nov 2026
20 Nov 2026
304 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,14,26,426 | ||
| — | 2000.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 25 mm dia 2 mm thick in concealed/surface as per the directions of Engineer at site | — | — | — | 62,000 | |
| — | 3000.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 32 mm dia 2 mm thick in concealed/surface as per the directions of Engineer at site | — | — | — | 1,65,000 | |
| — | 1600.00 | — | — | ||
| Supply & fixing of PVC conduit moulded bend pipe 32/25 mm dia 2 mm thick in concealed | — | — | — | 44,800 | |
| — | 1500.00 | — | — | ||
| Supply & fixing of PVC Junction box of suitable way for 32/25 mm dia 2 mm thick PVC conduit pipe in concealed | — | — | — | 37,500 | |
| — | 307.00 | — | — | ||
| Supply and laying of flexible 25mm PVC pipe | — | — | — | 5,526 | |
| — | 500.00 | — | — | ||
| Cutting and chipping the wall for laying the PVC conduit pipe and plastering after laying the PVC conduit pipe with cement and sand mortar mixed with 1:8 ratio, but without laying PVC conduit pipe. | — | — | — | 17,000 | |
| — | 200.00 | — | — | ||
| Supply, laying and fixing of water proof PVC casing & caping of size 20/25 mm of 2 metres length each including all connected accessories etc. | — | — | — | 13,000 | |
| — | 200.00 | — | — | ||
| Supply, laying and fixing of water proof PVC casing & caping of size 50mm of 2 mtrs length each including all connected accessories etc. | — | — | — | 24,000 | |
| — | 20.00 | — | — | ||
| Supply & erection of 18 way module size GI sheet metal/PVC box concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 3,880 | |
| — | 20.00 | — | — | ||
| Supply & erection of 18 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 4,840 | |
| — | 30.00 | — | — | ||
| Supply & erection of 12 way module size GI sheet metal/PVC box concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 4,740 | |
| — | 30.00 | — | — | ||
| Supply & erection of 12 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 5,670 | |
| — | 20.00 | — | — | ||
| Supply & erection of 8 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 2,440 | |
| — | 20.00 | — | — | ||
| Supply & erection of 8 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 3,060 | |
| — | 10.00 | — | — | ||
| Supply & erection of 6 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 960 | |
| — | 10.00 | — | — | ||
| Supply & erection of 6 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,220 | |
| — | 10.00 | — | — | ||
| Supply & erection of 4 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 760 | |
| — | 10.00 | — | — | ||
| Supply & erection of 4 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 910 | |
| — | 10.00 | — | — | ||
| Supply & erection of 3 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 610 | |
| — | 10.00 | — | — | ||
| Supply & erection of 3 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 770 | |
| — | 10.00 | — | — | ||
| Supply & erection of 2 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 400 | |
| — | 10.00 | — | — | ||
| Supply & erection of 2 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 460 | |
| — | 450.00 | — | — | ||
| Supply & erection of 6/10A 1-way switch | — | — | — | 29,250 | |
| — | 100.00 | — | — | ||
| Supply & erection of 6/10A socket with safety shutter | — | — | — | 8,500 | |
| — | 100.00 | — | — | ||
| Supply & fixing of 20/16A socket heavy duty with safety shutter | — | — | — | 14,100 | |
| — | 100.00 | — | — | ||
| Supply & erection of 20/16A one way switch | — | — | — | 8,800 | |
| — | 12000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 1.5 sq. mm Cu. Conductor | — | — | — | 2,04,000 | |
| — | 10000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 2.5 sq. mm FRLS Cu. Conductor | — | — | — | 2,80,000 | |
| — | 8000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 4 sq. mm FRLS Cu. Conductor | — | — | — | 3,52,000 | |
| — | 4000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 6 sq. mm FRLS Cu. Conductor | — | — | — | 3,76,000 | |
| — | 2000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core multi strand 10 sq. mm FRLS Cu. Conductor | — | — | — | 2,36,000 | |
| — | 600.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 1.5 mm sq.mm multi stranded FRLS cu. Conductor as per the directions of Engineer at site | — | — | — | 34,800 | |
| — | 350.00 | — | — | ||
| Supply, laying, connecting and commissioning of 3 core 2.5 mm sq.mm multi stranded flexible insulated FRLS cu. Conductor | — | — | — | 32,550 | |
| — | 400.00 | — | — | ||
| Supply and erection of ceiling rose. | — | — | — | 16,000 | |
| — | 10.00 | — | — | ||
| "Supply, fixing, testing and commissioning of (DP MCB - Incoming & SP/MCB - Outgoing) wall mounted of one row 12 module circuit breaker box made out of thermoplastic, (with metric knockouts for cable entry) with N terminal, size (202 x 238 x 111)mm complete. The LT distribution board shall be comprising with the following MCBs fixed in it conforming to IS:8828:1996, ISS & IE rules and site requirement.DP MCB 40-63 Amps. 'C' series = 01 No. (Incoming) SP MCB 6-32 Amps. 'B' series = 07 Nos. (Outgoing)" | — | — | — | 75,230 | |
| — | 10.00 | — | — | ||
| 1Suppy, fixing, connecting and commissioning of 6 way TPN DB in surface/concealed & comprising of 1 x 63A RCBO 100mA 10kA, 18 x 6/10/16/20/32A MCB SP B/C type 10kA with double door, flush mounting as per the directions of engineer at site. | — | — | — | 3,07,410 | |
| — | 6.00 | — | — | ||
| Suppy, fixing, connecting and commissioning of 8 way TPN DB in surface/concealed & comprising of 1 x 63A RCBO 100mA 10kA, 24 x 6/10/16/20/32A MCB SP B/C type 10kA with double door, flush mounting as per the directions of engineer at site. | — | — | — | 1,89,132 | |
| — | 2.00 | — | — | ||
| "Supply & fixing of 12 way Vertical TPN distribution board fixed on wall with the following switches, 1X160A 25KA 4pole microprocessor based with adjustable sensitivity MCCB I/C and 4 x 63 A 10KA 'C' Curve TPMCB out going, 4 x 32 A 10KA 'C' Curve TPMCB out going, 12x10/16/20A B/C Curve SPMCB 10kA out going with all other connected accessories etc.Note: MCCBs: ICs=100% ICu" | — | — | — | 1,17,486 | |
| — | 50.00 | — | — | ||
| Supply & fixing of 15W LED recess mounting down lighting round, greater than 180mm dia suitable to operate on 230v, 50Hz AC supply as per HQ specification and as per the directions of engineer at site. | — | — | — | 31,500 | |
| — | 12.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 35W LED Panel light fitting 2'x2' square type white with other connected accessories etc. as per the directions of engineer at site. | — | — | — | 32,760 | |
| — | 20.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 20 Watts 1200mm LED aluminum tube light fitting (warm white/cool white) with lamp including wiring connections etc. as per enclosed specification as per the directions of Engineer at site | — | — | — | 11,260 | |
| — | 10.00 | — | — | ||
| Supply and fixing of 10W LED tube light 6500K (cool day light) suitable to operate on 230V 50Hz AC supply should be similar to cat no.D531065 of Wipro make be as per HQ specification and as per the directions of engineer at site. | — | — | — | 3,250 | |
| — | 10.00 | — | — | ||
| Supply of Computer board of surface type modular box comprising of one number 16A modular socket with control switch and three numbers 6A modular socket with modular switches make duly providing connections, excluding running of supply conductor | — | — | — | 12,480 | |
| — | 10.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 90/100 watt LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 65 or better, having system complete as specification. | — | — | — | 55,000 | |
| — | 10.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 200 watt LED based flood light luminary with cool white light, pressure die cast aluminum housing, IP 65 or better, having system complete as per specification. | — | — | — | 95,000 | |
| — | 150.00 | — | — | ||
| Supply, erection, connecting, testing and commissioning of 100W LED Highbay light fixture complete with necessary mounting accessories, clamps and hardware etc. as per Railways specification | — | — | — | 7,20,300 | |
| — | 20.00 | — | — | ||
| Supply & fixing of 1200 mm sweep energy saving BLDC ceiling fan with copper winding and operated with remote, 300mm length of down rod(without shackle), input power not more than 28W, minimum 1.1mm aluminium blade material, double ball bearing, 2 canopy, to be operated in AC single phase supply. | — | — | — | 57,440 | |
| — | 20.00 | — | — | ||
| Supply and fixing of fan hooks (D Hook with double fasteners 10 mm for hanging ceiling fans) as per the direction of site Engineer | — | — | — | 5,780 | |
| — | 20.00 | — | — | ||
| Supply and fixing of 2/3/4/6 feet down rod as per the direction of site Engineer | — | — | — | 5,780 | |
| — | 6.00 | — | — | ||
| Supply & erection of 5m long hot dip galvanized octagonal pole with 130mm bottom A/F and 70mm top A/F, made up of 3mm thick HT Sheet & Bakelite sheet & suitable MCB including suitable size of loop-in & loop-out connectors (for mounting inside the base compartment of pole with hinged door opening arrangements), with base plate of size 200x200x12mm, M16X 600 long 'J' type EN8 grade foundation bolts, with 1000mm Single arm bracket for fixing of LED light with all connected accessories, etc. | — | — | — | 43,896 | |
| — | 6.00 | — | — | ||
| Excavation of pit for octagonal pole/ poles of suitable size in all type of soils as per the direction of engineer at site | — | — | — | 6,000 | |
| — | 5.00 | — | — | ||
| Provision of concrete foundation and constructing the plinth as per the directions of engineer at site. | — | — | — | 20,015 | |
| — | 10.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 60W LED street light complete with necessary clamps and hardware etc. as per Railway specification | — | — | — | 28,100 | |
| — | 1.00 | — | — | ||
| Supply, fabrication, fixing of MS channels and angles of suitable sizes as per site condition including necessary clamps, bolts, nuts, washers including painting with two coat of red oxide, one coat of aluminum etc. and welding as per directions of engineer at site. | — | — | — | 66,852 | |
| — | 600.00 | — | — | ||
| Supply of 4core 16 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 1,09,200 | |
| — | 600.00 | — | — | ||
| Laying, connecting, testing and commissioning of LT PVC/XLPE cable of size 4 core 16 Sq.mm | — | — | — | 5,400 | |
| — | 1200.00 | — | — | ||
| Supply of 4core 25 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 2,70,000 | |
| — | 1200.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4 core 25 sq.mm multi strand LT XLPE cable as per directions of the engineer at site. | — | — | — | 13,200 | |
| — | 1500.00 | — | — | ||
| Supply of 4core 70 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 8,40,000 | |
| — | 1500.00 | — | — | ||
| Laying of 4 core 70 sq.mm multi strand LT XLPE cable, connecting with suitable glands connectors etc. Testing and commissioning of LT XLPE cable as per directions of the engineer at site. | — | — | — | 49,500 | |
| — | 1000.00 | — | — | ||
| Supply of 4core 120 mm² LT XLPE aluminium UG Cable, 1100 Volts as per IS:7098/Pt.I/1988 or latest. | — | — | — | 7,84,000 | |
| — | 1000.00 | — | — | ||
| Laying of 4 core 120 sq.mm multi strand LT XLPE cable, connecting with suitable glands connectors etc. Testing and commissioning of LT XLPE cable as per directions of the engineer at site. | — | — | — | 50,000 | |
| — | 4300.00 | — | — | ||
| Supply and fixing of G.I. wire earth continuity of 8 SWG G.I. wire | — | — | — | 38,700 | |
| — | 2400.00 | — | — | ||
| Supply & erection of HDPE pipe of 110mm dia, PN-6, PE-100 of material grade as per IS 4984 or latest and the directions of Engineer at site | — | — | — | 10,44,000 | |
| — | 1700.00 | — | — | ||
| Supply & erection of HDPE pipe of 50mm dia, PN-6, PE-100 of material grade as per IS 4984 or latest and the directions of Engineer at site | — | — | — | 3,06,000 | |
| — | 3600.00 | — | — | ||
| Excavation of cable trench 30 cm widex90cm deep in all types of soils for LTUG cable as per instruction of engineer at site | — | — | — | 4,68,000 | |
| — | 500.00 | — | — | ||
| Cutting of asphalted road/ concrete/ cement/ under the track etc., and excavation of cable trench 30 cm widex90cm deep road etc., for laying of LTUG cable. After laying of cable the trench should be brought to its original position by providing tar/ concrete/ cement as per the site conditions and as per directions of Rly. Engineer. | — | — | — | 1,08,000 | |
| — | 100.00 | — | — | ||
| Supply & fixing of cable termination lug & glands as per the site requirement | — | — | — | 10,000 | |
| — | 8.00 | — | — | ||
| Design, fabrication, fixing, connecting and commissioning of outdoor type cable termination box of 2'x2'x1' size with 2mm thick sheet duly providing of clamps to fix with pole and have proper locking arrangements as per the site requirement. This item also includes termination of existing cable to the termination box with copper bus bar of size 75x5mm & 63A 4P MCB as per the directions of the engineer at site. | — | — | — | 47,840 | |
| — | 10.00 | — | — | ||
| Supply, fixing, connecting and commissioning of Master control 63A TPN MCB as per the direction of the Engineer at site | — | — | — | 20,040 | |
| — | 12.00 | — | — | ||
| Supply & fixing of 32A capacity MCB DP similar to GM make as per the directions of engineer at site | — | — | — | 5,280 | |
| — | 10.00 | — | — | ||
| Supply and fixing of 40 amp 4pole 32mA RCCB as per the direction of the engineer at site. | — | — | — | 27,900 | |
| — | 12.00 | — | — | ||
| Supply & erection of modular 32A MCB SP as per the directions of engineer at site | — | — | — | 2,700 | |
| — | 12.00 | — | — | ||
| Supply & erection of modular 25A MCB SP as per the directions of engineer at site | — | — | — | 2,256 | |
| — | 100.00 | — | — | ||
| Supply, erection, testing and commissioning of fabricated Shrouded type DSL(Down Shop Lead) consisting of 3 Phase & earth conductor supported to the existing structure with suitable brackets and insulators. The current collector shall be mounted with suitable MS bracket in the crane on DSL side together with incoming and outgoing supply to the system in complete with all connected accessories. | — | — | — | 4,32,900 | |
| — | 50.00 | — | — | ||
| Design, supply and erection of 16W LED light fitting with IP 65 protection necessary hardware material suitable to work on 24V DC. 3 dimensional type for pit lighting ("A" type for pitlights (10+4+2W) as per the directions of engineer at site. | — | — | — | 1,77,500 | |
| — | 50.00 | — | — | ||
| Design, supply and erection of 16W LED light fitting with IP 65 protection necessary hardware material suitable to work on 24V DC. 3 dimensional type for pit lighting ("B" type for pitlights (4+8+4W) as per the directions of engineer at site. | — | — | — | 1,77,500 | |
| — | 100.00 | — | — | ||
| Supply and fixing of Metal flush Box of 4 module to be provided for Pit Lighting arrangements, including making cavity/opening duly cutting concrete, steel rods, of RCC with other connected masonry works etc. for fixing the metal flush boxes. Make: similar to M/s. Legrand/L&T/Havells/Anchor. | — | — | — | 12,400 | |
| — | 15.00 | — | — | ||
| Design, supply of control panel units containing 3 nos. SMPS POWER SUPPLY UNITS enclosed in sheet steel enclosure with all connected safety accessories, Indications & Controls dedicated for the High Power LED Based 16 W Pit Lights. As per following spec, 1 Panel containing 3 nos. of SMPS units will be suitable for 21 nos. of 16W pitlights/catwalk lights). Specification for each SMPS unit: MODEL # OSSI/SMPSU/30A/13, MAKE: OSSE, Input voltage: 180 to 260 Volts, Output Voltage: 24 volts +/- 1% Regulation - CV Output Current: 10 amps Protections Short Circuit Proof, Over Voltage Protection Ripple: <200mv | — | — | — | 3,14,250 | |
| — | 7.00 | — | — | ||
| Provision of DB with industrial plug socket 4 pin 3 pole plug of 20 A capacity and 20A TPMCB (3 phase + Earth 440 volts) as per IEC 61439-3 or latest | — | — | — | 20,713 | |
| — | 7.00 | — | — | ||
| Provision of DB with industrial plug socket 5 pin 3 pole with 63 A capacity (3 phase + Neutral + Earth) and 63A TPMCB as per IEC 61439-3 or latest | — | — | — | 69,629 | |
| — | 1.00 | — | — | ||
| "Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Indoor type) with 200 amps sectionalized electrolytic copper bus bar (copper bus bar should be RYBN uniform sizes). LT switchgear confirming to IS-8623 or latest. Advanced Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 100 A 4pole 35/36KA microprocessor based with adjustable sensitivity MCCB (I/C), 1x100A change over switch, Out goings: 6x40 Amps TPN MCB, 2x32A DP 'C' curve 10KA MCB, 6x16A SP MCB.Note: MCCBs: ICs=100% ICu, all MCCBs should be microprocessor based." | — | — | — | 1,21,045 | |
| — | 1.00 | — | — | ||
| "Design, fabrication, supply, fixing, connecting, testing and commissioning of steel sheet iron cubical type 14 SWG Outdoor Main distribution board with the following switches/ MCCBs including sectionalized copper bus bar of capacity 800 Amps (copper bus bar should be RYBN uniform sizes). LT switchgear confirming to IS-8623 or latest. Along with 1 No Multifunction meters (bidirectional) and 0.2S class CTs with RS485 port and RYB LED indication lamps with control MCBs and all other connected accessories etc., 2 x 400 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault along with 400A On load change over, 4 x 200/250 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault, 2 x125/160 A 4 pole 36KA MCCB Microprocessor based including suitable spreader link, OL(Over Load), SC(Short circuit), Ground fault, 6x63A 10KA FP MCB, 10 x 32A 10kA FP MCB, 4x32A 10KA DP MCB Note: 1) All MCCBs should be Microprocessor only 2) ICs=100% Icu and all cables terminations to be done along with double compression glands and required lugs as per the direction of Engineer at site." | — | — | — | 5,41,517 | |
| — | 1.00 | — | — | ||
| "Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Outdoor type) with 400 amps sectionalized electrolytic copper bus bar (copper bus bar should be RYBN uniform sizes). LT panel board should confirm to IS-8623 or latest. Advanced Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 200/250 A 4pole 35/36KA microprocessor based with adjustable sensitivity MCCB (I/C),Out goings: 4x100 Amps 4 pole, 35/36 KA microprocessor based with adjustable sensitivity MCCB, 8x63A TPN 'C' curve 10KA MCB, 4x32A DP 'C' curve 10KA MCB. (2) Incoming for Generator supply 2x 125A 35/36KA microprocessor based with adjustable sensitivity MCCB. Note: 1) All MCCBs should be Microprocessor only 2) ICs=100% Icu and all cables terminations to be done along with double compression glands and required lugs as per the direction of Engineer at site." | — | — | — | 4,71,699 | |
| — | 200.00 | — | — | ||
| Fabrication, supply, laying and fixing of S.S perforated cable tray of size 200 mm x 50 mm x 2 mm thickness with cover, SS 304 grade. The cable trays should be fixed on the roof, under shed structure, wall, with suitable clamps, bolts & nuts etc., firmly and rigidly as per the directions of engineer at site | — | — | — | 5,79,400 | |
| — | 4.00 | — | — | ||
| Supply, installation and commissioning of Split Air conditioner of with 5 BEE Star rating inverter, copper coil, ISEER:5.0 or above with connected accessories, suitable heavy duty outdoor stand, etc. | — | — | — | 1,98,000 | |
| — | 80.00 | — | — | ||
| "Supply and fixing of extra copper pipe for Split AC (if required as per site condition) " | — | — | — | 34,000 | |
| — | 80.00 | — | — | ||
| Supply and fixing of Drain pipe CPVC of 25mm dia including accessories, bend, elbows, tees, flanges, tappings, wall sleeves, hangers supports anchors, etc. | — | — | — | 15,440 | |
| — | 80.00 | — | — | ||
| Supply and fixing of 4 corex4Sq.mm flexible FRLS copper cable (communication cabling) for Split/Cassette AC | — | — | — | 29,200 | |
| — | 20.00 | — | — | ||
| — | 300.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NEFTForm.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_12_compressed11.pdf
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
GCCACS11dt.13.03.2026.pdf
ATTACHMENT
ApprovedTB38-26-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .